913 resultados para Weighted graph matching


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A common time scale for the EPICA ice cores from Dome C (EDC) and Dronning Maud Land (EDML) has been established. Since the EDML core was not drilled on a dome, the development of the EDML1 time scale for the EPICA ice core drilled in Dronning Maud Land was based on the creation of a detailed stratigraphic link between EDML and EDC, which was dated by a simpler 1D ice-flow model. The synchronisation between the two EPICA ice cores was done through the identification of several common volcanic signatures. This paper describes the rigorous method, using the signature of volcanic sulfate, which was employed for the last 52 kyr of the record. We estimated the discrepancies between the modelled EDC and EDML glaciological age scales during the studied period, by evaluating the ratio R of the apparent duration of temporal intervals between pairs of isochrones. On average R ranges between 0.8 and 1.2 corresponding to an uncertainty of up to 20% in the estimate of the time duration in at least one of the two ice cores. Significant deviations of R up to 1.4–1.5 are observed between 18 and 28 kyr before present (BP), where present is defined as 1950. At this stage our approach does not allow us unequivocally to find out which of the models is affected by errors, but assuming that the thinning function at both sites and accumulation history at Dome C (which was drilled on a dome) are correct, this anomaly can be ascribed to a complex spatial accumulation variability (which may be different in the past compared to the present day) upstream of the EDML core.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: It has been shown that different implant designs and different vertical implant positions have an influence on crestal bone levels. The aim of the present study was to evaluate radiographic crestal bone changes around experimental dental implants with non-matching implant-abutment diameters placed submucosally or transmucosally at three different levels relative to the alveolar crest. METHODS: Sixty two-piece dental implants with non-matching implant-abutment diameters were placed in edentulous spaces bilaterally in five foxhounds. The implants were placed submucosally or transmucosally in the left or the right side of the mandible. Within each side, six implants were randomly placed at three distinct levels relative to the alveolar crest. After 12 weeks, 60 crowns were cemented. Radiographs were obtained from all implant sites following implant placement, after crown insertion, and monthly for 6 months after loading. RESULTS: Radiographic analysis revealed very little bone loss and a slight increase in bone level for implants placed at the level of the crest or 1 mm above. The greatest bone loss occurred at implants placed 1 mm below the bone crest. No clinically significant differences regarding marginal bone loss and the level of the bone-to-implant contact were detected between implants with a submucosal or a transmucosal healing. CONCLUSIONS: Implants with non-matching implant-abutment diameters demonstrated some bone loss; however, it was a small amount. There was no clinically significant difference between submucosal and transmucosal approaches.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report a case of a 34-year-old woman who had a left anterior wall myocardial infarction develop in the first trimester of pregnancy. Despite urgent and successful revascularization, she demonstrated persistent segmental wall motion abnormalities by transthoracic echocardiography. To manage this patient safely through pregnancy with a better definition of myocardium at risk, a cardiac magnetic resonance examination was performed. This identified a large territory of acutely edematous myocardium in addition to providing accurate volumetric measurements of left ventricular size and function. Because of her gravid state, gadolinium was not administered nor was it required to delineate the region of myocardium at risk.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Chapter 1 introduces the tools and mechanics necessary for this report. Basic definitions and topics of graph theory which pertain to the report and discussion of automorphic decompositions will be covered in brief detail. An automorphic decomposition D of a graph H by a graph G is a G-decomposition of H such that the intersection of graph (D) @H. H is called the automorhpic host, and G is the automorphic divisor. We seek to find classes of graphs that are automorphic divisors, specifically ones generated cyclically. Chapter 2 discusses the previous work done mainly by Beeler. It also discusses and gives in more detail examples of automorphic decompositions of graphs. Chapter 2 also discusses labelings and their direct relation to cyclic automorphic decompositions. We show basic classes of graphs, such as cycles, that are known to have certain labelings, and show that they also are automorphic divisors. In Chapter 3, we are concerned with 2-regular graphs, in particular rCm, r copies of the m-cycle. We seek to show that rCm has a ρ-labeling, and thus is an automorphic divisor for all r and m. we discuss methods including Skolem type difference sets to create cycle systems and their correlation to automorphic decompositions. In the Appendix, we give classes of graphs known to be graceful and our java code to generate ρ-labelings on rCm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Computer-aided surgery (CAS) allows for real-time intraoperative feedback resulting in increased accuracy, while reducing intraoperative radiation. CAS is especially useful for the treatment of certain pelvic ring fractures, which necessitate the precise placement of screws. Flouroscopy-based CAS modules have been developed for many orthopedic applications. The integration of the isocentric flouroscope even enables navigation using intraoperatively acquired three-dimensional (3D) data, though the scan volume and imaging quality are limited. Complicated and comprehensive pathologies in regions like the pelvis can necessitate a CT-based navigation system because of its larger field of view. To be accurate, the patient's anatomy must be registered and matched with the virtual object (CT data). The actual precision within the region of interest depends on the area of the bone where surface matching is performed. Conventional surface matching with a solid pointer requires extensive soft tissue dissection. This contradicts the primary purpose of CAS as a minimally invasive alternative to conventional surgical techniques. We therefore integrated an a-mode ultrasound pointer into the process of surface matching for pelvic surgery and compared it to the conventional method. Accuracy measurements were made in two pelvic models: a foam model submerged in water and one with attached porcine muscle tissue. Three different tissue depths were selected based on CT scans of 30 human pelves. The ultrasound pointer allowed for registration of virtually any point on the pelvis. This method of surface matching could be successfully integrated into CAS of the pelvis.