889 resultados para Public buildings -- Energy consumption
Resumo:
The computational and cooling power demands of enterprise servers are increasing at an unsustainable rate. Understanding the relationship between computational power, temperature, leakage, and cooling power is crucial to enable energy-efficient operation at the server and data center levels. This paper develops empirical models to estimate the contributions of static and dynamic power consumption in enterprise servers for a wide range of workloads, and analyzes the interactions between temperature, leakage, and cooling power for various workload allocation policies. We propose a cooling management policy that minimizes the server energy consumption by setting the optimum fan speed during runtime. Our experimental results on a presently shipping enterprise server demonstrate that including leakage awareness in workload and cooling management provides additional energy savings without any impact on performance.
Design and Simulation of Deep Nanometer SRAM Cells under Energy, Mismatch, and Radiation Constraints
Resumo:
La fiabilidad está pasando a ser el principal problema de los circuitos integrados según la tecnología desciende por debajo de los 22nm. Pequeñas imperfecciones en la fabricación de los dispositivos dan lugar ahora a importantes diferencias aleatorias en sus características eléctricas, que han de ser tenidas en cuenta durante la fase de diseño. Los nuevos procesos y materiales requeridos para la fabricación de dispositivos de dimensiones tan reducidas están dando lugar a diferentes efectos que resultan finalmente en un incremento del consumo estático, o una mayor vulnerabilidad frente a radiación. Las memorias SRAM son ya la parte más vulnerable de un sistema electrónico, no solo por representar más de la mitad del área de los SoCs y microprocesadores actuales, sino también porque las variaciones de proceso les afectan de forma crítica, donde el fallo de una única célula afecta a la memoria entera. Esta tesis aborda los diferentes retos que presenta el diseño de memorias SRAM en las tecnologías más pequeñas. En un escenario de aumento de la variabilidad, se consideran problemas como el consumo de energía, el diseño teniendo en cuenta efectos de la tecnología a bajo nivel o el endurecimiento frente a radiación. En primer lugar, dado el aumento de la variabilidad de los dispositivos pertenecientes a los nodos tecnológicos más pequeños, así como a la aparición de nuevas fuentes de variabilidad por la inclusión de nuevos dispositivos y la reducción de sus dimensiones, la precisión del modelado de dicha variabilidad es crucial. Se propone en la tesis extender el método de inyectores, que modela la variabilidad a nivel de circuito, abstrayendo sus causas físicas, añadiendo dos nuevas fuentes para modelar la pendiente sub-umbral y el DIBL, de creciente importancia en la tecnología FinFET. Los dos nuevos inyectores propuestos incrementan la exactitud de figuras de mérito a diferentes niveles de abstracción del diseño electrónico: a nivel de transistor, de puerta y de circuito. El error cuadrático medio al simular métricas de estabilidad y prestaciones de células SRAM se reduce un mínimo de 1,5 veces y hasta un máximo de 7,5 a la vez que la estimación de la probabilidad de fallo se mejora en varios ordenes de magnitud. El diseño para bajo consumo es una de las principales aplicaciones actuales dada la creciente importancia de los dispositivos móviles dependientes de baterías. Es igualmente necesario debido a las importantes densidades de potencia en los sistemas actuales, con el fin de reducir su disipación térmica y sus consecuencias en cuanto al envejecimiento. El método tradicional de reducir la tensión de alimentación para reducir el consumo es problemático en el caso de las memorias SRAM dado el creciente impacto de la variabilidad a bajas tensiones. Se propone el diseño de una célula que usa valores negativos en la bit-line para reducir los fallos de escritura según se reduce la tensión de alimentación principal. A pesar de usar una segunda fuente de alimentación para la tensión negativa en la bit-line, el diseño propuesto consigue reducir el consumo hasta en un 20 % comparado con una célula convencional. Una nueva métrica, el hold trip point se ha propuesto para prevenir nuevos tipos de fallo debidos al uso de tensiones negativas, así como un método alternativo para estimar la velocidad de lectura, reduciendo el número de simulaciones necesarias. Según continúa la reducción del tamaño de los dispositivos electrónicos, se incluyen nuevos mecanismos que permiten facilitar el proceso de fabricación, o alcanzar las prestaciones requeridas para cada nueva generación tecnológica. Se puede citar como ejemplo el estrés compresivo o extensivo aplicado a los fins en tecnologías FinFET, que altera la movilidad de los transistores fabricados a partir de dichos fins. Los efectos de estos mecanismos dependen mucho del layout, la posición de unos transistores afecta a los transistores colindantes y pudiendo ser el efecto diferente en diferentes tipos de transistores. Se propone el uso de una célula SRAM complementaria que utiliza dispositivos pMOS en los transistores de paso, así reduciendo la longitud de los fins de los transistores nMOS y alargando los de los pMOS, extendiéndolos a las células vecinas y hasta los límites de la matriz de células. Considerando los efectos del STI y estresores de SiGe, el diseño propuesto mejora los dos tipos de transistores, mejorando las prestaciones de la célula SRAM complementaria en más de un 10% para una misma probabilidad de fallo y un mismo consumo estático, sin que se requiera aumentar el área. Finalmente, la radiación ha sido un problema recurrente en la electrónica para aplicaciones espaciales, pero la reducción de las corrientes y tensiones de los dispositivos actuales los está volviendo vulnerables al ruido generado por radiación, incluso a nivel de suelo. Pese a que tecnologías como SOI o FinFET reducen la cantidad de energía colectada por el circuito durante el impacto de una partícula, las importantes variaciones de proceso en los nodos más pequeños va a afectar su inmunidad frente a la radiación. Se demuestra que los errores inducidos por radiación pueden aumentar hasta en un 40 % en el nodo de 7nm cuando se consideran las variaciones de proceso, comparado con el caso nominal. Este incremento es de una magnitud mayor que la mejora obtenida mediante el diseño de células de memoria específicamente endurecidas frente a radiación, sugiriendo que la reducción de la variabilidad representaría una mayor mejora. ABSTRACT Reliability is becoming the main concern on integrated circuit as the technology goes beyond 22nm. Small imperfections in the device manufacturing result now in important random differences of the devices at electrical level which must be dealt with during the design. New processes and materials, required to allow the fabrication of the extremely short devices, are making new effects appear resulting ultimately on increased static power consumption, or higher vulnerability to radiation SRAMs have become the most vulnerable part of electronic systems, not only they account for more than half of the chip area of nowadays SoCs and microprocessors, but they are critical as soon as different variation sources are regarded, with failures in a single cell making the whole memory fail. This thesis addresses the different challenges that SRAM design has in the smallest technologies. In a common scenario of increasing variability, issues like energy consumption, design aware of the technology and radiation hardening are considered. First, given the increasing magnitude of device variability in the smallest nodes, as well as new sources of variability appearing as a consequence of new devices and shortened lengths, an accurate modeling of the variability is crucial. We propose to extend the injectors method that models variability at circuit level, abstracting its physical sources, to better model sub-threshold slope and drain induced barrier lowering that are gaining importance in FinFET technology. The two new proposed injectors bring an increased accuracy of figures of merit at different abstraction levels of electronic design, at transistor, gate and circuit levels. The mean square error estimating performance and stability metrics of SRAM cells is reduced by at least 1.5 and up to 7.5 while the yield estimation is improved by orders of magnitude. Low power design is a major constraint given the high-growing market of mobile devices that run on battery. It is also relevant because of the increased power densities of nowadays systems, in order to reduce the thermal dissipation and its impact on aging. The traditional approach of reducing the voltage to lower the energy consumption if challenging in the case of SRAMs given the increased impact of process variations at low voltage supplies. We propose a cell design that makes use of negative bit-line write-assist to overcome write failures as the main supply voltage is lowered. Despite using a second power source for the negative bit-line, the design achieves an energy reduction up to 20% compared to a conventional cell. A new metric, the hold trip point has been introduced to deal with new sources of failures to cells using a negative bit-line voltage, as well as an alternative method to estimate cell speed, requiring less simulations. With the continuous reduction of device sizes, new mechanisms need to be included to ease the fabrication process and to meet the performance targets of the successive nodes. As example we can consider the compressive or tensile strains included in FinFET technology, that alter the mobility of the transistors made out of the concerned fins. The effects of these mechanisms are very dependent on the layout, with transistor being affected by their neighbors, and different types of transistors being affected in a different way. We propose to use complementary SRAM cells with pMOS pass-gates in order to reduce the fin length of nMOS devices and achieve long uncut fins for the pMOS devices when the cell is included in its corresponding array. Once Shallow Trench isolation and SiGe stressors are considered the proposed design improves both kinds of transistor, boosting the performance of complementary SRAM cells by more than 10% for a same failure probability and static power consumption, with no area overhead. While radiation has been a traditional concern in space electronics, the small currents and voltages used in the latest nodes are making them more vulnerable to radiation-induced transient noise, even at ground level. Even if SOI or FinFET technologies reduce the amount of energy transferred from the striking particle to the circuit, the important process variation that the smallest nodes will present will affect their radiation hardening capabilities. We demonstrate that process variations can increase the radiation-induced error rate by up to 40% in the 7nm node compared to the nominal case. This increase is higher than the improvement achieved by radiation-hardened cells suggesting that the reduction of process variations would bring a higher improvement.
Resumo:
El actual contexto de fabricación, con incrementos en los precios de la energía, una creciente preocupación medioambiental y cambios continuos en los comportamientos de los consumidores, fomenta que los responsables prioricen la fabricación respetuosa con el medioambiente. El paradigma del Internet de las Cosas (IoT) promete incrementar la visibilidad y la atención prestada al consumo de energía gracias tanto a sensores como a medidores inteligentes en los niveles de máquina y de línea de producción. En consecuencia es posible y sencillo obtener datos de consumo de energía en tiempo real proveniente de los procesos de fabricación, pero además es posible analizarlos para incrementar su importancia en la toma de decisiones. Esta tesis pretende investigar cómo utilizar la adopción del Internet de las Cosas en el nivel de planta de producción, en procesos discretos, para incrementar la capacidad de uso de la información proveniente tanto de la energía como de la eficiencia energética. Para alcanzar este objetivo general, la investigación se ha dividido en cuatro sub-objetivos y la misma se ha desarrollado a lo largo de cuatro fases principales (en adelante estudios). El primer estudio de esta tesis, que se apoya sobre una revisión bibliográfica comprehensiva y sobre las aportaciones de expertos, define prácticas de gestión de la producción que son energéticamente eficientes y que se apoyan de un modo preeminente en la tecnología IoT. Este primer estudio también detalla los beneficios esperables al adoptar estas prácticas de gestión. Además, propugna un marco de referencia para permitir la integración de los datos que sobre el consumo energético se obtienen en el marco de las plataformas y sistemas de información de la compañía. Esto se lleva a cabo con el objetivo último de remarcar cómo estos datos pueden ser utilizados para apalancar decisiones en los niveles de procesos tanto tácticos como operativos. Segundo, considerando los precios de la energía como variables en el mercado intradiario y la disponibilidad de información detallada sobre el estado de las máquinas desde el punto de vista de consumo energético, el segundo estudio propone un modelo matemático para minimizar los costes del consumo de energía para la programación de asignaciones de una única máquina que deba atender a varios procesos de producción. Este modelo permite la toma de decisiones en el nivel de máquina para determinar los instantes de lanzamiento de cada trabajo de producción, los tiempos muertos, cuándo la máquina debe ser puesta en un estado de apagada, el momento adecuado para rearrancar, y para pararse, etc. Así, este modelo habilita al responsable de producción de implementar el esquema de producción menos costoso para cada turno de producción. En el tercer estudio esta investigación proporciona una metodología para ayudar a los responsables a implementar IoT en el nivel de los sistemas productivos. Se incluye un análisis del estado en que se encuentran los sistemas de gestión de energía y de producción en la factoría, así como también se proporcionan recomendaciones sobre procedimientos para implementar IoT para capturar y analizar los datos de consumo. Esta metodología ha sido validada en un estudio piloto, donde algunos indicadores clave de rendimiento (KPIs) han sido empleados para determinar la eficiencia energética. En el cuarto estudio el objetivo es introducir una vía para obtener visibilidad y relevancia a diferentes niveles de la energía consumida en los procesos de producción. El método propuesto permite que las factorías con procesos de producción discretos puedan determinar la energía consumida, el CO2 emitido o el coste de la energía consumida ya sea en cualquiera de los niveles: operación, producto o la orden de fabricación completa, siempre considerando las diferentes fuentes de energía y las fluctuaciones en los precios de la misma. Los resultados muestran que decisiones y prácticas de gestión para conseguir sistemas de producción energéticamente eficientes son posibles en virtud del Internet de las Cosas. También, con los resultados de esta tesis los responsables de la gestión energética en las compañías pueden plantearse una aproximación a la utilización del IoT desde un punto de vista de la obtención de beneficios, abordando aquellas prácticas de gestión energética que se encuentran más próximas al nivel de madurez de la factoría, a sus objetivos, al tipo de producción que desarrolla, etc. Así mismo esta tesis muestra que es posible obtener reducciones significativas de coste simplemente evitando los períodos de pico diario en el precio de la misma. Además la tesis permite identificar cómo el nivel de monitorización del consumo energético (es decir al nivel de máquina), el intervalo temporal, y el nivel del análisis de los datos son factores determinantes a la hora de localizar oportunidades para mejorar la eficiencia energética. Adicionalmente, la integración de datos de consumo energético en tiempo real con datos de producción (cuando existen altos niveles de estandarización en los procesos productivos y sus datos) es esencial para permitir que las factorías detallen la energía efectivamente consumida, su coste y CO2 emitido durante la producción de un producto o componente. Esto permite obtener una valiosa información a los gestores en el nivel decisor de la factoría así como a los consumidores y reguladores. ABSTRACT In today‘s manufacturing scenario, rising energy prices, increasing ecological awareness, and changing consumer behaviors are driving decision makers to prioritize green manufacturing. The Internet of Things (IoT) paradigm promises to increase the visibility and awareness of energy consumption, thanks to smart sensors and smart meters at the machine and production line level. Consequently, real-time energy consumption data from the manufacturing processes can be easily collected and then analyzed, to improve energy-aware decision-making. This thesis aims to investigate how to utilize the adoption of the Internet of Things at shop floor level to increase energy–awareness and the energy efficiency of discrete production processes. In order to achieve the main research goal, the research is divided into four sub-objectives, and is accomplished during four main phases (i.e., studies). In the first study, by relying on a comprehensive literature review and on experts‘ insights, the thesis defines energy-efficient production management practices that are enhanced and enabled by IoT technology. The first study also explains the benefits that can be obtained by adopting such management practices. Furthermore, it presents a framework to support the integration of gathered energy data into a company‘s information technology tools and platforms, which is done with the ultimate goal of highlighting how operational and tactical decision-making processes could leverage such data in order to improve energy efficiency. Considering the variable energy prices in one day, along with the availability of detailed machine status energy data, the second study proposes a mathematical model to minimize energy consumption costs for single machine production scheduling during production processes. This model works by making decisions at the machine level to determine the launch times for job processing, idle time, when the machine must be shut down, ―turning on‖ time, and ―turning off‖ time. This model enables the operations manager to implement the least expensive production schedule during a production shift. In the third study, the research provides a methodology to help managers implement the IoT at the production system level; it includes an analysis of current energy management and production systems at the factory, and recommends procedures for implementing the IoT to collect and analyze energy data. The methodology has been validated by a pilot study, where energy KPIs have been used to evaluate energy efficiency. In the fourth study, the goal is to introduce a way to achieve multi-level awareness of the energy consumed during production processes. The proposed method enables discrete factories to specify energy consumption, CO2 emissions, and the cost of the energy consumed at operation, production and order levels, while considering energy sources and fluctuations in energy prices. The results show that energy-efficient production management practices and decisions can be enhanced and enabled by the IoT. With the outcomes of the thesis, energy managers can approach the IoT adoption in a benefit-driven way, by addressing energy management practices that are close to the maturity level of the factory, target, production type, etc. The thesis also shows that significant reductions in energy costs can be achieved by avoiding high-energy price periods in a day. Furthermore, the thesis determines the level of monitoring energy consumption (i.e., machine level), the interval time, and the level of energy data analysis, which are all important factors involved in finding opportunities to improve energy efficiency. Eventually, integrating real-time energy data with production data (when there are high levels of production process standardization data) is essential to enable factories to specify the amount and cost of energy consumed, as well as the CO2 emitted while producing a product, providing valuable information to decision makers at the factory level as well as to consumers and regulators.
