653 resultados para SYNDIOTACTIC POLYPROPYLENE
Resumo:
Understanding and controlling the structural anisotropies of injection-molded polymers is vital for designing products such as cantilever-based sensors. Such micro-cantilevers are considered as cost-effective alternatives to single-crystalline silicon-based sensors. In order to achieve similar sensing characteristics,structure and morphology have to be controlled by means of processing parameters including mold temperature and injection speed. Synchrotron radiation-based scanning small- (SAXS) and wide-angle x-ray scattering techniques were used to quantify crystallinity and anisotropy in polymer micro-cantilevers with micrometer resolution in real space. SAXS measurements confirmed the lamellar nature of the injection-molded semi-crystalline micro-cantilevers. The homogenous cantilever material exhibits a lamellar periodicity increasing with mold temperature but not with injection speed. We demonstrate that micro-cantilevers made of semi-crystalline polymers such as polyvinylidenefluoride, polyoxymethylene, and polypropylene show the expected strong degree of anisotropy along the injection direction.
Resumo:
Microinjection molding was employed to fabricate low-cost polymer cantilever arrays for sensor applications. Cantilevers with micrometer dimensions and aspect ratios as large as 10 were successfully manufactured from polymers, including polypropylene and polyvinylidenfluoride. The cantilevers perform similar to the established silicon cantilevers, with Q-factors in the range of 10–20. Static deflection of gold coated polymer cantilevers was characterized with heat cycling and self-assembled monolayer formation of mercaptohexanols. A hybrid mold concept allows easy modification of the surface topography, enabling customized mechanical properties of individual cantilevers. Combined with functionalization and surface patterning, the cantilever arrays are qualified for biomedical applications
Resumo:
PURPOSE The purpose of this study was to investigate whether there are microbiological differences in bacterial samples collected from labial piercings made of different materials. METHODS Sterile piercings of 4 materials were randomly allocated to 80 pierced subjects. After 2 weeks, microbiologic samples were collected and processed by checkerboard DNA-DNA hybridization methods. Wilcoxon signed ranks and Mann-Whitney tests were used for statistical analysis (adjustment for multiple comparisons). RESULTS There were no statistically significant differences between material groups in relation to baseline data. In samples from stainless steel piercings, the total microbial load was significantly higher than the other materials (P<.05). Ten (mainly periopathogenic) species were found at significantly higher levels (P<.001) on steel than on polypropylene and/or polytetrafluoroethylene piercings. CONCLUSIONS Labial piercings made of stainless steel could promote the development of a pathogenic biofilm.
Resumo:
OBJECTIVES Oxygenation of blood and other physiological solutions are routinely required in fundamental research for both in vitro and in vivo experimentation. However, very few oxygenators with suitable priming volumes (<2-3 ml) are available for surgery in small animals. We have designed a new, miniaturized membrane oxygenator and investigated the oxygen-transfer performance using both buffer and blood perfusates. METHODS The mini-oxygenator was designed with a central perforated core-tube surrounded by parallel-oriented microporous polypropylene hollow fibres, placed inside a hollow shell with a lateral-luer outlet, and sealed at both extremities. With this design, perfusate is delivered via the core-tube to the centre of the mini-oxygenator, and exits via the luer port. A series of mini-oxygenators were constructed and tested in an in vitro perfusion circuit by monitoring oxygen transfer using modified Krebs-Henseleit buffer or whole porcine blood. Effects of perfusion pressure and temperature over flows of 5-60 ml × min(-1) were assessed. RESULTS Twelve mini-oxygenators with a mean priming volume of 1.5 ± 0.3 ml were evaluated. With buffer, oxygen transfer reached a maximum of 14.8 ± 1.0 ml O2 × l(-1) (pO2: 450 ± 32 mmHg) at perfusate flow rates of 5 ml × min(-1) and decreased with an increase in perfusate flow to 7.8 ± 0.7 ml ml O2 × l(-1) (pO2: 219 ± 24 mmHg) at 60 ml × min(-1). Similarly, with blood perfusate, oxygen transfer also decreased as perfusate flow increased, ranging from 33 ± 5 ml O2 × l(-1) at 5 ml × min(-1) to 11 ± 2 ml O2 × l(-1) at 60 ml × min(-1). Furthermore, oxygen transfer capacity remained stable with blood perfusion over a period of at least 2 h. CONCLUSIONS We have developed a new miniaturized membrane oxygenator with an ultra-low priming volume (<2 ml) and adequate oxygenation performance. This oxygenator may be of use in overcoming current limitations in equipment size for effective oxygenation in low-volume perfusion circuits, such as small animal extracorporeal circulation and ex vivo organ perfusion.
