943 resultados para Scientific workflow


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Vertical profiles of stratospheric water vapour measured by the Michelson Interferometer for Passive Atmospheric Sounding (MIPAS) with the full resolution mode between September 2002 and March 2004 and retrieved with the IMK/IAA scientific retrieval processor were compared to a number of independent measurements in order to estimate the bias and to validate the existing precision estimates of the MIPAS data. The estimated precision for MIPAS is 5 to 10% in the stratosphere, depending on altitude, latitude, and season. The independent instruments were: the Halogen Occultation Experiment (HALOE), the Atmospheric Chemistry Experiment Fourier Transform Spectrometer (ACE-FTS), the Improved Limb Atmospheric Spectrometer-II (ILAS-II), the Polar Ozone and Aerosol Measurement (POAM III) instrument, the Middle Atmospheric Water Vapour Radiometer (MIAWARA), the Michelson Interferometer for Passive Atmospheric Sounding, balloon-borne version (MIPAS-B), the Airborne Microwave Stratospheric Observing System (AMSOS), the Fluorescent Stratospheric Hygrometer for Balloon (FLASH-B), the NOAA frostpoint hygrometer, and the Fast In Situ Hygrometer (FISH). For the in-situ measurements and the ground based, air- and balloon borne remote sensing instruments, the measurements are restricted to central and northern Europe. The comparisons to satellite-borne instruments are predominantly at mid- to high latitudes on both hemispheres. In the stratosphere there is no clear indication of a bias in MIPAS data, because the independent measurements in some cases are drier and in some cases are moister than the MIPAS measurements. Compared to the infrared measurements of MIPAS, measurements in the ultraviolet and visible have a tendency to be high, whereas microwave measurements have a tendency to be low. The results of χ2-based precision validation are somewhat controversial among the comparison estimates. However, for comparison instruments whose error budget also includes errors due to uncertainties in spectrally interfering species and where good coincidences were found, the χ2 values found are in the expected range or even below. This suggests that there is no evidence of systematically underestimated MIPAS random errors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study examines the question of whether the journal ranking VHB-JOURQUAL 2 can be considered as a good measure for the construct “scientific quality”. Various rankings in business research provide the database for the analysis. The correlations between theses rankings are used to assess the validity of VHB-JOURQUAL 2 along various validity criteria. The correlations with rankings that measure the same construct based on different methods show that VHB-JOURQUAL 2 has acceptable, but moderate convergent validity. The validity varies considerably across disciplines, showing that the heterogeneity of business administration is not sufficiently represented by this overall ranking. The variability is related to the variation in members per discipline represented by the German Association for Business Research. Furthermore, the measure shows a weak correlation with acceptance rates as an indicator of nomological validity in some disciplines.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Utilizing advanced information technology, Intensive Care Unit (ICU) remote monitoring allows highly trained specialists to oversee a large number of patients at multiple sites on a continuous basis. In the current research, we conducted a time-motion study of registered nurses’ work in an ICU remote monitoring facility. Data were collected on seven nurses through 40 hours of observation. The results showed that nurses’ essential tasks were centered on three themes: monitoring patients, maintaining patients’ health records, and managing technology use. In monitoring patients, nurses spent 52% of the time assimilating information embedded in a clinical information system and 15% on monitoring live vitals. System-generated alerts frequently interrupted nurses in their task performance and redirected them to manage suddenly appearing events. These findings provide insight into nurses’ workflow in a new, technology-driven critical care setting and have important implications for system design, work engineering, and personnel selection and training.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An understanding of interruptions in healthcare is important for the design, implementation, and evaluation of health information systems and for the management of clinical workflow and medical errors. The purpose of this study is to identify and classify the types of interruptions experienced by Emergency Department(ED) nurses working in a Level One Trauma Center. This was an observational field study of Registered Nurses (RNs) employed in a Level One Trauma Center using the shadowing method. Results of the study indicate that nurses were both recipients and initiators of interruptions. Telephones, pagers, and face-to-face conversations were the most common sources of interruptions. Unlike other industries, the healthcare community has not systematically studied interruptions in clinical settings to determine and weigh the necessity of the interruption against their sometimes negative results such as medical errors, decreased efficiency, and increased costs. Our study presented here is an initial step to understand the nature, causes, and effects of interruptions, thereby improving both the quality of healthcare and patient safety. We developed an ethnographic data collection technique and a data coding method for the capturing and analysis of interruptions. The interruption data we collected are systematic, comprehensive, and close to exhaustive. They confirmed the findings from earlier studies by other researchers that interruptions are frequent events in critical care and other healthcare settings. We are currently using these data to analyze the workflow dynamics of ED clinicians, to identify the bottlenecks of information flow, and to develop interventions to improve the efficiency of emergency care through the management of interruptions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To