918 resultados para Strain I-2


Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVES: To test the survival rates, and the technical and biological complication rates of customized zirconia and titanium abutments 5 years after crown insertion. MATERIAL AND METHODS: Twenty-two patients with 40 single implants in maxillary and mandibular canine and posterior regions were included. The implant sites were randomly assigned to zirconia abutments supporting all-ceramic crowns or titanium abutments supporting metal-ceramic crowns. Clinical examinations were performed at baseline, and at 6, 12, 36 and 60 months of follow-up. The abutments and reconstructions were examined for technical and/or biological complications. Probing pocket depth (PPD), plaque control record (PCR) and Bleeding on Probing (BOP) were assessed at abutments (test) and analogous contralateral teeth (control). Radiographs of the implants revealed the bone level (BL) on mesial (mBL) and distal sides (dBL). Data were statistically analyzed with nonparametric mixed models provided by Brunner and Langer and STATA (P < 0.05). RESULTS: Eighteen patients with 18 zirconia and 10 titanium abutments were available at a mean follow-up of 5.6 years (range 4.5-6.3 years). No abutment fracture or loss of a reconstruction occurred. Hence, the survival rate was 100% for both. Survival of implants supporting zirconia abutments was 88.9% and 90% for implants supporting titanium abutments. Chipping of the veneering ceramic occurred at three metal-ceramic crowns supported by titanium abutments. No significant differences were found at the zirconia and titanium abutments for PPD (meanPPD(ZrO2) 3.3 ± 0.6 mm, mPPD(T) (i) 3.6 ± 1.1 mm), PCR (mPCR(Z) (rO) (2) 0.1 ± 0.3, mPCR(T) (i) 0.3 ± 0.2) and BOP (mBOP(Z) (rO) (2) 0.5 ± 0.3, mBOP(T) (i) 0.6 ± 0.3). Moreover, the BL was similar at implants supporting zirconia and titanium abutments (mBL(Z) (rO) (2) 1.8 ± 0.5, dBL(Z) (rO) (2) 2.0 ± 0.8; mBL(T) (i) 2.0 ± 0.8, dBL(T) (i) 1.9 ± 0.8). CONCLUSIONS: There were no statistically or clinically relevant differences between the 5-year survival rates, and the technical and biological complication rates of zirconia and titanium abutments in posterior regions.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In this study, we investigated if monolayer expansion of adult human articular chondrocytes (AHAC) on specific substrates regulates cell phenotype and post-expansion multilineage differentiation ability. AHAC isolated from cartilage biopsies of five donors were expanded on plastic dishes (PL), on dishes coated with collagen type II (COL), or on slides coated with a ceramic material (Osteologic, OS). The phenotype of expanded chondrocytes was assessed by flow cytometry and real-time RT-PCR. Cells were then cultured in previously established conditions promoting differentiation toward the chondrogenic or osteogenic lineage. AHAC differentiation was assessed histologically, biochemically, and by real-time RT-PCR. As compared to PL-expanded AHAC, those expanded on COL did not exhibit major phenotypic changes, whereas OS-expanded cells expressed (i) higher bone sialoprotein (BSP) (22.6-fold) and lower collagen type II (9.3-fold) mRNA levels, and (ii) lower CD26, CD90 and CD140 surface protein levels (1.4-11.1-fold). Following chondrogenic differentiation, COL-expanded AHAC expressed higher mRNA levels of collagen type II (2.3-fold) and formed tissues with higher glycosaminoglycan (GAG) contents (1.7-fold), whereas OS-expanded cells expressed 16.5-fold lower collagen type II and generated pellets with 2.0-fold lower GAG contents. Following osteogenic differentiation, OS-expanded cells expressed higher levels of BSP (3.9-fold) and collagen type I (2.8-fold) mRNA. In summary, AHAC expansion on COL or OS modulated the de-differentiated cell phenotype and improved the cell differentiation capacity respectively toward the chondrogenic or osteogenic lineage. Phenotypic changes induced by AHAC expansion on specific substrates may mimic pathophysiological events occurring at different stages of osteoarthritis and may be relevant for the engineering of osteochondral tissues.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVE: To compare the effectiveness and safety of intraarticular high-molecular hylan with standard preparations of hyaluronic acids in osteoarthritis of the knee. METHODS: We performed a systematic review and meta-analysis of randomized controlled trials comparing hylan with a hyaluronic acid in patients with knee osteoarthritis. Trials were identified by systematic searches of Central, Medline, EMBase, Cinahl, the Food and Drug Administration, and Science Citation Index supplemented by hand searches of conference proceedings and reference lists (last update November 2006). Literature screening and data extraction were performed in duplicate. Effect sizes were calculated from differences in means of pain-related outcomes between treatment and control groups at the end of the trial, divided by the pooled standard deviation. Trials were combined using random-effects meta-analysis. RESULTS: Thirteen trials with a pooled total of 2,085 