980 resultados para Socket.io


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The sternal gland is considered the only source of trail pheromones in termites. The morphology of the sternal gland was investigated in workers of Coptotermes gestroi using transmission and scanning electron microscopy. The results showed a small bilobed gland at the anterior part of the fifth abdominal sternite. The cuticular surface of the sternal gland showed a V-shaped structure with two peg sensilla in elevated socket and various campaniform sensilla. Pores and cuticular scale-like protuberances also occur in the glandular area. The ultrastructure showed a gland composed of class I cells and two different types of class 3 cells distinguished by location, different size and electron-density of secretory vesicles. Small class 3 cells (type 1) of the anterior lobe are inserted among class I cells and have weakly electron-dense vesicles associated with mitochondria, glycogen and smooth endoplasmic reticulum. The class 3 cells (type 2) of posterior lobe showed many round electron-lucent vesicles of secretion, abundant free ribosomes and a well-developed Golgi apparatus. Each class 3 cell is connected to the cuticle by a cuticular duct constituted by the receiving canal and the conducting canal. The secretion of class I cells is stored in an inner subcuticular reservoir that is delimited by the microvilli of these cells. This inner reservoir is large and crossed by the campaniform sensilla and ducts of two types of class 3 cells that open outside of the insect body. An exterior reservoir also is present between the fourth and fifth sternite. The complex structure of the sternal gland suggests multicomponents for the trail pheromone in the worker of C gestroi. (c) 2005 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study aimed to compare trunk muscle co-activation pattern during exercises using an oscillatory pole. Twelve volunteers participated in this study, in which they performed three different exercises. EMG activity of internal oblique (IO), external oblique (EO), rectus abdominis (RA), multifidus (MU) and iliocostalis lumborum (IL) was collected. The EMG signals were analyzed in time domain (RMS) and muscles activation ratios were computed as follow: anterior-posterior (A/P=RA+EO+IO/MU+IL), MU/IL and OE/OI. The bilateral oscillation of the pole in frontal plane (exercise II) promoted a higher value of MU/IL ratio than unilateral oscillation of the pole in sagital plane (exercise III). Also, the bilateral oscillation of the pole in frontal plane (exercise II) and the unilateral oscillation of the pole in sagital plane (exercise III) caused higher values of the IO/EO than bilateral oscillation of the pole in transversal plane (exercise I). Thus, the exercises II and III required higher activation of trunk stabilizer muscles, being more indicate for training, which aims higher recruitment of these muscles in daily activities.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: Hand-held flexible poles which are brought into oscillation to cause alternating forces on trunk, are advocated as training devices that are supposed to solicit increased levels of stabilizing trunk muscle activity. The aim of this study was to verify this claim by comparing electromyographic (EMG) activity of trunk muscles during exercises performed with a flexible pole and a rigid pole.Methods: Twelve healthy females performed three different exercises with flexible and rigid poles. EMG activity of iliocostalis lumborum (IL), multifidus (MU), rectus abdominis (RA), external oblique (EO) and internal oblique (IO), and was continuously measured. The EMG signals were analyzed in time domain by calculation of the Root Mean Square (RMS) amplitudes over 250 ms windows. The mean RMS-values over time were normalized by the maximum RMS obtained for each muscle.Results: The IO showed a 72% greater EMG activity during the exercises performed with the flexible pole than with the rigid pole (p = 0.035). In exercises performed in standing, the IO was significantly more active than when sitting (p = 0.006).Conclusion: As intended, the cyclic forces induced by the oscillating pole did increase trunk muscle activation. However, the effect was limited and significant for the IO muscle only.