910 resultados para Termografia, super-risoluzione, super-resolution, dispositivo di micro-movimentazione, prove termografiche sperimentali su pistone


Relevância:

40.00% 40.00%

Publicador:

Resumo:

国际反质子与离子大科学工程(FAIR)项目是一个大型的国际合作项目,其中Super-FRS超导二极磁体由中国科学院近代物理研究所研制。利用ADINA有限元程序对项目中的超导Super-FRS磁体线圈的失超过程进行了模拟分析。利用C程序对ADINA程序进行二次开发以便对有限元求解器的调用和载荷的控制。分析结果显示:在失超过程中产生的最大热应力为26 MPa,可能产生的声波频率在35 Hz左右。

Relevância:

40.00% 40.00%

Publicador:

Resumo:

介绍了Super-FRS超导二极磁铁的磁场优化和端部削斜方案,采用OPERA软件对活极头进行削斜计算,得出合理的活极头尺寸,使各场下的积分均匀度在要求范围内达到了±2×10-4。最后将计算的积分场均匀度与磁场测量的结果进行比较,结果吻合得较好,验证了这种端部活极头优化计算方法的正确性。

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The FAIR China Group (FCG), consisting of the Institute of Modern Physics (IMP Lanzhou), the Institute of Plasma Physics (ASIPP, Hefei) and the Institute of Electric Engineering (IEE, Beijing) developed and manufactured in cooperation with GSI, Germany a prototype of a superferric dipole for the Super-Fragment-Separator of the FAIR-project [1]. The dipole magnets of the separator will have a deflection radius of 12.5 m, a field up to 1.6 T, a gap of at least 170 mm and an effective length of more than 2 meters to bend ion beams with a rigidity from 2 T . m up to 20 T . m. The magnets operate at DC mode. These requirements led to a superferric design with a yoke weight of more than 50 tons and a maximum stored energy of more than 400 kJ. The principles of yoke, coil and cryostat construction will be presented. We will also show first results of tests and measurements realized at ASIPP and at IMP.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The Super-FRS (Super FRagment Separator) is a part of FAIR (Facility for Antiproton and Ion Research), which will be constructed at GSI, Germany by 17 countries. The Super-FRS comprises 24 superferric dipole magnets. The 2D and 3D magnetic field simulations of the prototype magnet are described in this paper. A passive trim slot and four chamfered removable poles are used to satisfy the required field homogeneity which is better than +/-3 x 10(-4) at 1.6 T, 0.8 T and 0.16 T in a wide elliptical useable aperture of 380 mm x 140 mm. Measurement results at various field levels are shown in this paper as well. It can be seen from the comparison of calculation and measurement results that the magnetic designs of the magnet fulfils the requirements.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

中国签订了为德国FAIR国际大科学工程加工SUPER-FRS/CR超导二极磁铁样机的合作备忘录。该超导二极磁铁属于常温铁芯、低温线圈的超导磁铁,该磁铁的磁场强度0.15~1.6T,偏转角度15°,偏转半径8125mm,磁场精度要求±1×10-4,磁铁总重量约50吨。磁铁铁芯采用0.5mm的硅钢片叠压成型,由中科院近代物理研究(IMP)所计算、设计制造,线圈采用4.2K液氦浸泡式超导线圈,由合肥等离子体所设计制造(IPP)。 超导磁体的力学性能分析一直是超导磁体的基础问题。本文利用有限元分析方法,借助有限分析工具ANSYS、ADINA、OPERA等,分析了超导磁体的电磁场,着重模拟计算了SUPER-FRS/CR超导二极磁铁的电磁力作用;模拟了降温过程,计算了杜瓦、线圈热应力的作用;并对SUPER-FRS/CR超导线圈进行地震载荷作用的模拟。对以上不同的受力作用所遵循的不同的机械设计准则,进行不同的分析,最后计算结果证明设计的结构是安全、可靠的。由于超导线圈的结构复杂,导致在线圈拐角的地方应力有些集中,但是并不影响结构的可靠性。 本文还介绍了超导实验线圈的一些工艺设计,例如超导线圈的绕制,低温材料的选择,电流引线的设计工艺,以及VPI工艺。并对实验磁体进行了一系列的低温性能测试,例如短样测试、降温实验等,获得了一些重要的低温实验参数。这些参数将为以后超导磁体的研制提供宝贵的依据

