890 resultados para real option analysis


Relevância:

30.00% 30.00%

Publicador:

Resumo:

We present nine newly observed transits of TrES-3, taken as part of a transit timing program using the RISE instrument on the Liverpool Telescope. A Markov-Chain Monte Carlo analysis was used to determine the planet star radius ratio and inclination of the system, which were found to be R-p/R-star = 0.1664(-0.0018)(+0.0011) and i = 81.73(-0.04)(+0.13), respectively, consistent with previous results. The central transit times and uncertainties were also calculated, using a residual-permutation algorithm as an independent check on the errors. A re-analysis of eight previously published TrES-3 light curves was conducted to determine the transit times and uncertainties using consistent techniques. Whilst the transit times were not found to be in agreement with a linear ephemeris, giving chi(2) = 35.07 for 15 degrees of freedom, we interpret this to be the result of systematics in the light curves rather than a real transit timing variation. This is because the light curves that show the largest deviation from a constant period either have relatively little out-of-transit coverage or have clear systematics. A new ephemeris was calculated using the transit times and was found to be T-c(0) = 2454632.62610 +/- 0.00006 HJD and P = 1.3061864 +/- 0.0000005 days. The transit times were then used to place upper mass limits as a function of the period ratio of a potential perturbing planet, showing that our data are sufficiently sensitive to have probed sub-Earth mass planets in both interior and exterior 2:1 resonances, assuming that the additional planet is in an initially circular orbit.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Microscopic simulation models are often evaluated based on visual inspection of the results. This paper presents formal econometric techniques to compare microscopic simulation (MS) models with real-life data. A related result is a methodology to compare different MS models with each other. For this purpose, possible parameters of interest, such as mean returns, or autocorrelation patterns, are classified and characterized. For each class of characteristics, the appropriate techniques are presented. We illustrate the methodology by comparing the MS model developed by He and Li [J. Econ. Dynam. Control, 2007, 31, 3396-3426, Quant. Finance, 2008, 8, 59-79] with actual data.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this investigation Raman spectroscopy was shown to be a method that could be used to monitor the polymerisation of PMMA bone cement. Presently there is no objective method that orthopaedic surgeons can use to quantify the curing process of cement during surgery. Raman spectroscopy is a non-invasive, non-destructive technique that could offer such an option. Two commercially available bone cements (Palacos® R and SmartSet® HV) and different storage conditions (4 and 22°C) were used to validate the technique. Raman spectroscopy was found to be repeatable across all conditions with the completion of the polymerisation process particularly easy to establish. All tests were benchmarked against current temperature monitoring methods outlined in ISO and ASTM standards. There was found to be close agreement with the standard methods and the Raman spectroscopy used in this study.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Regarding the Real: Cinema, Documentary, and the Visual Arts develops an interdisciplinary approach to documentary film, focusing on its cultural and formal relations to other visual arts, such as animation, assemblage, photography, painting, sculpture, and architecture. The book considers the work of figures whose preferred film language is associative and fragmentary, and for whom the documentary is an endlessly open form, an unstable expressive phenomenon that cannot but interrogate the validity of its own narratives and representational modes. Combining close analysis with cultural history, Regarding the Real calls for a re-assessment of the influence of the modern arts in subverting the structures of realism typically associated with documentary filmmaking.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Raman spectroscopy with far-red excitation has been used to study seized, tableted samples of MDMA (N-methyl-3,4-methylenedioxyamphetamine) and related compounds (MDA, MDEA, MBDB, 2C-B and amphetamine sulfate), as well as pure standards of these drugs. We have found that by using far-red (785 nm) excitation the level of fluorescence background even in untreated seized samples is sufficiently low that there is little difficulty in obtaining good quality data with moderate 2 min data accumulation times. The spectra can be used to distinguish between even chemically-similar substances, such as the geometrical isomers MDEA and MBDB, and between different polymorphic/hydrated forms of the same drug. Moreover, these differences can be found even in directly recorded spectra of seized samples which have been bulked with other materials, giving a rapid and non-destructive method for drug identification. The spectra can be processed to give unambiguous identification of both drug and excipients (even when more than one compound has been used as the bulking agent) and the relative intensities of drug and excipient bands can be used for quantitative or at least semi-quantitative analysis. Finally, the simple nature of the measurements lends itself to automatic sample handling so that sample throughputs of 20 samples per hour can be achieved with no real difficulty.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The use of new mobile technologies is still in its infancy in many secondary schools and there is limited evidence of the educational and pedagogical benefits on pupils’ learning in the formal school context. This qualitative study focuses on the use of handheld devices to teach a topic in geography to an examination class. Action research combined with pupil observations and focus group interviews are used to capture the pupils’ experiences of using mediascapes. Activity Theory is used as a lens to structure the analysis of the data and to report on the cognitive and affective impact of m-learning on pupils’ academic performance in the topic. Increased attainment and the development of wider skills for lifelong learning were identified in the study. The adaptability of the majority of pupils to the technology resulted in increased levels of willingness to learn in this novel context.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A method of measuring the temperature of the fast electrons produced in ultraintense laser-plasma interactions is described by inducing photonuclear reactions, in particular (gamma,n) and (gamma,3n) reactions in tantalum. Analysis of the gamma rays emitted by the daughter nuclei of these reactions using a germanium counter enables a relatively straightforward near real-time temperature measurement to be made. This is especially important for high temperature plasmas where alternative diagnostic techniques are usually difficult and time consuming. This technique can be used while other experiments are being conducted. (C) 2002 American Institute of Physics.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Thermal fatigue analysis based on 2D finite difference and 3D finite element methods is carried out to study the performance of solar panel structure during micro-satellite life time. Solar panel primary structure consists of honeycomb structure and composite laminates. The 2D finite difference (I-DEAS) model yields predictions of the temperature profile during one orbit. Then, 3D finite element analysis (ANSYS) is applied to predict thermal fatigue damage of solar panel structure. Meshing the whole structure with 2D multi-layer shell elements with sandwich option is not efficient, as it misses thermal response of the honeycomb structure. So we applied a mixed approach between 3D solid and 2D shell elements to model the solar panel structure without the sandwich option.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Increasing use of teledermatology should be based on demonstration of favourable accuracy and cost-benefit analysis for the different methods of use of this technique. Objectives To evaluate the clinical efficacy and cost-effectiveness of real-time and store-and-forward teledermatology.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