Resumo:
The main goal of the cofounded by the European Commission LIFE Project, New4Old (LIFE10 ENV/ES/439), is to define the most appropriate method and the best available practice in social housing rehabilitation with energy and environmental sustainability criteria, as well as to apply innovative technologies in the fight against climate change through an efficient use of resources and energy. The institutions involved in the Project are the Technological Centre AITEMIN, Madrid Polytechnic University (UPM), Portugal Technological Centre for Ceramics and Glass (CTCV) and the Zaragoza City Housing Society (SMZV). The demonstrator project consists in the energy rehabilitation of a rental social housing building located in Zaragoza?s historic quarter, according to the conclusions and strategies developed for the LIFE project. In actions taken in households of this nature passive design strategies are essential due to the limited income of owners, who often cannot afford energy bills. Therefore, the proposed actions will help improve the building?s passive performance and reach a higher thermal comfort, without increasing the economic cost linked to energy consumption.
Resumo:
Recent research has shown large differences between the expected and the actual energy consumption in buildings. The differences have been attributed partially, to the assumptions made during the design phase of buildings when simulation methods are employed. More accurate occupancy profiles on building operation could help to carry out more precise building performance calculations. This study focuses on the post-occupancy evaluation of two apartments, one renovated and one non renovated, in Madrid within the same building complex. The aim of this paper is to present an application of the mixed-methods methodology (Creswell, 2007) to assess thermal comfort and occupancy practices used in the case studies, and to discuss the shortcomings and opportunities associated with it. The mixed-methods methodology offers strategies for integrating qualitative and quantitative methods to investigate complex phenomena. This approach is expected to contribute to the growing knowledge of occupants’ behaviour and building performance by explaining the differences observed between energy consumption and thermal comfort in relation to people’s saving and comfort practices and the related experiences, preferences and values.
Resumo:
Hoy en día, el proceso de un proyecto sostenible persigue realizar edificios de elevadas prestaciones que son, energéticamente eficientes, saludables y económicamente viables utilizando sabiamente recursos renovables para minimizar el impacto sobre el medio ambiente reduciendo, en lo posible, la demanda de energía, lo que se ha convertido, en la última década, en una prioridad. La Directiva 2002/91/CE "Eficiencia Energética de los Edificios" (y actualizaciones posteriores) ha establecido el marco regulatorio general para el cálculo de los requerimientos energéticos mínimos. Desde esa fecha, el objetivo de cumplir con las nuevas directivas y protocolos ha conducido las políticas energéticas de los distintos países en la misma dirección, centrándose en la necesidad de aumentar la eficiencia energética en los edificios, la adopción de medidas para reducir el consumo, y el fomento de la generación de energía a través de fuentes renovables. Los edificios de energía nula o casi nula (ZEB, Zero Energy Buildings ó NZEB, Net Zero Energy Buildings) deberán convertirse en un estándar de la construcción en Europa y con el fin de equilibrar el consumo de energía, además de reducirlo al mínimo, los edificios necesariamente deberán ser autoproductores de energía. Por esta razón, la envolvente del edifico y en particular las fachadas son importantes para el logro de estos objetivos y la tecnología fotovoltaica puede tener un papel preponderante en este reto. Para promover el uso de la tecnología fotovoltaica, diferentes programas de investigación internacionales fomentan y apoyan soluciones para favorecer la integración completa de éstos sistemas como elementos arquitectónicos y constructivos, los sistemas BIPV (Building Integrated Photovoltaic), sobre todo considerando el próximo futuro hacia edificios NZEB. Se ha constatado en este estudio que todavía hay una falta de información útil disponible sobre los sistemas BIPV, a pesar de que el mercado ofrece una interesante gama de soluciones, en algunos aspectos comparables a los sistemas tradicionales de construcción. Pero por el momento, la falta estandarización y de una regulación armonizada, además de la falta de información en las hojas de datos técnicos (todavía no comparables con las mismas que están disponibles para los materiales de construcción), hacen difícil evaluar adecuadamente la conveniencia y factibilidad de utilizar los componentes BIPV como parte integrante de la envolvente del edificio. Organizaciones internacionales están trabajando para establecer las normas adecuadas y procedimientos de prueba y ensayo para comprobar la seguridad, viabilidad y fiabilidad estos sistemas. Sin embargo, hoy en día, no hay reglas específicas para la evaluación y caracterización completa de un componente fotovoltaico de integración arquitectónica de acuerdo con el Reglamento Europeo de Productos de la Construcción, CPR 305/2011. Los productos BIPV, como elementos de construcción, deben cumplir con diferentes aspectos prácticos como resistencia mecánica y la estabilidad; integridad estructural; seguridad de utilización; protección contra el clima (lluvia, nieve, viento, granizo), el fuego y el ruido, aspectos que se han convertido en requisitos esenciales, en la perspectiva de obtener productos ambientalmente sostenibles, saludables, eficientes energéticamente y económicamente asequibles. Por lo tanto, el módulo / sistema BIPV se convierte en una parte multifuncional del edificio no sólo para ser física y técnicamente "integrado", además de ser una oportunidad innovadora del diseño. Las normas IEC, de uso común en Europa para certificar módulos fotovoltaicos -IEC 61215 e IEC 61646 cualificación de diseño y homologación del tipo para módulos fotovoltaicos de uso terrestre, respectivamente para módulos fotovoltaicos de silicio cristalino y de lámina delgada- atestan únicamente la potencia del módulo fotovoltaico y dan fe de su fiabilidad por un período de tiempo definido, certificando una disminución de potencia dentro de unos límites. Existe también un estándar, en parte en desarrollo, el IEC 61853 (“Ensayos de rendimiento de módulos fotovoltaicos y evaluación energética") cuyo objetivo es la búsqueda de procedimientos y metodologías de prueba apropiados para calcular el rendimiento energético de los módulos fotovoltaicos en diferentes condiciones climáticas. Sin embargo, no existen ensayos normalizados en las condiciones específicas de la instalación (p. ej. sistemas BIPV de fachada). Eso significa que es imposible conocer las efectivas prestaciones de estos sistemas y las condiciones ambientales que se generan en el interior del edificio. La potencia nominal de pico Wp, de un módulo fotovoltaico identifica la máxima potencia eléctrica que éste puede generar bajo condiciones estándares de medida (STC: irradición 1000 W/m2, 25 °C de temperatura del módulo y distribución espectral, AM 1,5) caracterizando eléctricamente el módulo PV en condiciones específicas con el fin de poder comparar los diferentes módulos y tecnologías. El vatio pico (Wp por su abreviatura en inglés) es la medida de la potencia nominal del módulo PV y no es suficiente para evaluar el comportamiento y producción del panel en términos de vatios hora en las diferentes condiciones de operación, y tampoco permite predecir con convicción la eficiencia y el comportamiento energético de un determinado módulo en condiciones ambientales y de instalación reales. Un adecuado elemento de integración arquitectónica de fachada, por ejemplo, debería tener en cuenta propiedades térmicas y de aislamiento, factores como la transparencia para permitir ganancias solares o un buen control solar si es necesario, aspectos vinculados y dependientes en gran medida de las condiciones climáticas y del nivel de confort requerido en el edificio, lo que implica una necesidad de adaptación a cada contexto específico para obtener el mejor resultado. Sin embargo, la influencia en condiciones reales de operación de las diferentes soluciones fotovoltaicas de integración, en el consumo de energía del edificio no es fácil de evaluar. Los aspectos térmicos del interior del ambiente o de iluminación, al utilizar módulos BIPV semitransparentes por ejemplo, son aún desconocidos. Como se dijo antes, la utilización de componentes de integración arquitectónica fotovoltaicos y el uso de energía renovable ya es un hecho para producir energía limpia, pero también sería importante conocer su posible contribución para mejorar el confort y la salud de los ocupantes del edificio. Aspectos como el confort, la protección o transmisión de luz natural, el aislamiento térmico, el consumo energético o la generación de energía son aspectos que suelen considerarse independientemente, mientras que todos juntos contribuyen, sin embargo, al balance energético global del edificio. Además, la necesidad de dar prioridad a una orientación determinada del edificio, para alcanzar el mayor beneficio de la producción de energía eléctrica o térmica, en el caso de sistemas activos y pasivos, respectivamente, podría hacer estos últimos incompatibles, pero no necesariamente. Se necesita un enfoque holístico que permita arquitectos e ingenieros implementar sistemas tecnológicos que trabajen en sinergia. Se ha planteado por ello un nuevo concepto: "C-BIPV, elemento fotovoltaico consciente integrado", esto significa necesariamente conocer los efectos positivos o negativos (en términos de confort y de energía) en condiciones reales de funcionamiento e instalación. Propósito de la tesis, método y resultados Los sistemas fotovoltaicos integrados en fachada son a menudo soluciones de vidrio fácilmente integrables, ya que por lo general están hechos a medida. Estos componentes BIPV semitransparentes, integrados en el cerramiento proporcionan iluminación natural y también sombra, lo que evita el sobrecalentamiento en los momentos de excesivo calor, aunque como componente estático, asimismo evitan las posibles contribuciones pasivas de ganancias solares en los meses fríos. Además, la temperatura del módulo varía considerablemente en ciertas circunstancias influenciada por la tecnología fotovoltaica instalada, la radiación solar, el sistema de montaje, la tipología de instalación, falta de ventilación, etc. Este factor, puede suponer un aumento adicional de la carga térmica en el edificio, altamente variable y difícil de cuantificar. Se necesitan, en relación con esto, más conocimientos sobre el confort ambiental interior en los edificios que utilizan tecnologías fotovoltaicas integradas, para abrir de ese modo, una nueva perspectiva de la investigación. Con este fin, se ha diseñado, proyectado y construido una instalación de pruebas al aire libre, el BIPV Env-lab "BIPV Test Laboratory", para la caracterización integral de los diferentes módulos semitransparentes BIPV. Se han definido también el método y el protocolo de ensayos de caracterización en el contexto de un edificio y en condiciones climáticas y de funcionamiento reales. Esto ha sido posible una vez evaluado el estado de la técnica y la investigación, los aspectos que influyen en la integración arquitectónica y los diferentes tipos de integración, después de haber examinado los métodos de ensayo para los componentes de construcción y fotovoltaicos, en condiciones de operación utilizadas hasta ahora. El laboratorio de pruebas experimentales, que consiste en dos habitaciones idénticas a escala real, 1:1, ha sido equipado con sensores y todos los sistemas de monitorización gracias a los cuales es posible obtener datos fiables para evaluar las prestaciones térmicas, de iluminación y el rendimiento eléctrico de los módulos fotovoltaicos. Este laboratorio permite el estudio de tres diferentes aspectos que influencian el confort y consumo de energía del edificio: el confort térmico, lumínico, y el rendimiento energético global (demanda/producción de energía) de los módulos BIPV. Conociendo el balance de energía para cada tecnología solar fotovoltaica experimentada, es posible determinar cuál funciona mejor en cada caso específico. Se ha propuesto una metodología teórica para la evaluación de estos parámetros, definidos en esta tesis como índices o indicadores que consideran cuestiones relacionados con el bienestar, la energía y el rendimiento energético global de los componentes BIPV. Esta metodología considera y tiene en cuenta las normas reglamentarias y estándares existentes para cada aspecto, relacionándolos entre sí. Diferentes módulos BIPV de doble vidrio aislante, semitransparentes, representativos de diferentes tecnologías fotovoltaicas (tecnología de silicio monocristalino, m-Si; de capa fina en silicio amorfo unión simple, a-Si y de capa fina en diseleniuro de cobre e indio, CIS) fueron seleccionados para llevar a cabo una serie de pruebas experimentales al objeto de demostrar la validez del método de caracterización propuesto. Como resultado final, se ha desarrollado y generado el Diagrama Caracterización Integral DCI, un sistema gráfico y visual para representar los resultados y gestionar la información, una herramienta operativa útil para la toma de decisiones con respecto a las instalaciones fotovoltaicas. Este diagrama muestra todos los conceptos y parámetros estudiados en relación con los demás y ofrece visualmente toda la información cualitativa y cuantitativa sobre la eficiencia energética de los componentes BIPV, por caracterizarlos de manera integral. ABSTRACT A sustainable design process today is intended to produce high-performance buildings that are energy-efficient, healthy and economically feasible, by wisely using renewable resources to minimize the impact on the environment and to reduce, as much as possible, the energy demand. In the last decade, the reduction of energy needs in buildings has become a top priority. The Directive 2002/91/EC “Energy Performance of Buildings” (and its subsequent updates) established a general regulatory framework’s methodology for calculation of minimum energy requirements. Since then, the aim of fulfilling new directives and protocols has led the energy policies in several countries in a similar direction that is, focusing on the need of increasing energy efficiency in buildings, taking measures to reduce energy consumption, and fostering the use of renewable sources. Zero Energy Buildings or Net Zero Energy Buildings will become a standard in the European building industry and in order to balance energy consumption, buildings, in addition to reduce the end-use consumption should necessarily become selfenergy producers. For this reason, the façade system plays an important role for achieving these energy and environmental goals and Photovoltaic can play a leading role in this challenge. To promote the use of photovoltaic technology in buildings, international research programs encourage and support solutions, which favors the complete integration of photovoltaic devices as an architectural element, the so-called BIPV (Building Integrated Photovoltaic), furthermore facing to next future towards net-zero energy buildings. Therefore, the BIPV module/system becomes a multifunctional building layer, not only physically and functionally “integrated” in the building, but also used as an innovative chance for the building envelope design. It has been found in this study that there is still a lack of useful information about BIPV for architects and designers even though the market is providing more and more interesting solutions, sometimes comparable to the existing traditional building