956 resultados para auditory cues


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The tendency to hear a tone sequence as 2 or more streams (segregated) builds up, but a sudden change in properties can reset the percept to 1 stream (integrated). This effect has not hitherto been explored using an objective measure of streaming. Stimuli comprised a 2.0-s fixed-frequency inducer followed by a 0.6-s test sequence of alternating pure tones (3 low [L]-high [H] cycles). Listeners compared intervals for which the test sequence was either isochronous or the H tones were slightly delayed. Resetting of segregation should make identifying the anisochronous interval easier. The HL frequency separation was varied (0-12 semitones), and properties of the inducer and test sequence were set to the same or different values. Inducer properties manipulated were frequency, number of onsets (several short bursts vs. one continuous tone), tone:silence ratio (short vs. extended bursts), level, and lateralization. All differences between the inducer and the L tones reduced temporal discrimination thresholds toward those for the no-inducer case, including properties shown previously not to affect segregation greatly. Overall, it is concluded that abrupt changes in a sequence cause resetting and improve subsequent temporal discrimination. (PsycINFO Database Record © 2009 APA, all rights reserved)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Onset asynchrony is an important cue for segregating sound mixtures. A harmonic of a vowel that begins before the other components contributes less to vowel quality. This asynchrony effect can be partly reversed by accompanying the leading portion of the harmonic with an octave-higher captor tone. The original interpretation was that the captor and leading portion formed a perceptual group, but it has recently been shown that the captor effect depends on neither a common onset time nor harmonic relations with the leading portion. Instead, it has been proposed that the captor effect depends on wideband inhibition in the central auditory system. Physiological evidence suggests that such inhibition occurs both within and across ears. Experiment 1 compared the efficacy of a pure-tone captor presented in the same or opposite ear to the vowel and leading harmonic. Contralateral presentation was at least as effective as ipsilateral presentation. Experiment 2 used multicomponent captors in a more comprehensive evaluation of harmonic influences on captor efficacy. Three captors with different fundamental frequencies were used, one of which formed a consecutive harmonic series with the leading harmonic. All captors were equally effective, irrespective of the harmonic relationship. These findings support and refine the inhibitory account. © 2007 Acoustical Society of America.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Previous claims that auditory stream segregation occurs in cochlear implant listeners are based on limited evidence. In experiment 1, eight listeners heard tones presented in a 30-s repeating ABA-sequence, with frequencies matching the centre frequencies of the implant's 22 electrodes. Tone A always stimulated electrode 11 (centre of the array); tone B stimulated one of the others. Tone repetition times (TRTs) from 50 to 200 ms were used. Listeners reported when they heard one or two streams. The proportion of time that each sequence was reported as segregated was consistently greater with increased electrode separation. However, TRT had no significant effect, and the perceptual reversals typical of normal-hearing listeners rarely occurred. The results may reflect channel discrimination rather than stream segregation. In experiment 2, six listeners performed a pitch-ranking task using tone pairs (reference = electrode 11). Listeners reported which tone was higher in pitch (or brighter in timbre) and their confidence in the pitch judgement. Similarities were observed in the individual pattern of results for reported segregation and pitch discrimination. Many implant listeners may show little or no sign of automatic stream segregation owing to the reduced perceptual space within which sounds can differ from one another. © 2006 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A harmonic that begins before the other harmonics contributes less than they do to vowel quality. This reduction can be partly reversed by accompanying the leading portion with a captor tone. This effect is usually interpreted as reflecting perceptual grouping of the captor with the leading portion. Instead, it has recently been proposed that the captor effect depends on broadband inhibition within the central auditory system. A test of psychophysical predictions based on this proposal showed that captor efficacy is (a) maintained for noise-band captors, (b) absent when a captor accompanies a harmonic that continues after the vowel, and (c) maintained for 80 ms or more over a gap between captor offset and vowel onset. These findings support and refine the inhibitory account. PsycINFO Database Record © 2006 APA, all rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The evidence