954 resultados para perfusion-weighted MRI


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To assess the value of cerebral perfusion CT (PCT) in children with traumatic brain injury in prediciting their consecutive clinical outcome. Materials and methods: Twelve paediatric patients with acute traumatic brain injury underwent cerebral CT coupled with PCT during their admission at the emergency room (ER). PCT maps were reviewed for mean transit time (MTT), regional cerebral blood flow (rCBF) and regional cerebral blood volume (rCBV) abnormalities. PCT results were compared to short- and mid-term clinical outcome. Results: 3 patients with low Glasgow Coma Scale (GCS) (98) and bad clinical outcome showed an increased MTT and decreased rCBV and rCBF. 5 patients with low GCS and good clinical outcome showed an increased MTT without abnormalities of rCBV and rCBF. In patients with GCS 08 and good outcome, PCT maps were normal in 2 cases; transient PCT abnormalities were identified in one case with an embedded fracture of the skull and in one case with an epileptic seizure. Conclusion: Cerebral PCT can identify diffuse abnormalities of cerebral perfusion in children with traumatic brain injury showing a low initial GCS and a bad outcome. PCT can be a valuable tool to predict the severity of the prognosis of these patients as soon as they are evaluated by CT-scan during their admission at the ER.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Résumé de l'article : L'hyperplasie intimale est un processus de remodelage vasculaire ubiquitaire après une lésion, pouvant menacer la perméabilité de tout type de reconstruction vasculaire. Les mécanismes physiopathologiques impliqués dans le développement de l'hyperplasie intimale ne sont que partiellement élucidés. Il est par conséquent nécessaire d'effectuer des recherches complémentaires afin d'en améliorer la compréhension et ainsi permettre l'élaboration de nouvelles stratégies thérapeutiques médicamenteuses. La culture de veines en milieu statique permet le développement de l'hyperplasie intimale. Ce modèle maintient la viabilité tissulaire, comme décrit précédemment dans d'autres études, mais empêche l'analyse des paramètres hémodynamiques. La mise au point d'un modèle de perfusion in vitro permettant la perfusion de segments vasculaires représente une approche expérimentale intégrant les différents facteurs hémodynamiques. Le système de perfusion (Ex Vivo Vein Support System) que nous avons élaboré conserve l'intégrité pariétale ainsi que les propriétés vasomotrices des veines pour une durée de 14 jours. Cette étude démontre que les deux modèles permettent le développement de l'hyperplasie intimale. Toutefois, les propriétés vasomotrices ainsi que l'influence des paramètres hémodynamiques ne peuvent être analysées que par l'utilisation du système de perfusion. Ce dernier a permis de perfuser des vaisseaux humains sans contamination bactérienne tout en maintenant l'intégrité cellulaire. Ce modèle de perfusion se rapproche plus des conditions hémodynamiques rencontrées in vivo que le modèle statique. Abstract : Background. Intimal hyperplasia (IH) is a vascular remodeling process which often leads to failure of arterial bypass or hemodialysis access. Experimental and clinical work have provided insight in IH development; however, further studies under precise con-trolled conditions are required to improve therapeutic strategies to inhibit IH development. Ex vivo perfusion of human vessel segments under standardized hemodynamic conditions may provide an adequate experimental approach for this purpose. Therefore, chronically perfused venous segments were studied and compared to traditional static culture procedures with regard to functional and histomorphologic characteristics as well as gene expression. Materials and methods. Static vein culture allowing high tissue viability was performed as previously described. Ex vivo vein support system (EVVSS) was performed using a vein support system consisting of an incubator with a perfusion chamber and a pump. EVVSS allows vessel perfusion under continuous flow while maintaining controlled hemodynamic conditions. Each human saphenous vein was divided in two parts, one cultured in a Pyrex dish and the other part perfused in EVVSS for 14 days. Testing of vasomotion, histomorphometry, expression of CD 31, Factor VIII, MIB 1, α-actin, and PAI-1 were determined before and after 14 days of either experimental conditions. Results, Human venous segments cultured under traditional or perfused conditions exhibited similar IH after 14 days as shown by histomorphometry. Smooth-muscle cell ( SMC) was preserved after chronic perfusion. Although integrity of both endothelial and smooth-muscle cells appears to be maintained in both culture conditions as confirmed by CD31, factor VIII and α-actin expression, a few smooth-muscle cells in the media stained positive for factor VIII. Cell-proliferation marker MIB-1 was also detected in the two settings