Resumo:
Gebiet: Chirurgie Biomedizintechnik Biophysik Transplantationsmedizin Kardiologie Abstract: OBJECTIVES: – Oxygenation of blood and other physiological solutions are routinely required in fundamental research for both in vitro and in vivo experimentation. However, very few oxygenators with suitable priming volumes (<2-3 ml) are available for surgery in small animals. We have designed a new, miniaturized membrane oxygenator and investigated the oxygen-transfer performance using both buffer and blood perfusates. – – METHODS: – The mini-oxygenator was designed with a central perforated core-tube surrounded by parallel-oriented microporous polypropylene hollow fibres, placed inside a hollow shell with a lateral-luer outlet, and sealed at both extremities. With this design, perfusate is delivered via the core-tube to the centre of the mini-oxygenator, and exits via the luer port. A series of mini-oxygenators were constructed and tested in an in vitro perfusion circuit by monitoring oxygen transfer using modified Krebs-Henseleit buffer or whole porcine blood. Effects of perfusion pressure and temperature over flows of 5-60 ml × min(-1) were assessed. – – RESULTS: – Twelve mini-oxygenators with a mean priming volume of 1.5 ± 0.3 ml were evaluated. With buffer, oxygen transfer reached a maximum of 14.8 ± 1.0 ml O2 × l(-1) (pO2: 450 ± 32 mmHg) at perfusate flow rates of 5 ml × min(-1) and decreased with an increase in perfusate flow to 7.8 ± 0.7 ml ml O2 × l(-1) (pO2: 219 ± 24 mmHg) at 60 ml × min(-1). Similarly, with blood perfusate, oxygen transfer also decreased as perfusate flow increased, ranging from 33 ± 5 ml O2 × l(-1) at 5 ml × min(-1) to 11 ± 2 ml O2 × l(-1) at 60 ml × min(-1). Furthermore, oxygen transfer capacity remained stable with blood perfusion over a period of at least 2 h. – – CONCLUSIONS: – We have developed a new miniaturized membrane oxygenator with an ultra-low priming volume (<2 ml) and adequate oxygenation performance. This oxygenator may be of use in overcoming current limitations in equipment size for effective oxygenation in low-volume perfusion circuits, such as small animal extracorporeal circulation and ex vivo organ perfusion. – – © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Resumo:
El gran desarrollo industrial y demográfico de las últimas décadas ha dado lugar a un consumo crecientemente insostenible de energía y materias primas, que influye negativamente en el ambiente por la gran cantidad de contaminantes generados. Entre las emisiones tienen gran importancia los compuestos orgánicos volátiles (COV), y entre ellos los compuestos halogenados como el tricloroetileno, debido a su elevada toxicidad y resistencia a la degradación. Las tecnologías generalmente empleadas para la degradación de estos compuestos presentan inconvenientes derivados de la generación de productos tóxicos intermedios o su elevado coste. Dentro de los procesos avanzados de oxidación (Advanced Oxidation Processes AOP), la fotocatálisis resulta una técnica atractiva e innovadora de interés creciente en su aplicación para la eliminación de multitud de compuestos orgánicos e inorgánicos, y se ha revelado como una tecnología efectiva en la eliminación de compuestos orgánicos volátiles clorados como el tricloroetileno. Además, al poder aprovechar la luz solar como fuente de radiación UV permite una reducción significativa de costes energéticos y de operación. Los semiconductores más adecuados para su empleo como fotocatalizadores con aprovechamiento de la luz solar son aquellos que tienen una banda de energía comparable a la de los fotones de luz visible o, en su defecto, de luz ultravioleta A (Eg < 3,5 eV), siendo el más empleado el dióxido de titanio (TiO2). El objetivo principal de este trabajo es el estudio de polímeros orgánicos comerciales como soporte para el TiO2 en fotocatálisis heterogénea y su ensayo para la eliminación de tricloroetileno en aire. Para ello, se han evaluado sus propiedades ópticas y su resistencia a la fotodegradación, y se ha optimizado la fijación del fotocatalizador para conseguir un recubrimiento homogéneo, duradero y con elevada actividad fotocatalítica en diversas condiciones de operación. Los materiales plásticos ensayados fueron el polietileno (PE), copolímero de etil vinil acetato con distintos aditivos (EVA, EVA-H y EVA-SH), polipropileno (PP), polimetil (metacrilato) fabricado en colada y extrusión (PMMA-C y PMMA-E), policarbonato compacto y celular (PC-C y PC-Ce), polivinilo rígido y flexible (PVC-R y PVC-F), poliestireno (PS) y poliésteres (PET y PETG). En base a sus propiedades ópticas se seleccionaron el PP, PS, PMMA-C, EVA-SH y PVC-R, los cuales mostraron un valor de transmitancia superior al 80% en el entorno de la región estudiada (λ=365nm). Para la síntesis del fotocatalizador se empleó la tecnología sol-gel y la impregnación multicapa de los polímeros seleccionados por el método de dip-coating con secado intermedio a temperaturas moderadas. Con el fin de evaluar el envejecimiento de los polímeros bajo la radiación UV, y el efecto sobre éste del recubrimiento fotoactivo, se realizó un estudio en una cámara de exposición a la luz solar durante 150 días, evaluándose la resistencia química y la resistencia mecánica. Los resultados de espectroscopía infrarroja y del test de tracción tras el envejecimiento revelaron una mayor resistencia del PMMA y una degradación mayor en el PS, PVC-R y EVA SH, con una apreciable pérdida del recubrimiento en todos los polímeros. Los fotocatalizadores preparados sobre soportes sin tratamiento y con tres capas de óxido de titanio mostraron mejores resultados de actividad con PMMA-C, PET y PS, con buenos resultados de mineralización. Para conseguir una mayor y mejor fijación de la película al soporte se realizaron tratamientos químicos abrasivos con H2SO4 y NaOH y tratamientos de funcionalización superficial por tecnología de plasma a presión atmosférica (APP) y a baja presión (LPP). Con los tratamientos de plasma se consiguió una excelente mojabilidad de los soportes, que dio lugar a una distribución uniforme y más abundante del fotocatalizador, mientras que con los tratamientos químicos no se obtuvo una mejora significativa. Asimismo, se prepararon fotocatalizadores con una capa previa de dióxido de silicio con la intervención de surfactantes (PDDA-SiO2-3TiO2 y SiO2FC-3TiO2), consiguiéndose buenas propiedades de la película en todos los casos. Los mejores resultados de actividad con tratamiento LPP y tres capas de TiO2 se lograron con PMMA-C (91% de conversión a 30 ppm de TCE y caudal 200 ml·min-1) mejorando significativamente también la actividad fotocatalítica en PVC-R y PS. Sin embargo, el material más activo de todos los ensayados fue el PMMA-C con el recubrimiento SiO2FC-3TiO2, logrando el mejor grado de mineralización, del 45%, y una velocidad de 1,89 x 10-6 mol· m-2 · s-1, que dio lugar a la eliminación del 100 % del tricloroetileno en las condiciones anteriormente descritas. A modo comparativo se realizaron ensayos de actividad con otro contaminante orgánico tipo, el formaldehído, cuya degradación fotocatalítica fue también excelente (100% de conversión y 80% de mineralización con 24 ppm de HCHO en un caudal de aire seco de 200 ml·min-1). Los buenos resultados de actividad obtenidos confirman las enormes posibilidades que ofrecen los polímeros transparentes en el UV-A como soportes del dióxido de titanio para la eliminación fotocatalítica de contaminantes en aire. ABSTRACT The great industrial and demographic development of recent decades has led to an unsustainable increase of energy and raw materials consumption that negatively affects the environment due to the large amount of waste and pollutants generated. Between emissions generated organic compounds (VOCs), specially the halogenated ones such as trichloroethylene, are particularly important due to its high toxicity and resistance to degradation. The technologies generally used for the degradation of these compounds have serious inconveniences due to the generation of toxic intermediates turn creating the problem of disposal besides the high cost. Among the advanced oxidation processes (AOP), photocatalysis is an attractive and innovative technique with growing interest in its application for the removal of many organic and inorganic compounds, and has emerged as an effective technology in eliminating chlorinated organic compounds such as trichloroethylene. In addition, as it allows the use of sunlight as a source of UV radiation there is a significant reduction of energy costs and operation. Semiconductors suitable to be used as photocatalyst activated by sunlight are those having an energy band comparable to that of the visible or UV-A light (Eg <3,5 eV), being titanium dioxide (TiO2), the most widely used. The main objective of this study is the test of commercial organic polymers as supports for TiO2 to be applied in heterogeneous