systems. However at the moment, the lack of an harmonized regulation and standardization besides to the non-accuracy in the technical BIPV datasheets (not yet comparable with the same ones available for building materials), makes difficult for a designer to properly evaluate the fesibility of this BIPV components when used as a technological system of the building skin. International organizations are working to establish the most suitable standards and test procedures to check the safety, feasibility and reliability of BIPV systems. Anyway, nowadays, there are no specific rules for a complete characterization and evaluation of a BIPV component according to the European Construction Product Regulation, CPR 305/2011. BIPV products, as building components, must comply with different practical aspects such as mechanical resistance and stability; structural integrity; safety in use; protection against weather (rain, snow, wind, hail); fire and noise: aspects that have become essential requirements in the perspective of more and more environmentally sustainable, healthy, energy efficient and economically affordable products. IEC standards, commonly used in Europe to certify PV modules (IEC 61215 and IEC 61646 respectively crystalline and thin-film ‘Terrestrial PV Modules-Design Qualification and Type Approval’), attest the feasibility and reliability of PV modules for a defined period of time with a limited power decrease. There is also a standard (IEC 61853, ‘Performance Testing and Energy Rating of Terrestrial PV Modules’) still under preparation, whose aim is finding appropriate test procedures and methodologies to calculate the energy yield of PV modules under different climate conditions. Furthermore, the lack of tests in specific conditions of installation (e.g. façade BIPV devices) means that it is difficult knowing the exact effective performance of these systems and the environmental conditions in which the building will operate. The nominal PV power at Standard Test Conditions, STC (1.000 W/m2, 25 °C temperature and AM 1.5) is usually measured in indoor laboratories, and it characterizes the PV module at specific conditions in order to be able to compare different modules and technologies on a first step. The “Watt-peak” is not enough to evaluate the panel performance in terms of Watt-hours of various modules under different operating conditions, and it gives no assurance of being able to predict the energy performance of a certain module at given environmental conditions. A proper BIPV element for façade should take into account thermal and insulation properties, factors as transparency to allow solar gains if possible or a good solar control if necessary, aspects that are linked and high dependent on climate conditions and on the level of comfort to be reached. However, the influence of different façade integrated photovoltaic solutions on the building energy consumption is not easy to assess under real operating conditions. Thermal aspects, indoor temperatures or luminance level that can be expected using building integrated PV (BIPV) modules are not well known. As said before, integrated photovoltaic BIPV components and the use of renewable energy is already a standard for green energy production, but would also be important to know the possible contribution to improve the comfort and health of building occupants. Comfort, light transmission or protection, thermal insulation or thermal/electricity power production are aspects that are usually considered alone, while all together contribute to the building global energy balance. Besides, the need to prioritize a particular building envelope orientation to harvest the most benefit from the electrical or thermal energy production, in the case of active and passive systems respectively might be not compatible, but also not necessary. A holistic approach is needed to enable architects and engineers implementing technological systems working in synergy. A new concept have been suggested: “C-BIPV, conscious integrated BIPV”. BIPV systems have to be “consciously integrated” which means that it is essential to know the positive and negative effects in terms of comfort and energy under real operating conditions. Purpose of the work, method and results The façade-integrated photovoltaic systems are often glass solutions easily integrable, as they usually are custommade. These BIPV semi-transparent components integrated as a window element provides natural lighting and shade that prevents overheating at times of excessive heat, but as static component, likewise avoid the possible solar gains contributions in the cold months. In addition, the temperature of the module varies considerably in certain circumstances influenced by the PV technology installed, solar radiation, mounting system, lack of ventilation, etc. This factor may result in additional heat input in the building highly variable and difficult to quantify. In addition, further insights into the indoor environmental comfort in buildings using integrated photovoltaic technologies are needed to open up thereby, a new research perspective. This research aims to study their behaviour through a series of experiments in order to define the real influence on comfort aspects and on global energy building consumption, as well as, electrical and thermal characteristics of these devices. The final objective was to analyze a whole set of issues that influence the global energy consumption/production in a building using BIPV modules by quantifying the global energy balance and the BIPV system real performances. Other qualitative issues to be studied were comfort aspect (thermal and lighting aspects) and the electrical behaviour of different BIPV technologies for vertical integration, aspects that influence both energy consumption and electricity production. Thus, it will be possible to obtain a comprehensive global characterization of BIPV systems. A specific design of an outdoor test facility, the BIPV Env-lab “BIPV Test Laboratory”, for the integral characterization of different BIPV semi-transparent modules was developed and built. The method and test protocol for the BIPV characterization was also defined in a real building context and weather conditions. This has been possible once assessed the state of the art and research, the aspects that influence the architectural integration and the different possibilities and types of integration for PV and after having examined the test methods for building and photovoltaic components, under operation conditions heretofore used. The test laboratory that consists in two equivalent test rooms (1:1) has a monitoring system in which reliable data of thermal, daylighting and electrical performances can be obtained for the evaluation of PV modules. The experimental set-up facility (testing room) allows studying three different aspects that affect building energy consumption and comfort issues: the thermal indoor comfort, the lighting comfort and the energy performance of BIPV modules tested under real environmental conditions. Knowing the energy balance for each experimented solar technology, it is possible to determine which one performs best. A theoretical methodology has been proposed for evaluating these parameters, as defined in this thesis as indices or indicators, which regard comfort issues, energy and the overall performance of BIPV components. This methodology considers the existing regulatory standards for each aspect, relating them to one another. A set of insulated glass BIPV modules see-through and light-through, representative of different PV technologies (mono-crystalline silicon technology, mc-Si, amorphous silicon thin film single junction, a-Si and copper indium selenide thin film technology CIS) were selected for a series of experimental tests in order to demonstrate the validity of the proposed characterization method. As result, it has been developed and generated the ICD Integral Characterization Diagram, a graphic and visual system to represent the results and manage information, a useful operational tool for decision-making regarding to photovoltaic installations. This diagram shows all concepts and parameters studied in relation to each other and visually provides access to all the results obtained during the experimental phase to make available all the qualitative and quantitative information on the energy performance of the BIPV components by characterizing them in a comprehensive way.
Resumo:
El cambio climático y sus efectos requieren con urgencia el desarrollo de estrategias capaces no solo de mitigar pero también permitir la adaptación de los sistemas afectados por este fenómeno a los cambios que están provocando a nivel mundial. Olas de calor más largas y frecuentes, inundaciones, y graves sequías aumentan la vulnerabilidad de la población, especialmente en asentamientos urbanos. Este fenómeno y sus soluciones potenciales han sido ampliamente estudiados en las últimas décadas desde diferentes perspectivas y escalas que analizan desde el fenómeno regional de isla de calor al aumento de la intensidad energética necesaria en los edificios para mantener las condiciones de confort en los escenarios de calentamiento que se predicen. Su comprensión requiere el entendimiento de este fenómeno y un profundo análisis de las estrategias que pueden corregirlo y adaptarse a él. En la búsqueda de soluciones a este problema, las estrategias que incorporan sistemas naturales tales como las cubiertas ajardinadas, las fachadas vegetadas y bosques urbanos, se presentan como opciones de diseño capaces de proporcionan múltiples servicios al ecosistema urbano y de regular y hacer frente a los efectos del cambio climático. Entre los servicios que aportan estos sistemas naturales se incluyen la gestión de agua de tormentas, el control del efecto isla de calor, la mejora de la calidad del aire y del agua, el aumento de la diversidad, y como consecuencia de todo lo anterior, la reducción de la huella ecológica de las ciudades. En la última década, se han desarrollado múltiples estudios para evaluar y cuantificar los servicios al ecosistema proporcionados por las infraestructuras verdes, y específicamente las cubiertas ajardinadas, sin embargo, determinados servicios como la capacidad de la regulación del microclima urbano no ha sido apenas estudiados. La mayor parte de la literatura en este campo la componen estudios relacionados con la capacidad de las cubiertas ajardinadas de reducir el efecto de la isla de calor, en una escala local, o acerca de la reducción de la demanda energética de refrigeración debida a la instalación de cubiertas ajardinadas en la escala de edificio. La escala intermedia entre estos dos ámbitos, la calle, desde su ámbito habitable cercano al suelo hasta el límite superior del cañón urbano que configura, no han sido objeto detallado de estudio por lo que es esta escala el objeto de esta tesis doctoral. Esta investigación tiene como objeto contribuir en este campo y aportar un mayor entendimiento a través de la cuantificación del impacto de las cubiertas ajardinadas sobre la temperatura y humedad en el cañón urbano en la escala de calle y con un especial foco en el nivel peatonal. El primer paso de esta investigación ha sido la definición del objeto de estudio a través del análisis y revisión de trabajos tanto teóricos como empíricos que investigan los efectos de cubiertas ajardinadas en el entorno construido, entendidas como una herramienta para la adaptación y mitigación del impacto del cambio climático en las ciudades. La literatura analizada, revela el gran potencial de los sistemas vegetales como herramientas para el diseño pasivo puesto que no solo son capaces de mejorar las condiciones climáticas y microclimaticas en las ciudades reduciendo su demanda energética, sino también la necesidad de mayor análisis en la escala de calle donde confluyen el clima, las superficies urbanas y materiales y vegetación. Este análisis requiere una metodología donde se integren la respuesta térmica de edificios, las variaciones en los patrones de viento y radiación, y la interacción con la vegetación, por lo que un análisis cuantitativo puede ayudar a definir las estrategias más efectivas para lograr espacios urbanos más habitables. En este contexto, el objetivo principal de esta investigación ha sido la evaluación cuantitativa del impacto de la cubierta ajardinada en el microclima urbano a escala de barrio en condiciones de verano en los climas mediterráneos continentales. Para el logro de este objetivo, se ha seguido un proceso que persigue identificar los modelos y herramientas de cálculo capaces de capturar el efecto de la cubierta ajardinada sobre el microclima, identificar los parámetros que potencian o limitan este efecto, y cuantificar las variaciones que microclima creado en el cañón urbano produce en el consumo de energía de los edificios que rodean éste espacio. La hipótesis principal detrás de esta investigación y donde los objetivos anteriores se basan es el siguiente: "una cubierta ajardinada instalada en edificios de mediana altura favorece el establecimiento de microclimas a nivel peatonal y reduce las temperaturas en el entorno urbano donde se encuentra”. Con el fin de verificar la hipótesis anterior y alcanzar los objetivos propuestos se ha seguido la siguiente metodología: • definición del alcance y limitaciones del análisis • Selección de las herramientas y modelos de análisis • análisis teórico de los parámetros que afectan el efecto de las cubiertas ajardinadas • análisis experimental; • modelización energética • conclusiones y futuras líneas de trabajo Dada la complejidad de los fenómenos que intervienen en la generación de unas determinadas condiciones microclimáticas, se ha limitado el objeto de este estudio a las variables de temperatura y humedad, y sólo se han tenido en cuenta los componentes bióticos y abióticos del sistema, que incluyen la morfología, características superficiales del entorno estudiado, así como los elementos vegetales. Los componentes antrópicos no se han incluido en este análisis. La búsqueda de herramientas adecuadas para cumplir con los objetivos de este análisis ha concluido en la selección de ENVI-met v4 como el software más adecuado para esta investigación por su capacidad para representar los complejos fenómenos que caracterizan el microclima en cañones urbanos, en una escala temporal diaria y con unas escala local de vecindario. Esta herramienta supera el desafío que plantean los requisitos informáticos de un cálculo completo basado en elementos finitos realizados a través de herramientas de dinámica de fluidos computacional (CFD) que requieren una capacidad de cálculo computacional y tiempo privativos y en una escala dimensional y temporal limitada a esta capacidad computacional lo que no responde a los objetivos de esta investigación. ENVI-met 4 se basa es un modelo tridimensional del micro clima diseñado para simular las interacciones superficie-planta-aire en entornos urbanos. Basado en las ecuaciones fundamentales del equilibrio que representan, la conservación de masa, energía y momento. ENVI-met es un software predictivo, y como primer paso ha requerido la definición de las condiciones iniciales de contorno que se utilizan como punto de partida por el software para generar su propio perfil de temperatura y humedad diaria basada en la localización de la construcción, geometría, vegetación y las superficies de características físicas del entorno. La geometría de base utilizada para este primer análisis se ha basado en una estructura típica en cuanto al trazado urbano situada en Madrid que se ha simulado con una cubierta tradicional y una cubierta ajardinada en sus edificios. La estructura urbana seleccionada para este análisis comparativo es una red ortogonal con las calles principales orientadas este-oeste. El edificio típico que compone el vecindario se ha definido como “business as