and PAI-1 mRNA expression and activity increased significantly after 14 days of culture and perfusion. Conclusion. This study demonstrates the feasibility to chronically perfuse human vessels under sterile conditions with preservation of cellular integrity and vascular contractility. To gain insights into the mechanisms leading to IH, it will now be possible to study vascular remodeling not only under static conditions but also in hemodynamic environment mimicking as closely as possible the flow conditions encountered in reconstructive vascular surgery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The objective of our study was to establish optimal perfusion conditions for high-resolution postmortem angiography that would permit dynamic visualization of the arterial and venous systems. MATERIALS AND METHODS: Cadavers of two dogs and one cat were perfused with diesel oil through a peristaltic pump. The lipophilic contrast agent Lipiodol Ultra Fluide was then injected, and angiography was performed. The efficiency of perfusion was evaluated in the chick chorioallantoic membrane. RESULTS: Vessels could be seen up to the level of the smaller supplying and draining vessels. Hence, both the arterial and the venous sides of the vascular system could be distinguished. The chorioallantoic membrane assay revealed that diesel oil enters microvessels up to 50 microm in diameter and that it does not penetrate the capillary network. CONCLUSION: After establishing a postmortem circulation by diesel oil perfusion, angiography can be performed by injection of Lipiodol Ultra Fluide. The resolution of the images obtained up to 3 days after death is comparable to that achieved in clinical angiography.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To compare MDCT, MRI and 18F-FDG PET/CT for the detection of peritoneal carcinomatosis due to ovarian cancerMethods and Materials: Fifteen women (mean age 65±) with clinical suspicion of ovarian cancer and peritoneal carcinomatosis underwent MDCT, MRI and 18F-FDG PET/CT, simultaneously and shortly performed before surgery (delay 8.1± days). According to the peritoneal cancer index nine abdominopelvic regions were defined. We applied four scores of lesion size on MDCT and MR images, while the maximal standard uptake value (SUVmax) was measured on 18F-FDG PET/CT. Three sites of lymphadenopathy and posterobasal pleural carcinomatosis were also analyzed. First, one radiologist blindly and separately read MDCT and MR images, while one nuclear physician blindly read PET/CT images grading each lesion according to four diagnostic certitudes. Secondly, all the images were reviewed jointly and compared with histopathology. Receiver operating characteristics (ROC) analysis was performed.Results: Peritoneal implants were proven in ten women (75%). Altogether, 228 abdominopelvic sites were compared. Sensitivity and specificity for MDCT was 90.2% and 90.6%, for MRI 93.5% and 86.3%, and for 18F-FDG PET/CT 92.7% and 95.7%, respectively. ROC area under the curve were 0.93 for MDCT and MRI, and 0.96 for 18F-FDG PET/CT respectively. No significant differences (p=0.11) were found between the three modalities.Conclusion: Although MRI revealed to be the most sensitive and 18F-FDG PET/CT the most specific modality, no significant differences were shown between the three techniques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: Patients with symptoms of semicircular canal dehiscence often undergo both CT and MR imaging. We assessed whether FIESTA can replace temporal bone CT in evaluating patients for SC dehiscence. MATERIALS AND METHODS: We retrospectively reviewed 112 consecutive patients (224 ears) with vestibulocochlear symptoms who underwent concurrent MR imaging and CT of the temporal bones between 2007 and 2009. MR imaging protocol included a FIESTA sequence covering the temporal bone (axial 0.8-mm section thickness, 0.4-mm spacing, coronal/oblique reformations; 41 patients at 1.5T, 71 patients at 3T). CT was performed on a 64-row multidetector row scanner (0.625-mm axial acquisition, with coronal/oblique reformations). Both ears of each patient were evaluated for dehiscence of the superior and posterior semicircular canals in consensual fashion by 2 neuroradiologists. Analysis of the FIESTA sequence and reformations was performed first for the MR imaging evaluation. CT evaluation was performed at least 2 weeks after the MR imaging review, resulting in a blinded comparison of CT with MR imaging. CT was used as the reference standard to evaluate the MR imaging results. RESULTS: For SSC dehiscence, MR imaging sensitivity was 100%, specificity was 96.5%, positive predictive value was 61.1%, and negative predictive value was 100% in comparison with CT. For PSC dehiscence, MR imaging sensitivity was 100%, specificity was 99.1%, positive predictive value was 33.3%, and negative predictive value was 100% in comparison with CT. CONCLUSIONS: MR imaging, with a sensitivity and negative predictive value