998 resultados para Viscoelastic Bi-Materials


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of the thesis was to define the quality potential of DIP and hardwood CTMP based raw material furnish for a printing paper production and to define the end product's pulp-based boundary conditions especially when thinking of Chinese markets. Although the Chinese paper industry expands rapidly, the production of some paper grades is still exiguous. Especially the softwood resources are limited in Asia, thus the purpose of the thesis was to find out the possibilities to produce printing paper in China from local raw materials. Bleached CTMP can be produced, for example, from fast-growing hardwood species like eucalyptus and poplar. Therefore in this thesis it was examined if good quality printing paper is possible to produce by using deinked pulp and hardwood CTMP based furnish. In the first section of experimental part, various deinked pulps and chemithermomechanical pulps were compared. The deinked pulps were from China, Central Europe and Finland. Central European was made for magazine papers, and the Chinese as well as the Finnish pulps were made for newsprints. Two of the BCTMPs were from China and those both were made from poplar, whereas one BCTMP was made from eucalyptus in a pilot plant. There were significant differences especially between BCTMPs and their paper properties. In the second section of experimental part, the deinked pulp and eucalyptus BCTMP were blended to produce handsheets. The results show that producing the highest quality printing paper would be difficult from these raw materials. Deinked pulp affected especially the strength and optical properties as well as calender blackening. The BCTMP was found to have effects mostly on the smoothness, strength and optical properties as well as calender blackening.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Corrosion reduces the lifetime of municipal solid waste incineration (MSWI) superheater tubes more than any other cause. It can be minimized by the careful selection of those materials that are most resistant to corrosion under operating conditions. Since thousands of different materials are already known and many more are developed every year, here the selection methodology developed by Prof. Ashby of the University of Cambridge was used to evaluate the performance of different materials to be used as MSWI superheater tubes. The proposed materials can operate at steam pressures and temperatures over 40 bars and 400ºC, respectively. Two case studies are presented: one makes a balanced selection between mechanical properties and cost per thermal unit; and the other focuses on increasing tube lifetime. The balanced selection showed that AISI 410 martensitic stainless steel (wrought, hard tempered) is the best candidate with a good combination of corrosion resistance, a relatively low price (0.83-0.92 e/kg) and a good thermal conductivity (23-27 W/m K). Meanwhile, Nitronic 50/XM-19 stainless steel is the most promising candidate for longterm selection, as it presents high corrosion resistance with a relatively low price (4.86-5.14 e/kg) compared to Ni-alloys.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: O objetivo geral do estudo é avaliar a acurácia da ultrassonografia (BI-RADS) no diagnóstico do câncer de mama, e os objetivos específicos, descrever a frequência de apresentação dos diferentes achados ultrassonográficos e a avaliação da concordância entre observadores. MATERIAIS E MÉTODOS: Exames de 110 pacientes encaminhados para biópsia, com diagnóstico prévio de nódulos, foram reanalisados independentemente por dois médicos especialistas utilizando a nomenclatura do BI-RADS. Os achados histológicos foram utilizados como padrão-ouro. A acurácia dos achados foi determinada. As diferenças nos grupos de comparação foram analisadas com teste qui-quadrado para variáveis categóricas e a concordância entre os médicos foi calculada por meio da estatística kappa (κ). RESULTADOS: Cento e dez massas mamárias foram avaliadas pelo ultrassom, sendo que 76 (69%) foram benignas e 34 (30,9%), malignas. Foram observados, entre os radiologistas, sensibilidade variando entre 70,5% e 82,3%, valor preditivo negativo entre 81,1% e 87,5%, valor preditivo positivo entre 42,1% e 45,1%, especificidade entre 56,58% e 55,2% e acurácia entre 60,9% e 63,6%. Na avaliação entre observadores foi obtida concordância global considerada moderada (κ= 0,50). CONCLUSÃO: O BI-RADS 4ª edição é um acurado sistema para auxiliar os médicos na descrição das lesões mamárias e na tomada de condutas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: A proposta deste estudo foi avaliar a acurácia da classificação BI-RADS® na mamografia. Os pontos secundários foram descrever a frequência de apresentação dos diferentes achados mamográficos e avaliar a concordância entre observadores. MATERIAIS E MÉTODOS: Os exames de 115 pacientes, encaminhados para core biopsy, foram reavaliados independentemente por dois médicos especialistas, cegados, utilizando a recomendação do BI-RADS. Posteriormente, os exames foram comparados com a histologia. A