781 resultados para fluorescein angiography


Relevância:

10.00% 10.00%

Publicador:

Resumo:

We showed recently that low molecular weight dextran sulfate (DXS) acts as an endothelial cell (EC) protectant and prevents human complement- and NK cell-mediated cytotoxicity towards porcine cells in vitro. We therefore hypothesized that DXS, combined with cyclosporine A (CyA), could prevent acute vascular rejection (AVR) in the hamster-to-rat cardiac xenotransplantation model. Untreated, CyA-only, and DXS-only treated rats rejected their grafts within 4-5 days. Of the hearts grafted into rats receiving DXS in combination with CyA, 28% survived more than 30 days. Deposition of anti-hamster antibodies and complement was detected in long-term surviving grafts. Combined with the expression of hemoxygenase 1 (HO-1) on graft EC, these results indicate that accommodation had occurred. Complement activity was normal in rat sera after DXS injection, and while systemic inhibition of the coagulation cascade was observed 1 h after DXS injection, it was absent after 24 h. Moreover, using a fluorescein-labeled DXS (DXS-Fluo) injected 1 day after surgery, we observed a specific binding of DXS-Fluo to the xenograft endothelium. In conclusion, we show here that DXS + CyA induces long-term xenograft survival and we provide evidence that DXS might act as a local EC protectant also in vivo.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE OF REVIEW: Current guidelines for the management of acute coronary syndrome clearly recommend that clopidogrel should be started before diagnostic coronary angiography. If patients undergo coronary artery bypass grafting (CABG) early after clopidogrel loading or during continued exposure, it seems reasonable to expect an increase in bleeding complications. RECENT FINDINGS: Earlier studies may have overestimated the risk of bleeding in patient undergoing CABG with prior clopidogrel exposure (5-10-fold increase). Some conflicting results are reported in literature. As reexploration because of excessive bleeding is concerned, a two to three-fold increase must be expected, which is demonstrated in actual trials properly matched to confounding factors. Discontinuation of clopidogrel for 5-7 days prior to urgent CABG as recommended by guidelines is not well adopted in clinical practice for several reasons. SUMMARY: There is a moderately elevated risk of bleeding complications after CABG due to prior clopidogrel exposure alone. However, in clinical practice this risk is added often to patients who carry already elevated surgical risks (urgent procedures, worse coronary anatomy, history of previous myocardial infarction and prior percutaneous intervention), and after bleeding complications singular patients may suffer from consecutive adverse outcome. Cessation of clopidogrel in patients before CABG clearly prolongs hospitalization time and has an estimated 1% risk of coronary events during the waiting period. Risk and benefit have to be balanced in every individual case.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Cystic adventitial degeneration is a rare non-atherosclerotic cause of peripheral arterial occlusive disease, mainly seen in young men without other evidence of vascular disease. Diagnosis will be established by clinical findings and by ultrasound or angiography and can be treated by excision or enucleation of the affected arterial segment or by percutaneous ultrasound-guided aspiration. However, the etiology of adventitial cysts remains unknown. We report a case of cystic adventitial degeneration showing a connection between the joint capsule and the adventitial cyst, supporting the theory that cystic adventitial degeneration may represent ectopic ganglia from adjacent joint capsules.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Maintenance of intestinal epithelial barrier function is of vital importance in preventing uncontrolled influx of antigens and the potentially ensuing inflammatory disorders. Intestinal intraepithelial lymphocytes (IEL) are in intimate contact with epithelial cells and may critically regulate the epithelial barrier integrity. While a preserving impact has been ascribed to the T-cell receptor (TCR)-gammadelta subset of IEL, IEL have also been shown to attenuate the barrier function. The present study sought to clarify the effects of IEL by specifically investigating the influence of the TCR-alphabeta CD8alphabeta and TCR-alphabeta CD8alphaalpha subsets of IEL on the intestinal epithelial barrier integrity. To this end, an in vitro coculture system of the murine intestinal crypt-derived cell-line mIC(cl2) and syngeneic ex vivo isolated IEL was employed. Epithelial integrity was assessed by analysis of transepithelial resistance (TER) and paracellular flux of fluorescein isothiocyanate-conjugated (FITC-) dextran. The TCR-alphabeta CD8alphaalpha IEL and resting TCR-alphabeta CD8alphabeta IEL did not affect TER of mIC(cl2) or flux of FITC-dextran. In contrast, activated TCR-alphabeta CD8alphabeta IEL clearly disrupted the integrity of the mIC(cl2) monolayer. No disrupting effect was seen with activated TCR-alphabeta CD8alphabeta IEL from interferon-gamma knockout mice. These findings demonstrate that secretion of interferon-gamma by activated TCR-alphabeta CD8alphabeta IEL is strictly required and also sufficient for disrupting the intestinal epithelial barrier function.