939 resultados para Tropical deforestation, simulation model.


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The first goal of this study is to analyse a real-world multiproduct onshore pipeline system in order to verify its hydraulic configuration and operational feasibility by constructing a simulation model step by step from its elementary building blocks that permits to copy the operation of the real system as precisely as possible. The second goal is to develop this simulation model into a user-friendly tool that one could use to find an “optimal” or “best” product batch schedule for a one year time period. Such a batch schedule could change dynamically as perturbations occur during operation that influence the behaviour of the entire system. The result of the simulation, the ‘best’ batch schedule is the one that minimizes the operational costs in the system. The costs involved in the simulation are inventory costs, interface costs, pumping costs, and penalty costs assigned to any unforeseen situations. The key factor to determine the performance of the simulation model is the way time is represented. In our model an event based discrete time representation is selected as most appropriate for our purposes. This means that the time horizon is divided into intervals of unequal lengths based on events that change the state of the system. These events are the arrival/departure of the tanker ships, the openings and closures of loading/unloading valves of storage tanks at both terminals, and the arrivals/departures of trains/trucks at the Delivery Terminal. In the feasibility study we analyse the system’s operational performance with different Head Terminal storage capacity configurations. For these alternative configurations we evaluated the effect of different tanker ship delay magnitudes on the number of critical events and product interfaces generated, on the duration of pipeline stoppages, the satisfaction of the product demand and on the operative costs. Based on the results and the bottlenecks identified, we propose modifications in the original setup.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The lack of analytical models that can accurately describe large-scale networked systems makes empirical experimentation indispensable for understanding complex behaviors. Research on network testbeds for testing network protocols and distributed services, including physical, emulated, and federated testbeds, has made steady progress. Although the success of these testbeds is undeniable, they fail to provide: 1) scalability, for handling large-scale networks with hundreds or thousands of hosts and routers organized in different scenarios, 2) flexibility, for testing new protocols or applications in diverse settings, and 3) inter-operability, for combining simulated and real network entities in experiments. This dissertation tackles these issues in three different dimensions. First, we present SVEET, a system that enables inter-operability between real and simulated hosts. In order to increase the scalability of networks under study, SVEET enables time-dilated synchronization between real hosts and the discrete-event simulator. Realistic TCP congestion control algorithms are implemented in the simulator to allow seamless interactions between real and simulated hosts. SVEET is validated via extensive experiments and its capabilities are assessed through case studies involving real applications. Second, we present PrimoGENI, a system that allows a distributed discrete-event simulator, running in real-time, to interact with real network entities in a federated environment. PrimoGENI greatly enhances the flexibility of network experiments, through which a great variety of network conditions can be reproduced to examine what-if questions. Furthermore, PrimoGENI performs resource management functions, on behalf of the user, for instantiating network experiments on shared infrastructures. Finally, to further increase the scalability of network testbeds to handle large-scale high-capacity networks, we present a novel symbiotic simulation approach. We present SymbioSim, a testbed for large-scale network experimentation where a high-performance simulation system closely cooperates with an emulation system in a mutually beneficial way. On the one hand, the simulation system benefits from incorporating the traffic metadata from real applications in the emulation system to reproduce the realistic traffic conditions. On the other hand, the emulation system benefits from receiving the continuous updates from the simulation system to calibrate the traffic between real applications. Specific techniques that support the symbiotic approach include: 1) a model downscaling scheme that can significantly reduce the complexity of the large-scale simulation model, resulting in an efficient emulation system for modulating the high-capacity network traffic between real applications; 2) a queuing network model for the downscaled emulation system to accurately represent the network effects of the simulated traffic; and 3) techniques for reducing the synchronization overhead between the simulation and emulation systems.