that cochlear implant listeners routinely experience stream segregation is limited and equivocal. Streaming in these listeners was explored using tone sequences matched to the center frequencies of the implant’s 22 electrodes. Experiment 1 measured temporal discrimination for short (ABA triplet) and longer (12 AB cycles) sequences (tone/silence durations = 60/40 ms). Tone A stimulated electrode 11; tone B stimulated one of 14 electrodes. On each trial, one sequence remained isochronous, and tone B was delayed in the other; listeners had to identify the anisochronous interval. The delay was introduced in the second half of the longer sequences. Prior build-up of streaming should cause thresholds to rise more steeply with increasing electrode separation, but no interaction with sequence length was found. Experiment 2 required listeners to identify which of two target sequences was present when interleaved with distractors (tone/silence durations = 120/80 ms). Accuracy was high for isolated targets, but most listeners performed near chance when loudness-matched distractors were added, even when remote from the target. Only a substantial reduction in distractor level improved performance, and this effect did not interact with target-distractor separation. These results indicate that implantees often do not achieve stream segregation, even in relatively unchallenging tasks.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Over recent years much has been learned about the way in which depth cues are combined (e.g. Landy et al., 1995). The majority of this work has used subjective measures, a rating scale or a point of subjective equality, to deduce the relative contributions of different cues to perception. We have adopted a very different approach by using two interval forced-choice (2IFC) performance measures and a signal processing framework. We performed summation experiments for depth cue increment thresholds between pairs of pictorial depth cues in displays depicting slanted planar surfaces made from arrays of circular 'contrast' elements. Summation was found to be ideal when size-gradient was paired with contrast-gradient for a wide range of depth-gradient magnitudes in the null stimulus. For a pairing of size-gradient and linear perspective, substantial summation (> 1.5 dB) was found only when the null stimulus had intermediate depth gradients; when flat or steeply inclined surfaces were depicted, summation was diminished or abolished. Summation was also abolished when one of the target cues was (i) not a depth cue, or (ii) added in conflict. We conclude that vision has a depth mechanism for the constructive combination of pictorial depth cues and suggest two generic models of summation to describe the results. Using similar psychophysical methods, Bradshaw and Rogers (1996) revealed a mechanism for the depth cues of motion parallax and binocular disparity. Whether this is the same or a different mechanism from the one reported here awaits elaboration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The factors influencing the stream segregation of discrete tones and the perceived continuity of discrete tones as continuing through an interrupting masker are well understood as separate phenomena. Two experiments tested whether perceived continuity can influence the build-up of stream segregation by manipulating the perception of continuity during an induction sequence and measuring streaming in a subsequent test sequence comprising three triplets of low and high frequency tones (LHL-…). For experiment 1, a 1.2-s standard induction sequence comprising six 100-ms L-tones strongly promoted segregation, whereas a single extended L-inducer (1.1 s plus 100-ms silence) did not. Segregation was similar to that following the single extended inducer when perceived continuity was evoked by inserting noise bursts between the individual tones. Reported segregation increased when the noise level was reduced such that perceived continuity no longer occurred. Experiment 2 presented a 1.3-s continuous inducer created by bridging the 100-ms silence between an extended L-inducer and the first test-sequence tone. This configuration strongly promoted segregation. Segregation was also increased by filling the silence after the extended inducer with noise, such that it was perceived like a bridging inducer. Like physical continuity, perceived continuity can promote or reduce test-sequence streaming, depending on stimulus context.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The tendency to hear a sequence of alternating low (L) and high (H) frequency tones as two streams can be increased by a preceding induction sequence, even one composed only of same-frequency tones. Four experiments used such an induction sequence (10 identical L tones) to promote segregation in a shorter test sequence comprising L and H tones. Previous studies have shown that the build-up of stream segregation is usually reduced greatly when a sudden change in acoustic properties distinguishes all of the induction tones from their test-sequence counterparts. Experiment 1 showed that a single deviant tone, created by altering the final inducer (in frequency, level, duration, or replacement with silence) reduced reported segregation, often substantially. Experiment 2 partially replicated this finding, using changes in temporal discrimination as a measure of streaming. Experiments 3 and 4 varied the size of a frequency change applied to the deviant tone; the extent of resetting varied with size only gradually. The results suggest that resetting begins to occur once the change is large enough to be noticeable. Since the prior inducers always remained unaltered in the deviant-tone conditions, it is proposed that a single change actively resets the build-up evoked by the induction sequence.