929 resultados para Single Phase Grid Connected Inverter
Resumo:
ResumoThe main idea of this work is based on the analysis of the electric torque through the acting of the PS in the power system, provided of a control for the compensation degree (PSC). A linear model of the single machine-infinite bus system is used with a PS installed (SMIB/PS system). The variable that represents the presence of PS in the net is associated to the phase displacement introduced in the terminal voltage of the synchronous machine by PS. For the input signals of the PSC are evaluated variations of the angular speed of the rotor, the current magnitude and the active power through the line where the PS is located. The simulations are accomplished to analyze the influence of the PS in the torque formation (synchronizing and damping), of the SMIB/PS system. The analysis are developed in the time and frequency domain.
Resumo:
This paper discusses the dynamic behaviour of a nonlinear two degree-of-freedom system consisting of a harmonically excited linear oscillator weakly connected to a nonlinear attachment that behaves as a hardening Duffing oscillator. A system which behaves in this way could be a shaker (linear system) driving a nonlinear isolator. The mass of the nonlinear system is taken to be much less than that in the linear system and thus the nonlinear system has little effect on the dynamics of the linear system. Of particular interest is the situation when the linear natural frequency of the nonlinear system is less than the natural frequency of the linear system such that the frequency response curve of the nonlinear system bends to higher frequencies and thus interacts with the resonance frequency of the linear system. It is shown that for some values of the system parameters a complicated frequency response curve for the nonlinear system can occur; closed detached curves can appear as a part of the overall amplitude-frequency response. The reason why these detached curves appear is presented and approximate analytical expressions for the jump-up and jump-down frequencies of the system under investigation are given.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Engenharia Mecânica - FEG
Resumo:
Here we compare the management and survival outcomes of chronic myeloid leukemia (CML) patients who had early or late imatinib mesylate (IM) therapy. The cytogenetic and molecular responses of 189 CML patients were analyzed. Of this group, 121 patients were classified as the early chronic phase (ECP) group and started IM within 12 months of diagnosis. The other 68 patients were classified as the late chronic phase (LCP) group who had been treated with interferon (IFN)-alpha-2 and crossed over to IM more than 12 months after diagnosis. The overall rates of complete cytogenetic response (CCyR) and major molecular response (MMR) at last follow-up were 83.6 and 78.1% in the ECP and LCP groups, respectively. The CCyR rates were 89.3 (for ECP patients) versus 73.5% (for LCP patients; p < 0.0001). At last follow-up, 82.4% ECP and 64.2% LCP patients had achieved an MMR (p < 0.0001). No significant differences were noted between the two groups with regard to survival outcomes. Our experience reveals that IM is an effective rescue therapy in most CML LCP patients who are intolerant or in whom IFN-alpha therapy fails. Such therapeutic options should be considered in LCP patients, particularly in countries where IM may not be available. Copyright (C) 2012 S. Karger AG, Basel
Resumo:
Research work carried out in focusing a novel multiphase-multilevel ac motor drive system much suitable for low-voltage high-current power applications. In specific, six-phase asymmetrical induction motor with open-end stator winding configuration, fed from four standard two-level three-phase voltage source inverters (VSIs). Proposed synchronous reference frame control algorithm shares the total dc source power among the 4 VSIs in each switching cycle with three degree of freedom. Precisely, first degree of freedom concerns with the current sharing between two three-phase stator windings. Based on modified multilevel space vector pulse width modulation shares the voltage between each single VSIs of two three-phase stator windings with second and third degree of freedom, having proper multilevel output waveforms. Complete model of whole ac motor drive based on three-phase space vector decomposition approach was developed in PLECS - numerical simulation software working in MATLAB environment. Proposed synchronous reference control algorithm was framed in MATLAB with modified multilevel space vector pulse width modulator. The effectiveness of the entire ac motor drives system was tested. Simulation results are given in detail to show symmetrical and asymmetrical, power sharing conditions. Furthermore, the three degree of freedom are exploited to investigate fault tolerant capabilities in post-fault conditions. Complete set of simulation results are provided when one, two and three VSIs are faulty. Hardware prototype model of quad-inverter was implemented with two passive three-phase open-winding loads using two TMS320F2812 DSP controllers. Developed McBSP (multi-channel buffered serial port) communication algorithm able to control the four VSIs for PWM communication and synchronization. Open-loop control scheme based on inverse three-phase decomposition approach was developed to control entire quad-inverter configuration and tested with balanced and unbalanced operating conditions with simplified PWM techniques. Both simulation and experimental results are always in good agreement with theoretical developments.
Resumo:
pegylated liposomal doxorubicin (PLD) and bevacizumab are active agents in the treatment of metastatic breast cancer (MBC). We carried out a multicenter, single-arm phase II trial to evaluate the toxicity and efficacy of PLD and bevacizumab as first-line treatment in MBC patients.