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Model predictive control (MPC) has often been referred to in literature as a potential method for more efficient control of building heating systems. Though a significant performance improvement can be achieved with an MPC strategy, the complexity introduced to the commissioning of the system is often prohibitive. Models are required which can capture the thermodynamic properties of the building with sufficient accuracy for meaningful predictions to be made. Furthermore, a large number of tuning weights may need to be determined to achieve a desired performance. For MPC to become a practicable alternative, these issues must be addressed. Acknowledging the impact of the external environment as well as the interaction of occupants on the thermal behaviour of the building, in this work, techniques have been developed for deriving building models from data in which large, unmeasured disturbances are present. A spatio-temporal filtering process was introduced to determine estimates of the disturbances from measured data, which were then incorporated with metaheuristic search techniques to derive high-order simulation models, capable of replicating the thermal dynamics of a building. While a high-order simulation model allowed for control strategies to be analysed and compared, low-order models were required for use within the MPC strategy itself. The disturbance estimation techniques were adapted for use with system-identification methods to derive such models. MPC formulations were then derived to enable a more straightforward commissioning process and implemented in a validated simulation platform. A prioritised-objective strategy was developed which allowed for the tuning parameters typically associated with an MPC cost function to be omitted from the formulation by separation of the conflicting requirements of comfort satisfaction and energy reduction within a lexicographic framework. The improved ability of the formulation to be set-up and reconfigured in faulted conditions was shown.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Historically, domestic tasks such as preparing food and washing and drying clothes and dishes were done by hand. In a modern home many of these chores are taken care of by machines such as washing machines, dishwashers and tumble dryers. When the first such machines came on the market customers were happy that they worked at all! Today, the costs of electricity and customers’ environmental awareness are high, so features such as low electricity, water and detergent use strongly influence which household machine the customer will buy. One way to achieve lower electricity usage for the tumble dryer and the dishwasher is to add a heat pump system. The function of a heat pump system is to extract heat from a lower temperature source (heat source) and reject it to a higher temperature sink (heat sink) at a higher temperature level. Heat pump systems have been used for a long time in refrigerators and freezers, and that industry has driven the development of small, high quality, low price heat pump components. The low price of good quality heat pump components, along with an increased willingness to pay extra for lower electricity usage and environmental impact, make it possible to introduce heat pump systems in other household products. However, there is a high risk of failure with new features. A number of household manufacturers no longer exist because they introduced poorly implemented new features, which resulted in low quality and product performance. A manufacturer must predict whether the future value of a feature is high enough for the customer chain to pay for it. The challenge for the manufacturer is to develop and produce a high-performance heat pump feature in a household product with high quality, predict future willingness to pay for it, and launch it at the right moment in order to succeed. Tumble dryers with heat pump systems have been on the market since 2000. Paper I reports on the development of a transient simulation model of a commercial heat pump tumble dryer. The measured and simulated results were compared with good similarity. The influence of the size of the compressor and the condenser was investigated using the validated simulation model. The results from the simulation model show that increasing the cylinder volume of the compressor by 50% decreases the drying time by 14% without using more electricity.  Paper II is a concept study of adding a heat pump system to a dishwasher in order to decrease the total electricity usage. The dishwasher, dishware and water are heated by the condenser, and the evaporator absorbs the heat from a water tank. The majority of the heat transfer to the evaporator occurs when ice is generated in the water tank. An experimental setup and a transient simulation model of a heat pump dishwasher were developed. The simulation results show a 24% reduction in electricity use compared to a conventional dishwasher heated with an electric element. The simulation model was based on an experimental setup that was not optimised. During the study it became apparent that it is possible to decrease electricity usage even more with the next experimental setup.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objetivo: realizar un diagnóstico respecto a la oferta demanda de hemocomponentes, en el contexto epidemiológico colombiano para que sirva de base en la formulación de futuros modelos logísticos de cadena de suministro que permita responder eficientemente a las necesidades transfusionales del país Método: se realizó un estudio descriptivo retrospectivo basado en las fuentes oficiales de información colombiana respecto a condiciones epidemiológicas poblacionales y su relación respecto a captación y transfusión de sangre, así como las posibilidades de conexiones aéreas. Resultados: actualmente 62.3% de la captación es aportada principalmente por 19% de los bancos de sangre del país (16 / 82), ubicados en 8 ciudades del país las cuales evidencian mejores condiciones de salud e índices de densidad poblacional superiores al promedio nacional. Adicionalmente, desde estas ciudades se puede hacer cubrimiento de hemocomponentes en todo el territorio nacional dadas las condiciones de las conexiones aéreas. Conclusiones: es posible con base en el diagnostico presentado, plantear opciones que apunten a mejorar la eficiencia en la cadena de suministros de hemocomponentes, centralizando la captación de sangre en las áreas donde se cuenta con mejores condiciones de salud y mayores densidades poblacionales. Lo anterior permitiría minimizar los porcentajes de incineración de unidades de glóbulos rojos por vencimiento al mejorar las redes de distribución y de esta manera reducir costos de operación. Debe además fortalecerse la gestión de inventarios desde los servicios de transfusión para lograr minimizar las perdidas. Lo anterior requiere control gubernamental dado que al considerarse la sangre como un bien de interés público, su uso no puede ser indiscriminado.