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The possibility that developmental dyslexia results from low-level sensory processing deficits has received renewed interest in recent years. Opponents of such sensory-based explanations argue that dyslexia arises primarily from phonological impairments. However, many behavioural correlates of dyslexia cannot be explained sufficiently by cognitive-level accounts and there is anatomical, psychometric and physiological evidence of sensory deficits in the dyslexic population. This thesis aims to determine whether the low-level (pre-attentive) processing of simple auditory stimuli is disrupted in compensated adult dyslexics. Using psychometric and neurophysiological measures, the nature of auditory processing abnormalities is investigated. Group comparisons are supported by analysis of individual data in order to address the issue of heterogeneity in dyslexia. The participant pool consisted of seven compensated dyslexic adults and seven age and IQ matched controls. The dyslexic group were impaired, relative to the control group, on measures of literacy, phonological awareness, working memory and processing speed. Magnetoencephalographic recordings were conducted during processing of simple, non-speech, auditory stimuli. Results confirm that low-level auditory processing deficits are present in compensated dyslexic adults. The amplitude of N1m responses to tone pair stimuli were reduced in the dyslexic group. However, there was no evidence that manipulating either the silent interval or the frequency separation between the tones had a greater detrimental effect on dyslexic participants specifically. Abnormal MMNm responses were recorded in response to frequency deviant stimuli in the dyslexic group. In addition, complete stimulus omissions, which evoked MMNm responses in all control participants, failed to elicit significant MMNm responses in all but one of the dyslexic individuals. The data indicate both a deficit of frequency resolution at a local level of auditory processing and a higher-level deficit relating to the grouping of auditory stimuli, relevant for auditory scene analysis. Implications and directions for future research are outlined.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The two elcctrophysiological tests currently favoured in the clinical measurement of hearing threshold arc the brainstorm evoked potential (BAEP) and the slow vertex response (SVR). However, both tests possess disadvantages. The BAEP is the test of choice in younger patients as it is stable at all levels of arousal, but little information has been obtained to date at a range of frequencies. The SVR is frequency specific but is unreliable in certain adult subjects and is unstable during sleep or in young children. These deficiencies have prompted research into a third group of potentials, the middle latency response (MLR) and the 40HZ responses. This research has compared the SVR and 40HZ response in waking adults and reports that the 40HZ test can provide a viable alternative to the SVR provided that a high degree of subject relaxation is ensured. A second study examined the morphology of the MLR and 40HZ during sleep. This work suggested that these potentials arc markedly different during sleep and that methodological factors have been responsible for masking these changes in previous studies. The clinical possibilities of tone pip BAEPs were then examined as these components were proved to be the only stable responses present in sleep. It was found that threshold estimates to 5OOHz, lOOOHz and 4000Hz stimuli could be made to within 15dBSL in most cases. A final study looked more closely at methods of obtaining frequency specific information in sleeping subjects. Threshold estimates were made using established BAEP parameters and this was compared to a 40HZ procedure which recorded a series of BAEPs over a 100msec. time sweep. Results indicated that the 40mHz procedure was superior to existing techniques in estimating threshold to low frequency stimuli. This research has confirmed a role for the MLR and 40Hz response as alternative measures of hearing capability in waking subjects and proposes that the 40Hz technique is useful in measuring frequency specific thresholds although the responses recorded derive primarily from the brainstem.