Resumo:
INTRODUCTION Small-cell lung cancer (SCLC) is a highly vascularized tumor. ASA404 is a tumor vascular disrupting agent. This is the first trial to report the effects of combining chemotherapy with ASA404 in SCLC. METHODS Patients with untreated metastatic SCLC were treated with carboplatin (area under curve, 6) plus paclitaxel (175 mg/m(2)) plus ASA404 (1800 mg/m(2)) on day 1 every 21 days for up to 6 cycles. The primary endpoint was the progression-free survival (PFS) rate at 24 weeks. RESULTS Median age was 61 years; 53% were women, 41% had weight loss; and 96% had a performance status of 0-1. Twelve patients completed all 6 cycles, and most adverse events were related to chemotherapy. Median PFS and time to progression were 7.0 months (95% CI, 5.7-9.4 months) and 7.5 months (95% CI, 5.7-9.4 months), respectively. The progression-free survival (PFS) rate at 24 weeks was 41% (95% CI, 18%-65%). The overall response rate was 94%. The median overall survival time was 14.2 months (95% CI, 8.2-16.0 months) and 1-year survival was 57%. The median follow-up time was 17.7 months. Due to negative results with ASA404 in non-small-cell lung cancer trials, the trial was stopped prematurely after 17 of 56 planned patients were being accrued. CONCLUSIONS This is the first report of a clinical trial with a vascular disrupting agent in SCLC. No unexpected toxicity was observed. PFS was not prolonged with carboplatin and paclitaxel plus ASA404.
Resumo:
The structural modifications upon heating of pentagonite, Ca(VO)(Si4O10)·4H2O (space group Ccm21, a=10.3708(2), b=14.0643(2), c=8.97810(10) Å, V=1309.53(3) Å3) were investigated by in situ temperature dependent single-crystal X-ray structure refinements. Diffraction data of a sample from Poona district (India) have been measured in steps of 25 up to 250 °C and in steps of 50 °C between 250 and 400 °C. Pentagonite has a porous framework structure made up by layers of silicate tetrahedra connected by V4+O5 square pyramids. Ca and H2O molecules are extraframework occupants. Room temperature diffraction data allowed refinement of H positions. The hydrogen-bond system links the extraframework occupants to the silicate layers and also interconnects the H2O molecules located inside the channels. Ca is seven-fold coordinated forming four bonds to O of the tetrahedral framework and three bonds to extraframework H2O. The H2O molecule at O9 showing a high displacement parameter is not bonded to Ca. The dehydration in pentagonite proceeds in three steps. At 100 °C the H2O molecule at O8 was released while O9 moved towards Ca. As a consequence the displacement parameter of H2O at O9 halved compared to that at room temperature. The unit-cell volume decreased to 1287.33(3) Å3 leading to a formula with 3H2O per formula unit (pfu). Ca remained seven-fold coordinated. At 175 °C Ca(VO)(Si4O10)·3H2O transformed into a new phase with 1H2O molecule pfu characterized by doubling of the c axis and the monoclinic space group Pn. Severe bending of specific TOT angles led to contraction of the porous three-dimensional framework. In addition, H2O at O9 was expelled while H2O at O7 approached a position in the center of the channel. The normalized volume decreased to 1069.44(9) Å3. The Ca coordination reduced from seven- to six-fold. At 225 °C a new anhydrous phase with space group Pna21 but without doubling of c had formed. Release of H2O at O7 caused additional contraction of TOT angles and volume reduction (V=1036.31(9) Å3). Ca adopted five-fold coordination. During heating excursion up to 400 °C this anhydrous phase remained preserved. Between room temperature and 225 °C the unit-cell volume decreased by 21% due to dehydration. The dehydration steps compare well with the thermo-gravimetric data reported in the literature.
Resumo:
Temperature dependent single-crystal X-ray data were collected on amicite K4Na4(Al8Si8O32)·11H2O from Kola Peninsula (Russia) in steps of 25 °C from room temperature to 175 °C and of 50 °C up to 425 °C. At room temperature amicite has space group I2 with a = 10.2112(1), b = 10.4154(1), c = 9.8802(1) Å, β = 88.458(1)°, V = 1050.416(18) Å3. Its crystal structure is based on a Si–Al ordered tetrahedral framework of the GIS type with two systems of eight-membered channels running along the a and c axes. Extraframework K and Na cations are ordered at two fully occupied sites. Above 75 °C amicite was found to partly dehydrate into two separate but coherently intergrown phases, both of space group I2/a, one K-rich ∼K8(Al8Si8O32) ·4H2O (at 75 °C: a = 10.038(2), b = 9.6805(19), c = 9.843(2) Å, β = 89.93(3)°, V = 956.5(3) Å3) and the other Na-rich ∼Na8(Al8Si8O32)·2H2O (at 75 °C: a = 9.759(2), b = 8.9078(18), c = 9.5270(19) Å, β = 89.98(3)°, V = 828.2(3) Å3). Upon further heating above 75 °C the Na- and K-phases lost remaining H2O with only minor influence on the framework structure and became anhydrous at 175 °C and 375 °C, respectively. The two anhydrous phases persisted up to 425 °C. Backscattered electron images of a heated crystal displayed lamellar intergrowth of the K- and Na-rich phases. Exposed to ambient humid conditions K- and Na-rich phases rehydrated and conjoined to the original one phase I2 structure.
