911 resultados para productivity losses
Resumo:
The biology and productivity of Myschocytarus drewseni were studied in semi urban conditions at Rio Claro, S P - Brazil. We observed 51 nest foundations, of which 24 (47%) were destroyed or predated, 13 (25.5 %) were abandoned and 14 (27.5%) completed the cycle. The life-span of colonies ranged from 44-427 days with a mean of 216.7 ± 140.6 days, producing 8-390 cells with a mean of 125.7 ± 137.9 cells, and 2-303 adults with a mean of 89.4 ± 110.36 adults. We observed a maximum of 3 utilizations/cell. This showed that the species presents asynchronous foundation and abandoningoccurs throughout the year. Also, the chance of a colony utilizing the same cells two or three times for adult production is highly dependent on the colony size/age, and the relation between them is positive, meaning that there is a greater chance of cell re-utilization in larger/older colonies.
Resumo:
Includes bibliography
Resumo:
This paper presents the comparison of three topologies of multilevel inverters applied to drive an induction motor of 500 kVA/4.16 kV. The multilevel inverters analyzed are: a neutral point clamped inverter, a symmetrical cascaded multilevel inverter and a hybrid asymmetrical cascaded multilevel inverter. The performance indexes used in the comparison are total harmonic distortion, first order distortion factor, semiconductors power losses distribution and heat-sink volume. The comparison is developed with the purpose of finding the efficiency and the heat-sink volume where the three systems present the same output filter. ©2008 IEEE.
Resumo:
Given that the total amount of losses in a distribution system is known, with a reliable methodology for the technical loss calculation, the non-technical losses can be obtained by subtraction. A usual method of calculation technical losses in the electric utilities uses two important factors: load factor and the loss factor. The load factor is usually obtained with energy and demand measurements, whereas, to compute the loss factor it is necessary the learning of demand and energy loss, which are not, in general, prone of direct measurements. In this work, a statistical analysis of this relationship using the curves of a sampling of consumers in a specific company is presented. These curves will be summarized in different bands of coefficient k. Then, it will be possible determine where each group of consumer has its major concentration of points. ©2008 IEEE.
Resumo:
Incluye Bibliografía
Resumo:
The aim of this study was to analyze temporal ..d vertical variation of the biomass and of phytoplankton primary productivity in an urban eutrophic reservoir, in relation to the physical and chemical characteristics of the water. The physical and chemical variables of the water were defined in the limnetic region of the reservoir, at depths of 0.0; 0.5; 1.0; 2.0; 3.0 and 4.0 meters. Three samples were taken to define both the physical and chemical variables, concomitantly with the biomass (chlorophyll-a and phaeophytin) and phytoplankton primary productivity (C-14 method). Based on data obtained on differences in depth of the mixture zone and the euphotic zone, it is hypothesised that, depending on the time of the year, phytoplankton is conditioned by differences in the light and nutrient regimes, which change according to the constant loads of nutrients thrown into the system. The highest concentration of chlorophyll-a in the photic zone of the limnetic region was observed in November 2000 (1,197.3 mg Chl L -1) and the lowest in November 1999 (94.0 mg ChI L -1), whereas the profiles of primary activity of phytoplankton presented the highest rates on the surface of the water column, with values varying from 84.7 (May 2000) to 1,376.7mg C m -3 h -1 (December 2000). Annual primary productivity was calculated at 1,567.0gC m -2y -1, considered euproductive. The primary productivity profiles reported in this study are typical of aquatic eutrophic systems, rich in plankton and with low light penetration. It can be stated that Garças Lake is a system that suffers from anthropogenic impact, through receiving large loads of organic pollution, reflecting on the physical and chemical characteristics of the water and on the high values of biomass and primary phytoplankton activity. © National Institute of Ecology, New Delhi.
