938 resultados para ULTRASOUND-GUIDED BIOPSY


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ultrasound image reconstruction from the echoes received by an ultrasound probe after the transmission of diverging waves is an active area of research because of its capacity to insonify at ultra-high frame rate with large regions of interest using small phased arrays as the ones used in echocardiography. Current state-of-the-art techniques are based on the emission of diverging waves and the use of delay and sum strategies applied on the received signals to reconstruct the desired image (DW/DAS). Recently, we have introduced the concept of Ultrasound Fourier Slice Imaging (UFSI) theory for the reconstruction of ultrafast imaging for linear acquisition. In this study, we extend this theory to sectorial acquisition thanks to the introduction of an explicit and invertible spatial transform. Starting from a diverging wave, we show that the direct use of UFSI theory along with the application of the proposed spatial transform allows reconstructing the insonified medium in the conventional Cartesian space. Simulations and experiments reveal the capacity of this new approach in obtaining competitive quality of ultrafast imaging when compared with the current reference method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To sustain a lifelong ability to initiate organs, plants retain pools of undifferentiated cells with a preserved proliferation capacity. The root pericycle represents a unique tissue with conditional meristematic activity, and its tight control determines initiation of lateral organs. Here we show that the meristematic activity of the pericycle is constrained by the interaction with the adjacent endodermis. Release of these restraints by elimination of endodermal cells by single-cell ablation triggers the pericycle to re-enter the cell cycle. We found that endodermis removal substitutes for the phytohormone auxin-dependent initiation of the pericycle meristematic activity. However, auxin is indispensable to steer the cell division plane orientation of new organ-defining divisions. We propose a dual, spatiotemporally distinct role for auxin during lateral root initiation. In the endodermis, auxin releases constraints arising from cell-to-cell interactions that compromise the pericycle meristematic activity, whereas, in the pericycle, auxin defines the orientation of the cell division plane to initiate lateral roots.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Study design: A retrospective study of image guided cervical implant placement precision. Objective: To describe a simple and precise classification of cervical critical screw placement. Summary of Background Data: "Critical" screw placement is defined as implant insertion into a bone corridor which is surrounded circumferentially by neurovascular structures. While the use of image guidance has improved accuracy, there is currently no classification which provides sufficient precision to assess the navigation success of critical cervical screw placement. Methods: Based on postoperative clinical evaluation and CT imaging, the orthogonal view evaluation method (OVEM) is used to classify screw accuracy into grade I (no cortical breach), grade la (screw thread cortical breach), grade II (internal diameter cortical breach) and grade III (major cortical breach causing neural or vascular injury). Grades II and III are considered to be navigation failures, after accounting for bone corridor / screw mismatch (minimal diameter of targeted bone corridor being smaller than an outer screw diameter). Results: A total of 276 screws from 91 patients were classified into grade I (64.9%), grade la (18.1%), and grade II (17.0%). No grade III screw was observed. The overall rate of navigation failure was 13%. Multiple logistic regression indicated that navigational failure was significantly associated with the level of instrumentation and the navigation system used. Navigational failure was rare (1.6%) when the margin around the screw in the bone corridor was larger than 1.5 mm. Conclusions: OVEM evaluation appears to be a useful tool to assess the precision of critical screw placement in the cervical spine. The OVEM validity and reliability need to be addressed. Further correlation with clinical outcomes will be addressed in future studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AbstractObjective:To report the results of computed tomography (CT)-guided percutaneous resection of the nidus in 18 cases of osteoid osteoma.Materials and Methods:The medical records of 18 cases of osteoid osteoma in children, adolescents and young adults, who underwent CT-guided removal of the nidus between November, 2004 and March, 2009 were reviewed retrospectively for demographic data, lesion site, clinical outcome and complications after procedure.Results:Clinical follow-up was available for all cases at a median of 29 months (range 6–60 months). No persistence of pre-procedural pain was noted on 17 patients. Only one patient experienced recurrence of symptoms 12 months after percutaneous resection, and was successfully retreated by the same technique, resulting in a secondary success rate of 18/18 (100%).Conclusion:CT-guided removal or destruction of the nidus is a safe and effective alternative to surgical resection of the osteoid osteoma nidus.