of 100%, conclusively excludes SSC or PSC dehiscence. Negative findings on MR imaging preclude the need for CT to detect SC dehiscence. Only patients with positive findings on MR imaging should undergo CT evaluation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To examine the reproducibility of carotid artery dimension measurements using 3T MRI. MATERIALS AND METHODS: Ten healthy volunteers underwent three scans on two occasions for assessment of total vessel wall area (TVWA), total luminal area (TLA), and minimum (MinT) and maximum (MaxT) vessel wall thickness. A double inversion-recovery (IR) fast gradient-echo (FGRE) sequence was used on a commercial 3T system. During the first visit the subjects were scanned twice. The third scan was performed at least four days later. One observer traced all scans, and a second observer retraced the first scan series. RESULTS: For TVWA an interclass correlation (ICC) of 0.994 was calculated with all three scans taken into account. The interobserver ICC was 0.984. The agreement between the scans for TLA showed an ICC of 0.982 with an interobserver ICC of 0.998. For MinT and MaxT an ICC of 0.843 and 0.935 were calculated, with interobserver ICCs of 0.860 and 0.726, respectively. CONCLUSION: With the use of a commercial 3T MR system, TVWA, TLA, and wall thickness measurements of the carotid artery can be assessed with good reproducibility.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Congenital nephrogenic diabetes insipidus (CNDI) is a rare disease characterized by the inability of the kidney to respond to arginine vasopressin (AVP). The absence of the neurohypophyseal 'bright signal' on T1 sequence magnetic resonance imaging (MRI) is considered as an argument in favour of the diagnosis of central diabetes insipidus (CDI). This observation is challenged as we hereby present a case of a child diagnosed with CNDI and who did not present MRI pituitary bright signal. A 6-month-old male presented with failure to thrive, polyuria and polydypsia. Family history revealed that the mother, 35 years of age, had been presenting polydypsia and polyuria, and she was investigated at the age of 6 years with no concluding diagnosis. The patient's physical exam showed a weight of 5215 g (−3 DS) and clinical signs of dehydration. The patient's plasma sodium level was 155 mmol/L, osmolality 305 mOsm/kg and urine osmolality 150 mOsm/kg. Brain MRI showed in T1 sequences the absence of the posterior pituitary bright signal suggesting the diagnosis of CDI (Figure 1). The child was treated with synthetic AVP analogue 1-desamino-8-d-arginine vasopressin (DDAVP) without improvement, which led to the consideration of CNDI. The diagnosis was confirmed by an elevated serum level of AVP of 214 pmol/L (reference value ≤4.34 pmol/L) and by genetic analysis demonstrating and T106C mutation in the V2R (X-linked CNDI). The child was treated with thiazide diuretic and increased fluids with restricted sodium intake. This resulted in catch-up growth and improved neurological development. A follow-up MRI was performed 6 months after the start of therapy with the same technique. At that time, the child's weight had improved to 9310 g (−1.5 DS) corresponding to a gain of 22 g per day, and he did not present any clinical signs of dehydration and had a normal plasma level of sodium (140 mmol/L). MRI showed that the bright signal was still absent.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Several molecular therapies require the implantation of cells that secrete biotherapeutic molecules and imaging the location and microenvironment of the cellular implant to ascertain its function. We demonstrate noninvasive in vivo magnetic resonance imaging (MRI) of self-assembled microcontainers that are capable of cell encapsulation. Negative contrast was obtained to discern the microcontainer with MRI; positive contrast was obtained in the complete absence of background signal. MRI on a clinical scanner highlights the translational nature of this research. The microcontainers were loaded with cells that were dispersed in an extracellular matrix, and implanted both subcutaneously and in human tumor xenografts in SCID mice. MRI was performed on the implants, and microcontainers retrieved postimplantation showed cell viability both within and proximal to the implant. The microcontainers are characterized by their small size, three dimensionality, controlled porosity, ease of parallel fabrication, chemical and mechanical stability, and noninvasive traceability in vivo.