photocatalysis and its assay for removing trichloroethylene in air. To accomplish that, its optical properties and resistance to photooxidation have been evaluated, and different operating conditions have been tested in order to optimize the fixation of the photocatalyst to obtain a homogeneous coating, with durable and high photocatalytic activity. The plastic materials tested were: polyethylene (PE), ethyl vinyl acetace copolymers with different additives (EVA, EVA-H and EVA -SH), polypropylene (PP), poly methyl (methacrylate) manufactured by sheet moulding and extrusion (PMMA-C and PMMA-E), compact and cellular polycarbonates (PC-C PC-Ce), rigid and flexible polyvinyl chloride (PVC-R and PVC-F), polystyrene (PS) and polyesters (PET and PETG). On the basis of their optical properties PP, PS, PMMA-C, EVA-SH and PVC-R were selected, as they showed a transmittance value greater than 80% in the range of the studied region (λ = 365nm). For the synthesis of the photocatalyst sol-gel technology was employed with multilayers impregnation of the polymers selected by dip-coating, with intermediate TiO2 drying at moderate temperatures. To evaluate the polymers aging due to UV radiation, and the effect of photoactive coating thereon, a study in an sunlight exposure chamber for 150 days was performed, evaluating the chemical resistance and the mechanical strength. The results of infrared spectroscopy and tensile stress test after aging showed the PMMA is the most resistant sample, but a greater degradation in PS, PVC-R and EVA SH, with a visible loss of the coating in all the polymers tested. The photocatalysts prepared on the untreated substrates with three layers of TiO2 showed better activity results when PMMA-C, PET and PS where used. To achieve greater and better fixation of the film to the support, chemical abrasive treatments, with H2SO4 and NaOH, as well as surface functionalization treatments with atmospheric pressure plasma (APP) and low pressure plasma (LPP) technologies were performed. The plasma treatment showed the best results, with an excellent wettability of the substrates that lead to a better and uniform distribution of the photocatalyst compared to the chemical treatments tested, in which no significant improvement was obtained. Also photocatalysts were prepared with the a silicon dioxide previous layer with the help of surfactants (SiO2- 3TiO2 PDDA-and-3TiO2 SiO2FC), obtaining good properties of the film in all cases. The best activity results for LPP-treated samples with three layers of TiO2 were achieved with PMMA-C (91% conversion, in conditions of 30 ppm of TCE and 200 ml·min-1 air flow rate), with a significant improvement of the photocatalytic activity in PVC-R and PS samples too. However, among all the materials assayed, PMMA-C with SiO2FC-3TiO2 coating was the most active one, achieving the highest mineralization grade (45%) and a reaction rate of 1,89 x 10-6 mol· m-2 · s-1, with total trichloroethylene elimination in the same conditions. As a comparative assay, an activity test was also performed with another typical organic contaminant, formaldehyde, also with good results (100% conversion with 24 ppm of HCHO and 200 ml·min-1 gas flow rate). The good activity results obtained in this study confirm the great potential of organic polymers which are transparent in the UV-A as supports for titanium dioxide for photocatalytic removal of air organic pollutants.
Resumo:
A constitutive model is presented for the in-plane mechanical behavior of nonwoven fabrics. The model is developed within the context of the finite element method and provides the constitutive response for a mesodomain of the fabric corresponding to the area associated to a finite element. The model is built upon the ensemble of three blocks, namely fabric, fibers and damage. The continuum tensorial formulation of the fabric response rigorously takes into account the effect of fiber rotation for large strains and includes the nonlinear fiber behavior. In addition, the various damage mechanisms experimentally observed (bond and fiber fracture, interfiber friction and fiber pull-out) are included in a phenomenological way and the random nature of these materials is also taken into account by means of a Monte Carlo lottery to determine the damage thresholds. The model results are validated with recent experimental results on the tensile response of smooth and notched specimens of a polypropylene nonwoven fabric.