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AbstractObjective:To compare the accuracy of computer-aided ultrasound (US) and magnetic resonance imaging (MRI) by means of hepatorenal gradient analysis in the evaluation of nonalcoholic fatty liver disease (NAFLD) in adolescents.Materials and Methods:This prospective, cross-sectional study evaluated 50 adolescents (aged 11–17 years), including 24 obese and 26 eutrophic individuals. All adolescents underwent computer-aided US, MRI, laboratory tests, and anthropometric evaluation. Sensitivity, specificity, positive and negative predictive values and accuracy were evaluated for both imaging methods, with subsequent generation of the receiver operating characteristic (ROC) curve and calculation of the area under the ROC curve to determine the most appropriate cutoff point for the hepatorenal gradient in order to predict the degree of steatosis, utilizing MRI results as the gold-standard.Results:The obese group included 29.2% girls and 70.8% boys, and the eutrophic group, 69.2% girls and 30.8% boys. The prevalence of NAFLD corresponded to 19.2% for the eutrophic group and 83% for the obese group. The ROC curve generated for the hepatorenal gradient with a cutoff point of 13 presented 100% sensitivity and 100% specificity. As the same cutoff point was considered for the eutrophic group, false-positive results were observed in 9.5% of cases (90.5% specificity) and false-negative results in 0% (100% sensitivity).Conclusion:Computer-aided US with hepatorenal gradient calculation is a simple and noninvasive technique for semiquantitative evaluation of hepatic echogenicity and could be useful in the follow-up of adolescents with NAFLD, population screening for this disease as well as for clinical studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

L'adoption de l'IRM dans le parcours diagnostique a déterminé la transition des biopsies aléatoires aux biopsies ciblées vers les lésions visibles à l'imagerie. L'utilisation de logiciels rendant possible la fusion d'images IRM et échographiques permet d'améliorer significativement la précision diagnostique de ces biopsies. De plus, pour déterminer l'éligibilité d'un patient à une thérapie focale, davantage de précision diagnostique est requise au niveau de toute la glande ; par conséquent, des biopsies avec une densité d'échantillonnage plus élevée par voie transpérinéale peuvent être proposées.Les nouvelles techniques de biopsie de la prostate permettent une prise en charge personnalisée grâce à une meilleure caractérisation de l'agressivité et de l'extension locale du cancer de la prostate. The adoption of multiparametric MRI within the diagnostic pathway has allowed urologists to move from random biopsy to targeted biopsy directed towards MR-visible lesions. The use of software for MR to TRUS fusion may enhance the diagnostic accuracy of targeted biopsy. To determine the eligibility for tissue-preserving approaches, further precision is required, and template prostate mapping biopsy may be offered. The employment of novel biopsy techniques provide better characterisation of the disease, and allows a tailored approach to a single subject.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AbstractThe authors review the main concepts regarding the importance of cleaning/disinfection of ultrasonography probes, aiming a better comprehension by practitioners and thus enabling strategies to establish a safe practice without compromising the quality of the examination and the operator productivity. In the context of biosafety, it is imperative to assume that contact with blood or body fluids represents a potential source of infection. Thus, in order to implement cleaning/disinfection practice, it is necessary to understand the principles of infection control, to consider the cost/benefit ratio of the measures to be implemented, and most importantly, to comprehend that such measures will not only benefit the health professional and the patient, but the society as a whole.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Screening mammography is the only imaging modality with proved decrease in breast cancer mortality. Ultrasound has been proposed as additional tool for screening. Controversies remain about the real value of sonography in this setting. In Caucasian women with dense breast, sonography improves significantly breast cancer detection, but also increases the false positive cases, biopsies and costs. A careful selection of women who may benefit from additional screening with sonography is mandatory.