628 resultados para prostheses
Resumo:
Ultra wideband (UWB) radar has been extensively investigated both theoretically and practically for the identification buried artifacts. Ground probe radar (GPR) concentrates on the identification of lightly buried land mines, unexploded ordnance (UXO) and archeological targets. The same technology is proposed in a similar context for the rapid identification of in vivo implanted metallic prostheses. The technique is based on resonance based target identification and the paper investigates UWB scattering from a metallic hip prosthesis in free space as a first step in the identification process.
Resumo:
Hydrogels may be described as cross~linked hydrophilic polymers that swell but do not dissolve in water. They have been utilised in many biomedical applications, as there is the potential to manipulate the properties for a given application by changing the chemical structure of the constituent monomers. This project is focused on the development of novel hydrogels for keratoprosthesis (KPro). The most commonly used KPro model consists of a tansparent central stem witb a porous peripheral skirt. Clear poly (methyl methacrylate) (PMMA) core material used in the Strampelli KPros prosthesis has not been the cause of failure found in other core and skirt prostheses. However, epithelialization of this kind of solid, rigid optic material is clearly impossible. The approach to the development of a hydrogeJ for potential KPro use adopted in this work is to develop soft core material to mimic the properties of the natural cornea by incorporating some hydrophilic monomers such as N, N-dimethyacrylamide (NNSMA) N~vinyl pyrrolidone (NVP) and acryloylmorpholine (AMO) with methyl methactylate (MMA). Most of these materials have been used in other ophthalmic applications, such as contact lens. However, an unavoidable limitation of simple .MMA copolymers as conventional hydrogels is poor mechanical strength. The hydrogel for use in this application must be able to withstand the stresses involved during the surgical procedure involved with KPro surgery and the in situ stresses such as the deforming force of the eyelid during the blink cycle. Thus, semi-interpenetrating polymer networks (SIPNs) based on ester polyurethane, AMO, NVP and NNDMA were examined in this work and were found to have much improved mechanical properties at water contents between 40% and 70%. Polyethylene glycol monomethacrylate (PEG MA) was successfully incorporated in order to modulate protein deposition and cell adhesion. Porous peripheral skirts were fabricated using different types of porosigen. The water content mechanical properties, surface properties and cell response of these various materials have been investigated in this thesis. These studies demonstrated that simple hydrogel SIPNs which show isotropic mechanical behaviour, are not ideal KPro materials since they do not mimic the anisotropic behaviour of natural cornea. The final stage of the work has concentrated on the study of hydrogels reinforced with mesh materials. They offer a promising approach to making a hydrogel that is very flexible but strong under tension, thereby having mechanical properties closer to the natural cornea than has been previously possible.
Resumo:
A clinical isolate of Proteus mirabilis containing R-plasmid RP1 (R+ cells), grown in both iron- and carbon- limited chemically defined media in mixed culture with plasmid-free (R- cells), did not disappear as expected, due to adherence of R+ cells to the wall of the chemostat vessel. Plasmid RP1 promoted adherence to glass and to medical prostheses. The hydrophobicity and surface charge of R+ cells were different from those of R- cells and both factors may contribute to the adherence of R+ cells to surfaces. The mode of cultivation of the cells, whether batch or continuous culture, were also found to affect the result. Antibodies raised against homologous cells increased the surface hydrophobicity of both R+ and R- cells and eliminated the differences between them. Results for surface hydrophobicity varied with the method used for measuring it. R+ cells were more sensitive than R- cells to tbe bacteridical action of normal serum and whole blood and to phagocytosis as measured by chemiluminescence. No clear differences were revealed in the protein antigens of R+ and R- cells by both SDS PAGE gels and immunoblots reacted with homologous antibodies. However, lectins revealed differences in the sugars exposed on the cell surfaces. Chemical analysis of R&43 and R- cells also revealed differences in the content of 2-keto-3-deoxy-D-manno-2-octulosonate, lipopolysaccharide and total fatty acids, when cells were grown in media containing added iron; however, no qualitative differences in the lipopolysaccharide were found. Removal of iron from the medium was found to have considerable effects on the chemical structure of R+ cells but not of R- ones. Adhesion to prostheses and to leucocytes is discussed in the light of the results and the clinical relevance outlined with respect to the initiation of infection and the association of virulence with antibiotic resistance.