Resumo:
Although the management of the coffee crop is well established in Brazil, there is still room for its improvement in relation natural resources available in each region, aiming the increase in productivity. Here are presented results regarding the fate of the fertilizer nitrogen (N) applied to a coffee plantation related to the prevailing soil water conditions. Soil water balances are discussed, which allowed evaluation of the root distribution, determinations of the crop coefficient and of the soil water conditions during the development of the crop. Approximately, 60% of the root system was distributed in the 0-0.3 m soil layer and the average crop coefficient was 1.1 for 3 to 5 year old plants. Using an N label, the 15N, it was possible to study the distribution of N in the plant and in the soil and establishes general N balances, which also include losses like leaching and volatilization. After two years of ammonium sulfate application, at rates of 280 (1st year) and 350 (2nd year) kg.ha-1 of N, in four equal application performed during the period of positive growth rate, the recuperation of fertilizer N were 19.1% by the aerial plant part and 9.4% by the roots, 12.6% remained in the soil and 11.2% in the litter; 0.9% was lost by volatilization and 2.3% by leaching; 26.3% was exported through harvesting and 18.2% remained in non evaluated compartments. From the applied 630 kg.ha -1 of N during the two years, 180 kg.ha -1 of N were found in the plant (shoot and root), which corresponds to 28.6%; 150 kg.ha -1 of N remained available for the next years(soil and litter), and only 20 kg.ha -1 of N were effectively lost (volatilization and leaching).
Resumo:
Includes bibliography
Resumo:
Includes bibliography
Resumo:
Fraud detection in energy systems by illegal consumers is the most actively pursued study in non-technical losses by electric power companies. Commonly used supervised pattern recognition techniques, such as Artificial Neural Networks and Support Vector Machines have been applied for automatic commercial frauds identification, however they suffer from slow convergence and high computational burden. We introduced here the Optimum-Path Forest classifier for a fast non-technical losses recognition, which has been demonstrated to be superior than neural networks and similar to Support Vector Machines, but much faster. Comparisons among these classifiers are also presented. © 2009 IEEE.
Resumo:
Includes bibliography
Resumo:
Includes bibliography
Resumo:
The cultivation of fruit plants from temperate climate in tropical or subtropical regions can be a good income alternative for the producer. However, due to the little existent information about cultivation of those fruit plants, the producers use imported techniques of other producing areas, or even an association of practices used for other fruit plants, pointing out the leaf spray fertilization of micronutrients without appropriate scientific base. In this context, the objective of this study was to verify the effect of the leaf spray fertilization of B and Zn on productivity and fruit quality of Japanese pear tree. The experiment was conducted from 2004 to 2005, in Ilha Solteira, in northwestern São Paulo State-Brazil. The climate is, according to the Köpppen Classification, tropical wet and dry (Aw). The 'Okusankichi' cultivar, grafted on Pyrus communis L. rootstock was used as well as doses of 110 g.ha-1 of B and 250 g.ha-1 of Zn in each application. The treatments were: T1. water, T2. boric acid, T3. zinc sulfate, T4. T2 + T3, T5. boric acid + urea + citric acid + EDTA, T6. zinc sulfate + urea + citric acid + EDTA, T7. T5 + T6, T8. boric acid + urea + citric acid + EDTA + sodium molibdate + sulfur + calcium chloride, T9. zinc sulfate + urea + citric acid + EDTA + Fe sulfate + Mn sulfate + Mg sulfate and, T10. T8+T9. A randomized blocks design was used and the averages were compared by Tukey test. In the first crop the mixture of boric acid with quelating agents were efficient to supply B to the plants and zinc sulfate plus quelating agents were efficient to increase Zn leaf content. However, the productivity and the fruit quality were not influenced by the leaf spray of B and Zn. In the second crop the leaf content of B and Zn and the productivity were not influenced by the leaf spray; the boric acid and the zinc sulfate with or without quelating agents increased the contents of total soluble solids and, the boric acid with or without quelating agents increased the contents of total titratable acidity.
Resumo:
Includes Bibliography
Resumo:
Includes bibliography