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Super-hydrophobic films with vinyl-modified silica nanoparticles (V-SiOx-NPs) were successfully prepared. The rough surface, which was composed of microstructures of disordered V-SiOx-NPs and nanostructures on the surface of V-SiOx-NPs, rather than the chemical composition devoted to the super-hydrophobicity of film. The relationship between contact angle and diameter of V-SiOx-NPs was then investigated. The sessile contact angles (CA) of films with 150-1600nm V-SiOx-NPs were around 166 regardless the diameter, while the film with 85 nm V-SiOx-NPs had the lowest CA of about 158. The packing manner of V-SiOx-NPs determined the air fraction on the surface and then the CA.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The surface of superground Mn-Zn ferrite single crystal may be identified as a self-affine fractal in the stochastic sense. The rms roughness increased as a power of the scale from 10(2) nm to 10(6) nm with the roughness exponent alpha = 0.17 +/- 0.04, and 0.11 +/- 0.06, for grinding feed rate of 15 and 10 mu m/rev, respectively. The scaling behavior coincided with the theory prediction well used for growing self-affine surfaces in the interested region for magnetic heads performance. The rms roughnesses increased with increase in the feed rate, implying that the feed rate is a crucial grinding parameter affecting the supersmooth surface roughness in the machining process.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Window design plays an important role in achieving energy efficient buildings and in providing thermal comfort of building occupants. This paper investigates a newly developed aerogel window and the potential improvement on the comfort factors of an office in relation to daylighting. Improved comfort levels can impact on health and wellbeing of building occupants leading to knock on effects on absenteeism and productivity. A simulation tool was presently created that will easily enable comparison of different façade design and their impact on heat and light transmission and therefore enable optimisation. One of the most important aspects of the present work was comparing the performance of the newly developed aerogel window against the more traditional Argon-filled, coated double-glazing. Whereas the aerogel window provided an extremely low heat-loss index of 0.3 W/m2K, the latter usually offered a centre-glazing U-value of 1.4 W/m2K. On a like-with-like basis the daylight transmission of the aerogel window was significantly lower than double-glazing. However, in view of low thermal loss larger areas of the former can be deployed. This article presents the influence of three key parameters that may lead to an optimum design: daylight, thermal loss and solar gain.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Sparks, S. & Self. S. et al., 2005: Super-eruptions: global effects and future threats. Report of a Geological Society of London Working Group (2nd (print) Edn.). Original (Web) edition available at www.geolsoc.org.uk/supereruptions.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We present a search for nonzero θ13 and deviations of sin2θ23 from 0.5 in the oscillations of atmospheric neutrino data from Super-Kamiokande I, II, and III. No distortions of the neutrino flux consistent with nonzero θ13 are found and both neutrino mass hierarchy hypotheses are in agreement with the data. The data are best fit at Δm2=2.1×10-3eV2, sin2θ13=0.0, and sin2θ23=0.5. In the normal (inverted) hierarchy θ13 and Δm2 are constrained at the one-dimensional 90% C.L. to sin2θ13<0.04(0.09) and 1.9(1.7)×10 -3<Δm2<2.6(2.7)×10-3eV2. The atmospheric mixing angle is within 0.407≤sin2θ23≤0.583 at 90% C.L. © 2010 The American Physical Society.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The outcomes for both (i) radiation therapy and (ii) preclinical small animal radio- biology studies are dependent on the delivery of a known quantity of radiation to a specific and intentional location. Adverse effects can result from these procedures if the dose to the target is too high or low, and can also result from an incorrect spatial distribution in which nearby normal healthy tissue can be undesirably damaged by poor radiation delivery techniques. Thus, in mice and humans alike, the spatial dose distributions from radiation sources should be well characterized in terms of the absolute dose quantity, and with pin-point accuracy. When dealing with the steep spatial dose gradients consequential to either (i) high dose rate (HDR) brachytherapy or (ii) within the small organs and tissue inhomogeneities of mice, obtaining accurate and highly precise dose results can be very challenging, considering commercially available radiation detection tools, such as ion chambers, are often too large for in-vivo use.

In this dissertation two tools are developed and applied for both clinical and preclinical radiation measurement. The first tool is a novel radiation detector for acquiring physical measurements, fabricated from an inorganic nano-crystalline scintillator that has been fixed on an optical fiber terminus. This dosimeter allows for the measurement of point doses to sub-millimeter resolution, and has the ability to be placed in-vivo in humans and small animals. Real-time data is displayed to the user to provide instant quality assurance and dose-rate information. The second tool utilizes an open source Monte Carlo particle transport code, and was applied for small animal dosimetry studies to calculate organ doses and recommend new techniques of dose prescription in mice, as well as to characterize dose to the murine bone marrow compartment with micron-scale resolution.

