956 resultados para Solar heating.


Relevância:

20.00% 20.00%

Publicador:

Resumo:

在四辊冷轧试验机和Gleeble-1500试验机上进行了热轧微碳钢板的冷轧和退火试验。用D/max-RC衍射仪测量了试样的,/”层织构,并用Roe软件进行了ODF分析。研究表明,所研究的热轧微碳深冲板压下率约为75%,退火升温速度为20-40℃/h时,试样为{111}织构特征;压下率较大(80%)时,退火织构为较弱的{111}组分。无论{111}织构还是非{111}织构都是在形核阶段开始形成,在晶粒长大优先长大,受到定向形核和选择生长双重机制的作用。

Relevância:

20.00% 20.00%

Publicador:

Resumo:

对乙烷裂解制造乙烯的非平衡过程进行了分析,为了获得高的乙烯产率,需准确控制裂解停留时间并提高裂解反应温度,探讨了目前工业生产中普遍采用的管式裂解炉的特性及局限,这种管式裂解炉的性能虽己接近完善,但仍不能满足裂解工艺需求,对几种利用激波控制加热方法生产乙烯的发明及其不足进行了评述,提出新颖的反向超声速射流混合加热方法,该方法能满足裂解制造乙烯的要求。

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Great differences between municipal solid wastes(MSW)produced at different places and different times in terms of such parameters as physical ingredient and heating value lead to difficulty in effective handling of MSW. In this paper, ingredient, heating value and their temporal varying trends of typical MSW in Beijing were continuously measured and analyzed. With consideration of the process in pyrolysis and incineration, correlation between physical ingredients and heating values was induced, favorable for evaluation of heating value needed in handling of MSW from simple analysis of physical ingredients of it.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report on a quantum dot sensitized solar cell (QDSSC) based on ZnO nanorod coated vertically aligned carbon nanotubes (VACNTs). Electrochemical impedance spectroscopy shows that the electron lifetime for the device based on VACNT/ZnO/CdSe is longer than that for a device based on ZnO/CdSe, indicating that the charge recombination at the interface is reduced by the presence of the VACNTs. Due to the increased surface area and longer electron lifetime, a power conversion efficiency of 1.46% is achieved for the VACNT/ZnO/CdSe devices under an illumination of one Sun (AM 1.5G, 100 mW/cm2). © 2010 Elsevier B.V.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The natural ventilation of a well-mixed, pre-heated room with a point source of heating, and openings at the base and roof is investigated. The transient draining associated with the room being warmer than the exterior combined with the convective ow produced by the point source of heat leads to a fascinating series of transient ow regimes as the system evolves to the two-layer steady-state regime described by Linden, Lane-Ser_ and Smeed [1]. As the room begins to ventilate, a turbulent plume rises from the point source of heat to the ceiling, and typically forms a deepening layer of hot air. However, with a weak heat source, then at some point the ascending plume will intrude beneath the layer of original uid. Otherwise, the ascending plume always reaches the top of the room as the system evolves to a steady state. We develop a simpli_ed model of the transient evolution and test this with some new laboratory experiments. We conclude with a discussion of the implications of our results for real buildings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In winter, natural ventilation can be achieved either through mixing ventilation or upward displacement ventilation (P.F. Linden, The fluid mechanics of natural ventilation, Annual Review of Fluid Mechanics 31 (1999) pp. 201-238). We show there is a significant energy saving possible by using mixing ventilation, in the case that the internal heat gains are significant, and illustrate these savings using an idealized model, which predicts that with internal heat gains of order 0.1 kW per person, mixing ventilation uses of a fraction of order 0.2-0.4 of the heat load of displacement ventilation assuming a well-insulated building. We then describe a strategy for such mixing natural ventilation in an atrium style building in which the rooms surrounding the atrium are able to vent directly to the exterior and also through the atrium to the exterior. The results are motivated by the desire to reduce the energy burden in large public buildings such as hospitals, schools or office buildings centred on atria. We illustrate a strategy for the natural mixing ventilation in order that the rooms surrounding the atrium receive both pre-heated but also sufficiently fresh air, while the central atrium zone remains warm. We test the principles with some laboratory experiments in which a model air chamber is ventilated using both mixing and displacement ventilation, and compare the energy loads in each case. We conclude with a discussion of the potential applications of the approach within the context of open plan atria type office buildings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recently ZnO nanowire films have been used in very promising and inexpensive dye-sensitized solar cells (DSSC). It was found that the performance of the devices can be enhanced by functionalising the