981 resultados para SENSITIVE DETERMINATION
Resumo:
The determination of settlement of shallow foundations on cohesionless soil is an important task in geotechnical engineering. Available methods for the determination of settlement are not reliable. In this study, the support vector machine (SVM), a novel type of learning algorithm based on statistical theory, has been used to predict the settlement of shallow foundations on cohesionless soil. SVM uses a regression technique by introducing an ε – insensitive loss function. A thorough sensitive analysis has been made to ascertain which parameters are having maximum influence on settlement. The study shows that SVM has the potential to be a useful and practical tool for prediction of settlement of shallow foundation on cohesionless soil.
Resumo:
This paper proposes the use of empirical modeling techniques for building microarchitecture sensitive models for compiler optimizations. The models we build relate program performance to settings of compiler optimization flags, associated heuristics and key microarchitectural parameters. Unlike traditional analytical modeling methods, this relationship is learned entirely from data obtained by measuring performance at a small number of carefully selected compiler/microarchitecture configurations. We evaluate three different learning techniques in this context viz. linear regression, adaptive regression splines and radial basis function networks. We use the generated models to a) predict program performance at arbitrary compiler/microarchitecture configurations, b) quantify the significance of complex interactions between optimizations and the microarchitecture, and c) efficiently search for'optimal' settings of optimization flags and heuristics for any given microarchitectural configuration. Our evaluation using benchmarks from the SPEC CPU2000 suits suggests that accurate models (< 5% average error in prediction) can be generated using a reasonable number of simulations. We also find that using compiler settings prescribed by a model-based search can improve program performance by as much as 19% (with an average of 9.5%) over highly optimized binaries.
Resumo:
Background: Clinicians frequently use their own judgement to assess patient’s hydration status although there is limited evidence for the diagnostic utility of any individual clinical symptom. Hence, the aim of this study was to compare the diagnostic accuracy of clinically assessed dehydration in older hospital patients (using multiple symptoms), versus dehydration measured using serum-calculated osmolality (CO) as the reference standard. Method: Participants were 44 hospital patients aged ≥ 60 years. Dehydration was assessed clinically and pathologically (CO) within 24 hours of admission and at study exit. Indicators of diagnostic accuracy were calculated. Results: Clinicians identified 27% of patients as dehydrated at admission, and 19% at exit, compared to 19% and 16% using CO. Agreement between the measures was fair at admission and poor at exit. Clinical assessment showed poor sensitivity for predicting dehydration with reasonable specificity. Conclusions: Compared to the use of CO, clinical assessment of dehydration in older patients was poor. Given that failure to identify dehydration in this population may have serious consequences, we recommend that clinicians do not rely upon their own assessments without also using the reference standard.
Resumo:
Serine hydroxymethyltransferase (SHMT) belongs to the alpha-family of pyridoxal 5'-phosphate-dependent enzymes and catalyzes the reversible conversion of L-Ser and etrahydrofolate to Gly and 5,10-methylene tetrahydrofolate. 5,10-Methylene tetrahydrofolate serves as a source of one-carbon fragment in many biological processes. SHMT also catalyzes the tetrahydrofolate-independent conversion of L-allo-Thr to Gly and acetaldehyde. The crystal structure of Bacillus stearothermophilus SHMT (bsSHMT) suggested that E53 interacts with the substrate, L-Ser and etrahydrofolate. To elucidate the role of E53, it was mutated to Q and structural and biochemical studies were carried out with the mutant enzyme. The internal aldimine structure of E53QbsSHMT was similar to that of the except for significant changes at Q53, Y60 and Y61. The wild-type enzyme, carboxyl of Gly and side chain of L-Ser were in two conformations in the respective external aldimine structures. The mutant enzyme was completely inactive for tetrahydrofolate-depen dent cleavage of L-Ser, whereas there was a 1.5-fold increase in the rate