Resumo:
Propionibacterium acnes is a Gram-positive bacterium that forms part of the normal flora of the skin, oral cavity, large intestine, the conjunctiva and the external ear canal. Although primarily recognized for its role in acne, P. acnes is an opportunistic pathogen, causing a range of postoperative and device-related infections. These include infections of the bones and joints, mouth, eye and brain. Device-related infections include those of joint prostheses, shunts and prosthetic heart valves. P. acnes may play a role in other conditions, including inflammation of the prostate leading to cancer, SAPHO (synovitis, acne, pustulosis, hyperostosis, osteitis) syndrome, sarcoidosis and sciatica. If an active role in these conditions is established there are major implications for diagnosis, treatment and protection. Genome sequencing of the organism has provided an insight into the pathogenic potential and virulence of P. acnes. © 2011 Expert Reviews Ltd.
Resumo:
Biotribology is essentially the study of friction, lubrication and wear in biological systems. The area has been widely studied in relation to the behaviour of synovial joints and the design and behaviour of hip joint prostheses, but only in the last decade have serious studies been extended to the eye. In the ocular environment - as distinct from articular joints - wear is not a major factor. Both lubrication and friction are extremely important, however; this is particularly the case in the presence of the contact lens, which is a medical device important not only in vision correction but also as a therapeutic bandage for the compromised cornea. This chapter describes the difficulty in replicating experimental conditions that accurately reflect the complex nature of the ocular environment together with the factors such as load and rate of travel of the eyelid, which is the principal moving surface in the eye. Results obtained across a range of laboratories are compared.
Resumo:
Introduction: The rehabilitation of edentulous patients is one of the main challenges of Dentistry. Objective: To assess the satisfaction and the impact of oral health on quality of life of patients rehabilitated with conventional complete dentures in both arcades. Method: A clinical trial with 25 patients rehabilitated with CCD was conducted. The impact of oral health in individuals quality of life was evaluated through the Brazilian version of the OHIP-Edent and the patient satisfaction was evaluated using a specific questionnaire. The instruments were applied before and 3 months after rehabilitation. Results: There was a statistically significant improvement (p <0.001) on the impact of the quality of life of the denture users after the new rehabilitation. The analysis of 4 OHIP domains also showed statistically significant improvement (p <0.001). The final overall satisfaction with the dentures was statistically superior to initial satisfaction (p <0.001). The analysis of the specific aspects of satisfaction with CCD after 3 months of rehabilitation also showed significant results in the improvement of every aspect. Conclusion: Patients disappointed with their dentures, have their quality of life improved after the new rehabilitation, reducing the negative impact of the prostheses on oral health, and improving their satisfaction with the rehabilitation.
Resumo:
This study presents a simple, fast and low cost technique for fabrication new conventional dentures from the duplication of old prosthesis in use by the patient. Colorless acrylic resin was poured into the moulds obtained by duplication of prosthesis. With the replicas obtained a functional impressions using polyether should be performed and they are stabilized with occlusal registration in acrylic resin. The molds need to be castings and mounted on an semi-adjustable articulator. The artificial teeth are positioned with the assistance of a guide made condensation silicone to reproduce the positioning of the teeth of the old prosthesis and fixed with wax 7. After approval of the teeth on the trial in wax, without adjustment of the planes, the prosthesis may be processed in the laboratory. After occlusal adjustment in the articulator the same can be installed.
Resumo:
An appropriate design of a prosthetic rehabilitation should not impute the restoration of occlusal vertical dimension (OVD) to new prostheses, at the risk of the patient does not adapt to a new condition, since a certain amount of time is often necessary for adaptation to a new OVD. This article performed prosthetic rehabilitation with an overlay provisional removable partial denture prior to definitive treatment because the patient showed a considerable decrease in the OVD. Three techniques for OVD determination were used. It is possible to conclude that the use of interim removable partial dentures is of great importance at the beginning of the rehabilitation treatment in order to adapt the patient to a new occlusal condition.
Resumo:
An appropriate design of a prosthetic rehabilitation should not impute the restoration of occlusal vertical dimension (OVD) to new prostheses, at the risk of the patient does not adapt to a new condition, since a certain amount of time is often necessary for adaptation to a new OVD. This article performed prosthetic rehabilitation with an overlay provisional removable partial denture prior to definitive treatment because the patient showed a considerable decrease in the OVD. Three techniques for OVD determination were used. It is possible to conclude that the use of interim removable partial dentures is of great importance at the beginning of the rehabilitation treatment in order to adapt the patient to a new occlusal condition.