Hardware design changes were implemented to reduce the overall fiber diameter to <0.9 mm for the nano-crystalline scintillator based fiber optic detector (NanoFOD) system. Lower limits of device sensitivity were found to be approximately 0.05 cGy/s. Herein, this detector was demonstrated to perform quality assurance of clinical 192Ir HDR brachytherapy procedures, providing comparable dose measurements as thermo-luminescent dosimeters and accuracy within 20% of the treatment planning software (TPS) for 27 treatments conducted, with an inter-quartile range ratio to the TPS dose value of (1.02-0.94=0.08). After removing contaminant signals (Cerenkov and diode background), calibration of the detector enabled accurate dose measurements for vaginal applicator brachytherapy procedures. For 192Ir use, energy response changed by a factor of 2.25 over the SDD values of 3 to 9 cm; however a cap made of 0.2 mm thickness silver reduced energy dependence to a factor of 1.25 over the same SDD range, but had the consequence of reducing overall sensitivity by 33%.

For preclinical measurements, dose accuracy of the NanoFOD was within 1.3% of MOSFET measured dose values in a cylindrical mouse phantom at 225 kV for x-ray irradiation at angles of 0, 90, 180, and 270˝. The NanoFOD exhibited small changes in angular sensitivity, with a coefficient of variation (COV) of 3.6% at 120 kV and 1% at 225 kV. When the NanoFOD was placed alongside a MOSFET in the liver of a sacrificed mouse and treatment was delivered at 225 kV with 0.3 mm Cu filter, the dose difference was only 1.09% with use of the 4x4 cm collimator, and -0.03% with no collimation. Additionally, the NanoFOD utilized a scintillator of 11 µm thickness to measure small x-ray fields for microbeam radiation therapy (MRT) applications, and achieved 2.7% dose accuracy of the microbeam peak in comparison to radiochromic film. Modest differences between the full-width at half maximum measured lateral dimension of the MRT system were observed between the NanoFOD (420 µm) and radiochromic film (320 µm), but these differences have been explained mostly as an artifact due to the geometry used and volumetric effects in the scintillator material. Characterization of the energy dependence for the yttrium-oxide based scintillator material was performed in the range of 40-320 kV (2 mm Al filtration), and the maximum device sensitivity was achieved at 100 kV. Tissue maximum ratio data measurements were carried out on a small animal x-ray irradiator system at 320 kV and demonstrated an average difference of 0.9% as compared to a MOSFET dosimeter in the range of 2.5 to 33 cm depth in tissue equivalent plastic blocks. Irradiation of the NanoFOD fiber and scintillator material on a 137Cs gamma irradiator to 1600 Gy did not produce any measurable change in light output, suggesting that the NanoFOD system may be re-used without the need for replacement or recalibration over its lifetime.

For small animal irradiator systems, researchers can deliver a given dose to a target organ by controlling exposure time. Currently, researchers calculate this exposure time by dividing the total dose that they wish to deliver by a single provided dose rate value. This method is independent of the target organ. Studies conducted here used Monte Carlo particle transport codes to justify a new method of dose prescription in mice, that considers organ specific doses. Monte Carlo simulations were performed in the Geant4 Application for Tomographic Emission (GATE) toolkit using a MOBY mouse whole-body phantom. The non-homogeneous phantom was comprised of 256x256x800 voxels of size 0.145x0.145x0.145 mm3. Differences of up to 20-30% in dose to soft-tissue target organs was demonstrated, and methods for alleviating these errors were suggested during whole body radiation of mice by utilizing organ specific and x-ray tube filter specific dose rates for all irradiations.

Monte Carlo analysis was used on 1 µm resolution CT images of a mouse femur and a mouse vertebra to calculate the dose gradients within the bone marrow (BM) compartment of mice based on different radiation beam qualities relevant to x-ray and isotope type irradiators. Results and findings indicated that soft x-ray beams (160 kV at 0.62 mm Cu HVL and 320 kV at 1 mm Cu HVL) lead to substantially higher dose to BM within close proximity to mineral bone (within about 60 µm) as compared to hard x-ray beams (320 kV at 4 mm Cu HVL) and isotope based gamma irradiators (137Cs). The average dose increases to the BM in the vertebra for these four aforementioned radiation beam qualities were found to be 31%, 17%, 8%, and 1%, respectively. Both in-vitro and in-vivo experimental studies confirmed these simulation results, demonstrating that the 320 kV, 1 mm Cu HVL beam caused statistically significant increased killing to the BM cells at 6 Gy dose levels in comparison to both the 320 kV, 4 mm Cu HVL and the 662 keV, 137Cs beams.