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Difficulties in visual attention are increasingly being linked to dyslexia. To date, the majority of studies have inferred functionality of attention from response times to stimuli presented for an indefinite duration. However, in paradigms that use reaction times to investigate the ability to orient attention, a delayed reaction time could also indicate difficulties in signal enhancement or noise exclusion once oriented. Thus, in order to investigate attention modulation and visual crowding effects in dyslexia, this study measured stimulus discrimination accuracy to rapidly presented displays. Adults with dyslexia (AwD) and controls discriminated the orientation of a target in an array of different numbers of - and differently spaced - vertically orientated distractors. Results showed that AwD: were disproportionately impacted by (i) close spacing and (ii) increased numbers of stimuli, (iii) did use pre-cues to modulate attention, but (iv) used cues less successfully to counter effects of increasing numbers of distractors. A greater dependence on pre-cues, larger effects of crowding and the impact of increased numbers of distractors all correlated significantly with measures of literacy. These findings extend previous studies of visual crowding of letters in dyslexia to non-complex stimuli. Overall, AwD do not use cues less, but they do use cues less successfully. We conclude that visual attention is an important factor to consider in the aetiology of dyslexia. The results challenge existing theoretical accounts of visual attention deficits, which alone are unable to comprehensively explain the pattern of findings demonstrated here.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thirteen experiments investigated the dynamics of stream segregation. Experiments 1-6b used a similar method, where a same-frequency induction sequence (usually 10 repetitions of an identical pure tone) promoted segregation in a subsequent, briefer test sequence (of alternating low- and high-frequency tones). Experiments 1-2 measured streaming using a direct report of perception and a temporal-discrimination task, respectively. Creating a single deviant by altering the final inducer (e.g. in level or replacement with silence) reduced segregation, often substantially. As the prior inducers remained unaltered, it is proposed that the single change actively reset build-up. The extent of resetting varied gradually with the size of a frequency change, once noticeable (experiments 3a-3b). By manipulating the serial position of a change, experiments 4a-4b demonstrated that resetting only occurred when the final inducer was replaced with silence, as build-up is very rapid during a same-frequency induction sequence. Therefore, the observed resetting cannot be explained by fewer inducers being presented. Experiment 5 showed that resetting caused by a single deviant did not increase when prior inducers were made unpredictable in frequency (four-semitone range). Experiments 6a-6b demonstrated that actual and perceived continuity have a similar effect on subsequent streaming judgements promoting either integration or segregation, depending on listening context. Experiment 7 found that same-frequency inducers were considerably more effective at promoting segregation than an alternating-frequency inducer, and that a trend for deviant-tone resetting was only apparent for the same-frequency case. Using temporal-order judgments, experiments 8-9 demonstrated the stream segregation of pure-tone-like percepts, evoked by sudden changes in amplitude or interaural time difference for individual components of a complex tone, Active resetting was observed when a deviant was inserted into a sequence of these percepts (Experiment 10). Overall, these experiments offer new insight into the segregation-promotIng effect of induction sequences, and the factors which can reset this effect.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Research into mental-health risks has tended to focus on epidemiological approaches and to consider pieces of evidence in isolation. Less is known about the particular factors and their patterns of occurrence that influence clinicians’ risk judgements in practice. Aims: To identify the cues used by clinicians to make risk judgements and to explore how these combine within clinicians’ psychological representations of suicide, self-harm, self-neglect, and harm to others. Method: Content analysis was applied to semi-structured interviews conducted with 46 practitioners from various mental-health disciplines, using mind maps to represent the hierarchical relationships of data and concepts. Results: Strong consensus between experts meant their knowledge could be integrated into a single hierarchical structure for each risk. This revealed contrasting emphases between data and concepts underpinning risks, including: reflection and forethought for suicide; motivation for self-harm; situation and context for harm to others; and current presentation for self-neglect. Conclusions: Analysis of experts’ risk-assessment knowledge identified influential cues and their relationships to risks. It can inform development of valid risk-screening decision support systems that combine actuarial evidence with clinical expertise.