937 resultados para Rectangular protocol in field
Resumo:
Mestrado em Radiações Aplicadas às Tecnologias da Saúde. Área de especialização: Imagem Digital.
Resumo:
Neonatal anthropometry is an inexpensive, noninvasive and convenient tool for bedside evaluation, especially in sick and fragile neonates. Anthropometry can be used in neonates as a tool for several purposes: diagnosis of foetal malnutrition and prediction of early postnatal complications; postnatal assessment of growth, body composition and nutritional status; prediction of long-term complications including metabolic syndrome; assessment of dysmorphology; and estimation of body surface. However, in this age group anthropometry has been notorious for its inaccuracy and the main concern is to make validated indices available. Direct measurements, such as body weight, length and body circumferences are the most commonly used measurements for nutritional assessment in clinical practice and in field studies. Body weight is the most reliable anthropometric measurement and therefore is often used alone in the assessment of the nutritional status, despite not reflecting body composition. Derived indices from direct measurements have been proposed to improve the accuracy of anthropometry. Equations based on body weight and length, mid-arm circumference/head circumference ratio, and upper-arm cross-sectional areas are among the most used derived indices to assess nutritional status and body proportionality, even though these indices require further validation for the estimation of body composition in neonates.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Mestrado em Radioterapia
Resumo:
Neste trabalho estudou-se a implementação de um sistema de vigilância e alerta da qualidade da água de um recurso hídrico, para um possível caso de poluição. Em 25 de Agosto de 2008 foram derramadas 4 toneladas de ácido clorídrico acidentalmente para as águas do rio Febros. Este rio situa-se no concelho de Vila Nova de Gaia e é um pequeno afluente do rio Douro, tendo cerca de 14 km de extensão e tem a particularidade de atravessar o Parque Biológico de Gaia. A falta de uma rápida intervenção e da existência de um plano de ação levou a que parte da fauna e flora fosse destruída. Por este motivo realizou-se este estudo que se baseou na criação de um sistema de vigilância e alerta a ser implementado neste rio. A informação da hidrogeometria do rio e da capacidade de transporte e dispersão de poluentes é indispensável para o bom funcionamento deste sistema. O coeficiente de dispersão longitudinal é um parâmetro muito importante no estudo da qualidade da água. Recorreu-se à utilização da Rodamina WT como marcador, determinando assim a evolução da sua concentração ao longo do tempo e espaço. No cálculo do coeficiente de dispersão foi utilizado o modelo Transient Storage, que demonstrou ser um bom modelo de ajuste aproximando-se dos valores medidos em campo. Para três estações diferentes com distâncias de 290, 390 e 1100 metros do ponto de injeção, obtiveram-se valores de coeficiente de dispersão de 0,18, 0,15 e 0,39 m2/s respetivamente. Os valores do ajuste expressos sob a forma de coeficiente de correlação foram 0,988, 0,998 e 0,986, para a mesma ordem de estações. A constante de rearejamento do rio foi também determinada recorrendo ao método dos marcadores inertes, utilizando o propano como marcador gasoso. A constante determinada próximo de Casal Drijo, entre 2 estações de amostragem a 140 e 290 m do local de injeção, foi de 13,4 dia-1. Com os resultados do coeficiente de dispersão e da constante de rearejamento para além da velocidade e caudal da corrente do rio conseguir-se-á construir o modelo de simulação e previsão de um possível poluente. O sistema de vigilância a implementar sugere-se assim que seja construído por duas partes, uma de análise de evolução da nuvem de poluição e plano de ação outra de monitorização contínua e emissão de alerta. Após uma análise do investimento à implementação deste sistema chegou-se à conclusão que o valor de investimento é de 15.182,00 €.
Resumo:
The problem of providing a hybrid wired/wireless communications for factory automation systems is still an open issue, notwithstanding the fact that already there are some solutions. This paper describes the role of simulation tools on the validation and performance analysis of two wireless extensions for the PROFIBUS protocol. In one of them, the Intermediate Systems, which connect wired and wireless network segments, operate as repeaters. In the other one the Intermediate Systems operate as bridge. We also describe how the analytical analysis proposed for these kinds of networks can be used for the setting of some network parameters and for the guaranteeing real-time behaviour of the system. Additionally, we also compare the bridge-based solution simulation results with the analytical results.
Resumo:
The following article argues that recognition structures in work relations differ significantly in the sphere of paid work in contrast to unpaid work in private spheres. According to the systematic approach on recognition of Axel Honneth three different levels of recognition are identified: the interpersonal recognition, organisational recognition and societal recognition. Based on this framework it can be stated that recognition structures in the sphere of paid work and in private spheres differ very much. Whereas recognition in private spheres depends very much on personal relations, thus on the interpersonal level, recognition in employment relationships can be moreover built on organisational structures. Comparing recognition structures in both fields it becomes apparent, that recognition in field of employment can be characterised as much more concrete, comparable and measurable. Therefore, it can be concluded that the structural differences of recognition contribute to the high societal and individual importance of employment in contrast to unpaid work in private spheres.