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The complex structural organization of the white matter of the brain can be depicted in vivo in great detail with advanced diffusion magnetic resonance (MR) imaging schemes. Diffusion MR imaging techniques are increasingly varied, from the simplest and most commonly used technique-the mapping of apparent diffusion coefficient values-to the more complex, such as diffusion tensor imaging, q-ball imaging, diffusion spectrum imaging, and tractography. The type of structural information obtained differs according to the technique used. To fully understand how diffusion MR imaging works, it is helpful to be familiar with the physical principles of water diffusion in the brain and the conceptual basis of each imaging technique. Knowledge of the technique-specific requirements with regard to hardware and acquisition time, as well as the advantages, limitations, and potential interpretation pitfalls of each technique, is especially useful.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We propose a deep study on tissue modelization andclassification Techniques on T1-weighted MR images. Threeapproaches have been taken into account to perform thisvalidation study. Two of them are based on FiniteGaussian Mixture (FGM) model. The first one consists onlyin pure gaussian distributions (FGM-EM). The second oneuses a different model for partial volume (PV) (FGM-GA).The third one is based on a Hidden Markov Random Field(HMRF) model. All methods have been tested on a DigitalBrain Phantom image considered as the ground truth. Noiseand intensity non-uniformities have been added tosimulate real image conditions. Also the effect of ananisotropic filter is considered. Results demonstratethat methods relying in both intensity and spatialinformation are in general more robust to noise andinhomogeneities. However, in some cases there is nosignificant differences between all presented methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Image registration has been proposed as an automatic method for recovering cardiac displacement fields from Tagged Magnetic Resonance Imaging (tMRI) sequences. Initially performed as a set of pairwise registrations, these techniques have evolved to the use of 3D+t deformation models, requiring metrics of joint image alignment (JA). However, only linear combinations of cost functions defined with respect to the first frame have been used. In this paper, we have applied k-Nearest Neighbors Graphs (kNNG) estimators of the -entropy (H ) to measure the joint similarity between frames, and to combine the information provided by different cardiac views in an unified metric. Experiments performed on six subjects showed a significantly higher accuracy (p < 0.05) with respect to a standard pairwise alignment (PA) approach in terms of mean positional error and variance with respect to manually placed landmarks. The developed method was used to study strains in patients with myocardial infarction, showing a consistency between strain, infarction location, and coronary occlusion. This paper also presentsan interesting clinical application of graph-based metric estimators, showing their value for solving practical problems found in medical imaging.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ophthalmologists typically acquire different image modalities to diagnose eye pathologies. They comprise, e.g., Fundus photography, optical coherence tomography, computed tomography, and magnetic resonance imaging (MRI). Yet, these images are often complementary and do express the same pathologies in a different way. Some pathologies are only visible in a particular modality. Thus, it is beneficial for the ophthalmologist to have these modalities fused into a single patient-specific model. The goal of this paper is a fusion of Fundus photography with segmented MRI volumes. This adds information to MRI that was not visible before like vessels and the macula. This paper contributions include automatic detection of the optic disc, the fovea, the optic axis, and an automatic segmentation of the vitreous humor of the eye.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: To assess inter-observer variability of renal blood oxygenation level-dependent MRI (BOLD-MRI) using a new method of analysis, called the concentric objects (CO) technique, in comparison with the classical ROI (region of interest)-based technique. METHODS: MR imaging (3T) was performed before and after furosemide in 10 chronic kidney disease (CKD) patients (mean eGFR 43±24ml/min/1.73m(2)) and 10 healthy volunteers (eGFR 101±28ml/min1.73m(2)), and R2* maps were determined on four coronal slices. In the CO-technique, R2* values were based on a semi-automatic procedure that divided each kidney in six equal layers, whereas in the ROI-technique, all circles (ROIs) were placed manually in the cortex and medulla. The mean R2*values as assessed by two independent investigators were compared. RESULTS: With the CO-technique, inter-observer variability was 0.7%-1.9% across all layers in non-CKD, versus 1.6%-3.8% in CKD. With the ROI-technique, median variability for cortical and medullary R2* values was 3.6 and 6.8% in non-CKD, versus 4.7 and 12.5% in CKD; similar results were observed after furosemide. CONCLUSION: The CO-technique offers a new, investigator-independent, highly reproducible alternative to the ROI-based technique to estimate renal tissue oxygenation in CKD.