994 resultados para mass-wind coupling
Resumo:
This paper analyses the boundaries of simplified wind turbine models used to represent the behavior of wind turbines in order to conduct power system stability studies. Based on experimental measurements, the response of recent simplified (also known as generic) wind turbine models that are currently being developed by the International Standard IEC 61400-27 is compared to complex detailed models elaborated by wind turbine manufacturers. This International Standard, whose Technical Committee was convened in October 2009, is focused on defining generic simulation models for both wind turbines (Part 1) and wind farms (Part 2). The results of this work provide an improved understanding of the usability of generic models for conducting power system simulations.
Resumo:
INTRODUCTION: The Global Programme to Eliminate Lymphatic Filariasis was launched with the goal of eliminating this disease via the annual mass drug administration (MDA) of a single dose of antifilarial drugs. Adverse drug reactions following MDA are a major factor of poor treatment adherence in several countries. This study assessed the occurrence of adverse drug reactions (ADRs) following the first round of mass treatment in two communities treated with different dosages of diethylcarbamazine (DEC) in the City of Recife, Brazil. METHODS: Population-based cross-sectional surveys were conducted in a random sample of the population living in both communities (Areas I and II). The dose of DEC recommended by the WHO (6mg/kg) was calculated based on the individual's weight-for-age. In Area II, weight differences between the genders were also considered when determining dosage. Data were obtained through interviews conducted in the first 12 to 48h and on the 5th day after MDA during household visits. RESULTS: A total of 487 and 365 individuals were interviewed in Areas I and II, respectively. The prevalence of ADRs in Area I (23.6; 95%CI: 19.1-29.5) was higher than in Area II (16.2; 95%CI:11.9-21.5)(p=0.0078). The prevalence of ADRs among females was higher than in males in Area I (p=0.0021). In Area II, no significant difference between the genders was observed (p=0.1840). Age was not associated with ADRs in either area. CONCLUSIONS: Adjusting MDA dosage schedules according to weight-for-age and sex may be may contribute to reduce the occurrence of adverse drug reactions in the population.
Resumo:
Field lab: Consulting lab
Resumo:
OBJECTIVE: To determine the prevalence of systemic hypertension, diabetes mellitus, hypercholesterolemia, and hypertriglyceridemia in a Brazilian population in relation to body mass index. METHOD: Retrospective evaluation of 1213 adults (mean age: 45.2 ± 12.8; 80.6% females) divided into groups according to body mass index [normal (18.5 - 24.4 kg/m²); overweight (25 - 29.9 kg/m²); grade 1 obesity (30 - 34.9 kg/m²); grade 2 obesity (35 - 39.9 kg/m²), and grade 3 obesity (> 40 kg/m²)]. The prevalence of hypertension, diabetes mellitus, hypercholesterolemia, and hypertriglyceridemia were analyzed in each group. The severity of cardiovascular risk was determined. High-risk patients were considered those reporting 2 or more of the following factors: systemic hypertension, HDL < 35 mg/dL, total cholesterol > 240 mg/dL, triglycerides > 200 mg/dL when HDL < 35 mg/dL, and glycemia > 126 mg/dL. Moderate-risk patients were those reporting 2 or more of the following factors: systemic hypertension, HDL < 45, triglycerides > 200 mg/dL, and total cholesterol > 200 mg/dL. RESULTS: The prevalence of systemic hypertension, diabetes mellitus, hypertriglyceridemia, and low HDL-cholesterol levels increased along with weight, but the prevalence of hypercholesterolemia did not. The odds ratio adjusted for gender and age, according to grade of obesity compared with patients with normal weight were respectively 5.9, 8.6, and 14.8 for systemic hypertension, 3.8, 5.8, and 9.2 for diabetes mellitus and 1.2, 1.3, and 2.6 for hypertriglyceridemia. We also verified that body mass index was positively related to cardiovascular high risk (P < .001) CONCLUSION: In our population, cardiovascular risk increased along with body mass index.
Resumo:
Umbilical nodes are rare. The metastatic involvement of the region was first described in 1846. Sister Mary Joseph was the first observer to establish the correlation between carcinomas and umbilical nodes. The umbilical node may be the sole presenting sign of cancer and is usually associated with advanced disease and poor prognosis. A 64-year-old woman, previously healthy, presented vague abdominal discomfort and a hard umbilical nodule for 1 week, which was first diagnosed as an incarcerated umbilical hernia. She underwent a new clinical assessment and biopsy. After immunohistochemical analysis and computerized tomography, she was diagnosed with pancreatic cancer. The clinical staging showed advanced disease with distant metastasis. She received palliative chemotherapy. After 8 months, she was alive in poor clinical condition. Clinical suspicion should lead to a careful additional evaluation whenever an umbilical nodule presents with malignant signs.
