986 resultados para mini tomato
Resumo:
Ready to eat pasta meals are an important segment of convenience food, but these products are subjected to significant changes in physico-chemical properties during storage, which reduce their acceptability at the time of consumption. A deep understanding of the properties of the single phases, their dependence upon formulation, and the changes they undergo during storage is very important to intelligently intervene on products properties to improve their quality at the time of consumer’s consumption. This work has focused on the effect of formulation on physico-chemical properties of pasta and tomato sauce with a special focus on mechanical/rheological attributes and water status. Variable considered in pasta formulation were gluten, glycerol and moisture content and their effect was studied in both freshly cooked or shelf-stable cooked pasta. The effect of multiple hydrocolloids (at different levels) was considered in the case of tomato sauce. In the case of pasta, it was found that water content was indeed a very important variable in defying pasta mechanical properties and water status. Higher moisture contents in pasta resulted in softer samples and reduced the changes in physico-chemical parameters during storage. Glycerol was found to favor water uptake and to soften the pasta matrix, acting as plasticizer and increasing molecular mobility. The addition of gluten hardened pasta but did not affect the water status. The combination of higher amount of gluten (15%, g gluten / 100 g product) with higher moisture content (59-65%, g water / 100 g product) were found to minimize the physico-chemical changes occurring in RTE pasta meals during storage, improving quality at longer storage times. Hydrocolloids added into tomato sauce modulated its mechanical attributes and water status in very different manner, depending on hydrocolloid type and concentration. This may allow to produce tomato sauce for different applications and that are expected to have different performance if placed in contact with pasta in a RTE meal. Future work should include an investigation of how the interaction between the two phases (pasta and sauce) can be modulated and controlled by controlling the properties of the single phases with the goal of obtaining highly acceptable products also at longer storage times.
Resumo:
O aparelho Pêndulo é eficaz na correção das más oclusões de Classe II, com comprometimento dentoalveolar superior. No entanto, a perda de ancoragem caracterizada pela mesialização dos pré-molares superiores, e pela vestibularização e protrusão dos incisivos superiores, constitui um grave efeito colateral deste dispositivo. O objetivo deste estudo foi avaliar as possíveis alterações dentárias e esquelética, sagitais e verticais, decorrentes do uso do Pêndulo modificado, ancorado em mini-implantes. Dez indivíduos foram tratados neste estudo, sendo que telerradiografias em norma lateral foram realizadas no início do tratamento, e imediatamente após a remoção do Pêndulo. Em cada indivíduo foram instalados dois mini-implantes no palato, que receberam carga imediata por meio da ativação do Pêndulo modificado, apoiado nestes dispositivos de ancoragem temporária. Nenhum dos dentes avaliados apresentou alterações verticais estatisticamente significantes; o mesmo ocorreu para as alterações esqueléticas verticais e sagitais, e para o trespasse vertical e horizontal. Com relação às alterações estatisticamente significantes, o primeiro molar superior moveu-se para distal aproximadamente 5,6mm em 6,2 meses, e com inclinação distal média de 7,100. Os segundos pré-molares superiores distalizaram em média 2,7mm e inclinaram 5,550; já os segundos molares superiores moveram-se em média 4,6mm para distal com uma inclinação de 13,700; valores estes também considerados estatisticamente significantes. O sistema de distalização de molares superiores, composto pelo Pêndulo modificado ancorado em mini-implantes, mostrou-se eficaz na correção da má oclusão de Classe II, sem produzir os efeitos de perda de ancoragem. (AU)
Resumo:
A distalização dos molares superiores é uma opção de tratamento da má oclusão de Classe II, quando o envolvimento é principalmente dentoalveolar. Dispositivos intrabucais como o aparelho Pêndulo, dispensam a colaboração do paciente quanto ao uso, porém promovem efeitos muitas vezes indesejáveis como a vestibularização dos dentes anteriores que participam na ancoragem e a inclinação dos molares distalizados. Após o surgimento dos Dispositivos de Ancoragem Temporária (DATs), como o mini-implante pode-se alcançar a ancoragem de forma previsível e eficiente. Com isto, por meio de um estudo prospectivo, foram avaliadas as alterações dentárias, promovidas pela distalização de molares superiores com um aparelho Pêndulo modificado, apoiado em dois mini-implantes instalados no palato de 10 indivíduos, sendo 2 do sexo feminino e 8 do masculino, com média de idade de 14,3 anos. A amostra foi composta por 20 modelos digitalizados em 3D, obtidos de em duas fases: no início do tratamento (T1) e após distalização com sobrecorreção de 1 mm (T2), permitindo quantificar as alterações dentárias sagitais, transversais e possíveis movimentos de rotação, angulação e movimentos verticais. Os resultados obtidos mostraram que no sentido sagital, houve uma efetiva distalização com significância estatística, para os segundos molares superiores; primeiros molares superiores em média de 4,34 mm e 3,91mm para o lado direito e esquerdo, respectivamente, e para os segundos pré-molares do lado direito e esquerdo de 2,06 mm e 1,95 mm, respectivamente. Porém, para os dentes anteriores, foi constatada a perda de ancoragem. No sentido transversal, o maior aumento ocorreu na região dos dentes posteriores. Os movimentos de rotação, angulação e vertical dos primeiros molares superiores, indicam que houve rotação mesiovestibular e inclinação distal das coroas destes dentes de ambos os lados; as medidas verticais, demonstram que houve movimento significativo apenas para o primeiro molar direito, com inclinação distal pela intrusão da cúspide distal. Este dispositivo mostrou-se eficaz na correção da Classe II em um tempo médio de 6,2 meses.(AU)
Resumo:
In emerging markets, the amount of mobile communication and the number of occasions mobile phones are used are increasing. More and more settings appropriate or not for mobile phone usage are being exposed. Although prohibited by many governments, there is evidence that use of new mobile devices while driving are somehow becoming current everyday practice, hence legitimatizing usage for many users. Dominant dangerous behavior in the absence of enforced legal framework is being deployed and has become routine for many m-users. This chapter adopts a qualitative case study approach (20 cases) to examine the public transport drivers' motives, logic and legitimacy processes. The question which these issues raise in the light of advancing m-technologies is: How do, in the context of emerging market, undesired emerging routines enactment get to be reflected upon and voluntarily disregarded to maximize the benefits of m-technologies while minimizing their drawbacks? Findings point out at multiple motives for usage including external social pressure through the ubiquitous 24/7 usage of mtechnology, lack of alternative communication protocol, real time need for action and from an internal perspectives boredoms, lack of danger awareness, blurring of the boundaries between personal and business life and lack of job fulfillment are uncovered as key factors. As secondary dynamic factors such as education, drivers work' histories, impunity, lack of strong consumer opposition appear central in shaping the development of the routines. © 2011, IGI Global.