usual” (BAU) y se ha definido con una cubierta de baldosa de hormigón estándar, con un albedo 0.3, paredes con albedo 0.2 (construcción de muro de ladrillo típico) y cerramientos adiabáticos para evitar las posibles interferencias causadas por el intercambio térmico con el ambiente interior del edificio en los resultados del análisis. Para el caso de la cubierta ajardinada, se mantiene la misma geometría y características del edificio con excepción de la cobertura superficial de la azotea. Las baldosas de hormigón se han modificado con una cubierta ajardinada extensiva cubierta con plantas xerófilas, típicas en el clima de Madrid y caracterizado por su índice de densidad foliar, el “leaf area density” (LAD), que es la superficie total de superficie de hojas por unidad de volumen (m2/m3). El análisis se centra en los cañones urbanos entendidos como el espacio de calle comprendido entre los límites geométricos de la calle, verticales y horizontales, y el nivel superior de la cota urbana nivel de cubiertas. Los escenarios analizados se basan en la variación de la los principales parámetros que según la literatura analizada condicionan las variaciones microclimáticas en el ámbito urbano afectado por la vegetación, la velocidad del viento y el LAD de la azotea. Los resultados han sido registrados bajo condiciones de exposición solar diferentes. Las simulaciones fueron realizadas por los patrones de viento típico de verano, que para Madrid se caracterizan por vientos de componente suroeste que van desde 3 a 0 m/s. las simulaciones fueron realizadas para unas condiciones climáticas de referencia de 3, 2, 1 y 0 m/s a nivel superior del cañón urbano, como condición de contorno para el análisis. Los resultados calculados a 1,4 metros por encima del nivel del suelo, en el espacio habitado, mostraron que el efecto de la cubierta ajardinada era menor en condiciones de contorno con velocidades de viento más altas aunque en ningún caso el efecto de la cubierta verde sobre la temperatura del aire superó reducciones de temperatura de aire superiores a 1 º C. La humedad relativa no presentó variaciones significativas al comparar los diferentes escenarios. Las simulaciones realizadas para vientos con velocidad baja, entre 0 y 1 m/s mostraron que por debajo de 0.5 m/s la turbulencia del modelo aumentó drásticamente y se convirtió en el modelo inestable e incapaz de producir resultados fiables. Esto es debido al modelo de turbulencia en el software que no es válido para velocidades de viento bajas, lo que limita la capacidad de ENVI-met 4 para realizar simulaciones en estas condiciones de viento y es una de las principales conclusiones de este análisis en cuanto a la herramienta de simulación. También se comprobó el efecto de las densidades de la densidad de hoja (LAD) de los componentes vegetales en el modelo en la capa de aire inmediatamente superior a la cubierta, a 0,5 m sobre este nivel. Se compararon tres alternativas de densidad de hoja con la cubierta de baldosa de hormigón: el techo verde con LAD 0.3 (hierba típica o sedum), LAD 1.5 (plantas mixtas típicas) y LAD 2.5 (masa del árbol). Los resultados mostraron diferencias de temperatura muy relevante entre las diferentes alternativas de LAD analizadas. Los resultados muestran variaciones de temperatura que oscilan entre 3 y 5 º C al comparar el estándar de la azotea concreta con albedo 0, 3 con el techo con vegetación y vegetación densa, mostrando la importancia del LAD en la cuantificación de los efectos de las cubiertas vegetales en microclima circundante, lo que coincide con los datos reportados en la literatura existente y con los estudios empíricos analizados. Los resultados de los análisis teóricos han llegado a las siguientes conclusiones iniciales relacionadas con la herramienta de simulación y los resultados del modelo: En relación con la herramienta ENVI-met, se han observado limitaciones para el análisis. En primer lugar, la estructura rígida de la geometría, las bases de datos y el tamaño de la cuadrícula, limitan la escala y resolución de los análisis no permitiendo el desarrollo de grandes zonas urbanas. Por otro lado la estructura de ENVI-met permite el desarrollo de este tipo de simulación tan complejo dentro de tiempos razonables de cálculo y requerimientos computacionales convencionales. Otra limitación es el modelo de turbulencia del software, que no modela correctamente velocidades de viento bajas (entre 0 y 1 m/s), por debajo de 0,5 m/s el modelo da errores y no es estable, los resultados a estas velocidades no son fiables porque las turbulencias generadas por el modelo hacen imposible la extracción de patrones claros de viento y temperatura que permitan la comparación entre los escenarios de cubierta de hormigón y ajardinada. Además de las limitaciones anteriores, las bases de datos y parámetros de entrada en la versión pública del software están limitados y la complejidad de generar nuevos sistemas adaptándolos al edificio o modelo urbano que se quiera reproducir no es factible salvo en la versión profesional del software. Aparte de las limitaciones anteriores, los patrones de viento y perfiles de temperatura generados por ENVI-met concuerdan con análisis previos en los que se identificaban patrones de variación de viento y temperaturas en cañones urbanos con patrones de viento, relación de aspecto y dimensiones similares a los analizados en esta investigación. Por lo tanto, el software ha demostrado una buena capacidad para reproducir los patrones de viento en los cañones de la calle y capturar el efecto de enfriamiento producido por la cubierta verde en el cañón. En relación con el modelo, el resultado revela la influencia del viento, la radiación y el LAD en la temperatura del aire en cañones urbanos con relación de aspecto comprendida entre 0,5 y 1. Siendo el efecto de la cubierta verde más notable en cañones urbanos sombreados con relación de aspecto 1 y velocidades de viento en el nivel de “canopy” (por encima de la cubierta) de 1 m/s. En ningún caso las reducciones en la temperatura del aire excedieron 1 º C, y las variaciones en la humedad relativa no excedieron 1% entre los escenarios estudiados. Una vez que se han identificado los parámetros relevantes, que fueron principalmente la velocidad del viento y el LAD, se realizó un análisis experimental para comprobar los resultados obtenidos por el modelo. Para éste propósito se identificó una cubierta ajardinada de grandes dimensiones capaz de representar la escala urbana que es el objeto del estudio. El edificio usado para este fin fue el parking de la terminal 4 del aeropuerto internacional de Madrid. Aunque esto no es un área urbana estándar, la escala y la configuración del espacio alrededor del edificio fueron considerados aceptables para el análisis por su similitud con el contexto urbano objeto de estudio. El edificio tiene 800 x 200 m, y una altura 15 m. Está rodeado de vías de acceso pavimentadas con aceras conformando un cañón urbano limitado por el edificio del parking, la calle y el edificio de la terminal T4. El aparcamiento está cerrado con fachadas que configuran un espacio urbano de tipo cañón, con una relación de aspecto menor que 0,5. Esta geometría presenta patrones de viento y velocidad dentro del cañón que difieren ligeramente de los generados en el estudio teórico y se acercan más a los valores a nivel de canopo sobre la cubierta del edificio, pero que no han afectado a la tendencia general de los resultados obtenidos. El edificio cuenta con la cubierta ajardinada más grande en Europa, 12 Ha cubiertas por con una mezcla de hierbas y sedum y con un valor estimado de LAD de 1,5. Los edificios están rodeados por áreas plantadas en las aceras y árboles de sombra en las fachadas del edificio principal. El efecto de la cubierta ajardinada se evaluó mediante el control de temperaturas y humedad relativa en el cañón en un día típico de verano. La selección del día se hizo teniendo en cuenta las predicciones meteorológicas para que fuesen lo más semejantes a las condiciones óptimas para capturar el efecto de la cubierta vegetal sobre el microclima urbano identificadas en el modelo teórico. El 09 de julio de 2014 fue seleccionado para la campaña de medición porque las predicciones mostraban 1 m/s velocidad del viento y cielos despejados, condiciones muy similares a las condiciones climáticas bajo las que el efecto de la cubierta ajardinada era más notorio en el modelo teórico. Las mediciones se registraron cada hora entre las 9:00 y las 19:00 en 09 de julio de 2014. Temperatura, humedad relativa y velocidad del viento se registraron en 5 niveles diferentes, a 1.5, 4.5, 7.5, 11.5 y 16 m por encima del suelo y a 0,5 m de distancia de la fachada del edificio. Las mediciones fueron tomadas en tres escenarios diferentes, con exposición soleada, exposición la sombra y exposición influenciada por los árboles cercanos y suelo húmedo. Temperatura, humedad relativa y velocidad del viento se registraron con un equipo TESTO 410-2 con una resolución de 0,1 ºC para temperatura, 0,1 m/s en la velocidad del viento y el 0,1% de humedad relativa. Se registraron las temperaturas de la superficie de los edificios circundantes para evaluar su efecto sobre los registros usando una cámara infrarroja FLIR E4, con resolución de temperatura 0,15ºC. Distancia mínima a la superficie de 0,5 m y rango de las mediciones de Tª de - 20 º C y 250 º C. Los perfiles de temperatura extraídos de la medición in situ mostraron la influencia de la exposición solar en las variaciones de temperatura a lo largo del día, así como la influencia del calor irradiado por las superficies que habían sido expuestas a la radiación solar así como la influencia de las áreas de jardín alrededor del edificio. Después de que las medidas fueran tomadas, se llevaron a cabo las siguientes simulaciones para evaluar el impacto de la cubierta ajardinada en el microclima: a. estándar de la azotea: edificio T4 asumiendo un techo de tejas de hormigón con albedo 0.3. b. b. cubierta vegetal : T4 edificio asumiendo una extensa cubierta verde con valor bajo del LAD (0.5)-techo de sedum simple. c. c. cubierta vegetal: T4 edificio asumiendo una extensa cubierta verde con alta joven valor 1.5-mezcla de plantas d. d. cubierta ajardinada más vegetación nivel calle: el edificio T4 con LAD 1.5, incluyendo los árboles existentes a nivel de calle. Este escenario representa las condiciones actuales del edificio medido. El viento de referencia a nivel de cubierta se fijó en 1 m/s, coincidente con el registro de velocidad de viento en ese nivel durante la campaña de medición. Esta velocidad del viento se mantuvo constante durante toda la campaña. Bajo las condiciones anteriores, los resultados de los modelos muestran un efecto moderado de azoteas verdes en el microclima circundante que van desde 1 º a 2 º C, pero una contribución mayor cuando se combina con vegetación a nivel peatonal. En este caso las reducciones de temperatura alcanzan hasta 4 ºC. La humedad relativa sin embargo, no presenta apenas variación entre los escenarios con y sin cubierta ajardinada. Las temperaturas medidas in situ se compararon con resultados del modelo, mostrando una gran similitud en los perfiles definidos en ambos casos. Esto demuestra la buena capacidad de ENVI-met para reproducir el efecto de la cubierta ajardinada sobre el microclima y por tanto para el fin de esta investigación. Las diferencias más grandes se registraron en las áreas cercanas a las zonas superiores de las fachadas que estaban más expuestas a la radiación del sol y también el nivel del suelo, por la influencia de los pavimentos. Estas diferencias se pudieron causar por las características de los cerramientos en el modelo que estaban limitados por los datos disponibles en la base de datos de software, y que se diferencian con los del edificio real. Una observación importante derivada de este estudio es la contribución del suelo húmedo en el efecto de la cubierta ajardinada en la temperatura del aire. En el escenario de la cubierta ajardinada con los arboles existentes a pie de calle, el efecto del suelo húmedo contribuye a aumentar las reducciones de temperatura hasta 4.5ºC, potenciando el efecto combinado de la cubierta ajardinada y la vegetación a pie de calle. Se realizó un análisis final después de extraer el perfil horario de temperaturas en el cañón urbano influenciado por el efecto de las cubiertas ajardinadas y los árboles. Con esos perfiles modificados de temperatura y humedad se desarrolló un modelo energético en el edificio asumiendo un edificio cerrado y climatizado, con uso de oficinas, una temperatura de consigna de acuerdo al RITE de 26 ºC, y con los sistemas por defecto que establece el software para el cálculo de la demanda energética y que responden a ASHRAE 90.1. El software seleccionado para la simulación fue Design Builder, por su capacidad para generar simulaciones horarias y por ser una de las herramientas de simulación energética más reconocidas en el mercado. Los perfiles modificados de temperatura y humedad se insertaron en el año climático tipo y se condujo la simulación horaria para el día definido, el 9 de Julio. Para la simulación se dejaron por defecto los valores de conductancia térmica de los cerramientos y la eficiencia de los equipos de acuerdo a los valores que fija el estándar ASHRAE para la zona climática de Madrid, que es la 4. El resultado mostraba reducciones en el consumo de un día pico de hasta un 14% de reducción en las horas punta. La principal conclusión de éste estudio es la confirmación del potencial de las cubiertas ajardinadas como una estrategia para reducir la temperatura del aire y consumo de energía en los edificios, aunque este efecto puede ser limitado por la influencia de los vientos, la radiación y la especie seleccionada para el ajardinamiento, en especial de su LAD. Así mismo, en combinación con los bosques urbanos su efecto se potencia e incluso más si hay pavimentos húmedos o suelos porosos incluidos en la morfología del cañón urbano, convirtiéndose en una estrategia potencial para adaptar los ecosistemas urbanos el efecto aumento de temperatura derivado del cambio climático. En cuanto a la herramienta, ENVI-met se considera una buena opción para éste tipo de análisis dada su capacidad para reproducir de un modo muy cercano a la realidad el efecto de las cubiertas. Aparte de ser una herramienta validada en estudios anteriores, en el caso experimental se ha comprobado por medio de la comparación de las mediciones con los resultados del modelo. A su vez, los resultados y patrones de vientos generados en los cañones urbanos coinciden con otros estudios similares, concluyendo por tanto que es un software adecuado para el objeto de esta tesis doctoral. Como líneas de investigación futura, sería necesario entender el efecto de la cubierta ajardinada en el microclima urbano en diferentes zonas climáticas, así como un mayor estudio de otras variables que no se han observado en este análisis, como la temperatura media radiante y los indicadores de confort. Así mismo, la evaluación de otros parámetros que afectan el microclima urbano tales como variables geométricas y propiedades superficiales debería ser analizada en profundidad para tener un resultado que cubra todas las variables que afectan el microclima en el cañón urbano. ABSTRACT Climate Change is posing an urgency in the development of strategies able not only to mitigate but also adapt to the effects that this global problem is evidencing around the world. Heat waves, flooding and severe draughts increase the vulnerability of population, and this is especially critical in urban settlements. This has been extensively studied over the past decades, addressed from different perspectives and ranging from the regional heat island analysis to the building scale. Its understanding requires physical and dimensional analysis of this broad phenomenon and a deep analysis of the factors and the