nanowires with a thin metal oxide coating. This nm-scale shell is believed to tailor the electronic structure of the nanowire, and help the absorption of the dye. Core-shell ZnO nanowire structures are synthesised at low temperature (below 120°C) by consecutive hydrothermal growth steps. Different materials are investigated for the coating, including Mg, Al, Cs and Zr oxides. High resolution TEM is used to characterise the quality of both the nanowire core and the shell, and to monitor the thickness and the degree of crystallisation of the oxide coating. The interface between the nanowire core and the outer shell is investigated in order to understand the adhesion of the coating, and give valuable feedback for the synthesis process. Nanowire films are packaged into dye-sensitised solar cell prototypes; samples coated with ZrO2 and MgO show the largest enhancement in the photocurrent and open-circuit voltage and look very promising for further improvement. © 2010 IOP Publishing Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An experimental study was conducted on shock wave turbulent boundary layer interactions caused by a blunt swept fin-plate configuration at Mach numbers of 5.0, 7.8, 9.9 for a Reynolds number range of (1.0.similar to 4.7) x 10(7)/m. Detailed heat transfer and pressure distributions were measured at fin deflection angles of up to 30 degrees for a sweepback angle of 67.6 degrees. Surface oil flow patterns and liquid crystal thermograms as well as schlieren pictures of fin shock shape were taken. The study shows that the flow was separated at deflection of 10 degrees and secondary separation were detected at deflection of theta greater than or equal to 20 degrees. The heat transfer and pressure distributions on flat plate showed an extensive plateau region followed by a distinct dip and local peak close to the fin foot. Measurements of the plateau pressure and heat transfer were in good agreement with existing prediction methods, but pressure and heating peak measurements at M greater than or equal to 6 were significantly lower than predicted by the simple prediction techniques at lower Mach numbers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Shape Memory Alloy (SMA) can be easily deformed to a new shape by applying a small external load at low temperature, and then recovers its original configuration upon heating. This unique shape memory phenomenon has inspired many novel designs. SMA based heat engine is one among them. SMA heat engine is an environment-friendly alternative to extract mechanical energy from low-grade energies, for instance, warm wastewater, geothermal energy, solar thermal energy, etc. The aim of this paper is to present an applicable theoretical model for simulation of SMA-based heat engines. First, a micro-mechanical constitutive model is derived for SMAs. The volume fractions of austenite and martensite variants are chosen as internal variables to describe the evolution of microstructure in SMA upon phase transition. Subsequently, the energy equation is derived based on the first thermodynamic law and the previous SMA model. From Fourier’s law of heat conduction and Newton’s law of cooling, both differential and integral forms of energy conversion equation are obtained.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thermally induced recovery of nanoindents in a CUAINi single crystal shape memory alloy was studied by nanoindentation in conjunction with a heating stage. Nanoindents formed by a Berkovich indenter at room temperature were heated to 40, 70 and 100 degrees C. Partial recovery was observed for the nanoindents. The recovery ratio depended on the heating temperature. Indentation of CuAlNi can induce inelastic deformation via dislocation motion and a stress-induced matensitic transformation. The percentages of dislocation-induced plastic strain would affect the thermal deformation of CuAlNi, because the induced dislocations could stabilize stress-induced martensite plates even when the temperature above austenite finish temperature, A(f). When the applied indentation load is low (less than 10,000 mu N), the shape recovery strain is predominant, compared with the dislocation-induced plastic strain. Therefore, the degree of indent recovery in the depth direction, delta(D), is high (about 0.7-0.8 at 100 degrees C).