patients contributed to the meta-analysis. The pooled effect size was -0.27 (95% confidence interval [95% CI] -0.55, 0.01), favoring hylan, but between-trial heterogeneity was high (I(2) = 88%). Trials with blinded patients, adequate concealment of allocation, and an intent-to-treat analysis had pooled effect sizes near null. The meta-analyses on safety revealed an increased risk associated with hylan for any local adverse events (relative risk [RR] 1.91; 95% CI 1.04, 3.49; I(2) = 28%) and for flares (RR 2.04; 95% CI 1.18, 3.53; I(2) = 0%). CONCLUSION: Given the likely lack of a superior effectiveness of hylan over hyaluronic acids and the increased risk of local adverse events associated with hylan, we discourage the use of intraarticular hylan in patients with knee osteoarthritis in clinical research or practice.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND: Noninvasive intraocular pressure (IOP) measurement in mice is critically important for understanding the pathophysiology of glaucoma. Rebound tonometry is one of the methods that can be used for obtaining such measurements. We evaluated the ability of the rebound tonometer (RT) to determine IOP differences among various mouse strains and whether differences in corneal thickness may affect IOP measurements in these animals. MATERIALS AND METHODS: Five different commonly used mouse strains (BALB/C, CBA/CAHN, AKR/J, CBA/J, and 129P3/J) were used. IOP was measured in eyes from 12 nonsedated animals (6 male and 6 female) from each strain at 2 to 3 months of age using the RT. IOPs were measured in all animals, on 2 different days between 10 AM and 12 PM. Subsequently, a number of eyes from each strain were cannulated to provide a calibration curve specific for that strain. Tonometer readings for all strains were converted to apparent IOP values using the calibration data obtained from the calibration curve of the respective strain. For comparison purposes, IOP values were also obtained using the C57BL/6 calibration data previously reported. IOP for the 5 strains, male and female animals, and the different occasion of measurement were compared using repeat measures analysis of variance. The central corneal thickness (CCT) of another group of 8 male animals from each of the 5 strains was also measured using an optical low coherence reflectometry (OLCR) pachymeter modified for use with mice. CCT values were correlated to mean IOPs of male animals and to the slopes and intercept of individual strain calibration curves. RESULTS: Noninvasive IOP measurements confirm that the BALB/C strain has lower and the CBA/CAHN has higher relative IOPs than other mouse strains while the AKR/J, the CBA/J, and the 129P3/J strains have intermediate IOPs. There is a very good correlation of apparent IOP values obtained by RT with previously reported true IOPs obtained by cannulation. There was a small but statistically significant difference in IOP between male and female animals in 2 strains (129P3/J and AKR/J) with female mice having higher relative IOPs. No correlation between CCT and IOP was detected. CCT did not correlate with any of the constants describing the calibration curves in the various strains. CONCLUSIONS: Noninvasive IOP measurement in mice using the RT can be used to help elucidate IOP phenotype, after prior calibration of the tonometer. CCT has no effect on mouse IOP measurements using the RT.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVE: Recommendations for lower extremity osteoarthritis (OA) and exercise have been primarily based on knee studies. To provide more targeted recommendations for the hip, we gathered evidence for the efficacy of exercise for hip OA from randomized controlled trials. METHODS: A bibliographic search identified trials that were randomized, controlled, completed by >or=60% of subjects, and involved an exercise group (strengthening and/or aerobic) versus a non exercise control group for pain relief in hip OA. Two reviewers independently performed the data extraction and contacted the authors when necessary. Effect sizes (ES) of treatment versus control and the I(2) statistic to assess heterogeneity across trials were calculated. Trial data were combined using a random-effects meta-analysis. RESULTS: Nine trials met the inclusion criteria (1,234 subjects), 7 of which combined hip and knee OA; therefore, we contacted the authors who provided the data on hip OA patients. In comparing exercise treatment versus control, we found a beneficial effect of exercise with an ES of -0.38 (95% confidence interval [95% CI] -0.68, -0.08; P = 0.01), but with high heterogeneity (I(2) = 75%) among trials. Heterogeneity was caused by 1 trial consisting of an exercise intervention that was not administered in person. Removing this study left 8 trials (n = 493) with similar exercise strategy (specialized hands-on exercise training, all of which included at least some element of muscle strengthening), and demonstrated exercise benefit with an ES of -0.46 (95% CI -0.64, -0.28; P < 0.0001). CONCLUSION: Therapeutic exercise, especially with an element of strengthening, is an efficacious treatment for hip OA.