identify and describe unintended adverse consequences related to clinical workflow when implementing or using computerized provider order entry (CPOE) systems. METHODS: We analyzed qualitative data from field observations and formal interviews gathered over a three-year period at five hospitals in three organizations. Five multidisciplinary researchers worked together to identify themes related to the impacts of CPOE systems on clinical workflow. RESULTS: CPOE systems can affect clinical work by 1) introducing or exposing human/computer interaction problems, 2) altering the pace, sequencing, and dynamics of clinical activities, 3) providing only partial support for the work activities of all types of clinical personnel, 4) reducing clinical situation awareness, and 5) poorly reflecting organizational policy and procedure. CONCLUSIONS: As CPOE systems evolve, those involved must take care to mitigate the many unintended adverse effects these systems have on clinical workflow. Workflow issues resulting from CPOE can be mitigated by iteratively altering both clinical workflow and the CPOE system until a satisfactory fit is achieved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An understanding of interruptions in healthcare is important for the design, implementation, and evaluation of health information systems and for the management of clinical workflow and medical errors. The purpose of this study is to identify and classify the types of interruptions experienced by ED nurses working in a Level One Trauma Center. This was an observational field study of Registered Nurses employed in a Level One Trauma Center using the shadowing method. Results of the study indicate that nurses were both recipients and initiators of interruptions. Telephone, pagers, and face-to-face conversations were the most common sources of interruptions. Unlike other industries, the outcomes caused by interruptions resulting in medical errors, decreased efficiency and increased cost have not been systematically studied in healthcare. Our study presented here is an initial step to understand the nature, causes, and effects of interruptions, and to develop interventions to manage interruptions to improve healthcare quality and patient safety. We developed an ethnographic data collection technique and a data coding method for the capturing and analysis of interruptions. The interruption data we collected are systematic, comprehensive, and close to exhaustive. They confirmed the findings from early studies by other researchers that interruptions are frequent events in critical care and other healthcare settings. We are currently using these data to analyze the workflow dynamics of ED clinicians, identify the bottlenecks of information flow, and develop interventions to improve the efficiency of emergency care through the management of interruptions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

From its original formulation in 1990 the International Trans-Antarctic Scientific Expedition (ITASE) has had as its primary aim the collection and interpretation of a continent-wide array of environmental parameters assembled through the coordinated efforts of scientists from several nations. ITASE offers the ground-based opportunities of traditional-style traverse travel coupled with the modern technology of CPS, crevasse detecting radar, satellite communications and multidisciplinary research. By operating predominantly in the mode of an oversnow traverse, ITASE offers scientists the opportunity to experience the dynamic range of the Antarctic environment. ITASE also offers an important interactive venue for research similar to that afforded by oceanographic research vessels and large polar field camps, without the cost of the former or the lack of mobility of the latter. More importantly, the combination of disciplines represented by ITASE provides a unique, multidimensional (space and time) view of the ice sheet and its history. ITASE has now collected > 20 000 km of snow radar, recovered more than 240 firn/ice cores (total length 7000m), remotely penetrated to similar to 4000m into the ice sheet, and sampled the atmosphere to heights of > 20 km.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE We report on workflow and process-based performance measures and their effect on clinical outcome in Solitaire FR Thrombectomy for Acute Revascularization (STAR), a multicenter, prospective, single-arm study of Solitaire FR thrombectomy in large vessel anterior circulation stroke patients. METHODS Two hundred two patients were enrolled across 14 centers in Europe, Canada, and Australia. The following time intervals were measured: stroke onset to hospital arrival, hospital arrival to baseline imaging, baseline imaging to groin puncture, groin puncture to first stent deployment, and first stent deployment to reperfusion. Effects of time of day, general anesthesia use, and multimodal imaging on workflow were evaluated. Patient characteristics and workflow processes associated with prolonged interval times and good clinical outcome (90-day modified Rankin score, 0-2) were analyzed. RESULTS Median times were onset of stroke to hospital arrival, 123 minutes (interquartile range, 163 minutes); hospital arrival to thrombolysis in cerebral infarction (TICI) 2b/3 or final digital subtraction angiography, 133 minutes (interquartile range, 99 minutes); and baseline imaging to groin puncture, 86 minutes (interquartile range, 24 minutes). Time from baseline imaging to puncture was prolonged in patients receiving intravenous tissue-type plasminogen activator (32-minute mean delay) and when magnetic resonance-based imaging at baseline was used (18-minute mean delay). Extracranial carotid disease delayed puncture to first stent deployment time on average by 25 minutes. For each 1-hour increase in stroke onset to final digital subtraction angiography (or TICI 2b/3) time, odds of good clinical outcome decreased by 38%. CONCLUSIONS Interval times in the STAR study reflect current intra-arterial therapy for patients with acute ischemic stroke. Improving workflow metrics can further improve clinical outcome. CLINICAL TRIAL REGISTRATION: URL http://www.clinicaltrials.gov. Unique identifier: NCT01327989.