Resumo:
The reinforcing effect of inorganic fullerene-like tungsten disulfide (IF-WS2) nanoparticles in two different polymer matrices, isotactic polypropylene (iPP) and polyphenylene sulfide (PPS), has been investigated by means of dynamic depth-sensing indentation. The hardness and elastic modulus enhancement upon filler addition is analyzed in terms of two main contributions: changes in the polymer matrix nanostructure and intrinsic properties of the filler including matrix-particle load transfer. It is found that the latter mainly determines the overall mechanical improvement, whereas the nanostructural changes induced in the polymer matrix only contribute to a minor extent. Important differences are suggested between the mechanisms of deformation in the two nanocomposites, resulting in a moderate mechanical enhancement in case of iPP (20% for a filler loading of 1%), and a remarkable hardness increase in case of PPS (60% for the same filler content). The nature of the polymer amorphous phase, whether in the glassy or rubbery state, seems to play here an important role. Finally, nanoindentation and dynamic mechanical analysis measurements are compared and discussed in terms of the different directionality of the stresses applied.
Resumo:
Polymer/inorganic nanoparticle nanocomposites have garnered considerable academic and industrial interest over recent decades in the development of advanced materials for a wide range of applications. In this respect, the dispersion of so-called inorganic fullerene-like (IF) nanoparticles, e.g., tungsten disulfide (IF-WS2) or molybdenum disulfide (IF-MoS2), into polymeric matrices is emerging as a new strategy. The surprising properties of these layered metal dichalcogenides such as high impact resistance and superior tribological behavior, attributed to their nanoscale size and hollow quasi-spherical shape, open up a wide variety of opportunities for applications of these inorganic compounds. The present work presents a detailed overview on research in the area of IF-based polymer nanocomposites, with special emphasis on the use of IF-WS2 nanoparticles as environmentally friendly reinforcing fillers. The incorporation of IF particles has been shown to be efficient for improving thermal, mechanical and tribological properties of various thermoplastic polymers, such as polypropylene, nylon-6, poly(phenylene sulfide), poly(ether ether ketone), where nanocomposites were fabricated by simple melt-processing routes without the need for modifiers or surfactants. This new family of nanocomposites exhibits similar or enhanced performance when compared with nanocomposites that incorporate carbon nanotubes, carbon nanofibers or nanoclays, but are substantially more cost-effective, efficient and environmentally satisfactory. Most recently, innovative approaches have been described that exploit synergistic effects to produce new materials with enhanced properties, including the combined use of micro- and nanoparticles such as IF-WS2/nucleating agent or IF-WS2/carbon fiber, as well as dual nanoparticle systems such as SWCNT/IF-WS2 where each nanoparticle has different characteristics. The structure–property relationships of these nanocomposites are discussed and potential applications proposed ranging from medicine to the aerospace, automotive and electronics industries.
Resumo:
A resistência de cinco microrganismos presentes na microbiota da área de produção estéril (Cristalização Estéril), frente a ação do gás de peróxido de hidrogênio foi determinada e o valor O obtido para cada microrganismo foi comparado ao valor D do Bacillus stearothermophilus ATCC 12980 exposto ao mesmo agente. Os microrganismos testados foram Bacillus sp, M. luteus, Corynebacterium, Staphylococcus sp e Penicillium sp. Este teste tinha a finalidade de comprovar que a resistência do Bacillus stearothermophilus é maior quando da exposição ao peróxido de hidrogênio se comparada a outros microrganismos presentes na área produtiva. A metodologia consistiu da inoculação de 0,01 mL da suspensão de cada microrganismo na contagem de 102UFC/0,01 mL em cupons de aço inoxidável, previamente esterilizados por calor seco e posterior exposição ao gás de peróxido de hidrogênio. O experimento demonstrou que o valor D obtido para o Bacillus stearothermophilus ésuperior aos obtidos para os outros microrganismos em teste comprovando que a escolha deste microrganismo para o desafio contra o peróxido de hidrogênio é apropriada. Também executou-se o teste que visava garantir que o aço inoxidável é o material de suporte mais recomendado para este fim, utilizando-se suportes de diversos materiais normalmente encontrados no interior dos isoladores (PVC, aço inoxidável, CKC, teflon, polipropileno, látex, silicone, Hypalon, vidro, nylon, saco de alumínio) com 0,01 mL de inóculo de Bacillus stearothermophilus na contagem de 102UFC/O,01 mL, o que foi devidamente comprovado.