of tetrahydrofolate-independent reaction with L-allo-Thr. The results obtained from these studies suggest that E53 plays an essential role in tetrahydrofolate/5-formyl tetrahydrofolate binding and in the proper positioning of C beta of L-Ser for direct attack by N5 of tetrahydrofolate. Most interestingly, the structure of the complex obtained by cocrystallization of E53QbsSHMT with Gly and 5-formyl tetrahydrofolate revealed the gem-diamine form of pyridoxal 5'-phosphate bound to Gly and active site Lys. However, density for 5-formyl tetrahydrofolate was not observed. Gly carboxylate was in a single conformation, whereas pyridoxal 5'-phosphate had two distinct conformations. The differences between the structures of this complex and Gly external aldimine suggest that the changes induced by initial binding of 5-formyl tetrahydrofolate are retained even though 5-formyl tetrahydrofolate is absent in the final structure. Spectral studies carried out with this mutant enzyme also suggest that 5-formyl tetrahydrofolate binds to the E53QbsSHMT-Gly complex forming a quinonoid intermediate and falls off within 4 h of dialysis, leaving behind the mutant enzyme in the gemdiamine form. This is the first report to provide direct evidence for enzyme memory based on the crystal structure of enzyme complexes.
Resumo:
Herein is described a method by which component gases can be weighed as they are added one by one to a gas mixture. The float balance, designed for the purpose, is capable of determining a maximum mass of about 3 kg of a gas mixture contained in a cylinder of mass about 5 kg with a sensitivity of ±0·1 g mm-1 of the stem height.
Resumo:
Suitable pin-to-hole interference can significantly increase the fatigue life of a pin joint. In practical design, the initial stresses due to interference are high and they are proportional to the effective interference. In experimental studies on such joints, difficulties have been experienced in estimating the interference accurately from physical measurements of pin and hole diameters. A simple photoelastic method has been developed to determine the effective interference to a high degree of accuracy. This paper presents the method and reports illustrative data from a successful application thereof.
Resumo:
An analytical method for the determination of tetra-alkylthiuram disulphides has been developed, based on the quantitative oxidation of carbon disulphide produced by acidified chloramine-T to sulphuric and formic acids. Twenty-eight equivalents of chloramine-T are required per mole of a thiuram disulphide.
Resumo:
A method for the volumetric determination of tetraalkyl thiuram disulphide is developed. It is based on its reaction with potassium cyanide in aqueous acetonitrile medium, when the corresponding tetraalkyl thiuram monosulphide and thiocyanate are formed. The former is removed by extraction with benzene and the latter converted into cyanogen bromide, which is estimated iodometrically.
Resumo:
A volumetric method for the quantitative determination of Sulphoxides has been developed, based on their oxidation to sulphones by dichromate in presence of 5 M sulphuric acid at 105–110°C. Excess dichromate is titrated by ferrous ammonium sulphate solution. The method is also applicable to the determination of Sulphoxides in metal sulphoxide complexes.
Resumo:
It is well known that the analysis of vibration of orthogonally stiffened rectangular plates and grillages may be simplified by replacing the actual structure by an orthotropic plate. This needs a suitable determination of the four elastic rigidity constants Dx, Dy, Dxy, D1 and the mass {Mathematical expression} of the orthotropic plate. A method is developed here for determining these parameters in terms of the sectional properties of the original plate-stiffener combination or the system of interconnected beams. Results of experimental work conducted on aluminium plates agree well with the results of the theory developed here.
Resumo:
A new method for the titrimetric determination of perchlorate has been developed, based on its reduction to chloride by iron(II) in a strong sulphuric acid medium at high temperature. The effect of variables, such as the sulphuric acid concentration, the temperature and the period of heating, on the extent of reduction has been studied and the optimal conditions for analytical determination of perehlorate derived.
Resumo:
A rapid method is described for the determination of sulphur monochloride by adding excess of chloramine-T and determining the excess iodometrically.