Computer model simulation of alveolar phase III slopes: Implications for tidal single-breath washout
Resumo:
BACKGROUND Buruli ulcer (BU) is a necrotizing skin disease most prevalent among West African children. The causative organism, Mycobacterium ulcerans, is sensitive to temperatures above 37°C. We investigated the safety and efficacy of a local heat application device based on phase change material. METHODS In a phase II open label single center noncomparative clinical trial (ISRCTN 72102977) under GCP standards in Cameroon, laboratory confirmed BU patients received up to 8 weeks of heat treatment. We assessed efficacy based on the endpoints 'absence of clinical BU specific features' or 'wound closure' within 6 months ("primary cure"), and 'absence of clinical recurrence within 24 month' ("definite cure"). RESULTS Of 53 patients 51 (96%) had ulcerative disease. 62% were classified as World Health Organization category II, 19% each as category I and III. The average lesion size was 45 cm(2). Within 6 months after completion of heat treatment 92.4% (49 of 53, 95% confidence interval [CI], 81.8% to 98.0%) achieved cure of their primary lesion. At 24 months follow-up 83.7% (41 of 49, 95% CI, 70.3% to 92.7%) of patients with primary cure remained free of recurrence. Heat treatment was well tolerated; adverse effects were occasional mild local skin reactions. CONCLUSIONS Local thermotherapy is a highly effective, simple, cheap and safe treatment for M. ulcerans disease. It has in particular potential as home-based remedy for BU suspicious lesions at community level where laboratory confirmation is not available. CLINICAL TRIALS REGISTRATION ISRCT 72102977.
Resumo:
PURPOSE Rituximab maintenance therapy has been shown to improve progression-free survival in patients with follicular lymphoma; however, the optimal duration of maintenance treatment remains unknown. PATIENTS AND METHODS Two hundred seventy patients with untreated, relapsed, stable, or chemotherapy-resistant follicular lymphoma were treated with four doses of rituximab monotherapy in weekly intervals (375 mg/m(2)). Patients achieving at least a partial response were randomly assigned to receive maintenance therapy with one infusion of rituximab every 2 months, either on a short-term schedule (four administrations) or a long-term schedule (maximum of 5 years or until disease progression or unacceptable toxicity). The primary end point was event-free survival (EFS). Progression-free survival, overall survival (OS), and toxicity were secondary end points. Comparisons between the two arms were performed using the log-rank test for survival end points. RESULTS One hundred sixty-five patients were randomly assigned to the short-term (n = 82) or long-term (n = 83) maintenance arms. Because of the low event rate, the final analysis was performed after 95 events had occurred, which was before the targeted event number of 99 had been reached. At a median follow-up period of 6.4 years, the median EFS was 3.4 years (95% CI, 2.1 to 5.3) in the short-term arm and 5.3 years (95% CI, 3.5 to not available) in the long-term arm (P = .14). Patients in the long-term arm experienced more adverse effects than did those in the short-term arm, with 76% v 50% of patients with at least one adverse event (P < .001), five versus one patient with grade 3 and 4 infections, and three versus zero patients discontinuing treatment because of unacceptable toxicity, respectively. There was no difference in OS between the two groups. CONCLUSION Long-term rituximab maintenance therapy does not improve EFS, which was the primary end point of this trial, or OS, and was associated with increased toxicity.
Resumo:
An EMI filter for a three-phase buck-type medium power pulse-width modulation rectifier is designed. This filter considers differential mode noise and complies with MIL-STD- 461E for the frequency range of 10kHz to 10MHz. In industrial applications, the frequency range of the standard starts at 150kHz and the designer typically uses a switching frequency of 28kHz because the fifth harmonic is out of the range. This approach is not valid for aircraft applications. In order to design the switching frequency in aircraft applications, the power losses in the semiconductors and the weight of the reactive components should be considered. The proposed design is based on a harmonic analysis of the rectifier input current and an analytical study of the input filter. The classical industrial design does not consider the inductive effect in the filter design because the grid frequency is 50/60Hz. However, in the aircraft applications, the grid frequency is 400Hz and the inductance cannot be neglected. The proposed design considers the inductance and the capacitance effect of the filter in order to obtain unitary power factor at full power. In the optimization process, several filters are designed for different switching frequencies of the converter. In addition, designs from single to five stages are considered. The power losses of the converter plus the EMI filter are estimated at these switching frequencies. Considering overall losses and minimal filter volume, the optimal switching frequency is selected