Resumo:
STATEMENT OF PROBLEM: A number of methods have been described for the fabrication of complete dentures. There are 2 common ways to make conventional complete dentures: a traditional method and a simplified method. PURPOSE: The purpose of this study was to conduct a systematic review to compare the efficiency of simplified and traditional methods for the fabrication of complete dentures. MATERIAL AND METHODS: The review was conducted by 3 independent reviewers and included articles published up to December 2013. Three electronic databases were searched: MEDLINE-PubMed, The Cochrane Library, and ISI Web of Science. A manual search also was performed to identify clinical trials of simplified versus traditional fabrication of complete dentures. RESULTS: Six articles were classified as randomized controlled clinical trials and were included in this review. The majority of the selected articles analyzed general satisfaction, denture stability, chewing ability and function, comfort, hygiene, esthetics, speech function, quality of life, cost, and fabrication time. CONCLUSIONS: Although the studies reviewed demonstrate some advantages of simplified over traditional prostheses, such as lower cost and clinical time, good chewing efficiency, and a positive effect on the quality of life, the reports related the use of different simplified methods for the fabrication of complete dentures. Additional randomized controlled trials that used similar simplified techniques for the fabrication of complete dentures should be performed with larger sample sizes and longer follow-up periods.
Resumo:
Total knee arthroplasty (TKA) has revolutionized the life of millions of patients and it is the most efficient treatment in cases of osteoarthritis. The increase in life expectancy has lowered the average age of the patient, which requires a more enduring and performing prosthesis. To improve the design of implants and satisfying the patient's needs, a deep understanding of the knee Biomechanics is needed. To overcome the uncertainties of numerical models, recently instrumented knee prostheses are spreading. The aim of the thesis was to design and manifacture a new prototype of instrumented implant, able to measure kinetics and kinematics (in terms of medial and lateral forces and patellofemoral forces) of different interchangeable designs of prosthesis during experiments tests within a research laboratory, on robotic knee simulator. Unlike previous prototypes it was not aimed for industrial applications, but purely focusing on research. After a careful study of the literature, and a preliminary analytic study, the device was created modifying the structure of a commercial prosthesis and transforming it in a load cell. For monitoring the kinematics of the femoral component a three-layers, piezoelettric position sensor was manifactured using a Velostat foil. This sensor has responded well to pilot test. Once completed, such device can be used to validate existing numerical models of the knee and of TKA and create new ones, more accurate.It can lead to refinement of surgical techniques, to enhancement of prosthetic designs and, once validated, and if properly modified, it can be used also intraoperatively.
Resumo:
The past few decades have brought many changes to the dental practice and the technology has become ready available. The result of a satisfactory rehabilitation treatment basically depends on the balance between biological and mechanical factors. The marginal adaptation of crowns and prosthetic structures is vital factor for long-term success. The development of CAD / CAM technology in the manufacture of dental prostheses revolutionized dentistry, this technology is capable of generating a virtual model from the direct digital scanning from the mouth, casts or impressions. It allows the planning and design of the structure in a computered software. The virtual projects are obtained with high precision and a significant reduction in clinical and laboratory time. Thus, the present study (Chapters 1, 2 and 3) computed microtomography was used to evaluate, different materials, different CAD/CAM systems, different ways of obtaining virtual model (with direct or indirect scanning), and in addition, also aims to evaluate the influence of cementing agent in the final adaptation of crowns and copings obtained by CAD / CAM. Furthermore, this study (Chapter 4, 5 and 6) also aims to evaluate significant differences in vertical and horizontal misfits in abutment-free frameworks on external hexagon implants (HE) using full castable UCLAs, castable UCLAs with cobalt-chromium pre-machined bases and obtained by CAD / CAM with CoCr or Zirconia by different scanning and milling systems. For this, the scanning electron microscopy and interferometry were used. It was concluded that the CAD / CAM technology is capable to produce restorations, copings and screw-retained implant-supported frameworks in different materials and systems offering satisfactory results of marginal accuracy, with significative reduction in clinical and laboratory time.