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Computer-aided microscopic surgery of the lateral skull base is a rare intervention in daily practice. It is often a delicate and difficult minimally invasive intervention, since orientation between the petrous bone and the petrous bone apex is often challenging. In the case of aural atresia or tumors the normal anatomical landmarks are often absent, making orientation more difficult. Navigation support, together with imaging techniques such as CT, MR and angiography, enable the surgeon in such cases to perform the operation more accurately and, in some cases, also in a shorter time. However, there are no internationally standardised indications for navigated surgery on the lateral skull base. Miniaturised robotic systems are still in the initial validation phase.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: The purpose of this study was to delineate the anatomy of the precentral cerebellar vein, superior vermian vein, and internal occipital vein using reconstructions of computed tomographic and magnetic resonance imaging scans with navigation software. These data were compared with previous anatomic and angiographic findings to show the resolution and accuracy of the system. METHODS: We retrospectively reviewed 100 patients with intracranial pathologies (50 computed tomographic scans with contrast and 50 magnetic resonance imaging scans with gadolinium) using a neuronavigation workstation for 3-dimensional reconstruction. Particular attention was paid to depiction of the precentral cerebellar vein, superior vermian vein, and internal occipital vein. The data were reviewed and analyzed. RESULTS: The precentral cerebellar vein, superior vermian vein, and its tributary, the supraculminate vein, were depicted in 52 (52%) patients. The internal occipital vein was delineated on 99 (49.5%) sides and joined the basal vein and vein of Galen in 39 (39.4%) and 60 (60.6%) hemispheres, respectively. Comparing these results with previous angiographic studies, the ability of the neuronavigation system for depicting these vessels is similar to that of digital subtraction angiography. CONCLUSION: This study illustrates the possibility of depicting the small vessels draining into the pineal region venous complex using 3-dimensional neuronavigation with an accuracy comparable to that of digital subtraction angiography. This tool provides important information for both surgical planning and intraoperative orientation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECT: Preliminary experience with the C-Port Flex-A Anastomosis System (Cardica, Inc.) to enable rapid automated anastomosis has been reported in coronary artery bypass surgery. The goal of the current study was to define the feasibility and safety of this method for high-flow extracranial-intracranial (EC-IC) bypass surgery in a clinical series. METHODS: In a prospective study design, patients with symptomatic carotid artery (CA) occlusion were selected for C-Port-assisted high-flow EC-IC bypass surgery if they met the following criteria: 1) transient or moderate permanent symptoms of focal ischemia; 2) CA occlusion; 3) hemodynamic instability; and 4) had provided informed consent. Bypasses were done using a radial artery graft that was proximally anastomosed to the superficial temporal artery trunk, the cervical external, or common CA. All distal cerebral anastomoses were performed on M2 branches using the C-Port Flex-A system. RESULTS: Within 6 months, 10 patients were enrolled in the study. The distal automated anastomosis could be accomplished in all patients; the median temporary occlusion time was 16.6+/-3.4 minutes. Intraoperative digital subtraction angiography (DSA) confirmed good bypass function in 9 patients, and in 1 the anastomosis was classified as fair. There was 1 major perioperative complication that consisted of the creation of a pseudoaneurysm due to a hardware problem. In all but 1 case the bypass was shown to be patent on DSA after 7 days; furthermore, in 1 patient a late occlusion developed due to vasospasm after a sylvian hemorrhage. One-week follow-up DSA revealed transient asymptomatic extracranial spasm of the donor artery and the radial artery graft in 1 case. Two patients developed a limited zone of infarction on CT scanning during the follow-up course. CONCLUSIONS: In patients with symptomatic CA occlusion, C-Port Flex-A-assisted high-flow EC-IC bypass surgery is a technically feasible procedure. The system needs further modification to achieve a faster and safer anastomosis to enable a conclusive comparison with standard and laser-assisted methods for high-flow bypass surgery.