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: Avaliar a regeneração óssea de alvéolos dentais de gatos após enxertia. MÉTODOS: Dezoito gatos adultos, distribuídos em três grupos de 6 animais cada, foram submetidos a extração do canino mandibular direito ou esquerdo. No grupo 1, controle, o alvéolo foi deixado vazio. No grupo 2, o alvéolo foi preenchido com osso esponjoso autógeno do osso ilíaco e no grupo 3, com raspa de osso cortical do osso ilíaco. Os animais foram submetidos à eutanásia 6 semanas após a cirurgia. RESULTADOS: Nas radiografias realizadas no pós-operatório imediato na projeção ventrodorsal observou-se uma área de radiolucência correspondente ao local da alveolectomia e extração dentária. Diminuição da radiolucência foi verificada nas radiografias realizadas seis semanas após a cirurgia. Nos cortes histológicos verificou-se a presença de trabéculas ósseas. A porcentagem de tecido ósseo esponjoso presente nos alvéolos dentais foi quantificada por exames histométricos. Não houve diferença estatisticamente significante entre os grupos (Teste de Kruskal-Wallis p > 0.05) (grupo 1: 52,54 ± 15,4; grupo 2: 50,51 ± 5,01; grupo 3: 51,85 ± 9,52). CONCLUSÃO: Os alvéolos dentais de gatos preenchidos com osso esponjoso autógeno ou raspa de osso cortical autógeno apresentaram regeneração óssea similar àquela observada no grupo controle, após um período de observação de seis semanas.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Accurate diagnosis and adequate treatment plan may constitute very complex tasks, particularly in tooth avulsion, because several variables are involved. In addition to the technical knowledge and clinical experience directed toward the quality of treatment, patient education may favorably influence the survival of replanted teeth. The aim of this study was to analyze the procedures used in the management of tooth avulsion by 100 dental surgeons (DSs). Thus, by means of a descriptive questionnaire, information was obtained about the profile of the professionals interviewed, procedures used in cases of tooth avulsion, and patient orientation and education. One hundred properly filled questionnaires were obtained. Descriptive statistics was used for the data, and the chi-squared statistics was employed (EPI-INFO 3.2 software). According to the results, this type of trauma is part of the routine of 15 DSs, although 71 have reported some experience with avulsed,teeth. Great deficiencies were found regarding root surface treatment and occlusal adjustment. Positive findings were related to socket treatment, adjunctive therapy, and patient education and orientation (extra-alveolar period, storage medium, manipulation of the avulsed tooth, replantation by the own patient). It was possible to conclude that 47.5% of the procedures reported by, 100 professionals interviewed are adequate, and patient education is favorable in 87.7% of cases, a fact that can positively interfere with the prognosis of tooth replantation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Blood constituents of Nelore, Hosltein and buffalo cows were determined during pregnancy, at the time of calving and at post-partum. It was verified that. 1. The pregnancy and post-partum periods had no influence in the erythrocyte values, but at calving the red blood cell counts and hemoglobin levels of Holstein and buffalo cows were lower than for Nelore cattle; 2. leukocyte counts were similar among groups; 3. total protein levels of Nelore cows were lower than Holstein and buffalo. The albumin levels were rite lowest at rite time of calving compared to late pregnancy; 4. glicose levels were lower ill buffalo cows during pregnancy as compared with Holstein cows. The glicemia of Nelore cows was lower as compared to Holstein cow's irt late pregnancy; 5. urea and creatinine levels were higher in buffalo cows than cattle. The urea and creatinine levels were greater in buffalo cows with maximum values at the post-partum and at the parturition, respectively; 6. bilirrubin levels were higher in bovine than buffalo cows; 7. aspartate aminotransferase activity was greater in buffalo cows and increased at the time of calving; 8. alkaline phosphatase activity was increased during pregnancy and decreased after the time of calving; 9. gammnglutamyltransferase activity,vas the highest for buffalo cows after calving; IO. calcium levels were the highest for Holstein cows at the post-partum and the phosphorus levels were higher in buffalo cows, which had the highest magnesium levels at the parturation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Several studies have demonstrated that caffeine improves endurance exercise performance but the mechanisms are not fully understood. Possibilities include increased free fatty acid (FFA) oxidation with consequent sparing of muscle glycogen as well as enhancement of neuromuscular function during exercise. The present study was designed to investigate the effects of caffeine on liver and muscle glycogen of 3-month old, male Wistar rats (250-300 g) exercising by swimming. Caffeine (5 mg/kg) dissolved in saline (CAF) or 0.9% sodium chloride (SAL) was administered by oral intubation (1 mu l/g) to fed rats 60 min before exercise. The rats (N = and-IO per group) swam bearing a load corresponding to 5% body weight for 30 or 60 min. FFA levels were significantly elevated to 0.475 +/- 0.10 mEq/l in CAF compared to 0.369 +/- 0.06 mEq/l in SAL rats at the beginning of exercise. During exercise, a significant difference in FFA levels between CAF and SAL rats was observed at 30 min (0.325 +/- 0.06 vs 0.274 +/- 0.05 mEq/l) but not at 60 min (0.424 +/- 0.13 vs 0.385 +/- 0.10 mEq/l). Blood glucose showed an increase due to caffeine only at the end of exercise (CAF = 142.1 +/- 27.4 and SAL = 120.2 +/- 12.9 mg/100 ml). No significant difference in liver or muscle glycogen was observed in CAF as compared to SAL rats, at rest or during exercise. Caffeine increased blood lactate only at the beginning of exercise (CAF = 2.13 +/- 0.2 and SAL = 1.78 +/- 0.2 mmol/l). These data indicate that caffeine (5 mg/kg) has no glycogen-sparing effect on rats exercising by swimming even though the FFA levels of CAF rats were significantly higher at the beginning of exercise.