999 resultados para elemental occurrence phase
Resumo:
Elemental and semi-elemental formulas are used to feed infants with short bowel syndrome, who may not be able to tolerate feeds of more than 310 mOsm kg(-1). The present study aimed to measure the osmolality of elemental and semi-elemental formulas at different concentrations, with and without the addition of nonprotein energy supplements.
Resumo:
In this paper we present a study of members of 265 nuclear families, aged six or more. This study is based of family heredograms, and takes into account the clinical form ofschistosomiasis observed before treatment with oxamniquine. The probability of occurrence of two or more cases ofhepatosplenomegaly is low, notwithstanding the fact that it was observed in 38 families. Even less frequent is the occurrence of three or more cases observed in 17 families (P=0.002). The concentration of the hepatosplenic form was higher among siblings than it was among mothers and children, or fathers and children. It was found to be not significant between husband (father) and wife (mother). These observations reinforce the evidence for the presence of a genetic component in susceptibility to the hepatosplenic form of the disease. In cases in which the mother was hepatosplenic there was a higher incidence of hepatosplenic children; the relative risk was a least five times higher than in those in which the father was the affected member (the maternal effect). In cases where both members were affected by the hepatointestinal form, the risk to the filial generation was similar to that of the population in general. Thus, in the process towards severe forms of Schistosomiasis mansoni, pre and post natal factors might be involved.
Resumo:
Dissertação para obtenção do Grau de Mestre em Biotecnologia
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia Biomédica
Resumo:
Dacron and nitrocellulose were evaluated as matrices for the dot enzyme linked immunosorbent assay (dot-ELISA) for schistosomiasis and compared to indirect immunofluorescence (IMF). Titration of sera from 18 schistosomiasis patients against soluble worm antigen preparation (SWAP) was carried out and sera from healthy individuals from non-endemic areas were used as controls. The IMF was less sensitive than the dot-ELISAs, although the difference was not statistically significant (p > 0.05). The dot-ELISA based on nitrocellulose was as sensitive as that using dacron. Stability did not differ between nitrocellulose and dacron. Specificity was lower when dacron was used than when nitrocellulose was used, although the difference was not statistically significant (p > 0.05). In conclusion, this work showed that nitrocellulose and dacron performed similarly in dot-ELISA, suggesting that they may be used alternatively in population surveillance in endemic areas.
Resumo:
RESUMO: As Análises Clínicas são um precioso elemento entre os meios complementares de diagnóstico e terapêutica permitindo uma enorme panóplia de informações sobre o estado de saúde de determinado utente. O objetivo do laboratório é fornecer informação analítica sobre as amostras biológicas, sendo esta caracterizada pela sua fiabilidade, relevância e facultada em tempo útil. Assim, tratando-se de saúde, e mediante o propósito do laboratório, é notória a sua importância, bem como, a dos fatores associados para o cumprimento do mesmo. O bom desenrolar do ciclo laboratorial, compreendido pelas fases pré-analítica, analítica e pós-analítica é crucial para que o objetivo do laboratório seja cumprido com rigor e rapidez. O presente trabalho “O Erro na Fase Pré-Analítica: Amostras Não Conformes versus Procedimentos”, enquadrado no mestrado de Qualidade e Organização no Laboratório de Análises Clínicas, pretendeu enfatizar a importância da fase pré- analítica, sendo ela apontada como a primordial em erros que acabam por atrasar a saída de resultados ou por permitir que os mesmos não sejam fidedignos como se deseja, podendo acarretar falsos diagnósticos e decisões clínicas erradas. Esta fase, iniciada no pedido médico e finalizada com a chegada das amostras biológicas ao laboratório está entregue a uma diversidade de procedimentos que acarretam, por si só, uma grande diversidade de intervenientes, para além de uma variabilidade de factores que influenciam a amostra e seus resultados. Estes fatores, que podem alterar de algum modo a “veracidade” dos resultados analíticos, devem ser identificados e tidos em consideração para que estejamos convitos que os resultados auxiliam diagnósticos precisos e uma avaliação correta do estado do utente. As colheitas que por quaisquer divergências não originam amostras que cumpram o objectivo da sua recolha, não estando por isso em conformidade com o pretendido, constituem uma importante fonte de erro para esta fase pré-analítica. Neste estudo foram consultados os dados relativos a amostras de sangue e urina não conformes detetadas no laboratório, em estudo, durante o 1º trimestre de 2012, para permitir conhecer o tipo de falhas que acontecem e a sua frequência. Aos Técnicos de Análises Clínicas, colaboradores do laboratório, foi-lhes pedido que respondessem a um questionário sobre os seus procedimentos quotidianos e constituíssem, assim, a população desta 2ª parte do projeto. Preenchido e devolvido de forma anónima, este questionário pretendeu conhecer os procedimentos na tarefa de executar colheitas e, hipoteticamente, confrontá-los com as amostras não conformes verificadas. No 1ºsemestre de 2012 e num total de 25319 utentes registaram-se 146 colheitas que necessitaram de repetição por se verificarem não conformes. A “amostra não colhida” foi a não conformidade mais frequente (50%) versus a “má identificação” que registou somente 1 acontecimento. Houve ainda não conformidades que não se registaram como “preparação inadequada” e “amostra mal acondicionada”. Os técnicos revelaram-se profissionais competentes, conhecedores das tarefas a desempenhar e preocupados em executá-las com qualidade. Eliminar o erro não estará, seguramente, ao nosso alcance porém admitir a sua presença, detetá-lo e avaliar a sua frequência fará com que possamos diminuir a sua existência e melhorar a qualidade na fase pré-analítica, atribuindo-lhe a relevância que desempenha no processo laboratorial.