Resumo:
Purpose: Computed Tomography (CT) is one of the standard diagnostic imaging modalities for the evaluation of a patient’s medical condition. In comparison to other imaging modalities such as Magnetic Resonance Imaging (MRI), CT is a fast acquisition imaging device with higher spatial resolution and higher contrast-to-noise ratio (CNR) for bony structures. CT images are presented through a gray scale of independent values in Hounsfield units (HU). High HU-valued materials represent higher density. High density materials, such as metal, tend to erroneously increase the HU values around it due to reconstruction software limitations. This problem of increased HU values due to metal presence is referred to as metal artefacts. Hip prostheses, dental fillings, aneurysm clips, and spinal clips are a few examples of metal objects that are of clinical relevance. These implants create artefacts such as beam hardening and photon starvation that distort CT images and degrade image quality. This is of great significance because the distortions may cause improper evaluation of images and inaccurate dose calculation in the treatment planning system. Different algorithms are being developed to reduce these artefacts for better image quality for both diagnostic and therapeutic purposes. However, very limited information is available about the effect of artefact correction on dose calculation accuracy. This research study evaluates the dosimetric effect of metal artefact reduction algorithms on severe artefacts on CT images. This study uses Gemstone Spectral Imaging (GSI)-based MAR algorithm, projection-based Metal Artefact Reduction (MAR) algorithm, and the Dual-Energy method.
Materials and Methods: The Gemstone Spectral Imaging (GSI)-based and SMART Metal Artefact Reduction (MAR) algorithms are metal artefact reduction protocols embedded in two different CT scanner models by General Electric (GE), and the Dual-Energy Imaging Method was developed at Duke University. All three approaches were applied in this research for dosimetric evaluation on CT images with severe metal artefacts. The first part of the research used a water phantom with four iodine syringes. Two sets of plans, multi-arc plans and single-arc plans, using the Volumetric Modulated Arc therapy (VMAT) technique were designed to avoid or minimize influences from high-density objects. The second part of the research used projection-based MAR Algorithm and the Dual-Energy Method. Calculated Doses (Mean, Minimum, and Maximum Doses) to the planning treatment volume (PTV) were compared and homogeneity index (HI) calculated.
Results: (1) Without the GSI-based MAR application, a percent error between mean dose and the absolute dose ranging from 3.4-5.7% per fraction was observed. In contrast, the error was decreased to a range of 0.09-2.3% per fraction with the GSI-based MAR algorithm. There was a percent difference ranging from 1.7-4.2% per fraction between with and without using the GSI-based MAR algorithm. (2) A range of 0.1-3.2% difference was observed for the maximum dose values, 1.5-10.4% for minimum dose difference, and 1.4-1.7% difference on the mean doses. Homogeneity indexes (HI) ranging from 0.068-0.065 for dual-energy method and 0.063-0.141 with projection-based MAR algorithm were also calculated.
Conclusion: (1) Percent error without using the GSI-based MAR algorithm may deviate as high as 5.7%. This error invalidates the goal of Radiation Therapy to provide a more precise treatment. Thus, GSI-based MAR algorithm was desirable due to its better dose calculation accuracy. (2) Based on direct numerical observation, there was no apparent deviation between the mean doses of different techniques but deviation was evident on the maximum and minimum doses. The HI for the dual-energy method almost achieved the desirable null values. In conclusion, the Dual-Energy method gave better dose calculation accuracy to the planning treatment volume (PTV) for images with metal artefacts than with or without GE MAR Algorithm.
Resumo:
Las TIC son inseparables de la museografía in situ e imprescindibles en la museografía en red fija y móvil. En demasiados casos se han instalado prótesis tecnológicas para barnizar de modernidad el espacio cultural, olvidando que la tecnología debe estar al servicio de los contenidos de manera que resulte invisible y perfectamente imbricada con la museografía tradicional. Las interfaces móviles pueden fusionar museo in situ y en red y acompañar a las personas más allá del espacio físico. Esa fusión debe partir de una base de datos narrativa y abierta a obras materiales e inmateriales de otros museos de manera que no se trasladen las limitaciones del museo físico al virtual. En el museo in situ tienen sentido las instalaciones hipermedia inmersivas que faciliten experiencias culturales innovadoras. La interactividad (relaciones virtuales) debe convivir con la interacción (relaciones físicas y personales) y estar al servicio de todas las personas, partiendo de que todas, todos tenemos limitaciones. Trabajar interdisciplinarmente ayuda a comprender mejor el museo para ponerlo al servicio de las personas.