Relevância:

80.00% 80.00%

Publicador:

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND: Erythropoiesis-stimulating agents (ESAs) reduce anemia in cancer patients and may improve quality of life, but there are concerns that ESAs might increase mortality. OBJECTIVES: Our objectives were to examine the effect of ESAs and identify factors that modify the effects of ESAs on overall survival, progression free survival, thromboembolic and cardiovascular events as well as need for transfusions and other important safety and efficacy outcomes in cancer patients. SEARCH STRATEGY: We searched the Cochrane Library, Medline, Embase and conference proceedings for eligible trials. Manufacturers of ESAs were contacted to identify additional trials. SELECTION CRITERIA: We included randomized controlled trials comparing epoetin or darbepoetin plus red blood cell transfusions (as necessary) versus red blood cell transfusions (as necessary) alone, to prevent or treat anemia in adult or pediatric cancer patients with or without concurrent antineoplastic therapy. DATA COLLECTION AND ANALYSIS: We performed a meta-analysis of randomized controlled trials comparing epoetin alpha, epoetin beta or darbepoetin alpha plus red blood cell transfusions versus transfusion alone, for prophylaxis or therapy of anemia while or after receiving anti-cancer treatment. Patient-level data were obtained and analyzed by independent statisticians at two academic departments, using fixed-effects and random-effects meta-analysis. Analyses were according to the intention-to-treat principle. Primary endpoints were on study mortality and overall survival during the longest available follow-up, regardless of anticancer treatment, and in patients receiving chemotherapy. Tests for interactions were used to identify differences in effects of ESAs on mortality across pre-specified subgroups. The present review reports only the results for the primary endpoint. MAIN RESULTS: A total of 13933 cancer patients from 53 trials were analyzed, 1530 patients died on-study and 4993 overall. ESAs increased on study mortality (combined hazard ratio [cHR] 1.17; 95% CI 1.06-1.30) and worsened overall survival (cHR 1.06; 95% CI 1.00-1.12), with little heterogeneity between trials (I(2) 0%, p=0.87 and I(2) 7.1%, p=0.33, respectively). Thirty-eight trials enrolled 10441 patients receiving chemotherapy. The cHR for on study mortality was 1.10 (95% CI 0.98-1.24) and 1.04; 95% CI 0.97-1.11) for overall survival. There was little evidence for a difference between trials of patients receiving different cancer treatments (P for interaction=0.42). AUTHORS' CONCLUSIONS: ESA treatment in cancer patients increased on study mortality and worsened overall survival. For patients undergoing chemotherapy the increase was less pronounced, but an adverse effect could not be excluded.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND: Erythropoiesis-stimulating agents reduce anaemia in patients with cancer and could improve their quality of life, but these drugs might increase mortality. We therefore did a meta-analysis of randomised controlled trials in which these drugs plus red blood cell transfusions were compared with transfusion alone for prophylaxis or treatment of anaemia in patients with cancer. METHODS: Data for patients treated with epoetin alfa, epoetin beta, or darbepoetin alfa were obtained and analysed by independent statisticians using fixed-effects and random-effects meta-analysis. Analyses were by intention to treat. Primary endpoints were mortality during the active study period and overall survival during the longest available follow-up, irrespective of anticancer treatment, and in patients given chemotherapy. Tests for interactions were used to identify differences in effects of erythropoiesis-stimulating agents on mortality across prespecified subgroups. FINDINGS: Data from a total of 13 933 patients with cancer in 53 trials were analysed. 1530 patients died during the active study period and 4993 overall. Erythropoiesis-stimulating agents increased mortality during the active study period (combined hazard ratio [cHR] 1.17, 95% CI 1.06-1.30) and worsened overall survival (1.06, 1.00-1.12), with little heterogeneity between trials (I(2) 0%, p=0.87 for mortality during the active study period, and I(2) 7.1%, p=0.33 for overall survival). 10 441 patients on chemotherapy were enrolled in 38 trials. The cHR for mortality during the active study period was 1.10 (0.98-1.24), and 1.04 (0.97-1.11) for overall survival. There was little evidence for a difference between trials of patients given different anticancer treatments (p for interaction=0.42). INTERPRETATION: Treatment with erythropoiesis-stimulating agents in patients with cancer increased mortality during active study periods and worsened overall survival. The increased risk of death associated with treatment with these drugs should be balanced against their benefits. FUNDING: German Federal Ministry of Education and Research, Medical Faculty of University of Cologne, and Oncosuisse (Switzerland).