strategies which can offset it. In the search of solutions to this problem, green infrastructure elements such as green roofs, walls and urban forests arise as strategies able provide multiple regulating ecosystem services to the urban environment able to cope with climate change effects. This includes storm water management, heat island effect control, and improvement of air and water quality. Over the last decade, multiple studies have been developed to evaluate and quantify the ecosystem services provided by green roofs, however, specific regulating services addressing urban microclimate and their impact on the urban dwellers have not been widely quantified. This research tries to contribute to fill this gap and analyzes the effects of green roofs and urban forests on urban microclimate at pedestrian level, quantifying its potential for regulating ambient temperature in hot season in Mediterranean –continental climates. The study is divided into a sequence of analysis where the critical factors affecting the performance of the green roof system on the microclimate are identified and the effects of the green roof is tested in a real case study. The first step has been the definition of the object of study, through the analysis and review of theoretical and empirical papers that investigate the effects of covers landscaped in the built environment, in the context of its use as a tool for adaptation and mitigation of the impact of climate change on cities and urban development. This literature review, reveals the great potential of the plant systems as a tool for passive design capable of improving the climatic and microclimatic conditions in the cities, as well as its positive impact on the energy performance of buildings, but also the need for further analysis at the street scale where climate, urban surfaces and materials, and vegetation converge. This analysis requires a methodology where the thermal buildings response, the variations in the patterns of wind and the interaction of the vegetation are integrated, so a quantitative analysis can help to define the most effective strategies to achieve liveable urban spaces and collaterally, , the improvement of the surrounding buildings energy performance. In this specific scale research is needed and should be customized to every climate, urban condition and nature based strategy. In this context, the main objective for this research was the quantitative assessment of the Green roof impact on the urban microclimate at a neighbourhood scale in summer conditions in Mediterranean- continental climates. For the achievement of this main objective, the following secondary objectives have been set: • Identify the numerical models and calculation tools able to capture the effect of the roof garden on the microclimate. • Identify the enhancing or limiting parameter affecting this effect. • Quantification of the impact of the microclimate created on the energy consumption of buildings surrounding the street canyon analysed. The main hypothesis behind this research and where the above objectives are funded on is as follows: "An extensive roof installed in medium height buildings favours the establishment of microclimates at the pedestrian level and reduces the temperatures in the urban environment where they are located." For the purpose of verifying the above hypothesis and achieving the proposed objectives the following methodology has been followed: - Definition of hypothesis and objectives - Definition of the scope and limitations - Theoretical analysis of parameters affecting gren roof performance - Experimental analysis; - Energy modelling analyisis - Conclusions and future lines of work The search for suitable tools and models for meeting the objectives of this analysis has led to ENVI-met v4 as the most suitable software for this research. ENVI met is a three-dimensional micro-climate model designed to simulate the surface-plant-air interactions in urban environments. Based in the fundamental equations representing, mass, energy and momentum conservation, the software has the capacity of representing the complex phenomena characterizing the microclimate in urban canyons, overcoming the challenge posed by the computing requirements of a full calculus based on finite elements done via traditional computational fluid dynamics tools. Once the analysis tool has been defined, a first set of analysis has been developed to identify the main parameters affecting the green roof influence on the microclimate. In this analysis, two different scenarios are compared. A neighborhood with standard concrete tile roof and the same configuration substituting the concrete tile by an extensive green roof. Once the scenarios have been modeled, different iterations have been run to identify the influence of different wind patterns, solar exposure and roof vegetation type on the microclimate, since those are the most relevant variables affecting urban microclimates. These analysis have been run to check the conditions under which the effects of green roofs get significance. Since ENVI-met V4 is a predictive software, the first step has been the definition of the initial weather conditions which are then used as starting point by the software, which generates its own daily temperature and humidity profile based on the location of the building, geometry, vegetation and the surfaces physical characteristics. The base geometry used for this first analysis has been based on a typical urban layout structure located in Madrid, an orthogonal net with the main streets oriented East-West to ease the analysis of solar radiation in the different points of the model. This layout represents a typical urban neighborhood, with street canyons keeping an aspect ratio between 0.5 and 1 and high sky view factor to ensure correct sun access to the streets and buildings and work with typical wind flow patterns. Finally, the roof vegetation has been defined in terms of foliage density known as Leaf Area Density (LAD) and defined as the total one-sided leaf area per unit of layer volume. This index is the most relevant vegetation characteristic for the purpose of calculating the effect of vegetation on wind and solar radiation as well as the energy consumed during its metabolic processes. The building as usual (BAU) configuring the urban layout has been defined with standard concrete tile roofs, considering 0.3 albedo. Walls have been set with albedo 0.2 (typical brick wall construction) and adiabatic to avoid interference caused by thermal interchanges with the building indoor environment. For the proposed case, the same geometry and building characteristics have been kept. The only change is the roof surface coverage. The gravel on the roof has been changed with an extensive green roof covered with drought tolerant plants, typical in Madrid climate, and characterized by their LAD. The different scenarios analysed are based in the variation of the wind speed and the LAD of the roof. The results have been recorded under different sun exposure conditions. Simulations were run for the typical summer wind patterns, that for Madrid are characterized by South-west winds ranging from 3 to 0 m/s. Simulations were run for 3, 2, 1 and 0 m/s at urban canopy level. Results taken at 1.4 m above the ground showed that the green roof effect was lower with higher wind speeds and in any case the effect of the green roof on the air temperatures exceeded air temperature reductions higher than 1ºC. Relative humidity presented no variations when comparing the different scenarios. For the analysis at 0m/s, ENVI-met generated error and no results were obtained. Different simulations showed that under 0.5 m/s turbulence increased dramatically and the model became unstable and unable to produce reliable results. This is due to the turbulence model embedded in the software which is not valid for low wind speeds (below 1 m/s). The effect of the different foliage densities was also tested in the model. Three different alternatives were compared against the concrete roof: green roof with LAD 0.3 ( typical grass or sedum), 1.5 (typical mixed plants) and 2.5 (tree mass). The results showed very relevant temperature differences between the different LAD alternatives analyzed. Results show temperature variations ranging between 3 and 5 ºC when comparing the standard concrete roof with albedo 0, 3 with the vegetated roof and vegetated mass, showing the relevance of the LAD on the effects of green roofs on microclimate. This matches the data reported in existing literature and empirical studies and confirms the relevance of the LAD in the roof effect on the surrounding microclimate. The results of the theoretical analysis have reached the following initial conclusions related to both, the simulation tool and the model results: • In relation to the tool ENVI-met, some limitations for the analysis have been observed. In first place, the rigid structure of the geometry, the data bases and the grid size, limit the scale and resolution of the analysis not allowing the development of large urban areas. On the other hand the ENVI-met structure enables the development of this type of complex simulation within reasonable times and computational requirements for the purpose of this analysis. Additionally, the model is unable to run simulations at wind speeds lower than 0.5 m/s, and even at this speed, the results are not reliable because the turbulences generated by the model that made impossible to extract clear temperature differences between the concrete and green roof scenarios. Besides the above limitations, the wind patterns and temperature profiles generated by ENVImet are in agreement with previous analysis identifying wind patterns in urban canyons with similar characteristics and aspect ratio. Therefore the software has shown a good capacity for reproducing the wind effects in the street canyons and seems to capture the cooling effect produced by the green roof. • In relation to the model, the results reveals the influence of wind, radiation and LAD on air temperature in urban canyons with aspect ratio comprised between 0.5 and 1. Being the effect of the green roof more noticeable in shaded urban canyons with aspect ratio 1 and wind speeds of 1 m/s. In no case the reductions in air temperature exceeded 1ºC. Once the relevant parameters have been identified, mainly wind speed and LAD, an experimental analysis was conducted to test the results obtained by the model. For this purpose a large green roof was identified, able to represent the urban scale which is the object of the studio. The building identified for this purpose was the terminal 4, parking building of the international Madrid Airport. Even though this is not a standard urban area, the scale and configuration of the space around the building were deemed as acceptable for the analysis. The building is an 800x200 m, 15 m height parking building, surrounded by access paved paths and the terminal building. The parking is enclosed with facades that configure an urban canyon-like space, although the aspect ratio is lower than 0.5 and the wind patterns might differ from the theoretical model run. The building features the largest green roof in Europe, a 12 Ha extensive green roof populated with a mix of herbs and sedum with a LAD of 1.5. The buildings are surrounded by planted areas at the sidewalk and trees shading the main building facades. Green roof performance was evaluated by monitoring temperatures and relative humidity in the canyon in a typical summer day. The day selection was done taking into account meteorological predictions so the weather conditions on the measurement day were as close as possible as the optimal conditions identified in terms of green roof effects on the urban canyon. July 9th 2014 was selected for the measurement campaign because the predictions showed 1 m/s wind speed and sunny sky, which were very similar to the weather conditions where the effect of the green roof was most noticeable in the theory model. Measurements were registered hourly from 9:00am to 19:00 on July 9th 2014. Temperature, relative humidity and wind speed were recorded at 5 different levels, at 1.5, 4.5, 7.5, 11.5 and 16 m above ground and at 0.5 m distance from the building façade. Measurements were taken in three different scenarios, sunny exposure, shaded exposure, and shaded exposure influenced by nearby trees and moist soil. Temperature, relative humidity and wind speed were registered using a TESTO 410-2 anemometer, with 0.1ºC resolution for temperature, 0.1 m/s resolution for wind speed and 0.1 % for relative humidity. Surface temperatures were registered using an infrared camera FLIR E4, with temperature resolution 0.15ºC. Minimal distance to surface of 0.5 m and Tª measurements range from -20ºC and 250ºC. The temperature profiles measured on the site showed the influence of solar exposure on the temperature variations along the day, as well as the influence of the heat irradiated by the building surfaces which had been exposed to the sun radiation and those influenced by the moist soft areas around the building. After the measurements were taken, the following simulations were conducted to evaluate the impact of the green roof on the microclimate: a. Standard roof: T4 building assuming a concrete tile roof with albedo 0.3. b. Green roof: T4 building assuming an extensive green roof with low LAD value (0.5)-Simple Sedum roof. c. Green roof: T4 building assuming an extensive green roof with high LAD value 1.5- Lucerne and grasses d. Green roof plus street level vegetation: T4 Building, LAD 1.5 (Lucerne), including the existing trees at street level. This scenario represents the current conditions of the building. The urban canopy wind was set as 1 m/s, the wind speed register at that level during the measurement campaign. This wind speed remained constant over the whole campaign. Under the above conditions, the results of the models show a moderate effect of green roofs on the surrounding microclimate ranging from 1ºC to 2ºC, but a larger contribution when combining it with vegetation at pedestrian level, where 4ºC temperature reductions are reached. Relative humidity remained constant. Measured temperatures and relative humidity were compared to model results, showing a close match in the profiles defined in both cases and the good capacity of ENVI met to capture the impact of the green roof in this analysis. The largest differences were registered in the areas close to the top areas of the facades which were more exposed to sun radiation and also near to the soil level. These differences might be caused by differences between the materials properties included in the model (which were limited by the data available in the software database) and those in the real building. An important observation derived from this study is the contribution of moist soil to the green roof effect on air temperatures. In the green roof scenario with surrounding trees, the effect of the moist soil contributes to raise the temperature reductions at 4.5ºC. A final analysis was conducted after extracting the hourly temperature profile in the street canyon influenced by the effect of green roofs and trees. An energy model was run on the building assuming it was a conventional enclosed building. Energy demand reductions were registered in the building reaching up to 14% reductions at the peak hour. The main conclusion of this study is the potential of the green roofs as a strategy for reducing air temperatures and energy consumption in the buildings, although this effect can be limited by the influence of high speed winds. This effect can be enhanced its combination with urban forests and even more if soft moist pavements are included in the urban canyon morphology, becoming a potential strategy for adapting urban ecosystems to the increasing temperature effect derived from climate change.