Resumo:
O presente projeto enquadra-se na área das redes de sensores sem fios, onde o seu crescente desenvolvimento permite aplicar esta tecnologia em diversas áreas, como por exemplo, na monitorização ambiental, utilização militar, domótica, saúde, entre outras. Uma rede de sensores sem fios consiste em diversos nós dispersos num campo de aplicação onde procedem à recolha de dados do ambiente em que estão inseridos, como o valor de uma temperatura, humidade ou outra grandeza física, e os transmitem para uma estação base onde podem ser monitorizados. Tendo a área da saúde uma importância significativa, este projeto focalizou-se na mesma. O projeto apresentado nesta dissertação teve como principal objetivo o desenvolvimento de uma rede de sensores sem fios, em que dois nós procedam à aquisição da temperatura corporal de uma pessoa em dois locais distintos, para posterior envio da mesma para os restantes nós da rede, onde será apresentada em estações de monitorização. Este projeto foi desenvolvido baseado num recente protocolo de redes sem fios, nomeadamente o protocolo ANTTM. Assim sendo, em primeiro lugar, serão abordados neste relatório os objetivos e a contextualização deste projeto. Em seguida, será apresentada uma comparação sobre alguns aspetos de algumas tecnologias de comunicações sem fios, nomeadamente o ZigBee, Bluetooth e ANT. Devido ao fato da tecnologia ANT ser a escolhida para o desenvolvimento deste projeto, será também apresentado um estudo mais detalhado sobre o mesmo. Depois, será apresentado o desenvolvimento e implementações efetuadas, e por último serão apresentadas as conclusões técnicas e pessoais que este projeto permitiu obter.
Resumo:
Mathematical models and statistical analysis are key instruments in soil science scientific research as they can describe and/or predict the current state of a soil system. These tools allow us to explore the behavior of soil related processes and properties as well as to generate new hypotheses for future experimentation. A good model and analysis of soil properties variations, that permit us to extract suitable conclusions and estimating spatially correlated variables at unsampled locations, is clearly dependent on the amount and quality of data and of the robustness techniques and estimators. On the other hand, the quality of data is obviously dependent from a competent data collection procedure and from a capable laboratory analytical work. Following the standard soil sampling protocols available, soil samples should be collected according to key points such as a convenient spatial scale, landscape homogeneity (or non-homogeneity), land color, soil texture, land slope, land solar exposition. Obtaining good quality data from forest soils is predictably expensive as it is labor intensive and demands many manpower and equipment both in field work and in laboratory analysis. Also, the sampling collection scheme that should be used on a data collection procedure in forest field is not simple to design as the sampling strategies chosen are strongly dependent on soil taxonomy. In fact, a sampling grid will not be able to be followed if rocks at the predicted collecting depth are found, or no soil at all is found, or large trees bar the soil collection. Considering this, a proficient design of a soil data sampling campaign in forest field is not always a simple process and sometimes represents a truly huge challenge. In this work, we present some difficulties that have occurred during two experiments on forest soil that were conducted in order to study the spatial variation of some soil physical-chemical properties. Two different sampling protocols were considered for monitoring two types of forest soils located in NW Portugal: umbric regosol and lithosol. Two different equipments for sampling collection were also used: a manual auger and a shovel. Both scenarios were analyzed and the results achieved have allowed us to consider that monitoring forest soil in order to do some mathematical and statistical investigations needs a sampling procedure to data collection compatible to established protocols but a pre-defined grid assumption often fail when the variability of the soil property is not uniform in space. In this case, sampling grid should be conveniently adapted from one part of the landscape to another and this fact should be taken into consideration of a mathematical procedure.
Resumo:
A new serological test, the gelatin particle agglutination test (GPAT), was used for the serodiagnosis of schistosomiasis mansoni. This technique showed the sensitivity (90.6%) and specificity (97.8%) close to those of enzyme-linked immunosorbent assay. The GPAT can be easily and rapidly performed without specialized equipment, by using lyophilized antigen-coated gelatin particles. The test also seems to be useful for mass screening of Schistosoma infection in field conditions.