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND: Osteoarthritis is the most common form of joint disease and the leading cause of pain and disability in the elderly. S-Adenosylmethionine may be a viable treatment option but the evidence about its effectiveness and safety is equivocal. OBJECTIVES: We set out to compare S-Adenosylmethionine (SAMe) with placebo or no specific intervention in terms of effects on pain and function and safety outcomes in patients with knee or hip osteoarthritis. SEARCH STRATEGY: We searched CENTRAL, MEDLINE, EMBASE, CINAHL and PEDro up to 5 August 2008, checked conference proceedings and reference lists, and contacted authors. SELECTION CRITERIA: Randomised or quasi-randomised controlled trials that compared SAMe at any dosage and in any formulation with placebo or no intervention in patients with osteoarthritis of the knee or hip. DATA COLLECTION AND ANALYSIS: Two independent authors extracted data using standardised forms. We contacted investigators to obtain missing outcome information. We calculated standardised mean differences (SMDs) for pain and function, and relative risks for safety outcomes. We combined trials using inverse-variance random-effects meta-analysis. MAIN RESULTS: Four trials including 656 patients were included in the systematic review, all compared SAMe with placebo. The methodological quality and the quality of reporting were poor. For pain, the analysis indicated a small SMD of -0.17 (95% CI -0.34 to 0.01), corresponding to a difference in pain scores between SAMe and placebo of 0.4 cm on a 10 cm VAS, with no between trial heterogeneity (I(2) = 0). For function, the analysis suggested a SMD of 0.02 (95% CI -0.68 to 0.71) with a moderate degree of between-trial heterogeneity (I2 = 54%). The meta-analyses of the number of patients experiencing any adverse event, and withdrawals or drop-outs due to adverse events, resulted in relative risks of 1.27 (95% CI 0.94 to 1.71) and 0.94 (95% CI 0.48 to 1.86), respectively, but confidence intervals were wide and tests for overall effect were not significant. No trial provided information concerning the occurrence of serious adverse events. AUTHORS' CONCLUSIONS: The current systematic review is inconclusive, hampered by the inclusion of mainly small trials of questionable quality. The effects of SAMe on both pain and function may be potentially clinically relevant and, although effects are expected to be small, deserve further clinical evaluation in adequately sized randomised, parallel-group trials in patients with knee or hip osteoarthritis. Meanwhile, routine use of SAMe should not be advised.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND: Osteoarthritis is the most common form of joint disease and the leading cause of pain and physical disability in the elderly. Transcutaneous electrical nerve stimulation (TENS), interferential current stimulation and pulsed electrostimulation are used widely to control both acute and chronic pain arising from several conditions, but some policy makers regard efficacy evidence as insufficient. OBJECTIVES: To compare transcutaneous electrostimulation with sham or no specific intervention in terms of effects on pain and withdrawals due to adverse events in patients with knee osteoarthritis. SEARCH STRATEGY: We updated the search in CENTRAL, MEDLINE, EMBASE, CINAHL and PEDro up to 5 August 2008, checked conference proceedings and reference lists, and contacted authors. SELECTION CRITERIA: Randomised or quasi-randomised controlled trials that compared transcutaneously applied electrostimulation with a sham intervention or no intervention in patients with osteoarthritis of the knee. DATA COLLECTION AND ANALYSIS: We extracted data using standardised forms and contacted investigators to obtain missing outcome information. Main outcomes were pain and withdrawals or dropouts