acurácia da classificação BI-RADS na mamografia foi avaliada. A concordância entre os médicos foi calculada pela estatística kappa (κ) de Cohen e as diferenças nos grupos de comparação foram analisadas com teste qui-quadrado. RESULTADOS: Esta pesquisa demonstrou que a acurácia mamográfica oscilou de 75% a 62% na diferenciação entre lesões benignas de malignas com o uso do BI-RADS. Houve importante concordância na descrição das margens dos nódulos (κ= 0,66). Baixa concordância foi identificada na descrição dos contornos (formas) dos nódulos (κ= 0,40) e na descrição das calcificações, tanto em relação à sua distribuição (κ= 0,24) como também em relação à morfologia (κ= 0,36). CONCLUSÃO: O presente estudo demonstrou que o método é acurado na diferenciação de lesões benignas de malignas. A concordância foi fraca na análise das calcificações quanto a morfologia e distribuição, no entanto, identificou-se elevação progressiva dos valores preditivos positivos nas subcategorias 4.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: O objetivo deste trabalho foi avaliar o BI-RADS® como fator preditivo de suspeição de malignidade em lesões mamárias não palpáveis nas categorias 3, 4 e 5, correlacionando as mamografias com os resultados histopatológicos através do cálculo do valor preditivo positivo do exame mamográfico. MATERIAIS E MÉTODOS: Trezentas e setenta e uma pacientes encaminhadas a um serviço de referência em tratamento de câncer em Teresina, PI, para realização de exames histopatológicos em mama no período de julho de 2005 a março de 2008, por terem mamografia de categorias 3, 4 ou 5, tiveram seus exames revisados. Das 371 pacientes, 265 foram submetidas a biópsia por agulha grossa e 106, a marcação pré-cirúrgica. RESULTADOS: Em relação às mamografias, 11,32% foram classificadas como categoria 3, 76,28% como categoria 4 e 12,4% como categoria 5. Os resultados histológicos demonstraram 24% de exames positivos para malignidade. Os valores preditivos positivos das categorias 3, 4 e 5 foram, respectivamente, de 7,14%, 16,96% e 82,61%. Foram calculados os valores preditivos positivos, separadamente, para as biópsias percutâneas (7,14%, 15,76%, 76,47%) e para as marcações pré-cirúrgicas (7,14%, 20%, 100%). CONCLUSÃO: Achados malignos foram subestimados pelo laudo radiológico e houve superestimação de achados benignos, o que resultou na realização desnecessária de alguns procedimentos invasivos.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rapid manufacturing is an advanced manufacturing technology based on layer-by-layer manufacturing to produce a part. This paper presents experimental work carried out to investigate the effects of scan speed, layer thickness, and building direction on the following part features: dimensional error, surface roughness, and mechanical properties for DMLS with DS H20 powder and SLM with CL 20 powder (1.4404/AISI 316L). Findings were evaluated using ANOVA analysis. According to the experimental results, build direction has a significant effect on part quality, in terms of dimensional error and surface roughness. For the SLM process, the build direction has no influence on mechanical properties. Results of this research support industry estimating part quality and mechanical properties before the production of parts with additive manufacturing, using iron-based powders

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: Avaliar o desempenho de parâmetros morfométricos, calculados a partir do contorno de lesões de mama em ultrassonografias, na quantificação de suas características morfológicas e na distinção das categorias 2, 3, 4 e 5 do sistema de classificação ecográfica BI-RADS. MATERIAIS E MÉTODOS: A casuística é composta por 40 casos com registro ortogonal de pacientes submetidas à cirurgia. A partir das lesões segmentadas, foram calculados cinco parâmetros morfométricos para quantificar o contorno e a forma das lesões: razão de área, razão de superposição, valor residual normalizado, circularidade e razão entre largura e profundidade. A análise discriminante linear foi usada para selecionar os parâmetros mais significativos na distinção das características morfológicas das lesões, usando como figura de mérito a curva ROC. RESULTADOS: A razão de superposição foi capaz de diferenciar estatisticamente as lesões classificadas como BI-RADS 3 daquelas classificadas como BI-RADS 4 (a = 5%; p = 0,015), sendo, também, o parâmetro morfométrico que apresentou melhor desempenho na diferenciação entre lesões malignas e benignas. CONCLUSÃO: Este resultado indica que a análise morfométrica de lesões de mama em ultrassonografias tem potencial para auxiliar na distinção de pacientes que deveriam ser submetidas à biópsia, daquelas que poderiam manter controle por métodos de imagem.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Amb el present treball es vol aprofundir en la manera que influeix l’organització d’espais, d’ambients i les característiques dels materials en el procés educatiu. A partir d’una recerca teòrica en base les necessitats educatives de la societat actual, les necessitats evolutives dels infants, i en base a l’observació i anàlisi d’escoles reggianes i catalanes referents que tenen en compte com a agent educador l’espai, els ambients i els materials, es volen reunir quines són les característiques bàsiques de l’organització dels espais, ambients i materials per garantir una educació de qualitat a l’etapa infantil (3-6).