Resumo:
La principal motivación para la elección del tema de la tesis es nuestra realidad energética y ambiental. Y más específicamente, la necesidad urgente de dar una respuesta a esta realidad desde el sector de la edificación. Por lo que, el trabajo parte de la búsqueda de soluciones pasivas que ayuden a la reducción del consumo energético y de las emisiones de C02 de los edificios, tanto nuevos como existentes. El objeto de estudio son aplicaciones innovadoras, basadas en el uso de materiales reactivos, con un efecto térmico de memoria bidireccional. La energía es un elemento imprescindible para el desarrollo. Sin embargo, el modelo energético predominante, basado principalmente en la utilización de combustibles de origen fósil, es uno de los importantes responsables del deterioro ambiental que sufre el planeta. Además, sus reservas son limitadas y están concentradas en unas pocas regiones del mundo, lo que genera problemas de dependencia, competitividad y de seguridad de suministro. Dado el gran potencial de ahorro energético del sector de la edificación, la Unión Europea en sus directivas enfatiza la necesidad de mejorar la eficiencia energética de los edificios. Añadiendo, además, la obligatoriedad de desarrollar edificios “energía casi nula”, cuyo prerrequisito es tener un muy alto rendimiento energético. En España, los edificios son responsables del 31% del consumo de energía primaria. La mayor parte de este consumo se relaciona a la utilización de sistemas activos de acondicionamiento. Una medida efectiva para reducir la demanda es mejorar la envolvente. Sin embargo, hay que buscar estrategias adicionales para aumentar aún más la eficiencia de los edificios nuevos y existentes. Para los climas de España, el uso de la inercia térmica ha probado ser una estrategia válida. Sin embargo, su funcionamiento está vinculado al peso y al volumen de los materiales utilizados. Esto limita sus posibilidades en la rehabilitación energética y en los nuevos edificios basados en la construcción ligera. Una alternativa es el uso de aplicaciones de almacenamiento térmico por calor latente, utilizando materiales de cambio de fase (PCM). Los PCM son sustancias con un muy alto calor de fusión, capaces de almacenar una gran cantidad de energía térmica sin requerir aumentos significativos de peso o volumen. Estas características los hacen idóneos para reducir el consumo relacionado con el acondicionamiento térmico, en edificios nuevos y existentes. En la parte preliminar de la investigación, se encontró que para lograr un aprovechamiento óptimo de las aplicaciones con PCM es necesario tener un conocimiento profundo de su funcionamiento y de las variables del sistema. De ahí que el objetivo principal de la presente tesis sea: establecer las bases para la optimizatión integral de las aplicaciones con almacenamiento de energía térmica por calor latente, identificando y validando sus variables más relevantes. La investigación consta de tres partes. La primera, documental, sistematizando y jerarquizando la información científica publicada; la segunda, numérica, basada en un análisis paramétrico de una aplicación con PCM, utilizando simulaciones térmicas; y la tercera, experimental, monitorizando el funcionamiento térmico y energético de diferentes aplicaciones con PCM en módulos a escala real. Los resultados brindan un más profundo entendimiento del funcionamiento de las aplicaciones evaluadas. Han permitido identificar sus variables relevantes, cuantificar su influencia, y determinar condiciones óptimas para su utilización así como situaciones en las que sería muy difícil justificar su uso. En el proceso, se realizó la caracterización térmica y energética de aplicaciones con PCM, tanto opacas como traslúcidas. Además, se ha encontrado que las aplicaciones con PCM son capaces de aumentar la eficiencia energética inclusive en recintos con diseños optimizados, demostrando ser una de las estrategias adecuadas para lograr el muy alto desempeño energético requerido en los edificios energía nula. ABSTRACT The main motivation for choosing the theme of the thesis is our energy and environmental reality. And more specifically, the urgent need to respond to this reality from the building sector. This is why, the work start with the search of passive solutions that help reduce energy consumption and C02 emissions of buildings, in both new and existing ones. The object of study is innovative applications based on the use of responsive materials, with bidirectional thermal memory. Energy is an essential element for development. However, the predominant energy model, based primarily on the use of fossil fuels, is one of the major responsible for the environmental deterioration of the planet, the cause of most of the CO2 emissions. Furthermore, reserves of fossil fuels are limited and are concentrated in a few regions of the world, which creates issues related to dependency, competitiveness, and security of supply. Given the large potential for energy savings in the building sector, the European Union in its directives emphasizes the need to improve energy efficiency in buildings. Also, adding the obligation to develop "nearly zero energy" buildings, whose first prerequisite is to achieve a very high energy efficiency. In Spain, buildings are responsible for 31% of primary energy consumption and most of this consumption is related to the used of HVAC systems. One of the most effective measures to reduce demand is to improve the envelope. However, it is necessary to look for additional strategies to further increase the efficiency of new and existing buildings. For the predominant climates in Spain, use of the thermal inertia may be a valid strategy. Nevertheless, its operation is linked to weight and volume of the materials used. This limits their possibilities in the existing buildings energy retrofitting and in the new buildings based on lightweight construction. An alternative is the use of latent heat thermal energy storage applications (LHTES), using phase change materials (PCM). PCM are substances with a high heat of fusion, capable of storing a large amount of thermal energy without requiring significant increases in weight or volume. These features make them ideal for reducing energy consumption associated with thermal conditioning in both new and existing buildings. In the preliminary part of the investigation, it was found that to get optimum utilization of the PCM applications is needed to have a deep understanding of its operation and, in particular, how the system variables affect its performance. Hence, the main objective of this thesis is: to establish the basis for the integral optimization of applications with latent heat thermal energy storage, identifying and validating the most relevant variables. The research comprises of three parts. The first, documentary, systematizing and prioritizing published scientific information. The second, numeric, based on a parametric analysis of an application PCM using thermal simulations. The third, experimental, monitoring the thermal and energy performance of different applications with PCM on real scale test cells. The results provide a complete understanding of the functioning of the evaluated LHTES application. They have allowed to identify their relevant variables, quantify their influence and determine optimum conditions for use as well as situations where it would be very difficult to justify its use. In the process, it was carried out the power and thermal characterization of various opaque and translucent PCM applications. Furthermore, it has been found that applications with PCM can increase the energy efficiency, even in buildings with optimized designs; proving to be one of the appropriate measures to achieve the high energy performance required in zero energy buildings.
Resumo:
Esta tesis trata sobre la construcción modular ligera, dentro del contexto de la eficiencia energética y de cara a los conceptos de nZEB (near Zero Energy Building) y NZEB (Net Zero Energy Building) que se manejan en el ámbito europeo y específicamente dentro del marco regulador de la Directiva 2010/31 UE. En el contexto de la Unión Europea, el sector de la edificación representa el 40% del total del consumo energético del continente. Asumiendo la necesidad de reducir este consumo se han planteado, desde los organismos de dirección europeos, unos objetivos (objetivos 20-20-20) para hacer más eficiente el parque edificatorio. Estos objetivos, que son vinculantes en términos de legislación, comprometen a todos los estados miembros a conseguir la meta de reducción de consumo y emisiones de GEI (Gases de Efecto Invernadero) antes del año 2020. Estos conceptos de construcción modular ligera (CML) y eficiencia energética no suelen estar asociados por el hecho de que este tipo de construcción no suele estar destinada a un uso intensivo y no cuenta con unos cerramientos con niveles de aislamiento de acuerdo a las normativas locales o códigos de edificación de cada país. El objetivo de nZEB o NZEB, e incluso Energy Plus, según sea el caso, necesariamente (y así queda establecido en las normativas), dependerá no sólo de la mejora de los niveles de aislamiento de los edificios, sino también de la implementación de sistemas de generación renovables, independientemente del tipo de sistema constructivo con el que se trabaje e incluso de la tipología edificatoria. Si bien es cierto que los niveles de industrialización de la sociedad tecnológica actual han alcanzado varias de las fases del proceso constructivo - sobre todo en cuanto a elementos compositivos de los edificios- también lo es el hecho de que las cotas de desarrollo conseguidas en el ámbito de la construcción no llegan al nivel de evolución que se puede apreciar en otros campos de las ingenierías como la aeronáutica o la industria del automóvil. Aunque desde finales del siglo pasado existen modelos y proyectos testimoniales de construcción industrializada ligera (CIL) e incluso ya a principios del siglo XX, ejemplos de construcción modular ligera (CML), como la Casa Voisin, la industrialización de la construcción de edificios no ha sido una constante progresiva con un nivel de comercialización equiparable al de la construcción masiva y pesada. Los términos construcción industrializada, construcción prefabricada, construcción modular y construcción ligera, no siempre hacen referencia a lo mismo y no siempre son sinónimos entre sí. Un edificio puede ser prefabricado y no ser modular ni ligero y tal es el caso, por poner un ejemplo, de la construcción con paneles de hormigón prefabricado. Lo que sí es una constante es que en el caso de la construcción modular ligera, la prefabricación y la industrialización, casi siempre vienen implícitas en muchos ejemplos históricos y actuales. Con relación al concepto de eficiencia energética (nZEB o incluso NZEB), el mismo no suele estar ligado a la construcción modular ligera y/o ligera industrializada; más bien se le ve unido a la idea de cerramientos masivos con gran inercia térmica propios de estándares de diseño como el Passivhaus; y aunque comúnmente a la construcción ligera se le asocian otros conceptos que le restan valor (corta vida útil; función y formas limitadas, fuera de todo orden estético; limitación en los niveles de confort, etc.), los avances que se van alcanzando en materia de tecnologías para el aprovechamiento de la energía y sistemas de generación renovables, pueden conseguir revertir estas ideas y unificar el criterio de eficiencia + construcción modular ligera. Prototipos y proyectos académicos– como el concurso Solar Decathlon que se celebra desde el año 2002 promovido por el DOE (Departamento de Energía de los Estados Unidos), y que cuenta con ediciones europeas como las de los años 2010 y 2012, replantean la idea de la construcción industrializada, modular y ligera dentro del contexto de la eficiencia energética, con prototipos de viviendas de ± 60m2, propuestos por las universidades concursantes, y cuyo objetivo es alcanzar y/o desarrollar el concepto de NZEB (Net Zero Energy Building) o edificio de energía cero. Esta opción constructiva no sólo representa durabilidad, seguridad y estética, sino también, rapidez en la fabricación y montaje, además de altas prestaciones energéticas como se ha podido demostrar en las sucesivas ediciones del Solar Decathlon. Este tipo de iniciativas de desarrollo de tecnologías constructivas, no sólo apuntan a la eficiencia energética sino al concepto global de energía neta, Energía plus o cero emisiones de CO2. El nivel de emisiones por la fabricación y puesta en obra de los materiales de construcción depende, en muchos casos, no solo de la propia naturaleza del material, sino también de la cantidad de recursos utilizados para producir una unidad de medida determinada (kg, m3, m2, ml, etc). En este sentido podría utilizarse, en muchos casos, el argumento válido de que a menos peso, y a menos tamaño, menos emisiones globales de gases de efecto invernadero y menos contaminación. Para el trabajo de investigación de esta tesis se han tomado como referencias válidas para estudio, prototipos tanto de CML (Modular 3D) como de CIL (panelizado y elementos 2D), dado que para los fines de análisis de las prestaciones energéticas de los materiales de cerramiento, ambos sistemas son equiparables. Para poder llegar a la conclusión fundamental de este trabajo de tesis doctoral - que consiste en demostrar la viabilidad tecnológica/ industrial que supone la combinación de la eficiencia energética y la construcción modular ligera - se parte del estudio del estado de la técnica ( desde la selección de los materiales y los posibles procesos de industrialización en fábrica, hasta su puesta en obra, funcionamiento y uso, bajo los conceptos de consumo cero, cero emisiones de carbono y plus energético). Además -y con un estado de la técnica que identifica la situación actual- se llevan a cabo pruebas y ensayos con un prototipo a escala natural y células de ensayo, para comprobar el comportamiento de los elementos compositivos de los mismos, frente a unas condicionantes climáticas determinadas. Este tipo de resultados se contrastan con los obtenidos mediante simulaciones informáticas basadas en los mismos parámetros y realizadas en su mayoría mediante métodos simplificados de cálculos, validados por los organismos competentes en materia de eficiencia energética en la edificación en España y de acuerdo a la normativa vigente. ABSTRACT This thesis discusses lightweight modular construction within the context of energy efficiency in nZEB (near Zero Energy Building) and NZEB (Net Zero Energy Building) both used in Europe and, specifically, within the limits of the regulatory framework of the EU Directive 2010/31. In the European Union the building sector represents 40% of the total energy consumption of the continent. Due to the need to reduce this consumption, European decision-making institutions have proposed aims (20-20-20 aims) to render building equipment more efficient. These aims are bound by law and oblige all member States to endeavour to reduce consumption and GEI emissions before the year 2020. Lightweight modular construction concepts and energy efficiency are not generally associated because this type of building is not normally meant for intensive use and does not have closures with insulation levels which fit the local regulations or building codes of each country. The objective of nZEB or NZEB and even Energy Plus, depending on each case, will necessarily be associated (as established in the guidelines) not only with the improvement of insulation levels in buildings, but also with the implementation of renewable systems of generation, independent of the type of building system used and of the building typology. Although it is true that the levels of industrialisation in the technological society today have reached several of the building process phases - particularly in the composite elements of buildings - it is also true that the quotas of development achieved in the area of construction have not reached the evolutionary levelfound in other fields of engineering, such as aeronautics or the automobile industry. Although there have been models and testimonial projects of lightweight industrialised building since the end of last century, even going back as far as the beginning of the XX century with examples of lightweight modular construction such as the Voisin House, industrialisation in the building industry has not been constant nor is its comercialisation comparable to massive and heavy construction. The terms industrialised building, prefabricated building, modular building and lightweight building, do not always refer to the same thing and they are not always synonymous. A building can be prefabricated yet not be modular or lightweight. To give an example, this is the case of building with prefabricated concrete panels. What is constant is that, in the case of lightweight modular construction, prefabrication and industrialisation are almost always implicit in many historical and contemporary examples. Energy efficiency (nZEB or even NZEB) is not normally linked to lightweight modular construction and/or industrialised lightweight; rather, it is united to the idea of massive closureswith high thermal inertia typical of design standards such as the Passive House; and although other concepts that subtract value from it are generally associated with lightweight building (short useful life, limited forms and function, inappropriate toany aesthetic pattern; limitation in comfort levels, etc.), the advances being achieved in technology for benefitting from energy and renewable systems of generation may well reverse these ideas and unify the criteria of efficiency + lightweight modular construction. Academic prototypes and projects - such as the Solar Decathlon competition organised by the US Department of Energy and celebrated since 2002, with its corresponding European events such as those held in 2010 and 2012, place a different slant on the idea of industrialised, modular and lightweight building within the context of energy efficiency, with prototypes of homes measuring approximately 60m2, proposed by university competitors, whose aim is to reach and/or develop the NZEB concept, or the zero energy building. This building option does not only signify durability, security and aesthetics, but also fast manufacture and assembly. It also has high energy benefits, as has been demonstrated in successive events of the Solar Decathlon. This type of initiative for the development of building technologies, does not only aim at energy efficiency, but also at the global concept of net energy, Energy Plus and zero CO2 emissions. The level of emissions in the manufacture and introduction of building materials in many cases depends not only on the inherent nature of the material, but also on the quantity of resources used to produce a specific unit of measurement (kg, m3, m2, ml, etc.). Thus in many cases itcould be validly arguedthat with less weight and smaller size, there will be fewer global emissions of greenhouse effect gases and less contamination. For the research carried out in this thesis prototypes such as the CML (3D Module) and CIL (panelled and elements) have been used as valid study references, becauseboth systems are comparablefor the purpose of analysing the energy benefits of closure materials. So as to reach a basic conclusion in this doctoral thesis - that sets out to demonstrate the technological/industrial viability of the combination of energy efficiency and lightweight modular construction - the departure point is the study of the state of the technique (from the selection of materials and the possible processes of industrialisation in manufacture, to their use on site, functioning and use, respecting the concepts of zero consumption, zero emissions of carbon and Energy Plus). Moreover, with the state of the technique identifying the current situation, tests and practices have been carried out with a natural scale prototype and test cells so as to verify the behaviour of the composite elements of these in certain climatic conditions. These types of result are contrasted with those obtained through computer simulation based on the same parameters and done, principally, using simplified methods of calculation, validated by institutions competent in energy efficiency in Spanish building and in line with the rules in force.
