919 resultados para Reduction of a ketone


Relevância:

100.00% 100.00%

Publicador:

Resumo:

We show that by optimizing the amplifier position in a two-stage dispersion map, the (dispersion-managed) soliton-soliton interaction can be reduced, enabling transmission of 10-Gbits-1 solitons over standard fiber over 16,000 km

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We show experimentally and numerically that in high-speed strongly dispersion-managed standard fiber soliton systems nonlinear interactions limit the propagation distance. We present results that show that the effect of these interactions can be significantly reduced by appropriate location of the amplifier within the dispersion map. Using this technique, we have been able to extend the propagation distance of 10-Gbit/s 231–1pseudorandom binary sequence soliton data to 16, 500km over standard fiber by use of dispersion compensation. To our knowledge this distance is the farthest transmission over standard fiber without active control ever reported, and it was achieved with the amplifier placed after the dispersion-compensating fiber in a recirculating loop.

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Automotive catalysts are the most effective short-term answer to air pollution from automobiles. Since strict control of exhaust emissions is, or will be,covered by legislation in most developed countries in the world, catalytic devices will be increasingly fitted to cars. There is consequently an urgent need for the development of catalysts that will not compete for scarce precious metal resources. A number of problems have already been identified in connection with base metal catalysts but quantitative investigations are lacking. The base metal reduction catalysts developed by Imperial Chemical Industries Limited, catalysts and Chemical Group, in collaboration with the Air Pollution Control Laboratory, B L Cars Limited for automotive emission control, are susceptible to de-activation by three major mechanisms. These are: physical loss of the wash-coat (a high surface area coating which supports the active species), aggregation of the active species and poisoning by fuel and engine oil additives. This thesis is especially concerned with the first two of these and attempts to indicate the relative magnitude .of their effect on the activity of. the catalysts. Aggregation of the active species or sintering, as it is loosely called, was studied by using impregnated granules to overcome effects due to the loss of the wash-coat. Samples were aged in a synthetic exhaust gas, free from poisons, and metal crystallite sizes were measured by scanning-electron microscopy. The increase in particle size was correlated with the loss in catalytic activity. In order to maintain a link with the real conditions of service a number of monolithic catalysts were tested in an engine-dynamometer and several previously tested endurance catalysts were examined. A mechanism is proposed for the break-up and subsequent 10s.5 of the wash-coat and suggestions for improved resistance to loss of the' coating and active species are proposed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The work described in this thesis is directed towards the reduction of noise levels in the Hoover Turbopower upright vacuum cleaner. The experimental work embodies a study of such factors as the application of noise source identification techniques, investigation of the noise generating principles for each major source and evaluation of the noise reducing treatments. It was found that the design of the vacuum cleaner had not been optimised from the standpoint of noise emission. Important factors such as noise `windows', isolation of vibration at the source, panel rattle, resonances and critical speeds had not been considered. Therefore, a number of experimentally validated treatments are proposed. Their noise reduction benefit together with material and tooling costs are presented. The solutions to the noise problems were evaluated on a standard Turbopower and the sound power level of the cleaner was reduced from 87.5 dB(A) to 80.4 db(A) at a cost of 93.6 pence per cleaner.The designers' lack of experience in noise reduction was identified as one of the factors for the low priority given to noise during design of the cleaner. Consequently, the fundamentals of acoustics, principles of noise prediction and absorption and guidelines for good acoustical design were collated into a Handbook and circulated at Hoover plc.Mechanical variations during production of the motor and the cleaner were found to be important. These caused a vast spread in the noise levels of the cleaners. Subsequently, the manufacturing processes were briefly studied to identify their source and recommendations for improvement are made.Noise of a product is quality related and a high level of noise is considered to be a bad feature. This project suggested that the noise level be used constructively both as a test on the production line to identify cleaners above a certain noise level and also to promote the product by `designing' the characteristics of the sound so that the appliance is pleasant to the user. This project showed that good noise control principles should be implemented early in the design stage.As yet there are no mandatory noise limits or noise-labelling requirements for household appliances. However, the literature suggests that noise-labelling is likely in the near future and the requirement will be to display the A-weighted sound power level. However, the `noys' scale of perceived noisiness was found more appropriate to the rating of appliance noise both as it is linear and therefore, a sound level that seems twice as loud is twice the value in noys and also takes into consideration the presence of pure tones, which even in the absence of a high noise level can lead to annoyance.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Preeclampsia (PE) is characterized by widespread endothelial damage with hypertension, proteinuria, glomeruloendotheliosis and elevated soluble Flt-1 (sFlt-1), a natural occurring antagonist of vascular endothelial growth factor (VEGF). Cancer patients receiving anti-VEGF therapy exhibit similar symptoms. We suggested that a decrease in circulating sFlt-1 would alleviate the symptoms associated with PE. Adenoviral (Adv) overexpression of sFlt-1 induced proteinuria, caused glomerular damage and increase in blood pressure in female Balb/c mice. Circulating level of sFlt-1 above 50 ng/ml plasma induced severe vascular damage and glomerular endotheliosis. Albumin concentration in urine was elevated up to 30-fold, compared to control AdvGFP-treated animals. The threshold of kidney damage was in the range of 20-30 ng/ml sFlt-1 in plasma (8-15 ng/ml in urine). Co-administration of AdvsFlt-1 with AdvVEGF to neutralize circulating sFlt-1 resulted in more than a 70% reduction in free sFlt-1 in plasma, more than 80% reduction in urine and rescued the damaging effect of sFlt-1 on the kidneys. This demonstrates that below a critical threshold sFlt-1 fails to elicit damage to the fenestrated endothelium and that co-expression of VEGF is able to rescue effects mediated by sFlt-1 overexpression.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We show that using a shortened delay in the demodulator for DQPSK channels can significantly reduce the XPM penalties caused by transmitting 40Gb/s DQPSK channels alongside 10Gb/s OOK channels. © 2010 Optical Society of America.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

DUE TO COPYRIGHT RESTRICTIONS ONLY AVAILABLE FOR CONSULTATION AT ASTON UNIVERSITY LIBRARY AND INFORMATION SERVICES WITH PRIOR ARRANGEMENT

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We show that using a shortened delay in the demodulator for DQPSK channels can significantly reduce the XPM penalties caused by transmitting 40Gb/s DQPSK channels alongside 10Gb/s OOK channels. © 2010 Optical Society of America.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We show experimentally and numerically that in high-speed strongly dispersion-managed standard fiber soliton systems nonlinear interactions limit the propagation distance. We present results that show that the effect of these interactions can be significantly reduced by appropriate location of the amplifier within the dispersion map. Using this technique, we have been able to extend the propagation distance of 10-Gbit/s 231–1pseudorandom binary sequence soliton data to 16, 500km over standard fiber by use of dispersion compensation. To our knowledge this distance is the farthest transmission over standard fiber without active control ever reported, and it was achieved with the amplifier placed after the dispersion-compensating fiber in a recirculating loop.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We show that by optimizing the amplifier position in a two-stage dispersion map, the (dispersion-managed) soliton-soliton interaction can be reduced, enabling transmission of 10-Gbits-1 solitons over standard fiber over 16,000 km

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We examine reduction of phase jitter by use of in-line Butterworth filters in soliton systems in the context of differential phase-shift-keying coding. We also demonstrate numerically that the use of a Butterworth filter in a return-to-zero differential phase-shift-keying system can reduce continuum background radiation.