Resumo:
Keratoconus is a bilateral degenerative disease characterized by a non-inflammatory, progressive central corneal ectasia (typically asymmetric) and decreased vision. In its early stages it may be managed with spectacles and soft contact lenses but more commonly it is managed with rigid contact lenses. In advanced stages, when contact lenses can no longer be fit, have become intolerable, or corneal damage is severe, a penetrating keratoplasty is commonly performed. Alternative surgical techniques, such as the use of intra-stromal corneal ring segments (INTACS) have been developed to try and improve the fit of rigid contact lenses in keratoconic patients and avoid penetrating keratoplasties. This case report follows through the fitting of rigid contact lenses in an advanced keratoconic cornea after an INTACS procedure and discusses clinical findings, treatment options, and the use of mini-scleral and scleral lens designs as they relate to the challenges encountered in managing such a patient. Mini-scleral and scleral lenses are relatively easy to fit, and can be of benefit to many patients, including advanced keratoconic patients, post-INTAC patients and post-penetrating keratoplasty patients. © 2011 British Contact Lens Association.
Resumo:
Given the multiplicity of languages and media present in contemporary texts, the work with digital genres characterizes itself as essential for teaching, reading and writing. Virtual media is already present in many dayly activities that require the use of language. This shows that the globalized world brings new demands of literacy and various reading practices. Given this perspective, we propose to work the multiliteracies present in the new texts from the enunciative discourse Bakhtinian assumptions. For this, we chose to be as the object of research / intervention, the horror flash fiction multimodal discursive genre, because it is a multissemiótico digital statement of virtual circulation. In this context, this study aimed to understand how the teaching of this kind can contribute to the development of knowledge related to reading and text production, required by multiliteracies, by performing a Didactic Sequence in the classroom, specifically for two classes of elementary school, 7th and 8th grades of public school. The research was based on Bakhtin's theory and the Circle (2009, 2011) on gender perspective in a dialogic and the proposed Dolz and Schneuwly (2004) for the text of teaching through sequences Teaching. We also use the precepts of multiliteracies focused on Rojo (2012, 2013). The methodology used was based on a qualitative approach. We consider the analysis of minicontos produced by students, it's own hibridism of multiliteracies, the discursive characteristics such as composition, style and subject content, in addition to relations dialogicity present in these statements. At the end of the study, we realized that our intervention contributed to the expansion of knowledge of the subjects involved related to reading and multimodal genre production.
Resumo:
El empleo de implantes dentales se ha convertido en práctica habitual en la odontología humana actual, siendo su empleo cada vez más frecuente. Esto es debido tanto a los buenos resultados, como a la reducción de costes de esta técnica, lo que permite un mayor acceso al público general. El cerdo ha sido utilizado como modelo experimental en muchos trabajos de investigación, tanto en medicina humana como veterinaria. Hay multitud de artículos publicados que hacen referencia a su utilización en campos como la anestesia, traumatología, cardiología, odontología, etc. Actualmente en odontología los implantes osteointegrados tiene gran importancia y en la mayoría de los estudios se hace referencia casi en su totalidad al comportamiento de estos, en sus diferentes modalidades, en pacientes adultos con hueso maduro. Sólo algunas publicaciones recientes describen el empleo de estas técnicas en niños con casos graves de edentulismo. Por esta razón se planteó llevar a cabo este estudio en animales jóvenes sobre hueso inmaduro y de esta manera podría obtenerse información acerca de los problemas que podrían plantearse durante todo el proceso, desde su colocación hasta su posible osteointegración...
Resumo:
General note: Title and date provided by Bettye Lane.
Resumo:
General note: Title and date provided by Bettye Lane.
Resumo:
General note: Title and date provided by Bettye Lane.