Resumo:
Antibodies to a number of parasite antigens are found in schistosomiasis patients, and antibodies to early developmental stages were demonstrated to be efficient immunologic markers for the diagnosis of schistosomiasis. In the present study, decay patterns of IgM and IgG antibodies against cercariae and schistosomula were investigated, in comparison to antibodies against worms and eggs in schistosomiasis patients after chemotherapy, for an investigation of seroepidemiologic aspects. Data obtained in the study of 359 serum samples from patients with Schistosoma mansoni infection, noninfected individuals, and patients followed-up for a period of 12 to 15 months after treatment provided the basis to postulate a general pattern for the kinetics of antibody decay. Before treatment, the antibody pattern was represented by a unimodal curve, which shifted to a bimodal curve after treatment, and ended with a unimodal curve similar to that for the noninfected group. Different types of antibodies were classified into four categories according to their decay features, and anti-schistosomulum IgM was classified into the moderate-decay caterogy, whereas other antibodies to early parasite stages were classified into the slow-decay category. The present methodology permits the identification of the most suitable antibodies to be detected in field control programs for schistosomiasis or other parasitoses
Resumo:
A monitorização ambiental é essencial para a tomada de decisões tanto na ciência como na indústria. Em particular, uma vez que a água é essencial à vida e a superfície da Terra é composta principalmente por água, a monitorização do clima e dos parâmetros relacionados com a água em ecossistemas sensíveis, tais como oceanos, lagoas, rios e lagos, é de extrema importância. Um dos métodos mais comuns para monitorar a água é implantar bóias. O presente trabalho está integrado num projeto mais amplo, com o objetivo de projectar e desenvolver uma bóia autónoma para a investigação científica com dois modos de funcionamento: (i) monitorização ambiental ; e (ii) baliza ativa de regata. Assim, a bóia tem duas aplicações principais: a coleta e armazenamento de dados e a assistência a regatas de veleiros autónomos. O projeto arrancou há dois anos com um grupo de quatro estudantes internacionais. Eles projetaram e construíram a estrutura física, compraram e montaram o sistema de ancoragem da bóia e escolherem a maioria dos componentes electrónicos para o sistema geral de controlo e medição. Este ano, durante o primeiro semestre, dois estudantes belgas - Jeroen Vervenne e Hendrick Verschelde – trabalharam nos subsistemas de recolha e armazenamento de dados (unidade de controlo escrava) e de telemetria e configuração (unidade de controlo mestre) assim como definiram o protocolo de comunicação da aplicação. O trabalho desta tese continua o desenvolvimento do subsistema de telemetria e configuração. Este subsistema _e responsável pela configuração do modo de funcionamento e dos sensores assim como pela comunicação com a estacão de base (controlo ambiental), barcos (baliza ativa de regata) e com o subsistema de recolha e armazenamento de dados. O desenvolvimento do subsistema de recolha e armazenamento de dados, que coleta e armazena num cartão SD os dados dos sensores selecionados, prossegue com outro estudante belga - Mathias van Flieberge. O objetivo desta tese é, por um lado, implementar o subsistema de telemetria e de configuração na unidade de controle mestre e, por outro lado, refinar e implementar, conjuntamente com Mathias van Flieberge, o protocolo de nível de aplicação projetado. Em particular, a unidade de controlo mestre deve processar e atribuir prioridades às mensagens recebidas da estacão base, solicitar dados à unidade de controlo escrava e difundir mensagens com informação de posição e condições de vento e água no modo de regata. Enquanto que a comunicação entre a unidade de controlo mestre e a estacão base e a unidade de controlo mestre e os barcos é sem fios, a unidade de controlo mestre e a unidade de controlo escrava comunicam através de uma ligação série. A bóia tem atualmente duas limitações: (i) a carga máxima é de 40 kg; e (ii) apenas pode ser utilizada em rios ou próximo da costa dada à limitação de distância imposta pela técnica de comunicação sem fios escolhida.
Resumo:
Introdução: A acumulação de gordura na região abdominal acarreta um maior risco para a saúde. Objetivo(s): Analisar o efeito de um protocolo de uma sessão de exercício físico aeróbio associada à eletrolipólise no tecido adiposo da região abdominal nos valores do consumo e proporção dos substratos energéticos. É ainda objetivo avaliar as diferenças no consumo e proporção dos substratos energéticos, com o mesmo protocolo, no sexo feminino e no sexo masculino. Métodos: 38 participantes foram distribuídos aleatoriamente por dois grupos, o grupo experimental (9 feminino e 9 masculino) e o grupo placebo (11 feminino e 9 masculino). Ambos os grupos foram avaliados através das medidas antropométricas e foram sujeitos aos dois protocolos do estudo, o de microcorrente com aplicação 2 frequências (25 e 10Hz), 20 minutos cada, e o de exercício aeróbio a 45-55% frequência cardíaca de reserva. Contudo, no grupo placebo a microcorrente foi realizada sem intensidade. Para obtenção dos valores do consumo e proporção dos substratos foi utilizado o K4b2 durante o exercício físico. Resultados: Não se verificaram diferenças significativas nas quantidades de ácidos gordos, glucose e no quociente respiratório entre os grupos (ρ> 0,05). No entanto, parece haver uma tendência para um maior consumo de ácidos gordos após a aplicação da microcorrente durante o exercício físico. Conclusão: Os resultados deste estudo indicam que uma sessão de eletrolipólise associada ao exercício físico aeróbio não parece ser suficiente para influenciar a quantidade do consumo e a proporção dos substratos energéticos numa amostra de indivíduos jovens de ambos os sexos.