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract Objective: To estimate the prevalence and evaluate sonographic findings compatible with changes consistent with hepatic steatosis in patients referred for abdominal ultrasonography at four reference centers in Aracaju, SE, Brazil. Materials and Methods: Prospective, descriptive survey, with analytical and quantitative approach, comprising abdominal ultrasonography scans performed with a convex, dynamic 3.75 MHz transducer. Liver dimensions and parenchymal echotexture were evaluated, classifying hepatic steatosis into grades (1, 2 or 3). The SPSS® 22.0 software was used for statistical analysis, adopting p < 0.05 as significance level. Results: A total of 800 individuals (561 women and 239 men) were evaluated. The prevalence of steatosis was 29.1%, and the male patients were most affected, presenting with more advanced grades of disease (p = 0.021), as follows: 119 grade 1 (51.0%); 94 grade 2 (40.4%); and 20 grade 3 (8.6%). The median age patients' was 46 years. Conclusion: In the present study sample, the prevalence of hepatic steatosis was high, particularly in the male patients. Ultrasonography is suggested as a first choice for the diagnosis of this condition, considering its wide availability, low cost and absence of side effects or risks to the patient.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Image segmentation of natural scenes constitutes a major problem in machine vision. This paper presents a new proposal for the image segmentation problem which has been based on the integration of edge and region information. This approach begins by detecting the main contours of the scene which are later used to guide a concurrent set of growing processes. A previous analysis of the seed pixels permits adjustment of the homogeneity criterion to the region's characteristics during the growing process. Since the high variability of regions representing outdoor scenes makes the classical homogeneity criteria useless, a new homogeneity criterion based on clustering analysis and convex hull construction is proposed. Experimental results have proven the reliability of the proposed approach

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: The aim of this study was to investigate the use of sentinel lymph node biopsy (SLNB) and whole body positron emission tomography (PET), with emphasis on surgical treatment and prognosis, in the detection of clinically occult metastases in patients with clinically localized cutaneous melanoma. Patients and methods: The study population consisted of 1255 patients with clinical stage I–II cutaneous melanoma, operated at Turku University Hospital between 1983 and 2007. 334 patients underwent SLNB and they were compared to 921 retrospective patients. A subgroup of 30 symptom-free patients with high risk melanoma underwent prospectively whole body PET 6–24 months postoperatively. Results: Overall, the disease-specific survival rate was 84.4 % at five years. Sex, Breslow thickness, age and nodal status were independent prognostic factors for survival. SLNB revealed occult nodal metastases in 17 % of the patients. There was no significant difference in disease-specific overall survival between SLNB patients and controls, but the nodal disease-free time was significantly longer suggesting better local control after SLNB and subsequent completion lymph node dissection. The followup time was different between the study cohorts and initial surgery was performed during different time periods. SLNB detected micrometastases in seven of 155 patients (4.5 %) with thin T1 primary melanoma and in four of 25 patients (16 %) with head and neck melanoma. In six of 30 asymptomatic patients with high risk melanoma (20 %), whole body PET detected occult distant metastases. Conclusion: Both SLNB and whole body PET were reliable methods to detect clinically occult metastases in patients with cutaneous melanoma. This upstaging altered the treatment in each case.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Effective treatment for breast cancer requires accurate preoperative planning, developing and implementing a consistent definition of margin clearance, and using tools that provide detailed real-time intraoperative information on margin status. Intraoperative ultrasound (IOUS) may fulfil these requirements and may offer few advantages that other preoperative localization and intraoperative margin assessment techniques may notPurpose: The goal of the present work is to determine how accurate the intraoperative ultrasound should be to acquire complete surgical excision with negative histological margins in patients undergoing Breast Conservative SurgeryDesign: A diagnostic test study with a cross-sectional design carried out in a tertiary referral hospital in Girona within a Breast Pathology UnitParticipants: Women diagnosed with breast cancer undergoing a Breast Conservative Surgery in the Breast Pathology Unit at Hospital Universitari de Girona Dr. Josep Trueta