Resumo:
The urban microclimate plays an important role in building energy consumption and thermal comfort in outdoor spaces. Nowadays, cities need to increase energy efficiency, reduce pollutant emissions and mitigate the evident lack of sustainability. In light of this, attention has focused on the bioclimatic concepts use in the urban development. However, the speculative unsustainability of the growth model highlights the need to redirect the construction sector towards urban renovation using a bioclimatic approach. The public space plays a key role in improving the quality of today’s cities, especially in terms of providing places for citizens to meet and socialize in adequate thermal conditions. Thermal comfort affects perception of the environment, so microclimate conditions can be decisive for the success or failure of outdoor urban spaces and the activities held in them. For these reasons, the main focus of this work is on the definition of bioclimatic strategies for existing urban spaces, based on morpho-typological components, urban microclimate conditions and comfort requirements for all kinds of citizens. Two case studies were selected in Madrid, in a social housing neighbourhood constructed in the 1970s based on Rational Architecture style. Several renovation scenarios were performed using a computer simulation process based in ENVI-met and diverse microclimate conditions were compared. In addition, thermal comfort evaluation was carried out using the Universal Thermal Climate Index (UTCI) in order to investigate the relationship between microclimate conditions and thermal comfort perception. This paper introduces the microclimate computer simulation process as a valuable support for decision-making for neighbourhood renovation projects in order to provide new and better solutions according to the thermal quality of public spaces and reducing energy consumption by creating and selecting better microclimate areas.
Resumo:
Las redes del futuro, incluyendo las redes de próxima generación, tienen entre sus objetivos de diseño el control sobre el consumo de energía y la conectividad de la red. Estos objetivos cobran especial relevancia cuando hablamos de redes con capacidades limitadas, como es el caso de las redes de sensores inalámbricos (WSN por sus siglas en inglés). Estas redes se caracterizan por estar formadas por dispositivos de baja o muy baja capacidad de proceso y por depender de baterías para su alimentación. Por tanto la optimización de la energía consumida se hace muy importante. Son muchas las propuestas que se han realizado para optimizar el consumo de energía en este tipo de redes. Quizás las más conocidas son las que se basan en la planificación coordinada de periodos de actividad e inactividad, siendo una de las formas más eficaces para extender el tiempo de vida de las baterías. La propuesta que se presenta en este trabajo se basa en el control de la conectividad mediante una aproximación probabilística. La idea subyacente es que se puede esperar que una red mantenga la conectividad si todos sus nodos tienen al menos un número determinado de vecinos. Empleando algún mecanismo que mantenga ese número, se espera que se pueda mantener la conectividad con un consumo energético menor que si se empleara una potencia de transmisión fija que garantizara una conectividad similar. Para que el mecanismo sea eficiente debe tener la menor huella posible en los dispositivos donde se vaya a emplear. Por eso se propone el uso de un sistema auto-adaptativo basado en control mediante lógica borrosa. En este trabajo se ha diseñado e implementado el sistema descrito, y se ha probado en un despliegue real confirmando que efectivamente existen configuraciones posibles que permiten mantener la conectividad ahorrando energía con respecto al uso de una potencia de transmisión fija. ABSTRACT. Among the design goals for future networks, including next generation networks, we can find the energy consumption and the connectivity. These two goals are of special relevance when dealing with constrained networks. That is the case of Wireless Sensors Networks (WSN). These networks consist of devices with low or very low processing capabilities. They also depend on batteries for their operation. Thus energy optimization becomes a very important issue. Several proposals have been made for optimizing the energy consumption in this kind of networks. Perhaps the best known are those based on the coordinated planning of active and sleep intervals. They are indeed one of the most effective ways to extend the lifetime of the batteries. The proposal presented in this work uses a probabilistic approach to control the connectivity of a network. The underlying idea is that it is highly probable that the network will have a good connectivity if all the nodes have a minimum number of neighbors. By using some mechanism to reach that number, we hope that we can preserve the connectivity with a lower energy consumption compared to the required one if a fixed transmission power is used to achieve a similar connectivity. The mechanism must have the smallest footprint possible on the devices being used in order to be efficient. Therefore a fuzzy control based self-adaptive system is proposed. This work includes the design and implementation of the described system. It also has been validated in a real scenario deployment. We have obtained results supporting that there exist configurations where it is possible to get a good connectivity saving energy when compared to the use of a fixed transmission power for a similar connectivity.
Resumo:
La obra de Emilio Pérez Piñero que se desarrolla entre los años 1961 y 1972 año en el que muere en un accidente de tráfico volviendo de Figueras, se centra principalmente en artefactos desplegables y desmontables, ejecutando prototipos que en el presente trabajo se han dividido en dos grupos; la cúpula reticular y la infraestructura. No pudo por tanto acudir al Congreso de 1972 de la UIA a recoger el premio Auguste Perret a la innovación tecnológica, que en años anteriores habían recibido Félix Candela, Jean Prouvé, Hans Scharoun o Frei Otto, y que en aquella ocasión tuvo que recoger su viuda. Parámetros como el de la movilidad, indeterminación, intercambiabilidad, obsolescencia y otros que se analizan en el presente trabajo, aparecen a lo largo de toda su obra ya que muchos de sus artefactos están ubicados en no-lugares y tienen un carácter itinerante y por tanto se hace indispensable su rápido montaje y desmontaje, que unas veces se resuelve mediante la desmontabilidad y otras con la plegabilidad de éstos. Aunque pueda parecer Piñero una figura autárquica, lo cierto es que durante la década donde concentra su trabajo se produce una explosión en torno a al arquetipo que será denominado de forma genérica `artefacto´, ligado conceptualmente a los parámetros que aquí se definen. Entendemos artefacto como objeto material realizado por una o varias personas para cumplir una función, es sinónimo de máquina y aparato y deriva de las palabras latinas ars o artis (técnica) y facto (hecho), para designar a los objetos cuya fabricación requiere alguna destreza. El término latino `ars´ engloba a las técnicas y a las artes, lo que no ocurre con el término castellano arte que deriva de él. Los movimientos utópicos que comparte la década con Piñero, utilizan el arquetipo infraestructural, ligero y high tech, para a través de una arquitectura más ligada a la ciencia ficción, realizar una crítica al Movimiento Moderno institucionalizado, todos ellos comparten cierta obsesión por la movilidad, ligada ésta a la idea de espacio flexible, dinámico, nómada. Este concepto de neo-nomadismo, que representa un habitar dinámico, aglutina las nuevas formas de vivir donde la movilidad social y geográfica son habituales. El nomadismo, por otra parte se entiende como sinónimo de democracia y libertad. La arquitectura pasa de ser pesada, estática, permanente a ser un elemento dinámico en continuo movimiento. A veces con connotaciones biológicas se asimilan los artefactos a organismos vivos y les confieren dichas propiedades de crecimiento y autonomía energética, acumulándose en torno a megaestructuras, donde quedan `enchufados´. En este intento de dotar movilidad a lo inmueble, se buscan estructuras vivas y modificables que crecen en una asimilación de las leyes naturales utilizando los parámetros de metamorfosis, simbiosis y cambio. Estos movimientos de vanguardia tienen también ciertas connotaciones políticas y sociales basadas en la libertad y la movilidad y reniegan del consumismo institucionalizado, de la arquitectura como instrumento de consumo, como objeto de usar en la cultura de masas. El carácter político de la autogestión, de la customización como parámetro proyectual, de la autosuficiencia energética, que anticipa la llegada de la crisis energética del año 1973. Objeto de este trabajo será relacionar los conceptos que aparecen fuertemente en el entorno de la década de los años sesenta del siglo XX, en el trabajo de Emilio Pérez Piñero. Parámetros encontrados como conceptos en los grupos de vanguardia y utopía a su vez fuertemente influenciados por las figuras del ingeniero Richard Buckminster Fuller y del arquitecto Konrad Wachsmann. Se analizará que posible influencia tiene la obra de Fuller, principalmente el prototipo denominado cúpula reticular, en la obra de Pérez Piñero y sus coetáneos analizando sus pensamientos teóricos en torno a parámetros como la energía, principalmente en las teorías relativas a Synergetics. El término inventado por Richard B. Fuller es una contracción de otro más largo que en inglés agrupa tres palabras; synergetic-energetic geometry. La definición de sinergia es la cooperación, es decir es el resultado de la acción conjunta de dos o más causas, pero con un efecto superior a la suma de estas causas. El segundo término, energetics geometry, que traducido sería geometría energética hace referencia en primer lugar a la geometría; ya que desarrolla el sistema de referencia que utiliza la naturaleza para construir sus sistemas y en segundo lugar a la energía; ya que además debe ser el sistema que establezca las relaciones más económicas utilizando el mínimo de energía. Por otro lado se analiza la repercusión del prototipo denominado Infraestructura, término acuñado por Yona Friedman y basado estructuralmente y conceptualmente en los desarrollos sobre grandes estructuras de Konrad Wachsmann. El arquitecto alemán divulga su conocimiento en seminarios impartidos por todo el mundo como el que imparte en Tokio y se denomina Wachsmann´s Seminar donde participan algunos de los componentes del grupo Metabolista que sorprenderán al mundo con sus realizaciones en la exposición de Osaka de 1970. El intervalo temporal entre 1961 hasta 1972 hace referencia a la horquilla donde Pérez Piñero realiza su obra arquitectónica, que comienza en 1961 cuando gana el concurso convocado en Londres por la UIA (Unión Internacional de Arquitectos) con el proyecto conocido como Teatro Ambulante, hasta 1972 que es cuando fallece volviendo de Figueras donde está realizando dos encargos de Salvador Dalí; la cubrición del escenario del futuro Teatro-Museo Salvador Dalí y la Vidriera Hipercúbica que debía cerrar la boca de tal escenario. Bajo el título de `Artefactos energéticos. De Fuller a Piñero (1961-1972)´, se presenta esta Tesis doctoral, que tiene la intención de vincular la obra de Emilio Pérez Piñero con la de las neo vanguardias producidas por una serie de arquitectos que operan en el ámbito internacional. Estas vinculaciones se producen de una forma general, donde a través de una serie de estrategias según la metodología que posteriormente se describe se buscan relaciones de la obra del autor español con algunos de los movimientos más significativos que aparecen en dicha década y de manera específica estableciendo relaciones con las obras y pensamientos de los autores que pertenecen a estos movimientos y donde estas relaciones se hacen más evidentes. El objeto del presente trabajo es analizar y explicar la obra del arquitecto Emilio Pérez Piñero, que espacialmente se localiza en el territorio español, desde el punto de vista de estos movimientos para posteriormente poder determinar si existen puntos en común y si el arquitecto español no solo comparte la década temporalmente sino también conceptualmente y por tanto utiliza el ideario que utilizan sus coetáneos que forman parte de las neovanguardias de los años sesenta de siglo XX. ABSTRACT ABSTRACT The Work of Emilio Perez Piñero was developed between the years 1961 and 1972 when he died in a car accident coming back from Figueres, where he was building a geodesic dome to close the building that enclose the Dali’s museum. All his Work is mainly centered in artifact that could be collapsible and removable, taking the two prototypes that are described in this work as a recurrent element in all his creation. These are the reticular dome and the infrastructure that are very influenced by the work from Richard B. Fuller and Konrad Wachsmann. Emilio Pérez Piñero could not receive the Auguste Perret Prize in 1972 awarded by the UIA that years before have received architects as Felix Candela, Jean Prouvé, Hans Scharoun or Frei Otto, and this time Pérez Piñero´s wife will accept it because of his death. Parameters like mobility, changeability, expendability, indetermination and others appear currently in his Work. All the inventions that Piñero had been patented and all of the artifacts that he created are usually located in no-places, because they do have a shifting identity. This kind of building has to be quickly set on site, and this problem has to be solved in term of foldability or demounting. In the decade where his work focuses, an explosion has occurred around this archetype to be generally called artifact that is usually linked to mobility. We understand artifact as a material object made by one or more people to work in a particular way. It is sometimes equated with the terms machinery and apparatus and it is derived from the Latin word `ars´ or `artis´, what means techniques and `facto´ (fact). And we use this term to refer to objects whose manufacture requires the same skill, in fact the Latin word `ars´ covers the techniques and arts, which does not occur with the Castillan term `arte´ that derives from it and means only art. The term neo-nomadic is a relatively new name used for a dynamic life, commonly referred to new forms of life where social and geographical mobility are common. On the other hand nomadic could be understood as a synonymous for democracy and freedom. The architecture is not going to be hard and static anymore but a dynamic element in the move. The Neo-avant-garde movement that shares the decade with Piñero uses this infrastructural archetype, which is light and high-tech, to criticize the institutionalized Modern Movement through architecture linked to science fiction. They all share an obsession with mobility, a concept that is connected to the terms `dynamic´, `nomadic´, `flexibile´, etc. Sometimes, with biological connotations, the utopian assimilate the artifacts to living organisms and give them these properties of growth and energy autonomy, and they apparently grow around megastructures where they are plugged. In this attempt to provide mobility to the inertness, living structures and possibility of change are sought in order to make them grow like a living organism and to assimilate the natural laws of growth. According to a definition from architecture provided by Fernández- Galiano who calls it `exosomatic artifact´, he understand architecture as artifact of the human environment that regulates natural energy flows and channels the energy stored in fuels for the benefit of living beings that inhabit. It is also true that during the sixties a new environmental awareness in public opinion is formed and that is due to the exploitation and disproportionate use of energy resources, acceleration of technological processes and mass consumption. Consequently a new concept is born: energy autonomy, it is very close to rational use of natural energy. Such a concept will be culturally assimilated with the requirement of independence not only in the management but also in the building construction until we arrive at energy autonomy. The individuals become energy consumer, which in turn can enter the energy produced in the system to `life in an eco-mode way´. The objectives of this research are analyzing all of these parameters and concepts that are coming into view in the surrounding of the decade and relate them with the Work of Pérez Piñero. Terms strongly present in the avant-garde movements around the decade, a young architect’s generation strongly influenced by Richard B. Fuller and Konrad Wachsmann. However, it will be analyzed how important the influence of Buckminster Fuller's Work was and his theoretical text about energy on the Work of Pérez Piñero and his fellows of the decade. The term Synergetic was invented by Fuller and came from the words synergy and energetic geometry. Synergy is the cooperation or interaction of two or more agents to produce a greater effect than the sum of their separate effects. Energetic geometry is related to the geometries that the Nature is using to build their construction but always using low energy consumption. On the other hand, the influences from Wachsmann around the prototype called Infrastructure have been analyzed. The German architect has developed knowledge around huge structures that he has spread all around the world through seminars that he has been conducted. One of these was the Wachsmann´s seminar in Tokyo, where same of the members of the Metabolist group were taking part of. Later these young architects will surprise the world with his artifacts at the World Exposition in Osaka in 1970. Between 1961 and 1972 Pérez Piñero produced his architectural work. It began in 1961 when he received the first prize with his project Mobile Theatre in the competition organized by the UIA in London. In 1972 the Auguste Perret Prize was granted by the UIA too. He could not accept it because he died before in a car accident when he was coming from Figueres, when he was designing two projects for Dali. With the title `Energetic Artifacts. From Fuller to Piñero (1961- 1972)´, this thesis relates the Work of Emilio Pérez Piñero with the neo avant-garde made by a young architects’ generation who is sharing the time with him. Several strategies have been used to formed relationships between them. They are described in the present work to set up a method that allows us to relate the work and ideas of the architects of the neo avant-garde with the ones from Piñero. This work is intended to analyze and explained the work of Pérez Piñero from the point of view of the international architects’ generation who is operating at the same time and finally to determinate if Piñero is not sharing the time with them but the concepts, ideas and architectural parameters.