due to adverse events. We calculated standardised mean differences (SMDs) for pain and relative risks for safety outcomes and used inverse-variance random-effects meta-analysis. The analysis of pain was based on predicted estimates from meta-regression using the standard error as explanatory variable. MAIN RESULTS: In this update we identified 14 additional trials resulting in the inclusion of 18 small trials in 813 patients. Eleven trials used TENS, four interferential current stimulation, one both TENS and interferential current stimulation, and two pulsed electrostimulation. The methodological quality and the quality of reporting was poor and a high degree of heterogeneity among the trials (I(2) = 80%) was revealed. The funnel plot for pain was asymmetrical (P < 0.001). The predicted SMD of pain intensity in trials as large as the largest trial was -0.07 (95% CI -0.46 to 0.32), corresponding to a difference in pain scores between electrostimulation and control of 0.2 cm on a 10 cm visual analogue scale. There was little evidence that SMDs differed on the type of electrostimulation (P = 0.94). The relative risk of being withdrawn or dropping out due to adverse events was 0.97 (95% CI 0.2 to 6.0). AUTHORS' CONCLUSIONS: In this update, we could not confirm that transcutaneous electrostimulation is effective for pain relief. The current systematic review is inconclusive, hampered by the inclusion of only small trials of questionable quality. Appropriately designed trials of adequate power are warranted.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Cannabinoid receptor 2 (CB(2) receptor) ligands are potential candidates for the therapy of chronic pain, inflammatory disorders, atherosclerosis, and osteoporosis. We describe the development of pharmacophore models for CB(2) receptor ligands, as well as a pharmacophore-based virtual screening workflow, which resulted in 14 hits for experimental follow-up. Seven compounds were identified with K(i) values below 25 microM. The CB(2) receptor-selective pyridine tetrahydrocannabinol analogue 8 (K(i) = 1.78 microM) was identified as a CB(2) partial agonist. Acetamides 12 (K(i) = 1.35 microM) and 18 (K(i) = 2.1 microM) represent new scaffolds for CB(2) receptor-selective antagonists and inverse agonists, respectively. Overall, our pharmacophore-based workflow yielded three novel scaffolds for the chemical development of CB(2) receptor ligands.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND Antiretroviral drugs have been shown to reduce risk of mother-to-child transmission of human immunodeficiency virus (HIV) and are also widely used for post-exposure prophylaxis for parenteral and sexual exposures. Sexual transmission may be lower in couples in which one partner is infected with HIV and the other is not and the infected partner is on antiretroviral therapy (ART). OBJECTIVES To determine if ART use in an HIV-infected member of an HIV-discordant couple is associated with lower risk of HIV transmission to the uninfected partner compared to untreated discordant couples. SEARCH METHODS We used standard Cochrane methods to search electronic databases and conference proceedings with relevant search terms without limits to language. SELECTION CRITERIA Randomised controlled trials (RCT), cohort studies and case-control studies of HIV-discordant couples in which the HIV-infected member of the couple was being treated or not treated with ART DATA COLLECTION AND ANALYSIS: Abstracts of all trials identified by electronic or bibliographic scanning were examined independently by two authors. We initially identified 3,833 references and examined 87 in detail for study eligibility. Data were abstracted independently using a standardised abstraction form. MAIN RESULTS One RCT and nine observational studies were included in the review. These ten studies identified 2,112 episodes of HIV transmission, 1,016 among treated couples and 1,096 among untreated couples. The rate ratio for the single randomised controlled trial was 0.04 [95% CI 0.00, 0.27]. All index partners in this study had CD4 cell counts at baseline of 350-550 cells/µL. Similarly, the summary rate ratio for the nine observational studies was 0.58 [95% CI 0.35, 0.96], with substantial heterogeneity (I(2)=64%). After excluding two studies with inadequate person-time data, we estimated a summary rate ratio of 0.36 [95% CI 0.17, 0.75] with substantial heterogeneity (I(2)=62%). We also performed subgroup analyses