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Regarding canal management modernization, water savings and water delivery quality, the study presents two automatic canal control approaches of the PI (Proportional and Integral) type: the distant and the local downstream control modes. The two PI controllers are defined, tuned and tested using an hydraulic unsteady flow simulation model, particularly suitable for canal control studies. The PI control parameters are tuned using optimization tools. The simulations are done for a Portuguese prototype canal and the PI controllers are analyzed and compared considering a demand-oriented-canal operation. The paper presents and analyzes the two control modes answers for five different offtake types – gate controlled weir, gate controlled orifice, weir with or without adjustable height and automatic flow adjustable offtake. The simulation results are compared using water volumes performance indicators (considering the demanded, supplied and the effectives water volumes) and a time indicator, defined taking into account the time during which the demand discharges are effective discharges. Regarding water savings, the simulation results for the five offtake types prove that the local downstream control gives the best results (no water operational losses) and that the distant downstream control presents worse results in connection with the automatic flow adjustable offtakes. Considering the water volumes and time performance indicators, the best results are obtained for the automatic flow adjustable offtakes and the worse for the gate controlled orifices, followed by the weir with adjustable height.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Olive tree sap flow measurements were collected in an intensive orchard near Évora, Portugal, during the irrigation seasons of 2013 and 2014, to calculate daily tree transpiration rates (T_SF). Meteorological variables were also collected to calculate reference evapotranspiration (ETo). Both data were used to assess values of basal crop coefficient (Kcb) for the period of the sap flow observations. The soil water balance model SIMDualKc was calibrated with soil, biophysical ground data and sap flow measurements collected in 2013. Validated in 2014 with collected sap flow observations, the model was used to provide estimates of dual e single crop coefficients for 2014 crop growing season. Good agreement between model simulated daily transpiration rates and those obtained with sapflow measurements was observed for 2014 (R2=0.76, RMSE=0.20 mm d-1), the year of validation, with an estimation average absolute error (AAE) of 0.20 mm d-1. Olive modeled daily actual evapotranspiration resulted in atual ETc values of 0.87, 2.05 and 0.77 mm d-1 for 2014 initial, mid- and end-season, respectively. Actual crop coefficient (Kc act) values of 0.51, 0.43 and 0.67 were also obtained for the same periods, respectively. Higher Kc values during spring (initial stage) and autumn (end-stage) were published in FAO56, varying between 0.65 for Kc ini and 0.70 for Kc end. The lower Kc mid value of 0.43 obtained for the summer (mid-season) is also inconsistent with the FAO56 expected Kc mid value of 0.70 for the period. The modeled Kc results are more consistent with the ones published by Allen & Pereira [1] for olive orchards with effective ground cover of 0.25 to 0.5, which vary between 0.40 and 0.80 for Kc ini, 0.40–0.60 for Kc mid with no active ground cover, and 0.35–0.75 for Kc end, depending on ground cover. The SIMDualKc simulation model proved to be appropriate for obtaining evapotranspiration and crop coefficient values for our intensive olive orchard in southern Portugal.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Face à Directiva 2007/60/CE relativa à avaliação e gestão do risco de inundações, ao Decreto-Lei nº 344/2007 que aprova o Regulamento de Segurança de Barragens, ao aumento de áreas urbanizadas e às projecções dos modelos de clima para o fim do século, que apontam para o aumento da frequência e da intensidade da ocorrência de inundações causadas por eventos de precipitação intensa de curta duração, é crucial a definição de regras de operação nos reservatórios com controlo de cheias. O Reservatório de Magos pertence à bacia hidrográfica do rio Tejo, está situado no Concelho de Salvaterra de Magos e tem como usos principais a rega e o controlo de cheias. Este trabalho tem como objecto de estudo a definição das regras de operação (restrição no caudal descarregado) do Reservatório de Magos para controlo de cheias no troço a jusante. São aplicados o modelo hidrológico HEC-HMS 3.1.0, o modelo hidráulico HEC-RAS 3.1.3 e o modelo de simulação de reservatórios HEC-ResSim 3.O para o cálculo do hidrograma de cheia, da zona inundável e para simulação do balanço de água no reservatório, respectivamente. Como resultado são apresentadas as regras de operação (caudal máximo e mínimo a descarregar) do Reservatório de Magos para controlo da zona inundável a jusante, no caso de um evento de