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The construction of a flow-through cell incorporating an array of gold microelectrodes is described and its application to flow injection analysis with amperometric detection is presented, Simple modification of almost any conventional integrated circuit chip, used as an inexpensive source of pre-assembled gold micro-wires, leads to the rapid and successful preparation of arrays of 8-48 elements, the polymeric encapsulation material from the top face of the chip is removed by abrasion until the gold micro-mires (used to interconnect the silicon circuit to the external contact pins of the chip) are disrupted and their transversal (elliptical) sections become exposed. Once polished, the flat and smooth top surface of the gold microelectrode-array chip (MEAC) is provided with a spacer and fitted under pressure against an acrylic block with the reference and auxiliary electrodes, to form the electrochemical (thin-layer) flow cell, while the contact pins are plugged into a standard IC socket, This design ensures autonomous electric contact with each electrode and allows fast dismantling for polishing or substitution, the performance of flow cells with MEACs was investigated utilizing the technique of reverse pulse amperometry without oxygen removal, A method was established for the determination of the copper concentration in sugar cane spirit, regulated by law for beverages, Samples from industrial producers and small-scale (alembic) brewers were compared, With a 24 MEAC, a detection limit of 30 mu g I-l of copper (4.7 x 10(-7) mol l(-1) of Cu-II for 100 mu l injections) was calculated, Routine operation was established at a frequency of 60-90 determinations per hour, Intercomparison with atomic absorption spectrometric determinations resulted in excellent agreement.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim: To evaluate the effect of implant length (6 mm vs. 11 mm) on osseointegration (bone-toimplant contact) of implants installed into sockets immediately after tooth extraction.Material and methods: In six Labrador dogs, the pulp tissue of the mesial roots of P-3(3) was removed and the root canals were filled. Flaps were elevated bilaterally, the premolars hemisectioned and the distal roots removed. Recipient sites were prepared in the distal alveolus and a 6 mm or an 11 mm long implant was installed at the test and control sites, respectively. Non-submerged healing was allowed. After 4 months of healing, block sections of the implant sites were obtained for histological processing and peri-implant tissue assessment.Results: No statistically significant differences were found between test and control sites both for hard and soft tissue parameters. The bone-to-implant contact evaluated at the apical region of the implants was similar as well. Although not statistically significant, the location of the top of the bony crest at the buccal aspect was more apical in relation to the implant shoulder at the test compared with the control sites (2.0 +/- 1.4 and 1.2 +/- 1.1 mm, respectively).Conclusions: Shorter implants (6 mm) present with equal osseointegration than do longer implants (11 mm).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AimTo compare the influence of autologous or deproteinized bovine bone mineral as grafting material on healing of buccal dehiscence defects at implants installed immediately into the maxillary second incisor extraction socket in dogs.Material and methodsIn the maxillary second incisor sockets of 12 Labrador dogs, implants were installed immediately following tooth extraction. A standardized buccal defect was created and autologous bone particles or deproteinized bovine bone mineral were used to fill the defects. A collagen membrane was placed to cover the graft material, and the flaps were sutured to fully submerge the experimental areas. Six animals were sacrificed after 2 months, and six after 4 months of healing. Ground sections were obtained for histological evaluation.ResultsAfter 2 months of healing, all implants were osseointegrated. All buccal dehiscence defects were completely filled after 2 months irrespective of the augmentation material (autologous bone or Bio-Oss (R)) applied. Bone-to-implant contact (BIC) on the denuded implant surfaces was within a normal range of 30-40%. However, the newly formed tissue at 2 months was partially resorbed (> 50% of the area measurements) after 4 months.ConclusionsApplying either autologous bone or deproteinized bovine bone mineral to dehiscences at implants installed immediately into extraction sockets resulted in high degree of regeneration of the defects with satisfactory BIC on the denuded implant surface.To cite this article:De Santis E, Botticelli D, Pantani F, Pereira FP, Beolchini M, Lang NP. Bone regeneration at implants placed into extraction sockets of maxillary incisors in dogs.Clin. Oral Impl. Res. 22, 2011; 430-437.