To date, the usefulness of stereoscopic visual displays in research on manual interceptive actions has never been examined. In this study, we compared the catching movements of 8 right-handed participants (6 men, 2 women) in a real environment (with suspended balls swinging past the participant, requiring lateral hand movements for interception) with those in a situation in which similar virtual ball trajectories were displayed stereoscopically in a virtual reality system (Cave Automated Virtual Environment [CAVE]; Cruz-Neira, Sandin, DeFranti, Kenyon, & Hart, 1992) with the head fixated. Catching the virtual ball involved grasping a lightweight ball attached to the palm of the hand. The results showed that, compared to real catching, hand movements in the CAVE were (a) initiated later, (b) less accurate, (c) smoother, and (d) aimed more directly at the interception point. Although the latter 3 observations might be attributable to the delayed movement initiation observed in the CAVE, this delayed initiation might have resulted from the use of visual displays. This suggests that stereoscopic visual displays such as present in many virtual reality systems should be used circumspectly in the experimental study of catching and should be used only to address research questions requiring no detailed analysis of the information-based online control of the catching movements.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper describes how worst-case error analysis can be applied to solve some of the practical issues in the development and implementation of a low power, high performance radix-4 FFT chip for digital video applications. The chip has been fabricated using a 0.6 µm CMOS technology and can perform a 64 point complex forward or inverse FFT on real-time video at up to 18 Megasamples per second. It comprises 0.5 million transistors in a die area of 7.8×8 mm and dissipates 1 W, leading to a cost-effective silicon solution for high quality video processing applications. The analysis focuses on the effect that different radix-4 architectural configurations and finite wordlengths has on the FFT output dynamic range. These issues are addressed using both mathematical error models and through extensive simulation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dynamic switching spectroscopy piezoresponse force microscopy is developed to separate thermodynamic and kinetic effects in local bias-induced phase transitions. The approaches for visualization and analysis of five-dimensional data are discussed. The spatial and voltage variability of relaxation behavior of the a-c domain lead zirconate-titanate surface suggest the interpretation in terms of surface charge dynamics. This approach is applicable to local studies of dynamic behavior in any system with reversible bias-induced phase transitions ranging from ferroelectrics and multiferroics to ionic systems such as batteries, fuel cells, and electroresistive materials. (C) 2011 American Institute of Physics. [doi:10.1063/1.3590919]

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Analysis of binding recognition and conformation of biomolecules is of paramount important in understanding of their vital functions in complex biological systems. By enabling sub-wavelength light localization and strong local field enhancement, plasmonic biosensors have become dominant tools used for such analysis owing to their label-free and real-time attributes1,2. However, the plasmonic biosensors are not well-suited to provide information regarding conformation or chemical fingerprint of biomolecules. Here, we show that plasmonic metamaterials, consisting of periodic arrays of artificial split-ring resonators (SRRs)3, can enable capabilities of both sensing and fingerprinting of biomolecules. We demonstrate that by engineering geometry of individual SRRs, localized surface plasmon resonance (LSPR) frequency of the metamaterials could be tuned to visible-near infrared regimes (Vis-NIR) such that they possess high local field enhancement for surface-enhanced Raman scattering spectroscopy (SERS). This will provide the basis for the development of a dual mode label-free conformational-resolving and quantitative detection platform. We present here the ability of each sensing mode to independently detect binding adsorption and to identify different conformational states of Guanine (G)-rich DNA monolayers in different environment milieu. Also shown is the use of the nanosensor for fingerprinting and detection of Arginine-Glycine-Glycine (RGG) peptide binding to the G-quadruplex aptamer. The dual-mode nanosensor will significantly contribute to unraveling the complexes of the conformational dynamics of biomolecules as well as to improving specificity of biodetection assays that the conventional, population-averaged plasmonic biosensors cannot achieve.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Recently, two fast selective encryption methods for context-adaptive variable length coding and context-adaptive binary arithmetic coding in H.264/AVC were proposed by Shahid et al. In this paper, it was demonstrated that these two methods are not as efficient as only encrypting the sign bits of nonzero coefficients. Experimental results showed that without encrypting the sign bits of nonzero coefficients, these two methods can not provide a perceptual scrambling effect. If a much stronger scrambling effect is required, intra prediction modes, and the sign bits of motion vectors can be encrypted together with the sign bits of nonzero coefficients. For practical applications, the required encryption scheme should be customized according to a user's specified requirement on the perceptual scrambling effect and the computational cost. Thus, a tunable encryption scheme combining these three methods is proposed for H.264/AVC. To simplify its implementation and reduce the computational cost, a simple control mechanism is proposed to adjust the control factors. Experimental results show that this scheme can provide different scrambling levels by adjusting three control factors with no or very little impact on the compression performance. The proposed scheme can run in real-time and its computational cost is minimal. The security of the proposed scheme is also discussed. It is secure against the replacement attack when all three control factors are set to one.