-----------ABSTRACT:Clinical analyses are a precious element among diagnostic and therapeutic tests as they allow an enormous variety of information on the state of health of a user. The aim of the laboratory is to supply reliable, relevant and timely analytical information on biological samples. In health-related matters, in accordance with the objective of the laboratory, their importance is vital, as is the assurance that all the tools are in place for the fulfillment of its purpose. A good laboratory cycle, which includes the pre-analytical, analytical and post-analytical phases, is crucial in fulfilling the laboratory’s mission rapidly and efficiently. The present work - "Error in the pre-analytical phase: non-compliant samples versus procedures”, as part of the Master’s in Quality and Organization in the Clinical Analyses Laboratory, wishes to emphasize the importance of the pre-analytical phase, as the phase containing most errors which eventually lead to delays in the issue of results, or the one which enables those results not to be as reliable as desired, which can lead to false diagnosis and wrong clinical decisions. This phase, which starts with the medical request and ends with the arrival of the biological samples to the laboratory, entails a variety of procedures, which require the intervention of different players, not to mention a great number of factors, which influence the sample and the results. These factors, capable of somehow altering the “truth” of the analytical results, must be identified and taken into consideration so that we may ensure that the results help to make precise diagnoses and a correct evaluation of the user’s condition. Those collections which, due to any type of differences, do not originate samples capable of fulfilling their purpose, and are therefore not compliant with the objective, constitute an important source of error in this pre-analytical phase. In the present study, we consulted data from non-compliant blood and urine samples, detected at the laboratory during the 1st quarter of 2012, to find out the type of faults that happen and their frequency. The clinical analysis technicians working at the laboratory were asked to fill out a questionnaire regarding their daily procedures, forming in this way the population for this second part of the project. Completed and returned anonymously, this questionnaire intended to investigate the procedures for collections and, hypothetically, confront them with the verified non-compliant samples. In the first semester of 2012, and out of a total of 25319 users, 146 collections had to be repeated due to non-compliance. The “uncollected sample” was the most frequent non-compliance (>50%) versus “incorrect identification” which had only one occurrence. There were also unregistered non-compliance issues such as “inadequate preparation” and “inappropriately packaged sample”. The technicians proved to be competent professionals, with knowledge of the tasks they have to perform and eager to carry them out efficiently. We will certainly not be able to eliminate error, but recognizing its presence, detecting it and evaluating its frequency will help to decrease its occurrence and improve quality in the pre-analytical phase, giving it the relevance it has within the laboratory process.
Resumo:
Dissertation submitted in partial fulfillment of the requirements for the Degree of Master of Science in Geospatial Technologies
Resumo:
Cyclospora cayetanensis causes watery diarrhea in tropical countries, among travelers and after ingestion of contaminated water and food. Very little is known about its epidemiology, pathogenic aspects and reservoirs. In Brazil, its prevalence is unknown and to date there have been reports of three outbreaks. We report here a retrospective study of 5,015 stool samples from 4,869 patients attended at Clinical Hospital of the University of São Paulo Medical School, SP, Brazil between April 1996 and January 2002, with 14 cases of Cyclospora cayetanensis being detected there was a prevalence of 0.3%. Of the 14 infected patients, the mean age was 38 years and 71.4% were female. Ten patients presented symptoms; six presented levels of immunological markers and five patients were immunodeficient.
Resumo:
Panstrongylus lutzi is generally restricted to the "caatinga" areas of north-eastern Brazil. Adult insects are frequently found in local houses, but colonies have not previously been registered in the statistics of the Control Programme of Chagas Disease. In Ceará State, our study revealed increasing occurrence of this species, usually with high infection rates for Trypanosoma cruzi, and always represented by adults that invaded the artificial environment. We also found nymphs in the peridomicile and inside the houses. In silvatic habitats we collected two adult females from hollow tree trunks, which may represent an alternative natural ecotope for the species in this state. Panstrongylus lutzi entomological collections from Sobral and Crateús, studied by morphology and morphometrics, showed great variability; those from Crateús were larger smaller and paler in colour, with individuals showing genital features consistent with those described for Panstrongylus lutzi or Panstrongylus sherlocki, whereas those from Sobral were darker and with genitalia compatible with P. sherlocki, nevertheless, all were considered to be Panstrongylus lutzi.
Resumo:
Tuberculosis is an important cause of mortality due to its high prevalence, considering that one third of the worlds population is infected with the tuberculosis bacillus. We report the first case of carcinomatous lymphangitis associated with active pulmonary tuberculosis. Carcinomatous lymphangitis is a rare event that may be confounded with tuberculosis because of its radiographic and clinical characteristics.
Resumo:
Patients with AIDS are particularly susceptible to infection with intestinal coccidia. In this study the prevalence of infections with Cryptosporidium sp and Cystoisospora belli were evaluated among HIV/AIDS patients in the Triângulo Mineiro region, Brazil. Between July 1993 and June 2003 faecal samples from 359 patients were collected and stained by a modified Ziehl-Neelsen method, resulting in 19.7% of positivity for coccidian (8.6% with Cryptosporidium sp, 10.3% with Cystoisospora belli and 0.8% with both coccidian). Patients with diarrhoea and T CD4+ lymphocyte levels < 200 cells/mm3 presented higher frequency of these protozoans, demonstrating the opportunistic profile of these infections and its relationship with the immunological status of the individual. It was not possible to determine the influence of HAART, since only 8.5% of the patients positive for coccidian received this therapy regularly. Parasitism by Cryptosporidium sp was more frequent between December and February and thus was characterised by a seasonal pattern of infection, which was not observed with Cystoisospora belli.