among the observational studies to see if the effect of ART on prevention of HIV differed by the index partner's CD4 cell count. Among couples in which the infected partner had ≥350 CD4 cells/µL, we estimated a rate ratio of 0.12 [95% CI 0.01, 1.99]. In this subgroup, there were 247 transmissions in untreated couples and 30 in treated couples. AUTHORS' CONCLUSIONS ART is a potent intervention for prevention of HIV in discordant couples in which the index partner has ≤550 CD4 cells/µL. A recent multicentre RCT confirms the suspected benefit seen in earlier observational studies and reported in more recent ones. Questions remain about durability of protection, the balance of benefits and adverse events associated with earlier therapy, long-term adherence and transmission of ART-resistant strains to partners. Resource limitations and implementation challenges must also be addressed.Counselling, support, and follow up, as well as mutual disclosure, may have a role in supporting adherence, so programmes should be designed with these components. In addition to ART provision, the operational aspects of delivering such programmes must be considered.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

INTRODUCTION Light cure of resin-based adhesives is the mainstay of orthodontic bonding. In recent years, alternatives to conventional halogen lights offering reduced curing time and the potential for lower attachment failure rates have emerged. The relative merits of curing lights in current use, including halogen-based lamps, light-emitting diodes (LEDs), and plasma arc lights, have not been analyzed systematically. In this study, we reviewed randomized controlled trials and controlled clinical trials to assess the risks of attachment failure and bonding time in orthodontic patients in whom brackets were cured with halogen lights, LEDs, or plasma arc systems. METHODS Multiple electronic database searches were undertaken, including MEDLINE, EMBASE, and the Cochrane Oral Health Group's Trials Register, CENTRAL. Language restrictions were not applied. Unpublished literature was searched on ClinicalTrials.gov, the National Research Register, Pro-Quest Dissertation Abstracts, and Thesis database. Search terms included randomized controlled trial, controlled clinical trial, random allocation, double blind method, single blind method, orthodontics, LED, halogen, bond, and bracket. Authors of primary studies were contacted as required, and reference lists of the included studies were screened. RESULTS Randomized controlled trials and clinical controlled trials directly comparing conventional halogen lights, LEDs, or plasma arc systems involving patients with full arch, fixed, or bonded orthodontic appliances (not banded) with follow-up periods of a minimum of 6 months were included. Using predefined forms, 2 authors undertook independent extraction of articles; disagreements were resolved by discussion. The assessment of the risk of bias of the randomized controlled trials was based on the Cochrane Risk of Bias tool. Ten studies met the inclusion criteria; 2 were excluded because of high risk of bias. In the comparison of bond failure risk with halogen lights and plasma arc lights, 1851 brackets were included in both groups. Little statistical heterogeneity was observed in this analysis (I(2) = 4.8%; P = 0.379). There was no statistical difference in bond failure risk between the groups (OR, 0.92; 95% CI, 0.68-1.23; prediction intervals, 0.54, 1.56). Similarly, no statistical difference in bond failure risk was observed in the meta-analysis comparing halogen lights and LEDs (OR, 0.96; 95% CI, 0.64-1.44; prediction intervals, 0.07, 13.32). The pooled estimates from both comparisons were OR, 0.93; 95% CI, 0.74-1.17; and prediction intervals, 0.69, 1.17. CONCLUSIONS There is no evidence to support the use of 1 light cure type over another based on risk of attachment failure.