986 resultados para Single-platform Trucount Assay


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Trabalho apresentado no âmbito do Mestrado em Engenharia Informática, como requisito parcial para obtenção do grau de Mestre em Engenharia Informática

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to define an accurate assay for anti-adenovirus antibody detection, a recently developed ELISA was compared with IFA and CF. On 58 sera, the ELISA was more sensitive than both CF and IFA, which showed relative sensitivities of 63% and 94%, respectively. It was not possible to determine the exact specificity of the tests because of the lack of a gold standard. Furthermore, the ELISA was used to define the prevalence of adenovirus antibodies in 116 infants between 1 and 24 months old (mean 7.28). The data showed that maternal antibodies waned by the age of 5 to 6 months and that more than 80% of the children had been infected by adenoviruses by the age of 10 months.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The mutagenic activities of 16 anti-parasite drugs were screened by the Simultest in both qualitative (spot test) and quantitative (plate incorporation) assays with a Salmonella typhimurium pool composed by the indicator strains TA97, TA 98, TA100 and TA102. Four anti Chagas' disease drugs (nifurtimox, benznidazole, CL 64,855, and MK 436) and two anti-amebae drugs (metronidazole and tinidazole) gave positive results in qualitative tests and incorporation of rat liver microsomes did not alter the results. Comparative dose response curves of the mutagenic activities of CL 64,855, metronidazole and benznidazole obtained by the simultest and by individual Salmonella indicator strains demonstrated that both approachs have similar sensitivities. The results corroborate the validity of the Simultest, as a simplified, fast and economic version of the Ames test in preliminary screening of potential mutagenic drugs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper reports on a first step towards the implementation of a framework for remote experimentation of electric machines ? the RemoteLabs platform. This project was focused on the development of two main modules: the user Web-based and the electric machines interfaces. The Web application provides the user with a front-end and interacts with the back-end ? the user and experiment persistent data. The electric machines interface is implemented as a distributed client server application where the clients, launched by the Web application, interact with the server modules located in platforms physically connected the electric machines drives. Users can register and authenticate, schedule, specify and run experiments and obtain results in the form of CSV, XML and PDF files. These functionalities were successfully tested with real data, but still without including the electric machines. This inclusion is part of another project scheduled to start soon.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An enzyme-linked immunosorbent assay (ELISA) for measles antibodies was compared with Plaque Neutralization (PRN), Haemagglutination inhibition (HI) and Fluorescent antibody (IFA) tests in 181 sera from vaccinated children and umbilical cord. Of 179 positive samples by the sensitive PRN, only two, with titers of 8, were negative by ELISA (copositivity of 98.9%). IFA and HI presented, respectively, copo-sitivities of 93.3% and 82.7%. The ELISA presented a high sensitivity as well as a good reproducibility and represents an alternative for the time consuming PRN for detection of low measles antibodies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Trabalho de Projeto apresentado ao Instituto Superior de Contabilidade e Administração do Porto para a obtenção do grau de Mestre em Marketing Digital, sob orientação do Mestre Paulo Gonçalves