Resumo:
As alterações climáticas são atualmente reconhecidas como uma das mais relevantes ameaças ambientais, sociais e económicas. A resposta a este problema tem-se traduzido na aplicação de um conjunto de legislação e práticas, com o objetivo de promover uma redução significativa das emissões de gases com efeito de estufa. Entre outros, os gases fluorados são dos mais relevantes gases com efeito de estufa, conforme identificados no Protocolo de Quioto. No enquadramento legal em vigor a certificação de técnicos e empresas, assim como certificação de ferramentas para o manuseamento de gases fluorados, sofreu, desde 2011, uma profunda alteração, com impacto nos procedimentos de manutenção existentes até essa data, na atividade de empresas prestadoras de serviços de manutenção e na atuação dos proprietários de edifícios civis e industriais com equipamentos que contêm gases fluorados. Esta tese tem como objetivo evidenciar as ações que as empresas prestadores de serviços necessitam executar para a sua certificação, assim como informar os proprietários de edifícios civis ou industriais, sobre as diferentes vertentes que têm à sua disposição, em termos de gestão da manutenção, de forma a garantir o cumprimento da legislação em vigor nas suas instalações e a gestão de ativos físicos que contêm gases fluorados, tais como equipamentos e instalações de aquecimento, ventilação, ar condicionado e refrigeração. Foi efetuada uma pesquisa aprofundada sobre os requisitos legais e técnicos necessários para a cerificação das empresas que atuam neste sector. Um caso de estudo foi realizado e os resultados apresentados sobre todo o processo de certificação de uma empresa do setor do ar condicionado e refrigeração, para poder prestar serviços em equipamentos ou sistemas que contenham gases fluorados com efeito de estufa.
Resumo:
OBJECTIVE: We set out to evaluate whether changes in N-terminal pro-brain natriuretic peptide (proBNP) can predict changes in functional capacity, as determined by cardiopulmonary exercise testing (CPET), in patients with chronic heart failure (CHF) due to dilated cardiomyopathy (DCM). METHODS: We studied 37 patients with CHF due to DCM, 81% non-ischemic, 28 male, who performed symptom-limited treadmill CPET, with the modified Bruce protocol, in two consecutive evaluations, with determination of proBNP after 10 minutes rest prior to CPET. The time between evaluations was 9.6+/-5.5 months, and age at first evaluation was 41.1+/-13.9 years (21 to 67). RESULTS IN THE FIRST AND SECOND EVALUATIONS RESPECTIVELY WERE: NYHA functional class >II 51% and 16% (p<0.001), sinus rhythm 89% and 86.5% (NS), left ventricular ejection fraction 24.9+/-8.9% and 26.6+/-8.6% (NS), creatinine 1.03+/-0.25 and 1.09+/-0.42 mg/dl (NS), taking ACE inhibitors or ARBs 94.5% and 100% (NS), beta-blockers 73% and 97.3% (p<0.001), and spironolactone 89% and 89% (NS). We analyzed the absolute and percentage variation (AV and PV) in peak oxygen uptake (pVO2--ml/kg/min) and proBNP (pg/ml) between the two evaluations. RESULTS: (1) pVO2 AV: -17.4 to 15.2 (1.9+/-5.7); pVO2 PV: -56.1 to 84% (11.0+/-25.2); proBNP AV: -12850 to 5983 (-778.4+/-3332.5); proBNP PV: -99.0 to 379.5% (-8.8+/-86.3); (2) The correlations obtained--r value and p value [r (p)]--are shown in the table below; (3) We considered that a coefficient of variation of pVO2 PV of >10% represented a significant change in functional capacity. On ROC curve analysis, a proBNP PV value of 28% showed 80% sensitivity and 79% specificity for pVO2 PV of >10% (AUC=0.876, p=0.01, 95% CI 0.75 to 0.99). CONCLUSIONS: In patients with CHF due to DCM, changes in proBNP values correlate with variations in pVO2, as assessed by CPET. However, our results suggest that only a proBNP PV of >28% predicts a significant change in functional capacity.