Resumo:
Microbial electrolysis cells (MECs) are an innovative and emerging technique based on the use of solid-state electrodes to stimulate microbial metabolism for wastewater treatment and simultaneous production of value-added compounds (such as methane). This research studied the performance of a two-chamber MEC in terms of organic matter oxidation (at the anode) and methane production (at the cathode). MEC‟s anode had been previously inoculated with an activated sludge, whereas the cathode chamber inoculum was an anaerobic sludge (containing methanogenic microorganisms). During the experimentation, the bioanode was continuously fed with synthetic solutions in anaerobic basal medium, at an organic load rate (OLR) of around 1 g L-1 d-1, referred to the chemical oxygen demand (COD). At the beginning (Run I), the feeding solution contained acetate and subsequently (Run II) it was replaced with a more complex solution containing soluble organic compounds other than acetate. For both conditions, the anode potential was controlled at -0.1 V vs. standard hydrogen electrode, by means of a potentiostat. During Run I, over 80% of the influent acetate was anaerobically oxidized at the anode, and the resulting electric current was recovered as methane at the cathode (with a cathode capture efficiency, CCE, accounting around 115 %). The average energy efficiency of the system (i.e., the energy captured into methane relative to the electrical energy input) under these conditions was over 170%. However, reactor‟s performance decreased over time during this run. Throughout Run II, a substrate oxidation over 60% (on COD basis) was observed. The electric current produced (57% of coulombic efficiency) was also recovered as methane, with a CCE of 90%. For this run the MEC‟s average energy efficiency accounted for almost 170 %. During all the experimentation, a very low biomass growth was observed at the anode whereas ammonium was transferred through the cationic membrane and concentrated at the cathode. Tracer experiments and scanning electron microscopy analyses were also carried out to gain a deeper insight into the reactor performance and also to investigate the possible reasons for partial loss of performance. In conclusion, this research suggests the great potential of MEC to successfully treat low-strength wastewaters, with high energy efficiency and very low sludge production.
Resumo:
The leaf-feeding species Syntermes molestus and S. spinosus are two dominant termite species in Reserva Ducke in Central Amazonia; two other species (S. aculeosus, S. longiceps) exist in the area. All species except S. aculeosus were also found in urban areas. The workers of S. molestus and S. spinosus have average body dry weights of 4.5±0.2 and 13.1±1.4 mg, and the weight of their soldiers is 8.2±0.2 and 51.0±1.7 mg, respectively. Therefore, S. spinosus is among the largest termites of the world. In both species, fresh weight is about 4.7 higher than dry weight (a wider relation than in other termite species). The biomass of the populations of both species amounted to about 1 g m-2 (dry weight; indirect estimate), which rises previous assessments of the total termite biomass by about 36-45%, to a value of 3.0-3.5 g m-2.
Resumo:
The Our Lady of Conception church is located in village of Monforte (Portugal) and is not in use nowadays. The church presents structural damage and, consequently, a study was carried out. The study involved the survey of the damage, dynamic identification tests under ambient vibration and the numerical analysis. The church is constituted by the central nave, the chancel, the sacristy and the corridor to access the pulpit. The masonry walls present different thickness, namely 0.65 m in the chancel, 0.70 m in the sacristy, 0.92 in the central nave and 0.65 m in the corridor. The masonry walls present 8 buttresses with different dimensions. The total longitudinal and transversal dimensions of the church are equal to 21.10 m and 14.26 m, respectively. The survey of the damage showed that, in general, the masonry walls are in good conditions, with exception of the transversal walls of the nave, which present severe cracks. The arches of the vault presents also severe cracks along the central nave. As consequence, the infiltrations have increased the degradation of the vault and paintings. Furthermore, the foundations present settlements in the Southwest direction. The dynamic identification test were carried out under the action of ambient excitation of the wind and using 12 piezoelectric accelerometers of high sensitivity. The dynamic identification tests allowed to estimate the dynamic properties of the church, namely frequencies, mode shapes and damping ratios. A FEM numerical model was prepared and calibrated, based on the first four experimental modes estimated in the dynamic identification tests. The average error between the experimental and numerical frequencies of the first four modes is equal to 5%. After calibration of the numerical model, pushover analyses with a load pattern proportional to the mass, in the transversal and longitudinal direction of the church, were performed. The results of the analysis numerical allow to conclude that the most vulnerable direction of the church is in the transversal one and the maximum load factor is equal to 0.35.
