Ionic polymer conductive network composite (IPCNC) actuators are a class of electroactive polymer composites that exhibit some interesting electromechanical characteristics such as low voltage actuation, large displacements, and benefit from low density and elastic modulus. Thus, these emerging materials have potential applications in biomimetic and biomedical devices. Whereas significant efforts have been directed toward the development of IPMC actuators, the establishment of a proper mathematical model that could effectively predict the actuators' dynamic behavior is still a key challenge. This paper presents development of an effective modeling strategy for dynamic analysis of IPCNC actuators undergoing large bending deformations. The proposed model is composed of two parts, namely electrical and mechanical dynamic models. The electrical model describes the actuator as a resistive-capacitive (RC) transmission line, whereas the mechanical model describes the actuator as a system of rigid links connected by spring-damping elements. The proposed modeling approach is validated by experimental data, and the results are discussed. © 2014 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

 Yield function has various material parameters that describe how materials respond plastically in given conditions. However, a significant number of mechanical tests are required to identify the many material parameters for yield function. In this study, an effective method using crystal plasticity through a virtual experiment is introduced to develop the anisotropic yield function for AA5042. The crystal plasticity approach was used to predict the anisotropic response of the material in order to consider a number of stress or strain modes that would not otherwise be evident through mechanical testing. A rate-independent crystal plasticity model based on a smooth single crystal yield surface, which removes the innate ambiguity problem within the rate-independent model and Taylor model for polycrystalline deformation behavior were employed to predict the material’s response in the balanced biaxial stress, pure shear, and plane strain states to identify the parameters for the anisotropic yield function of AA5042.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper uses the finite element upper and lower bound limit analysis to assess the stability of slopes mostly found in embankment cases where frictional materials are filled on purely cohesive undrained clay. For comparison purposes, the commonly used stability assessment method, limit equilibrium method (LEM) is also employed. The final results for both methods are then presented in the form of comprehensive chart solutions for the convenience of practicing engineers during preliminary slope designs. The failure mechanism will also be discussed in this paper. Ultimately, it should be noted that finite element limit analysis method holds the upper hand as its prior assumptions are not required. Thus, the obtained failure mechanism from the slope stability analysis will be more realistic. Hence, it will provide a better understanding for the slope failure surface. Therefore, engineers should design more carefully when the LEM is applied to the slopes with frictional materials filled on purely cohesive undrained clay. © 2014 American Society of Civil Engineers.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Thrombotic stroke, which is caused by blood clot in the cerebral artery, is a major source of increased mortality and morbidity. Considering as efficient and fastest methods, mathematical approaches have gained significant importance for analyzing and understanding the biological events like thrombosis. This paper presents a computational model to analyze the effects of thrombosis using the theory of coupled fluid dynamics-structure interaction. The finite element method is used for the modeling of thrombosis (blood clot) of different stages in the middle cerebral artery with physiological compliance. The developed model is used to investigate the consequences that occur due to the various sizes of clots in the artery in the form of blood flow velocity, blood pressure, and artery wall stress. Such numerical assessment will facilitate better understanding of the biophysical process in case of thrombosis and thus would support medical practitioners to take faster curing steps.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Al and Mg alloys are widely used in industry as main lightweight alloys. They have excellent properties, such as low density, high ductility, and high specific strength, and so on. Generally speaking, Mg alloys are better than Al alloys. However the corrosion of Mg alloys is much more difficult to control compared Al alloys. Therefore to combine these two lightweight alloys, a composite-like structure is an ideal solution since Al alloys can be used as protective coatings for Mg alloys. Compound casting is a realistic technique to get this coating system. In the current study, we numerically study the compound casting using finite element method (FEM) to make these two alloys, a composite-like structure, satisfy requirements to resist corrosion required from industry, in which the aluminum layer is acting as a protective coating for the magnesium substrate. Several finite element models have been developed by using the birth and death element technique and we focus on compound casting-induced residual stresses in the compounded structure. The numerical results obtained from the proposed finite element models show the distribution profiles of thermal residual stresses. We found the major factors influencing the residual stresses are the temperature to pre-heating the Al substrate and the thickness of Mg deposits. © (2014) Trans Tech Publications, Switzerland.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Stability charts for soil slopes, first produced in the first half of the twentieth century, continue to be used extensively as design tools, and draw the attention of many investigators. This paper uses finite-element upper and lower bound limit analysis to assess the short-term stability of slopes in which the slopematerial and subgrade foundation material have two distinctly different undrained strengths. The stability charts are proposed, and the exact theoretical solutions are bracketed to within 4.2% or better. In addition, results from the limit-equilibrium method (LEM) have been used for comparison. Differences of up to 20% were found between the numerical limit analysis and LEM solutions. It also shown that the LEM sometimes leads to errors, although it is widely used in practice for slope stability assessments.