cheia. /ABSTRACT: Based on the Directive 2007/60/CE related to the Assessment and Management of Flood Risks, on the Decree-Law n. o 344/2007 which approves the Regulation for Dam Safety, the increased urban areas and to the projections of climate models by the end of the century which is pointing to an increased frequency and intensity of occurrence of floods caused by intense rainfall events of short duration, establishing rules of operation for flood control in reservoirs becomes crucial. The Magos Reservoir belongs to the river Tagus basin, located in the county of Salvaterra de Magos and has as its main uses the irrigation and flood control. This study aims to establish the rules of operation (flow discharged restriction) of the Reservoir of Magos for flood control in the downstream reach. The methodology used in the present work includes the application of the Hydrological model HEC-HMS 3.1.0, the Hydraulic model HEC-RAS 3.1.3 and a reservoir simulation model HEC-ResSim 3.0 to calculate the hydrograph of peak discharge, floodplain zone and simulate reservoir operations, respectively. As a result, the rules of operation (maximum flow and minimum discharge) of Magos Reservoir for flood control in a downstream reach in case of flood event are presented.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this thesis is to present the concept of simulation for automatic machines and how it might be used to test and debug software implemented for an automatic machine. The simulation is used to detect errors and allow corrections of the code before the machine has been built. Simulation permits testing different solutions and improving the software to get an optimized one. Additionally, simulation can be used to keep track of a machine after the installation in order to improve the production process during the machine’s life cycle. The central argument of this project is discussing the advantage of using virtual commissioning to test the implemented software in a virtual environment. Such an environment is getting benefit in avoiding potential damages as well as reduction of time to have the machine ready to work. Also, the use of virtual commissioning allows testing different solutions without high losses of time and money. Subsequently, an optimized solution could be found after testing different proposed solutions. The software implemented is based on the Object-Oriented Programming paradigm which implies different features such as encapsulation, modularity, and reusability of the code. Therefore, this way of programming helps to get simplified code that is easier to be understood and debugged as well as its high efficiency. Finally, different communication protocols are implemented in order to allow communication between the real plant and the simulation model. By the outcome that this communication provides, we might be able to gather all the necessary data for the simulation and the analysis, in real-time, of the production process in a way to improve it during the machine life cycle.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Hominid evolution in the late Miocene has long been hypothesized to be linked to the retreat of the tropical rainforest in Africa. One cause for the climatic and vegetation change often considered was uplift of Africa, but also uplift of the Himalaya and the Tibetan Plateau was suggested to have impacted rainfall distribution over Africa. Recent proxy data suggest that in East Africa open grassland habitats were available to the common ancestors of hominins and apes long before their divergence and do not find evidence for a closed rainforest in the late Miocene. We used the coupled global general circulation model CCSM3 including an interactively coupled dynamic vegetation module to investigate the impact of topography on African hydro-climate and vegetation. We performed sensitivity experiments altering elevations of the Himalaya and the Tibetan Plateau as well as of East and Southern Africa. The simulations confirm the dominant impact of African topography for climate and vegetation development of the African tropics. Only a weak influence of prescribed Asian uplift on African climate could be detected. The model simulations show that rainforest coverage of Central Africa is strongly determined by the presence of elevated African topography. In East Africa, despite wetter conditions with lowered African topography, the conditions were not favorable enough to maintain a closed rainforest. A discussion of the results with respect to other model studies indicates a minor importance of vegetation-atmosphere or ocean-atmosphere feedbacks and a large dependence of the simulated vegetation response on the land surface/vegetation model.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

I Medicane sono rari cicloni che si sviluppano sul Mar Mediterraneo e presentano caratteristiche dei cicloni tropicali, come la forma a spirale delle bande di nubi, un occhio privo di venti e nubi, venti intensi nella banda che circonda l’occhio e la presenza di un nucleo caldo. Nel presente lavoro, è stata compiuta un’analisi del Medicane Numa, verificatosi nel novembre del 2017, utilizzando gli output della simulazione del modello RAMS-ISAC. L’obiettivo di questa tesi è l’identificazione e la descrizione delle caratteristiche tropicali di Numa, focalizzandosi sulla descrizione dei diversi stadi di sviluppo del ciclone. Il sistema di bassa pressione è stato identificato utilizzando la pressione sul livello del mare, mentre l’anomalia termica e il vento orizzontale hanno permesso una descrizione della struttura del Medicane e del suo nucleo caldo. Un’illustrazione della struttura a spirale delle bande di nubi e dell’occhio è stata ottenuta con il grafico dei