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective To evaluate the performance of diagnostic centers in the classification of mammography reports from an opportunistic screening undertaken by the Brazilian public health system (SUS) in the municipality of Goiânia, GO, Brazil in 2010. Materials and Methods The present ecological study analyzed data reported to the Sistema de Informação do Controle do Câncer de Mama (SISMAMA) (Breast Cancer Management Information System) by diagnostic centers involved in the mammographic screening developed by the SUS. Based on the frequency of mammograms per BI-RADS® category and on the limits established for the present study, the authors have calculated the rate of conformity for each diagnostic center. Diagnostic centers with equal rates of conformity were considered as having equal performance. Results Fifteen diagnostic centers performed mammographic studies for SUS and reported 31,198 screening mammograms. The performance of the diagnostic centers concerning BI-RADS classification has demonstrated that none of them was in conformity for all categories, one center presented conformity in five categories, two centers, in four categories, three centers, in three categories, two centers, in two categories, four centers, in one category, and three centers with no conformity. Conclusion The results of the present study demonstrate unevenness in the diagnostic centers performance in the classification of mammograms reported to SISMAMA from the opportunistic screening undertaken by SUS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective Undertaking of a complete audit of the service of mammography, as recommended by BI-RADS®, in a private reference institution for breast cancer diagnosis in the city of São Paulo, SP, Brazil, and comparison of results with those recommended by the literature. Materials and Methods Retrospective, analytical and cross-sectional study including 8,000 patients submitted to mammography in the period between April 2010 and March 2011, whose results were subjected to an internal audit. The patients were followed-up until December 2012. Results The radiological classification of 7,249 screening mammograms, according to BI-RADS, was the following: category 0 (1.43%), 1 (7.82%), 2 (80.76%), 3 (8.35%), 4 (1.46%), 5 (0.15%) and 6 (0.03%). The breast cancer detection ratio was 4.8 cases per 1,000 mammograms. Ductal carcinoma in situ was found in 22.8% of cases. Positive predictive values for categories 3, 4 and 5 were 1.3%, 41.3% and 100%, respectively. In the present study, the sensitivity of the method was 97.1% and specificity, 97.4%. Conclusion The complete internal audit of a service of mammography is essential to evaluate the quality of such service, which reflects on an early breast cancer detection and reduction of mortality rates.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objetivo: Determinar taxas de definição diagnóstica e complicações da biópsia percutânea guiada por tomografia computadorizada (TC) de lesões ósseas suspeitas de malignidade. Materiais e Métodos: Estudo retrospectivo que incluiu 186 casos de biópsia percutânea guiada por TC de lesões ósseas no período de janeiro de 2010 a dezembro de 2012. Todas as amostras foram obtidas usando agulhas de 8 a 10 gauge. Foram coletados dados demográficos, história de neoplasia maligna prévia, dados relacionados à lesão, ao procedimento e ao resultado histológico. Resultados: A maioria dos pacientes era do sexo feminino (57%) e a idade média foi 53,0 ± 16,4 anos. Em 139 casos (74,6%) a suspeita diagnóstica era metástase e os tumores primários mais comuns foram de mama (32,1%) e próstata (11,8%). Os ossos mais envolvidos foram coluna vertebral (36,0%), bacia (32,8%) e ossos longos (18,3%). Houve complicações em apenas três pacientes (1,6%), incluindo uma fratura, um caso de parestesia com comprometimento funcional e uma quebra da agulha necessitando remoção cirúrgica. Amostras de 183 lesões (98,4%) foram consideradas adequadas para diagnóstico. Resultados malignos foram mais frequentes nos pacientes com suspeita de lesão secundária e história de neoplasia maligna conhecida (p < 0,001) e nos procedimentos orientados pela PET/CT (p = 0,011). Conclusão: A biópsia percutânea guiada por TC é segura e eficaz no diagnóstico de lesões ósseas suspeitas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Biópsia percutânea guiada por tomografia computadorizada é uma alternativa segura e eficaz para avaliação de lesões intraorbitárias selecionadas, em que o diagnóstico pré-operatório é importante para o planejamento terapêutico. Descrevemos dois casos de pacientes com tumores orbitários incomuns em que o diagnóstico foi obtido por biópsia com agulha grossa guiada por tomografia computadorizada, dando ênfase para os aspectos técnicos do procedimento.