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The dispersion of pollutants in the environment is an issue of great interest as it directly affects air quality, mainly in large cities. Experimental and numerical tools have been used to predict the behavior of pollutant species dispersion in the atmosphere. A software has been developed based on the control-volume based on the finite element method in order to obtain two-dimensional simulations of Navier-Stokes equations and heat or mass transportation in regions with obstacles, varying position of the pollutant source. Numeric results of some applications were obtained and, whenever possible, compared with literature results showing satisfactory accordance. Copyright (C) 2010 John Wiley & Sons, Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work presents a numerical study of the tri-dimensional convection-diffusion equation by the control-volume-based on finite-element method using quadratic hexahedral elements. Considering that the equation governing this problem in its main variable may represent several properties, including temperature, turbulent kinetic energy, viscous dissipation rate of the turbulent kinetic energy, specific dissipation rate of the turbulent kinetic energy, or even the concentration of a contaminant in a given medium, among others, the wide applicability of this problem is thus evidenced. Three cases of temperature distributions will be studied specifically in this work, in addition to one case of pollutant dispersion upon analysis of the concentration of a contaminant in a fixed flow point. Some comparisons will be carried out against works found in the open literature, while others will be done according to each phenomenon characteristics.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study aimed to develop a plate to treat fractures of the mandibular body in dogs and to validate the project using finite elements and biomechanical essays. Mandible prototypes were produced with 10 oblique ventrorostral fractures (favorable) and 10 oblique ventrocaudal fractures (unfavorable). Three groups were established for each fracture type. Osteosynthesis with a pure titanium plate of double-arch geometry and blocked monocortical screws offree angulanon were used. The mechanical resistance of the prototype with unfavorable fracture was lower than that of the fcworable fracture. In both fractures, the deflection increased and the relative stiffness decreased proportionally to the diminishing screw number The finite element analysis validated this plate study, since the maximum tension concentration observed on the plate was lower than the resistance limit tension admitted by the titanium. In conclusion, the double-arch geometry plate fixed with blocked monocortical screws has sufficient resistance to stabilize oblique,fractures, without compromising mandibular dental or neurovascular structures. J Vet Dent 24 (7); 212 - 221, 2010

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: The aim of this study was to assess the influence of cusp inclination on stress distribution in implant-supported prostheses by 3D finite element method.Materials and Methods: Three-dimensional models were created to simulate a mandibular bone section with an implant (3.75 mm diameter x 10 mm length) and crown by means of a 3D scanner and 3D CAD software. A screw-retained single crown was simulated using three cusp inclinations (10 degrees, 20 degrees, 30 degrees). The 3D models (model 10d, model 20d, and model 30d) were transferred to the finite element program NeiNastran 9.0 to generate a mesh and perform the stress analysis. An oblique load of 200 N was applied on the internal vestibular face of the metal ceramic crown.Results: The results were visualized by means of von Mises stress maps. Maximum stress concentration was located at the point of application. The implant showed higher stress values in model 30d (160.68 MPa). Cortical bone showed higher stress values in model 10d (28.23 MPa).Conclusion: Stresses on the implant and implant/abutment interface increased with increasing cusp inclination, and stresses on the cortical bone decreased with increasing cusp inclination.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to evaluate the influence of the platform-switching technique on stress distribution in implant, abutment, and pen-implant tissues, through a 3-dimensional finite element study. Three 3-dimensional mandibular models were fabricated using the Solid Works 2006 and InVesalius software. Each model was composed of a bone block with one implant 10 mm long and of different diameters (3.75 and 5.00 mm). The UCLA abutments also ranged in diameter from 5.00 mm to 4.1 mm. After obtaining the geometries, the models were transferred to the software FEMAP 10.0 for pre- and postprocessing of finite elements to generate the mesh, loading, and boundary conditions. A total load of 200 N was applied in axial (0 degrees), oblique (45 degrees), and lateral (90) directions. The models were solved by the software NeiNastran 9.0 and transferred to the software FEMAP 10.0 to obtain the results that were visualized through von Mises and maximum principal stress maps. Model A (implants with 3.75 mm/abutment with 4.1 mm) exhibited the highest area of stress concentration with all loadings (axial, oblique, and lateral) for the implant and the abutment. All models presented the stress areas at the abutment level and at the implant/abutment interface. Models B (implant with 5.0 mm/abutment with 5.0 mm) and C (implant with 5.0 mm/abutment with 4.1 mm) presented minor areas of stress concentration and similar distribution pattern. For the cortical bone, low stress concentration was observed in the pen-implant region for models B and C in comparison to model A. The trabecular bone exhibited low stress that was well distributed in models B and C. Model A presented the highest stress concentration. Model B exhibited better stress distribution. There was no significant difference between the large-diameter implants (models B and C).