Resumo:
Este trabalho está dividido em: obtenção e caracterização de amido termoplástico (TPS); estudo do envelhecimento do TPS e blendas de PP/TPS. O estudo do TPS, foi realizado utilizando amido de milho, 30% em massa de glicerol e outros componentes que variam entre as amostras. Primeiramente foi realizado um planejamento estatístico para obter a composição ótima de TPS. Foram escolhidos cinco parâmetros de entrada: 2 de composição (umidade e teor de ácido cítrico) e 3 de processamento (temperatura, velocidade dos rotores e tempo), visando obter um TPS com propriedades térmicas e mecânicas superiores. De acordo com os resultados de infravermelho, termogravimetria, microscopia ótica (MO) e microscopia eletrônica de varredura (MEV) foram escolhidas 2 composições. Estas foram calandradas e confeccionadas para obtenção dos corpos de prova de tração. Os resultados dos ensaios mecânicos mostraram que amostras com teor de ácido cítrico de aproximadamente 2% em massa apresentam os maiores valores de módulo de elasticidade e resistência à tração. Com estes resultados foram realizadas novas composições com outros ácidos carboxílicos: adípico, málico e tartárico e amostras sem ácidos. As curvas de torque indicaram que as amostras sem ácido carboxílico e com ácido adípico perdem água durante o processamento. Analisando os resultados verifica-se que o TPS com os ácidos málico e tartárico apresentam melhores propriedades mecânicas e térmicas. Também foi analisado o envelhecimento, e notou-se que com o tempo as amostras tendem a perder plastificante, modificando suas propriedades mecânicas e sua cristalinidade. Entretanto, durante o intervalo de um ano, as amostras de TPS com ácido málico e tartárico não sofreram perda significativa de plastificante. Por último, foram obtidas blendas de PP reciclado com TPS nas composições 50/50, 60/40 e 70/30 em massa, respectivamente, com e sem adição de ácidos: cítrico, málico e tartárico e anidrido maleico. As amostras foram caracterizadas por FTIR, DRX, reometria capilar, MEV e por teste de resistência à tração. Micrografias obtidas por MEV indicaram que todas as composições estudadas possuem morfologia predominantemente co-contínua. A presença dos ácidos, geralmente, reduz os valores das propriedades mecânicas da blenda de PP com TPS e a adição de PP-g-MA é mais efetiva nas blendas sem adição de ácido. Ao analisar o envelhecimento das blendas com adição de ácidos tartárico e málico, notou-se que as propriedades mecânicas não foram alteradas em função do tempo de estocagem.
Resumo:
Este trabalho aborda o estudo do comportamento mecânico e térmico do nanocompósito híbrido de polipropileno com uma argila brasileira bentonítica do Estado da Paraíba (PB), conhecida como \"chocolate\" com concentração de 1, 2 e 5 % em massa com a adição de 1 e 2 % em massa de celulose proveniente de papel descartado. Foi utilizado nesse nanocompósito o agente compatibilizante polipropileno graftizado com anidrido maleico PP-g-AM com 3 % de concentração em massa, através da técnica de intercalação do fundido utilizando uma extrusora de dupla-rosca e, em seguida, os corpos de prova foram confeccionados em uma injetora. O comportamento mecânico foi avaliado pelos ensaios de tração, flexão e impacto. O comportamento térmico foi avaliado pelas técnicas de calorimetria exploratória diferencial (DSC) e termogravimetria (TGA). A morfologia dos nanocompósitos foi estudada pela técnica de microscopia eletrônica de varredura (MEV). A argila, a celulose e os nanocompósitos híbridos foram caracterizados por difração de raios X (DRX), fluorescência de raios X (FRX) e espectroscopia no infravermelho (FTIR). Nos ensaios mecânicos de tração houve um aumento de 11 % na tensão máxima em tração e 15 % no módulo de Young, para o nanocompósito com argila, PPA 5 %. No ensaio de impacto Izod, o nanocompósito com argila, PPA 2 % obteve um aumento de 63 % na resistência ao impacto. Para o nanocompósito híbrido PPAC 1 % houve aumento de 8 % na tensão máxima em tração e para o nanocompósito híbrido PPAC 2 % houve aumento de 14 % na resistência ao impacto.