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: The role of endothelin-1 (ET-1) and nitric oxide (NO) as two important mediators in the development of cerebral vasospasm (CVS) after subarachnoid haemorrhage (SAH) is controversial. The objective of this study was to determine whether local levels of ET-1 and NO in cerebral arterial plasma and/or in cerebrospinal fluid (CSF) are associated with the occurrence of CVS after SAH. METHODS: CVS was induced using the one-haemorrhage rabbit model and confirmed by digital subtraction angiography of the rabbits' basilar artery on day 5. Prior to sacrifice, local CSF and basilar arterial plasma samples were obtained by a transclival approach to the basilar artery. Systemic arterial plasma samples were obtained. ET-1 levels were determined by immunometric technique (pg/ml +/- SEM) and total nitrate/nitrite level spectrophotometrically (micromol/l +/- SEM). FINDINGS: Angiographic CVS was documented after SAH induction (n = 12, P < 0.05). The ET-1 level in CSF was significantly elevated by 27.3% to 0.84 +/- 0.08 pg/ml in SAH animals (n = 7) in comparison to controls (0.66 +/- 0.04 pg/ml, n = 7, P < 0.05). There was no significant difference in ET-1 levels in systemic and basilar arterial plasma samples of SAH animals compared to controls. A significant lack of local NO metabolites was documented in basilar arterial plasma after SAH (36.8 +/- 3.1 micromol/l, n = 6) compared to controls (61.8 +/- 6.2 micromol/l, n = 6, P < 0.01). CONCLUSION: This study demonstrates that an elevated ET-1 level in CSF and local lack of NO in the basilar arterial plasma samples are associated with CVS after experimental SAH.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: Mitogen-activated protein kinases (MAPKs), including JNK, p38, and ERK1/2, noticeably influence ischemia/reperfusion injury (IRI). The complement inhibitor dextran sulfate (DXS) associates with damaged endothelium denudated of its heparan sulfate proteoglycan (HSPG) layer. Other glycosaminoglycan analogs are known to influence MAPK signaling. Hypothetically therefore, targeted intravascular cytoprotection by DXS may function in part through influencing MAPK activation to reduce IRI-induced damage of the vasculature. METHODS: IRI of the infrarenal aorta of male Wistar rats was induced by 90 minutes clamping followed by 120 minutes reperfusion. DXS (5 mg/mL) or physiologic saline (NaCl controls) was infused locally into the ischemic aortic segment immediately prior to reperfusion. Ninety minutes ischemia-only and heparinase infusion (maximal damage) experiments, as well as native rat aorta, served as controls. Aortas were excised following termination of the experiments for further analysis. RESULTS: DXS significantly inhibited IRI-induced JNK and ERK1/2 activation (P = .043; P =.005) without influencing the p38 pathway (P =.110). Reduced aortic injury, with significant inhibition of apoptosis (P = .032 for DXS vs NaCl), correlated with decreased nuclear factor kappaB translocation within the aortic wall. DXS treatment clearly reduced C1q, C4b/c, C3b/c, and C9 complement deposition, whilst preserving endothelial cell integrity and reducing reperfusion-induced HSPG shedding. Protection was associated with binding of fluorescein labeled DXS to ischemically damaged tissue. CONCLUSIONS: Local application of DXS into ischemic vasculature immediately prior to reperfusion reduces complement deposition and preserves endothelial integrity, partially through modulating activation of MAPKs and may offer a new approach to tackle IRI in vascular surgical procedures. CLINICAL RELEVANCE: The purpose of the present study was to determine the role of dextran sulfate (DXS), a glycosaminoglycan analog and complement inhibitor, in modulating intracellular MAPK signaling pathways, reducing complement activation and ultimately attenuating ischemia/reperfusion injury (IRI) in a rat aortic-clamping model, in part a surrogate model to study the microvasculature. The study shows a role for DXS in ameliorating endothelial injury by reducing IRI-mediated damage and intravascular, local inflammation in the affected aortic segment. DXS may be envisaged as an endothelial protectant in vascular injury, such as occurs during vascular surgical procedures.