Resumo:
The RMR system is still very much applied in rock mechanics engineering context. It is based on the evaluation of six weights to obtain a final rating. To obtain the final rating a considerable amount of information is needed concerning the rock mass which can be difficult to obtain in some projects or project stages at least with accuracy. In 2007 an alternative classification scheme based on the RMR, the Hierarchical Rock Mass Rating (HRMR) was presented. The main feature of this system was the adaptation to the level of knowledge existent about the rock mass to obtain the classification of the rock mass since it followed a decision tree approach. However, the HRMR was only valid for hard rock granites with low fracturing degrees. In this work, the database was enlarged with approximately 40% more cases considering other types of granite rock masses including weathered granites and based on this increased database the system was updated. Granite formations existent in the north of Portugal including Porto city are predominantly granites. Some years ago a light rail infrastructure was built in the city of Porto and surrounding municipalities whi h involved considerable challenges due to the high heterogeneity levels of the granite formations and the difficulties involved in their geomechanical characterization. In this work it is intended to provide also a contribution to improve the characterization of these formations with special emphasis to the weathered horizons. A specific subsystem applicable to the weathered formations was developed. The results of the validation of these systems are presented and show acceptable performances in identifying the correct class using less information than with the RMR system.
Resumo:
The final ATLAS Run 1 measurements of Higgs boson production and couplings in the decay channel H→ZZ∗→ℓ+ℓ−ℓ′+ℓ′−, where ℓ,ℓ′=e or μ, are presented. These measurements were performed using pp collision data corresponding to integrated luminosities of 4.5 fb−1 and 20.3 fb−1 at center-of-mass energies of 7 TeV and 8 TeV, respectively, recorded with the ATLAS detector at the LHC. The H→ZZ∗→4ℓ signal is observed with a significance of 8.1 standard deviations at 125.36 GeV, the combined ATLAS measurement of the Higgs boson mass from the H→γγ and H→ZZ∗→4ℓ channels. The production rate relative to the Standard Model expectation, the signal strength, is measured in four different production categories in the H→ZZ∗→4ℓ channel. The measured signal strength, at this mass, and with all categories combined, is 1.44 +0.40−0.33. The signal strength for Higgs boson production in gluon fusion or in association with tt¯ or bb¯ pairs is found to be 1.7 +0.5−0.4, while the signal strength for vector-boson fusion combined with WH/ZH associated production is found to be 0.3 +1.6−0.9.
Resumo:
This article describes a search for high-mass resonances decaying to a pair of photons using a sample of 20.3 fb−1 of pp collisions at s√=8 TeV recorded with the ATLAS detector at the Large Hadron Collider. The data are found to be in agreement with the Standard Model prediction, and limits are reported in the framework of the Randall-Sundrum model. This theory leads to the prediction of graviton states, the lightest of which could be observed at the Large Hadron Collider. A lower limit of 2.66 (1.41) TeV at 95% confidence level is set on the mass of the lightest graviton for couplings of k/M¯¯¯¯Pl=0.1 (0.01).
Resumo:
Since the last two decades mass spectrometry (MS) has been applied to analyse the chemical cellular components of microorganisms, providing rapid and discriminatory proteomic profiles for their species identification and, in some cases, subtyping. The application of MS for the microbial diagnosis is currently well-established. The remarkable reproducibility and objectivity of this method is based on the measurement of constantly expressed and highly abundant proteins, mainly important conservative ribosomal proteins, which are used as markers to generate a cellular fingerprint. Mass spectrometry based on matrix-assisted laser desorption ionization-time of flight (MALDI- TOF) technique has been an important tool for the microbial diagnostic. However, some technical limitation concerning both MALDI-TOF and its used protocols for sample preparation have fostered the research of new mass spectrometry systems (e.g. LC MS/MS). LC MS/MS is able to generate online mass spectra of specific ions with further online sequencing of these ions, which include both specific proteins and DNA fragments. In this work a set of data for yeasts and filamentous fungi diagnostic obtained through an international collaboration project involving partners from Argentina, Brazil, Chile and Portugal will be presented and discussed.
Resumo:
This paper deals with the problem of estimation maintenance costs for the case of the pitch controls system of wind farms turbines. Previous investigations have estimated these costs as (traditional) “crisp” values, simply ignoring the uncertainty nature of data and information available. This paper purposes an extended version of the estimation model by making use of the Fuzzy Set Theory. The results alert decision-makers to consequent uncertainty of the estimations along with their overall level, thus improving the information given to the mainte-nance support system.
Resumo:
Wind tunnel tests are a reliable tool to determine the effect of natural ventilation on buildings. This paper presents results of wind tunnel tests conducted to evaluate the influence of ventilation modules positioning on a façade system. Modules positioning was modified, resulting in different façade configurations. The tests were carried out with the use of a model, varying the position of the ventilation modules in the façade configuration. The cases tested were six ventilation modules positioned below the window-sill (ventilated window-sill), and three ventilation modules positioned above and below the façade. The façade system proposed was movable and interchangeable so that the same basic model could be used to test the possibilities for ventilation. Wind speed measurements were taken inside and outside the model for the different façades configurations to evaluate the best performance in relation to natural ventilation. Singleâ sided and Cross ventilation were considered for wind speed measurements. Results show the use of six ventilation modules positioned below the window-sill, forming "a ventilated window-sill" is the best solution in terms of natural ventilation.