Resumo:
En el siguiente trabajo se realiza la impregnación de diferentes sustratos poliméricos con agentes biocidas y con un colorante textil, comúnmente empleados en los procesos de acabados textiles. En este estudio se realiza la selección del colorante Disperse Red 167 (DR167), mediante la comparación de solubilidad en CO2 supercrítico (scCO2) entre varios colorantes dispersos. Los agentes biocidas seleccionados han sido; esencia de clavo (eugenol) y aceite esencial de orégano. Se ha realizado la impregnación de diferentes sustratos poliméricos; poliéster (PES), polipropileno (PP), y algodón (CO), en diferentes condiciones. En total se realizaron impregnaciones utilizando diez concentraciones relativas del DR167. El objetivo principal es determinar las condiciones óptimas de procesado para cada sustrato. Para determinar el rendimiento de la tintura en scCO2 se han representado los diagramas cromáticos de las muestras tintadas en diferentes condiciones. Las muestras de PES son las que presentan mayor rendimiento de color, sabiendo que esta es la única fibra que presenta afinidad con el DR167. Para determinar el efecto de inhibición de las bacterias se han realizado ensayos de actividad antimicrobiana y actividad fungicida. Puede indicarse que sí se observó cierta actividad inhibitoria frente algunos microorganismos, como Staphylococcus aureus, mientras que no se observó una actividad inhibitoria importante frente a otros como Pseudomonas aeruginosa.
Resumo:
En el conjunto de materiales de construcción habituales en la edificación y las obras de ingeniería, el hormigón destaca entre otras razones por su excelente comportamiento frente a las altas temperaturas y la exposición al fuego. El presente estudio se centra en la adherencia residual entre el hormigón y las barras de acero corrugado soldable tras exponer probetas a altas temperaturas y enfriarlas hasta temperatura ambiente por convección natural. El estudio incluye hormigones de resistencia convencional, hormigones de alta resistencia y hormigones reforzados con fibras de polipropileno y fibras de acero. La adherencia hormigón-acero se ha medido mediante el conocido ensayo de pull-out. La campaña experimental también ha incluido la resistencia a compresión y la resistencia a tracción indirecta. Parte de las probetas se han ensayado a 28 días de edad a temperatura ambiente. A 60 días de edad se han repetido los ensayos a temperatura ambiente y se han realizado esos mismos ensayos en probetas calentadas en un horno industrial hasta tres rangos de temperatura: 450°C, 650°C y 825°C. Previo al proceso de calentamiento han sido sometidas durante 3 horas a un escalón de secado a 120°C. Mediante la metodología propuesta ha sido posible caracterizar la evolución de la pérdida de adherencia residual entre el acero y el hormigón conforme se exponen los especímenes a temperaturas más elevadas. La adición de fibras no tiene una influencia clara en la adherencia a temperatura ambiente. Sin embargo, sí se ha conseguido determinar una mejora sustancial de la adherencia residual en los hormigones, reforzados con fibras de acero sometidos a altas temperaturas.
Resumo:
Particle flow patterns were investigated for wet granulation and dry powder mixing in ploughshare mixers using Positron Emission Particle Tracking (PEPT). In a 4-1 mixer, calcium carbonate with mean size 45 mum was granulated using a 50 wt.% solution of glycerol and water as binding fluid, and particle movement was followed using a 600-mum calcium hydroxy-phosphate tracer particle. In a 20-1 mixer, dry powder flow was studied using a 600-mum resin bead tracer particle to simulate the bulk polypropylene powder with mean size 600 mum. Important differences were seen between particle flow patterns for wet and dry systems. Particle speed relative to blade speed was lower in the wet system than in the dry system, with the ratios of average particle speed to blade tip speed for all experiments in the range 0.01-015. In the axial plane, the same particle motion was observed around each blade; this provides a significant advance for modelling flow in ploughshare mixers. For the future, a detailed understanding of the local velocity, acceleration and density variations around a plough blade will reveal the effects of flow patterns in granulating systems on the resultant distribution of granular product attributes such as size, density and strength. (C) 2002 Elsevier Science B.V All rights reserved.