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This article reports the case of a 12-year-old patient with tooth extrusion, pain, gingival bleeding, and localized periodontitis near the maxillary second premolar. Despite probing and radiographic examination, it was not possible to establish the etiology. Tooth extraction was indicated because of the severe tooth mobility and extrusion. Curettage of the tooth socket revealed a rubber separator. Preventive approaches are suggested to avoid iatrogenesis and legal problems. (Am J Orthod Dentofacial Orthop 2012; 142:402-5)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim To evaluate the soft tissue and the dimensional changes of the alveolar bony crest at sites where deproteinized bovine bone mineral (DBBM) particles, concomitantly with the placement of a collagen membrane, were used at implants installed into sockets immediately after tooth extraction. Material and methods The pulp tissue of the mesial roots of 3P3 was removed in six Labrador dogs, and the root canals were filled. Flaps were elevated bilaterally, the premolars hemi-sectioned, and the distal roots removed. Recipient sites were prepared in the distal alveolus, and implants were placed. At the test sites, DBBM particles were placed in the residual marginal defects concomitantly with the placement of a collagen membrane. No treatment augmentation was performed at the control sites. A non-submerged healing was allowed. Impressions were obtained at baseline and at the time of sacrifice performed 4 months after surgery. The cast models obtained were analyzed using an optical system to evaluate dimensional variations. Block sections of the implant sites were obtained for histological processing and soft tissue assessments. Results After 4 months of healing, no differences in soft tissue dimensions were found between the test and control sites based on the histological assessments. The location of the soft tissue at the buccal aspect was, however, more coronal at the test compared with the control sites (1.8 +/- 0.8 and 0.9 +/- 0.8 mm, respectively). At the three-dimensional evaluation, the margin of the soft tissues at the buccal aspect appeared to be located more apically and lingually. The vertical dislocation was 1 +/- 0.6 and 2.7 +/- 0.5 mm at the test and control sites, respectively. The area of the buccal shrinkage of the alveolar crest was significantly smaller at the test sites (5.9 +/- 2.4 mm2) compared with the control sites (11.5 +/- 1.7 mm2). Conclusion The use of DBBM particles concomitantly with the application of a collagen membrane used at implants placed into sockets immediately after tooth extraction contributed to the preservation of the alveolar process.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

ObjectivesTo evaluate the influence of implant size and configuration on osseointegration in implants immediately placed into extraction sockets.Material and methodsImplants were installed immediately into extraction sockets in the mandibles of six Labrador dogs. In the control sites, cylindrical transmucosal implants (3.3 mm diameter) were installed, while in the test sites, larger and conical (root formed, 5 mm diameter) implants were installed. After 4 months of healing, the resorptive patterns of the alveolar crest were evaluated histomorphometrically.ResultsWith one exception, all implants were integrated in mineralized bone, mainly composed of mature lamellar bone. The alveolar crest underwent resorption at the control as well as at the test implants. This resorption was more pronounced at the buccal aspects and significantly greater at the test (2.7 +/- 0.4 mm) than at the control implants (1.5 +/- 0.6 mm). However, the control implants were associated with residual defects that were deeper at the lingual than at the buccal aspects, while these defects were virtually absent at test implants.ConclusionsThe installment of root formed wide implants immediately into extraction sockets will not prevent the resorption of the alveolar crest. In contrast, this resorption is more marked both at the buccal and lingual aspects of root formed wide than at standard cylindrical implants.To cite this article:Caneva M, Salata LA, de Souza SS, Bressan E, Botticelli D, Lang NP. Hard tissue formation adjacent to implants of various size and configuration immediately placed into extraction sockets: an experimental study in dogs.Clin. Oral Impl. Res. 21, 2010; 885-895.doi: 10.1111/j.1600-0501.2010.01931.x.