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Diagnostic performance indexes of sensitivity, specificity, positive predictive value and efficiency were determined for dot-ELISA and IgG-ELISA tests in 340 leishmaniasis sera. Sensitivity of the dot-ELISA was significantly lower than IgG-ELISA's; the two tests had indexes of specificity and positive predictive value of the same magnitude. Seventy-eight sera gave a negative dot-ELISA test result and a positive IgG-ELISA test result. When sera were classified according to different criteria as how to interpret this diversity, the kappa statistic did not corroborate the classification indicating that the two tests display a substantial strength of agreement. The results presented indicate that performance indexes accrued in a survey where variables arc well known may be extrapolated to other population studies if the disease presents itself as highly prevalent (due to a selection bias or not) and may be expected to discriminate a disease status among test positives.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have evaluated the sensitivity of the classical blood subinoculation method, modified through cyclophosphamide treatment of transferred mice, for the detection of occult parasitaemias in Trypanosoma cruzi chronically infected mice. Besides its simplicity, the method was shown to be highly sensitive for both the "chronic" phase parasites (99% of chronic cases were shown to harbour occult parasitaemias) and for the acute phase parasites (T. cruzi could be detected in 53.8% of animals transferred with one Y strain parasite and in 20% of animals transferred with one CL strain parasite). Using acute phase bloodforms, the assay proved to be more sensitive than conventional subinoculation when dealing with the CL, but not the Y strain of the parasite. With the help of this parasite detection tool, we have studied during a one year period, the evolution of subpatent parasitaemias in a group of mice which survived through chemotherapy from lethal acute phase of T. cruzi infection. Cyclophosphamide transfer assay revealed occult parasitaemias in 100% of the chronic animals, nevertheless, continuous and discontinuous patterns of positivity were observed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The dot-enzyme-linked immunosorbent assay (dot-ELISA) was standardized using somatic (S) and excretory-secretory (ES) antigens of Toxocara-canis for the detection of specific antibodies in 22 serum samples from children aged 1 to 15 years, with clinical signs of toxocariasis. Fourteen serum samples from apparently normal individuals and 28 sera from patients with other pathologies were used as controls. All samples were used before and after absorption with Ascaris suum extract. When the results were evaluated in comparison with ELISA, the two tests were found to have similar sensitivity, but dot-ELISA was found to be more specific in the presence of the two antigens studied. Dot-ELISA proved to be effective for the diagnosis of human toxocariasis, presenting advantages in terms of yield, stability, time and ease of execution and low cost.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mushroom strains contain complex nutritional biomolecules with a wide spectrum of therapeutic and prophylactic properties. Among these compounds, β-d-glucans play an important role in immuno-modulating and anti-tumor activities. The present work involves a novel colorimetric assay method for β-1,3-d-glucans with a triple helix tertiary structure by using Congo red. The specific interaction that occurs between Congo red and β-1,3-d-glucan was detected by bathochromic shift from 488 to 516 nm (> 20 nm) in UV–Vis spectrophotometer. A micro- and high throughput method based on a 96-well microtiter plate was devised which presents several advantages over the published methods since it requires only 1.51 μg of polysaccharides in samples, greater sensitivity, speed, assay of many samples and very cheap. β-d-Glucans of several mushrooms (i.e., Coriolus versicolor, Ganoderma lucidum, Pleurotus ostreatus, Ganoderma carnosum, Hericium erinaceus, Lentinula edodes, Inonotus obliquus, Auricularia auricular, Polyporus umbellatus, Cordyseps sinensis, Agaricus blazei, Poria cocos) were isolated by using a sequence of several extractions with cold and boiling water, acidic and alkaline conditions and quantified by this microtiter plate method. FTIR spectroscopy was used to study the structural features of β-1,3-d-glucans in these mushroom samples as well as the specific interaction of these polysaccharides with Congo red. The effect of NaOH on triple helix conformation of β-1,3-d-glucans was investigated in several mushroom species.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Basidiomycete strains synthesize several types of beta-D-glucans, which play a major role in the medicinal properties of mushrooms. Therefore, the specific quantification of these beta-D-glucans in mushroom strains is of great biochemical importance. Because published assay methods for these beta-D-glucans present some disadvantages, a novel colorimetric assay method for beta-D-glucan with alcian blue dye was developed. The complex formation was detected by following the decrease in absorbance in the range of 620 nm and by hypsochromic shift from 620 to 606 nm (similar to 14 nm) in UV-Vis spectrophotometer. Analysis of variance was used for optimization of the slope of the calibration curve by using the assay mixture containing 0.017% (w/v) alcian blue in 2% (v/v) acetic acid at pH 3.0. The high-throughput colorimetric assay method on microtiter plates was used for quantification of beta-D-glucans in the range of 0-0.8 mu g, with a slope of 44.15 x 10(-2) and a limit of detection of 0.017 mu g/well. Recovery experiments were carried out by using a sample of Hericium erinaceus, which exhibited a recovery of 95.8% for beta-1,3-D-glucan. The present assay method exhibited a 10-fold higher sensitivity and a 59-fold lower limit of detection compared with the published method with congo red beta-D-glucans of several mushrooms strains were isolated from fruiting bodies and mycelia, and they were quantified by this assay method. This assay method is fast, specific, simple, and it can be used to quantify beta-D-glucans from other biological sources. (C) 2015 American Institute of Chemical Engineers