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Angiopoietin-2 (Ang-2) antagonises the maturing effect of angiopoietin-1 (Ang-1) on blood vessels, and cooperates with VEGF to induce neovascularisation. In knockout mice, Ang-2 displayed a specific role in postnatal angiogenic remodelling. Here, we demonstrate that mice deficient in Ang-2 fail to form a proper spatial retinal vascular network. The retinal vasculature was characterised by reduced large vessel numbers and defects forming the superficial periphery mostly on the arteriolar site, and the secondary and tertiary deep capillary network. Hypoxia in the retinal periphery induced a four-fold VEGF upregulation and active endothelial proliferation for up to 60 days. Concomitantly, retinal digest preparations showed increased arteriolar (+33%) and capillary diameters (+90%), and fluorescein angiograms revealed leakiness of neovascular front. At one year of age, persistent preretinal vessels were non-leaky in accordance with a relative increase in the ratio of Ang-1 to VEGF. Taken together, the data suggest that Ang-2 has an important function in the spatial configuration of the three-dimensional retinal vasculature. Secondarily, prolonged VEGF activity results in a model of persistent proliferative retinopathy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: It is unclear whether very old patients benefit from organized inpatient (stroke unit) care. The aim of this work was to compare the clinical outcome of patients with first-ever ischemic stroke aged either >or=80 or <80 years who were treated conservatively (without cerebral revascularization) in a university-based stroke unit. PATIENTS AND METHODS: We included 147 (11%) patients >or=80 years and 1241 (89%) patients, <80 years. All patients underwent clinical examination, blood tests, electrocardiography (ECG), brain imaging and cerebrovascular ultrasound. Additional investigations were done at the discretion of the treating physician. The modified Rankin scale (mRS) score was used to assess the 3-month outcome (favorable: mRS, 0-1; poor: mRS, 2-6; death of any cause). RESULTS: Stroke severity did not differ between both groups [median National Institutes of Health Stroke Scale (NIHSS) score, 4]. Younger patients underwent magnetic resonance (MR) imaging of the brain, MR and catheter angiography and echocardiography (p<0.001) more frequently, whereas older patients underwent computed tomography of the brain and 24-hour ECG (p<0.001) more frequently. Stroke prevention included clopidogrel (p<0.001) and heparin (p=0.047) more often in older patients and aspirin (p=0.016) in younger patients. Recurrent ischemic events were similarly frequent in old (7%) and young (5%) patients. Favorable outcome was equally prevalent in old (71%) and young (76%) patients, whereas mortality was higher in older patients (7 and 3%, p=0.007). Admission NIHSS score >or=12 was the only independent predictor of unfavorable outcome (odds ratio, 19.6; 95% confidence interval, 9.7-39.6; p<0.001). CONCLUSION: Our work provides further evidence that also the oldest patients may benefit from conservative stroke unit care.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

CONTEXT: Death from corpora aliena in the larynx is a well-known entity in forensic pathology. The correct diagnosis of this cause of death is difficult without an autopsy, and misdiagnoses by external examination alone are common. OBJECTIVE: To determine the postmortem usefulness of modern imaging techniques in the diagnosis of foreign bodies in the larynx, multislice computed tomography, magnetic resonance imaging, and postmortem full-body computed tomography-angiography were performed. DESIGN: Three decedents with a suspected foreign body in the larynx underwent the 3 different imaging techniques before medicolegal autopsy. RESULTS: Multislice computed tomography has a high diagnostic value in the noninvasive localization of a foreign body and abnormalities in the larynx. The differentiation between neoplasm or soft foreign bodies (eg, food) is possible, but difficult, by unenhanced multislice computed tomography. By magnetic resonance imaging, the discrimination of the soft tissue structures and soft foreign bodies is much easier. In addition to the postmortem multislice computed tomography, the combination with postmortem angiography will increase the diagnostic value. CONCLUSIONS: Postmortem, cross-sectional imaging methods are highly valuable procedures for the noninvasive detection of corpora aliena in the larynx.