rapporti di mescolanza delle idrometeore di nubi e pioggia. Questi parametri hanno consentito di ricavare il diametro dell’occhio, pari a 75 km, mentre il diametro del Medicane è risultato 230 km. Numa ha registrato una velocità massima del vento in superficie di 20 m/s nella banda adiacente all’occhio del ciclone. Il diagramma di Hart dello spazio delle fasi del ciclone ha confermato la natura simil-tropicale di Numa e ne ha descritto l’evoluzione, identificando la transizione da sistema a caratteri tropicali a sistema ibrido. La traiettoria nello spazio delle fasi ha consentito l’identificazione delle sottofasi dell’evoluzione di Numa, confermate dai grafici dell’evoluzione temporale dei parametri menzionati in precedenza. L’analisi ha mostrato il ruolo cruciale della presenza di una struttura organizzata nel determinare l’intensità e la durata delle caratteristiche tropicali. Tutti i parametri hanno evidenziato la simmetria della struttura durante la persistente fase matura di Numa.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

Dissertation submitted in partial fulfillment of the requirements for the Degree of Master of Science in Geospatial Technologies.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

The ability to run General Circulation Models (GCMs) at ever-higher horizontal resolutions has meant that tropical cyclone simulations are increasingly credible. A hierarchy of atmosphere-only GCMs, based on the Hadley Centre Global Environmental Model (HadGEM1), with horizontal resolution increasing from approximately 270km to 60km (at 50N), is used to systematically investigate the impact of spatial resolution on the simulation of global tropical cyclone activity, independent of model formulation. Tropical cyclones are extracted from ensemble simulations and reanalyses of comparable resolutions using a feature-tracking algorithm. Resolution is critical for simulating storm intensity and convergence to observed storm intensities is not achieved with the model hierarchy. Resolution is less critical for simulating the annual number of tropical cyclones and their geographical distribution, which are well captured at resolutions of 135km or higher, particularly for Northern Hemisphere basins. Simulating the interannual variability of storm occurrence requires resolutions of 100km or higher; however, the level of skill is basin dependent. Higher resolution GCMs are increasingly able to capture the interannual variability of the large-scale environmental conditions that contribute to tropical cyclogenesis. Different environmental factors contribute to the interannual variability of tropical cyclones in the different basins: in the North Atlantic basin the vertical wind shear, potential intensity and low-level absolute vorticity are dominant, while in the North Pacific basins mid-level relative humidity and low-level absolute vorticity are dominant. Model resolution is crucial for a realistic simulation of tropical cyclone behaviour, and high-resolution GCMs are found to be valuable tools for investigating the global location and frequency of tropical cyclones.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

In Part I of this study it was shown that moving from a moisture-convergent- to a relative-humidity-dependent organized entrainment rate in the formulation for deep convection was responsible for significant advances in the simulation of the Madden – Julian Oscillation (MJO) in the ECMWF model. However, the application of traditional MJO diagnostics were not adequate to understand why changing the control on convection had such a pronounced impact on the representation of the MJO. In this study a set of process-based diagnostics are applied to the hindcast experiments described in Part I to identify the physical mechanisms responsible for the advances in MJO simulation. Increasing the sensitivity of the deep convection scheme to environmental moisture is shown to modify the relationship between precipitation and moisture in the model. Through dry-air entrainment, convective plumes ascending in low-humidity environments terminate lower in the atmosphere. As a result, there is an increase in the occurrence of cumulus congestus, which acts to moisten the mid troposphere. Due to the modified precipitation – moisture relationship more moisture is able to build up, which effectively preconditions the tropical atmosphere for the t ransition t o d eep convection. R esults from this study suggest that a tropospheric moisture control on convection is key to simulating the interaction between the convective heating and the large-scale wave forcing associated with the MJO.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

A study of intense hurricane-type vortices in the ECMWF operational model is reported. These vortices develop around day 4 in the forecast and occur in the tropical belt in areas and at times where intense tropical cyclones normally occur. The frequency resembles that observed over most tropical regions with a pronounced maximum in the western North Pacific. The life time of the vortices and their 3-dimensional structure agree in some fundamental way with observations although, because of the resolution, the systems are less intense than the observed ones. The general large-scale conditions for active and inactive cyclone periods are discussed. The model cyclones are sensitive to the sea-surface temperature and do not develop with sea surface temperatures lower than 28–29°C. The dynamical conditions favouring cyclone development are characterized by intense large-scale divergence in the upper troposphere. Cyclogenesis appears to take place when these conditions are found outside the equatorial zone and over oceans where the water is sufficiently warm.