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An Enzyme-linked immunosorbent assay ELISA was evaluated for the detection of IgA antibodies in the human leptospirosis. The assay proved to be sensitive and specific when compared with the ELISA-IgM, in the examinated serum samples. The results found suggest that IgA antibodies became positive later in leptospirosis, and will can be an evolutive indicator in the development of the disease

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An experimental and numerical investigation into the shear strength behaviour of adhesive single lap joints (SLJs) was carried out in order to understand the effect of temperature on the joint strength. The adherend material used for the experimental tests was an aluminium alloy in the form of thin sheets, and the adhesive used was a high-strength high temperature epoxy. Tensile tests as a function of temperature were performed and numerical predictions based on the use of a bilinear cohesive damage model were obtained. It is shown that at temperatures below Tg, the lap shear strength of SLJs increased, while at temperatures above Tg, a drastic drop in the lap shear strength was observed. Comparison between the experimental and numerical maximum loads representing the strength of the joints shows a reasonably good agreement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The most common techniques for stress analysis/strength prediction of adhesive joints involve analytical or numerical methods such as the Finite Element Method (FEM). However, the Boundary Element Method (BEM) is an alternative numerical technique that has been successfully applied for the solution of a wide variety of engineering problems. This work evaluates the applicability of the boundary elem ent code BEASY as a design tool to analyze adhesive joints. The linearity of peak shear and peel stresses with the applied displacement is studied and compared between BEASY and the analytical model of Frostig et al., considering a bonded single-lap joint under tensile loading. The BEM results are also compared with FEM in terms of stress distributions. To evaluate the mesh convergence of BEASY, the influence of the mesh refinement on peak shear and peel stress distributions is assessed. Joint stress predictions are carried out numerically in BEASY and ABAQUS®, and analytically by the models of Volkersen, Goland, and Reissner and Frostig et al. The failure loads for each model are compared with experimental results. The preparation, processing, and mesh creation times are compared for all models. BEASY results presented a good agreement with the conventional methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Glucose monitoring in vivo is a crucial issue for gaining new understanding of diabetes. Glucose binding protein (GBP) fused to two fluorescent indicator proteins (FLIP) was used in the present study such as FLIP-glu- 3.2 mM. Recombinant Escherichia coli whole-cells containing genetically encoded nanosensors as well as cell-free extracts were immobilized either on inner epidermis of onion bulb scale or on 96-well microtiter plates in the presence of glutaraldehyde. Glucose monitoring was carried out by Förster Resonance Energy Transfer (FRET) analysis due the cyano and yellow fluorescent proteins (ECFP and EYFP) immobilized in both these supports. The recovery of these immobilized FLIP nanosensors compared with the free whole-cells and cell-free extract was in the range of 50–90%. Moreover, the data revealed that these FLIP nanosensors can be immobilized in such solid supports with retention of their biological activity. Glucose assay was devised by FRET analysis by using these nanosensors in real samples which detected glucose in the linear range of 0–24 mM with a limit of detection of 0.11 mM glucose. On the other hand, storage and operational stability studies revealed that they are very stable and can be re-used several times (i.e. at least 20 times) without any significant loss of FRET signal. To author's knowledge, this is the first report on the use of such immobilization supports for whole-cells and cell-free extract containing FLIP nanosensor for glucose assay. On the other hand, this is a novel and cheap high throughput method for glucose assay.