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND Fractures of the mandible (lower jaw) are a common occurrence and usually related to interpersonal violence or road traffic accidents. Mandibular fractures may be treated using open (surgical) and closed (non-surgical) techniques. Fracture sites are immobilized with intermaxillary fixation (IMF) or other external or internal devices (i.e. plates and screws) to allow bone healing. Various techniques have been used, however uncertainty exists with respect to the specific indications for each approach. OBJECTIVES The objective of this review is to provide reliable evidence of the effects of any interventions either open (surgical) or closed (non-surgical) that can be used in the management of mandibular fractures, excluding the condyles, in adult patients. SEARCH METHODS We searched the following electronic databases: the Cochrane Oral Health Group's Trials Register (to 28 February 2013), the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library 2013, Issue 1), MEDLINE via OVID (1950 to 28 February 2013), EMBASE via OVID (1980 to 28 February 2013), metaRegister of Controlled Trials (to 7 April 2013), ClinicalTrials.gov (to 7 April 2013) and the WHO International Clinical Trials Registry Platform (to 7 April 2013). The reference lists of all trials identified were checked for further studies. There were no restrictions regarding language or date of publication. SELECTION CRITERIA Randomised controlled trials evaluating the management of mandibular fractures without condylar involvement. Any studies that compared different treatment approaches were included. DATA COLLECTION AND ANALYSIS At least two review authors independently assessed trial quality and extracted data. Results were to be expressed as random-effects models using mean differences for continuous outcomes and risk ratios for dichotomous outcomes with 95% confidence intervals. Heterogeneity was to be investigated to include both clinical and methodological factors. MAIN RESULTS Twelve studies, assessed as high (six) and unclear (six) risk of bias, comprising 689 participants (830 fractures), were included. Interventions examined different plate materials and morphology; use of one or two lag screws; microplate versus miniplate; early and delayed mobilization; eyelet wires versus Rapid IMF™ and the management of angle fractures with intraoral access alone or combined with a transbuccal approach. Patient-oriented outcomes were largely ignored and post-operative pain scores were inadequately reported. Unfortunately, only one or two trials with small sample sizes were conducted for each comparison and outcome. Our results and conclusions should therefore be interpreted with caution. We were able to pool the results for two comparisons assessing one outcome. Pooled data from two studies comparing two miniplates versus one miniplate revealed no significant difference in the risk of post-operative infection of surgical site (risk ratio (RR) 1.32, 95% CI 0.41 to 4.22, P = 0.64, I(2) = 0%). Similarly, no difference in post-operative infection between the use of two 3-dimensional (3D) and standard (2D) miniplates was determined (RR 1.26, 95% CI 0.19 to 8.13, P = 0.81, I(2) = 27%). The included studies involved a small number of participants with a low number of events. AUTHORS' CONCLUSIONS This review illustrates that there is currently inadequate evidence to support the effectiveness of a single approach in the management of mandibular fractures without condylar involvement. The lack of high quality evidence may be explained by clinical diversity, variability in assessment tools used and difficulty in grading outcomes with existing measurement tools. Until high level evidence is available, treatment decisions should continue to be based on the clinician's prior experience and the individual circumstances.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Researcher allegiance (RA) is widely discussed as a risk of bias in psychotherapy outcome research. The relevance attached to RA bias is related to meta-analyses demonstrating an association of RA with treatment effects. However, recent meta-analyses have yielded mixed results. To provide more clarity on the magnitude and robustness of the RA-outcome association this article reports on a meta-meta-analysis summarizing all available meta-analytic estimates of the RA-outcome association. Random-effects methods were used. Primary study overlap was controlled. Thirty meta-analyses were included. The mean RA-outcome association was r=.262 (p=.002, I(2)=28.98%), corresponding to a moderate effect size. The RA-outcome association was robust across several moderating variables including characteristics of treatment, population, and the type of RA assessment. Allegiance towards the RA bias hypothesis moderated the RA-outcome association. The findings of this meta-meta-analysis suggest that the RA-outcome association is substantial and robust. Implications for psychotherapy outcome research are discussed.