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To evaluate a widely used nontunneled triple-lumen central venous catheter in order to determine whether the largest of the three lumina (16 gauge) can tolerate high flow rates, such as those required for computed tomographic angiography. MATERIALS AND METHODS: Forty-two catheters were tested in vitro, including 10 new and 32 used catheters (median indwelling time, 5 days). Injection pressures were continuously monitored at the site of the 16-gauge central venous catheter hub. Catheters were injected with 300 and 370 mg of iodine per milliliter of iopamidol by using a mechanical injector at increasing flow rates until the catheter failed. The infusion rate, hub pressure, and location were documented for each failure event. The catheter pressures generated during hand injection by five operators were also analyzed. Mean flow rates and pressures at failure were compared by means of two-tailed Student t test, with differences considered significant at P < .05. RESULTS: Injections of iopamidol with 370 mg of iodine per milliliter generate more pressure than injections of iopamidol with 300 mg of iodine per milliliter at the same injection rate. All catheters failed in the tubing external to the patient. The lowest flow rate at which catheter failure occurred was 9 mL/sec. The lowest hub pressure at failure was 262 pounds per square inch gauge (psig) for new and 213 psig for used catheters. Hand injection of iopamidol with 300 mg of iodine per milliliter generated peak hub pressures ranging from 35 to 72 psig, corresponding to flow rates ranging from 2.5 to 5.0 mL/sec. CONCLUSION: Indwelling use has an effect on catheter material property, but even for used catheters there is a substantial safety margin for power injection with the particular triple-lumen central venous catheter tested in this study, as the manufacturer's recommendation for maximum pressure is 15 psig.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND AND AIMS: The splanchnic circulation has an important function in the body under both physiological and pathophysiological conditions. Despite its importance, no reliable noninvasive procedures for estimating splanchnic circulation have been established. The aim of this study was to evaluate MRI as a tool for assessing intra-abdominal blood flows of the aorta, portal vein (VPO) and the major intestinal and hepatic vessels. METHODS: In nine healthy volunteers, the proximal aorta (AOP) and distal abdominal aorta (AOD), superior mesenteric artery (SAM), celiac trunk (CTR), hepatic arteries (common and proper hepatic arteries, AHC and AHP, respectively), and VPO were localized on contrast-enhanced magnetic resonance angiography images. Volumetric flow was measured using a two-dimensional cine echocardiogram-gated phase contrast technique. Measurements were taken before and 30 min after continuous intravenous infusion of somatostatin (250 microg/h) and were independently evaluated by two investigators. RESULTS: Blood flow measured by MRI in the VPO, SAM, AOP, AHP, and CTR significantly decreased after drug infusion. Flows in the AOD and AHC showed a tendency to decrease (P>0.05). Interrater agreement on flows in MRI was very good for large vessels (VPO, AOP, and AOD), with a concordance correlation coefficient of 0.94, as well as for smaller vessels such as the CTR, AHC, AHP, and SAM (concordance correlation coefficient =0.78). CONCLUSION: Somatostatin-induced blood flow changes in the splanchnic region were reliably detected by MRI. MRI may be useful for the noninvasive assessment of blood flow changes in the splanchnic region.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: A precise, non-invasive, non-toxic, repeatable, convenient and inexpensive follow-up of renal transplants, especially following biopsies, is in the interest of nephrologists. Formerly, the rate of biopsies leading to AV fistulas had been underestimated. Imaging procedures suited to a detailed judgement of these vascular malformations are to be assessed. METHODS: Three-dimensional (3D) reconstruction techniques of ultrasound flow-directed and non-flow-directed energy mode pictures were compared with a standard procedure, gadolinium-enhanced nuclear magnetic resonance imaging angiography (MRA) using the phase contrast technique. RESULTS: Using B-mode and conventional duplex information, AV fistulas were localized in the upper pole of the kidney transplant of the index patient. The 3D reconstruction provided information about the exact localization and orientation of the fistula in relation to other vascular structures, and the flow along the fistula. The MRA provided localization and orientation information, but less functional information. Flow-directed and non-flow-directed energy mode pictures could be reconstructed to provide 3D information about vascular malformations in transplanted kidneys. CONCLUSION: In transplanted kidneys, 3D-ultrasound angiography may be equally as effective as MRA in localizing and identifying AV malformations. Advantages of the ultrasound method are that it is cheaper, non-toxic, non-invasive, more widely availability and that it even provides more functional information. Future prospective studies will be necessary to evaluate the two techniques further.