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La presente investigación se realizó en sistemas agroforestales con Café Coffea arábiga L.)en el Municipio de Masatepe, Nicaragua, determinando el índice de área foliar, radiación solar no interceptada por especies forestales y concentración de magnesio en hojas de Café. Para determinar índice de área foliar se utilizó una metodología no destructiva y una destructiva; la medición no destructiva se basó en la técnica de fotografías hemisféricas para lo cual se utilizó una cámara Nikon Coolpix 4500 que permitió tomar fotografías de cuatro árboles de Samanea saman, Inga laurina, Simarouba glauca, Tabebuia rosea respectivamente. Porcada árbol se tomaron cuatro imágenes sobre lados opuestos del tronco (Norte, Sur, Este y Oeste), para el análisis de fotografías hemisféricas se empleó el software Gap Light Analyzer. Para contrastar la medición de índice de área foliar por método no destructivo (fotografías hemisféricas) se empleó un método destructivo basado en la recolección de 300 hojas, se tomó el peso húmedo del total de hojas de cada uno de los árboles en estudio. Del total de hojas de cada árbol se pesaron separadamente tres muestras; utilizando el planímetro LI-3000 se calculó en cada caso el área de la hoja. Una vez obtenida el área foliar de la hoja, las muestras se secaron en horno a 65° C, durante 72 h y promediadas para obtener biomasa del follaje. Dividiendo el área foliar de las muestras entre su peso seco se obtuvo el área foliar específica, posteriormente el promedio de área foliar específica de las muestras multiplicado por el peso seco total de hojas permitió calcular el área foliar del árbol. Finalmente, se obtuvo el índice de área foliar dividiendo área foliar entre el área de suelo asignada . La medición de la cantidad de radiación incidente sobre el follaje de las plantas de Café se realizó en la réplica II en CENECOOP en dos puntos de muestreo; el criterio de selección de los sitios se basó en la combinación de árboles ubicados diagonalmente y en la uniformidad de distancia entre las especies para la combinación T. rosea + S. glaucae I. laurina + S. saman. En esta réplica se realizaron análisis del contenido de magnesio en hojas de Café en las subparcelas 5, 6, 7, 8, 9, 10, 11 y 12 más dos muestras testigos en las subparcelas 13 y 14 a pleno sol. El índice de área foliar promedio para especies tropicales estimado por el método destructivo fue de 2,52 y por el método no destructivo fue de 0,85; debido a estas diferencias es necesario aplicar un factor de corrección o calibración al método no destructivo para validar ambos resultados. En la combinación I. laurina + S. saman se detectó un mayor paso de radiación solar al cafetal (29911,11lux) posiblemente debido a las características morfológicas del dosel. La concentración de magnesio más alta es de 2% la cual se encontró en las hojas de Café de la combinación T. rosea + S. glauca en nivel de insumo orgánico moderado.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La obtención del producto final del rubro café conlleva una serie de procesos, entre ellos está el beneficiado (húmedo y seco). El beneficiado seco es un proceso para reducir la humedad los frutos del cafeto de su estado café pergamino mojado obtenido del beneficiado húmedo, este se realiza en patio exponiendo los granos húmedos durante varios días a los rayos directos del sol, sobre una superficie de cemento o madera. Exponiendo el café a los efectos negativos del ambiente, reduciendo la calidad, elevando los costos, mayor uso de mano de obra y corriendo riesgos constantes de contaminación y a castigos impuestos por la acopiadora en el pesaje por merma de humedad. Como una propuesta a estos riesgos se evaluó el efecto del presecador solar tipo domo en el presecado de granos de café orgánico (Coffea arabica L.), en fincas de pequeños productores de las cooperativas San Isidro R.L Boaco y PROCOSER Nueva Segovia. En el ciclo 2010-2011. Se realizó en dos fases: primera, correspondió a una investigación no experimental donde se utilizo una encuesta semi-estructurada para determinar las características de los productores (datos del productor, datos de la finca, área de café, altura de la finca, variedades de café presentes y actividades que realizan en el beneficiado húmedo). Calidad de corte y prueba de rendimiento de las diferentes localidades seleccionadas. En la segunda, se estableció un experimento unifactorial, al comparar la tecnología (pre secador tipo domo). Las variables a evaluadas fueron: área y altura de la finca, variedades de café, actividades del beneficiado húmedo, temperatura, humedad relativa, peso del grano y rendimientos. Los resultados obtenidos fueron que hubo diferencias en algunas actividades del proceso de beneficiado húmedo entre los productores de los departamentos. La pérdida de humedad en el grano de café fue mayor en el volumen de 11.36 kg/m2 en ambas localidades igualmente la pérdida del peso del grano, los menores costos variables y mayores beneficios netos se los obtuvo el tratamiento de 22.72 kg / m2 fuera del presecador tradicional en el departamento de Boaco mientras que en el departamento de Nueva Segovia fue el de 11.36 kg/m2 dentro del presecador solar tipo domo.