Resumo:
La presente tesis doctoral aborda el estudio de un nuevo material mineral, compuesto principalmente por una matriz de yeso (proveniente de un conglomerante industrial basado en sulfato de calcio multifase) y partículas de aerogel de sílice hidrófugo mesoporoso, compatibilizadas mediante un surfactante polimérico, debido a su alto carácter hidrófugo. La investigación se centra en conocer los factores que influyen en las propiedades mecánicas y conductividad térmica del material compuesto generado. Este estudio pretende contribuir al conocimiento sobre el desarrollo de nuevos morteros de elevado aislamiento térmico que puedan ser utilizados en la rehabilitación energética de edificios de viviendas existentes, debido a que estos representan gran parte del consumo energético del parque de viviendas de España, aunque también a nivel internacional. De los materiales utilizados para desarrollar los morteros estudiados, el yeso, además de ser un material muy abundante, especialmente en España, requiere una menor cantidad de energía para la fabricación de un conglomerante (debido a una menor temperatura de fabricación), en comparación con el cemento o la cal, por lo que presenta una menor huella de carbono que estos últimos. Por otro lado, el aerogel de sílice hidrófugo mesoporoso es, de acuerdo con la documentación disponible, el material que posee actualmente la mayor capacidad de aislamiento térmico en el mercado. El desarrollo de nuevos morteros minerales con una capacidad de aislamiento térmico mayor que los materiales aislantes utilizados tradicionalmente, tiene una aplicación relevante en los casos de rehabilitación energética de edificios históricos y patrimoniales, en los que se requiere la aplicación del aislamiento por el interior de la fachada, ya que este tipo de soluciones tienen el inconveniente de reducir el espacio habitable de las áreas involucradas, especialmente en zonas climáticas en las que el aislamiento térmico puede suponer un espesor considerable, por lo que es ideal utilizar materiales de altas prestaciones de aislamiento térmico capaces de aportar el mismo nivel de aislamiento (o incluso mayor), pero en un espesor considerablemente menor. La investigación se desarrolla en tres etapas: bibliográfica, experimental y de simulación. La primera etapa, parte del estudio de la bibliografía existente, relacionada con materiales aislantes, incluyendo soluciones basadas, tanto en morteros aislantes, como en paneles de aislamiento térmico. La segunda, de carácter experimental, se centra en estudiar la influencia de la microestrucrura y macroestructura, del nuevo material mineral, en las propiedades físicas elementales, mecánicas y conductividad térmica del compuesto. La tercera etapa, mediante una simulación del consumo energético, consiste en cuantificar teóricamente el potencial ahorro energético que puede aportar este material en un caso de rehabilitación energética en particular. La investigación experimental se centró principalmente en conocer los factores principales que influyen en las propiedades mecánicas y conductividad térmica de los materiales compuestos minerales desarrollados en esta tesis. Para ello, se llevó a cabo una caracterización de los materiales de estudio, así como el desarrollo de distintas muestras de ensayo, de tal forma que se pudo estudiar, tanto la hidratación del yeso en los compuestos, como su posterior microestructura y macroestructura, aspectos fundamentales para el entendimiento de las propiedades mecánicas y conductividad térmica del compuesto aislante. De este modo, se pudieron conocer y cuantificar, los factores que influyen en las propiedades estudiadas, aportando una base de conocimiento y entendimiento de este tipo de compuestos minerales con aerogel de sílice hidrófugo, no existiendo estudios publicados hasta el momento de finalización de esta tesis, con la aproximación al material propuesta en este estudio, ni con yeso (basado en sulfato de calcio multifase), ni con otro tipo de conglomerantes. Particularmente, se determinó la influencia que tiene la incorporación de partículas de aerogel de sílice hidrófugo, en grandes proporciones en volumen, en un compuesto mineral basado en distintas fases de sulfato de calcio. No obstante, para llevar a cabo las mezclas, fue necesario utilizar un surfactante para compatibilizar este tipo de partículas, con el conglomerante basado en agua. El uso de este tipo de aditivos tiene una influencia, no solo en el aerogel, sino en las propiedades del compuesto en general, dependiendo de su concentración, por lo que se establecieron dos porcentajes de adición: la primera, determinada a partir de la cantidad mínima necesaria para compatibilizar las mezclas (0,1% del agua de amasado), y la segunda, como límite superior, la concentración utilizada habitualmente a nivel industrial para estabilizar burbujas de aire en hormigones espumados (5%). El surfactante utilizado mostró la capacidad de modificar la superficie del aerogel, cambiando el comportamiento de las partículas frente al agua, permitiendo una invasión parcial de su estructura porosa, por parte del agua de amasado. Este comportamiento supone un aumento muy importante en la relación agua/yeso, afectando el hábito cristalino e influenciando negativamente las propiedades mecánicas de la matriz de yeso, presentando un efecto aún notable a mayor concentración de surfactante (5%). En cuanto a las propiedades finales alcanzadas, fue posible lograr un compuesto mineral ultraligero (200 kg/m3), con alrededor de un 60% de aerogel en volumen y de alta capacidad aislante (0,028 W/m•K), presentando una conductividad térmica notablemente menor que los morteros aislantes del mercado, e incluso también menor que la de los aislantes tradicionales basado en las lanas minerales o EPS; no obstante, con la limitante de presentar bajas propiedades mecánicas, condicionando su posible aplicación futura. Entre los factores principales relacionados con las propiedades mecánicas, se encontró que estas dependen exponencialmente del volumen de yeso en el compuesto; no obstante, factores de segundo orden, como el grado de hidratación, o una mejor distribución del conglomerante entre las partículas de aerogel, debido al aumento de la superficie específica del polvo mineral, pueden aumentar las propiedades mecánicas entre el doble y el triple, dependiendo del volumen de aerogel en cuestión. Además, se encontró que el aerogel, en conjunto con el surfactante, es capaz de introducir una gran cantidad de aire (0,70 m3 por cada m3 de aerogel), que unido al agua evaporada (no consumida por el conglomerante durante la hidratación), el volumen de aire total alcanza, generalmente, un 40%, independientemente de la cantidad de aerogel en la mezcla. De este modo, el aire introducido en la matriz desplaza las proporciones en volumen del aerogel y del yeso, disminuyendo, tanto las propiedades mecánicas, como la capacidad aislante de compuesto mineral. Por otro lado, la conductividad térmica mostró tener una dependencia directa de la contribución de las tres fases principales en el compuesto: yeso, aerogel y aire ocluido. De este modo, se pudo desarrollar un modelo matemático, adaptado de uno existente, capaz de calcular, con bastante precisión, la relación de los tres componentes mencionados, en la conductividad térmica de los compuestos, para el rango de volúmenes y materiales utilizados en esta tesis. Finalmente, la simulación del consumo energético realizada a una vivienda típica de España, de los años 1900 a 1959 (basada en muros de ladrillo macizo), para las zonas climáticas estudiadas (A, D y E), permitió observar el potencial ahorro energético que puede aportar este material, dependiendo de su espesor, como aislamiento interior de los muros de fachada. Particularmente, para la zona A, se determinó un espesor óptimo de 1 cm, mientras que para la zona D y E, 3,5 y 3,9 cm respectivamente. En este sentido, el nuevo material estudiado es capaz de disminuir, entre un 35% y un 80%, el espesor de la capa aislante, en comparación con paneles de lana de roca o los morteros minerales de mayor capacidad aislante del mercado español respectivamente. ABSTRACT The present doctoral thesis studies a new mineral-based composite material, composed by a gypsum matrix (based on an industrial multiphase gypsum binder) and mesoporous hydrophobic silica aerogel particles, compatibilized with a polymeric surfactant due to the high hydrophobic character of the insulating particles. This study pretends to contribute to the development of new composite insulating materials that could be used in energy renovation of existing dwellings, in order to reduce their high energy consumption, as they represent a great part of the total energy consumed in Spain, but also internationally. Between the materials used to develop de studied insulating mortars, gypsum, besides being an abundant material, especially in Spain, requires less energy for the manufacture of a mineral binder (due to lower manufacturing temperatures), compared to lime or cement, thus presenting lower carbon footprint. In other hand, the hydrophobic mesoporous silica aerogel, is, according to the existing references, the material with the highest know insulating capacity in the market. The development of new mineral mortars with higher thermal insulation capacity than traditional insulating materials, presents a relevant application in energy retrofitting of historic and cultural heritage buildings, in which implies that the insulating material should be installed as an internal layer, rather than as an external insulating system. This type of solution involves a reduced internal useful area, especially in climatic zones where the demand for thermal insulation is higher, and so the insulating layer thickness, being idealistic to use materials with very high insulating properties, in order to reach same insulating level (or higher), but in lower thickness than the provided by traditional insulating materials. This research is developed in three main stages: bibliographic, experimental and simulation. The first stage starts by studying the existing references regarding thermally insulating materials, including existing insulating mortars and insulating panels. The second stage, mainly experimental, is centered in the study of the the influence of the microstructure and macrostructure in the physical and mechanical properties, and also in the thermal conductivity of the new mineral-based material. The thirds stage, through energy simulation, consists in theoretically quantifying the energy savings potential that can provide this type of insulating material, in a particular energy retrofitting case study. The experimental research is mainly focused in the study of the factors that influence the mechanical properties and the thermal conductivity of the thermal insulating mineral composites developed in this thesis. For this, the characterization of the studied materials has been performed, as well as the development of several experimental samples, in order to study the hydration of the mineral binder within the composites, but also the final microstructure and macrostructure, fundamental aspects for the understanding of the composite’s mechanical and insulating properties. Thus, is was possible to determine and quantify the factors that influence the studied material properties, providing a knowledge base and understanding of mineral composites that comprises mesoporous hydrophobic silica aerogel particles, being the first study up to date regarding the specific approach of the present study, regarding not just multiphase calcium sulfate plaster, but also other mineral binders. Particularly, the influence of the incorporation of hydrophobic silica aerogel particles, in high volume ratios into a mineral compound, based on different phases of calcium sulfate has been determined. However, to perform mixing, it is necessary to use a surfactant in order to compatibilize these particles with the water-based mineral binder. The use of such additives has an influence, not only in the aerogel, but the overall properties of the compound, so two different surfactant concentration has been studied: the first, the minimum amount of surfactant (used in this thesis) in order to develop the slurries (0.1% concentration of the mixing water), and the second, as the upper limit, the concentration usually used industrially to stabilize air bubbles in foamed concrete (5%). One of the side effects of using such additive, was the modification of the aerogel particles, by changing their behavior in respect to water, generating a partial invasion of the aerogel’s porous structure, by the mixing water. This behavior produces a very important increase in water/binder ratios, affecting the crystal habit and negatively influencing the mechanical properties of the gypsum matrix. This effect further increased when a higher concentration of surfactant (5%) is used. Regarding final materials properties, it was possible to achieve an ultra-lightweight mineral composite (200 kg/m3), with around 60% by volume of aerogel, presenting a very high insulating capacity (0.028 W/m•K), a noticeable lower thermal conductivity compared to the insulating mortars and traditional thermal insulating panels on the market, such as mineral wool or EPS; however, the limiting factor for future’s material application in buildings, is related to the very low mechanical properties achieved. Among the main factors related to the mechanical properties, it has been found an exponential correlation to the volume of gypsum in the composite. However, second-order factors such as the degree of hydration, or a better distribution of the binder between the aerogel particles, due to the increased surface area of the mineral powder, can increase the mechanical properties between two to three times, depending aerogel volume involved. In addition, it was found that the aerogel, together with the surfactant, is able to entrain a large amount of air volume (around 0.70 m3 per m3 of aerogel), which together with the evaporated water (not consumed by the binder during hydration), can reach generally around 40% of entrained air within the gypsum matrix, regardless of the amount of aerogel in the mixture. Thus, the entrained air into the matrix displaces the volume proportions of the aerogel and gypsum, reducing both mechanical and insulating properties of the mineral composite. On the other hand, it has been observed a direct contribution of three main phases into the thermal conductivity of the composite: gypsum, aerogel and entrained air. Thus, it was possible to develop a mathematical model (adapted from an existing one), capable of calculating quite accurate the thermal conductivity of such mineral composites, from the ratio these three components and for the range of volumes and materials used in this thesis. Finally, the energy simulation performed to a typical Spanish dwelling, from the years 1900 to 1959 (mainly constructed with massive clay bricks), within three climatic zones of Spain (A, D and E), showed the energy savings potential that can provide this type of insulating material, depending on the thickness of the applied layer. Particularly, for the climatic A zone, it has been found an optimal layer thickness of 1 cm, while for zone D and E, 3.5 and 3.9 cm respectively. In this manner, the new studied materials is capable of decreasing the thickness of the insulating layer by 35% and 80%, compared with rock wool panels or mineral mortars with the highest insulating performance of the Spanish market respectively.
Resumo:
A eficiência e a racionalidade energética da iluminação pública têm relevante importância no sistema elétrico, porque contribui para diminuir a necessidade de investimentos na construção de novas fontes geradoras de energia elétrica e nos desperdícios energéticos. Apresenta-se como objetivo deste trabalho de pesquisa o desenvolvimento e aplicação do IDE (índice de desempenho energético), fundamentado no sistema de inferência nebulosa e indicadores de eficiência e racionalidade de uso da energia elétrica. A opção em utilizar a inferência nebulosa deve-se aos fatos de sua capacidade de reproduzir parte do raciocínio humano, e estabelecer relação entre a diversidade de indicadores envolvidos. Para a consecução do sistema de inferência nebulosa, foram definidas como variáveis de entrada: os indicadores de eficiência e racionalidade; o método de inferência foi baseado em regras produzidas por especialista em iluminação pública, e como saída um número real que caracteriza o IDE. Os indicadores de eficiência e racionalidade são divididos em duas classes: globais e específicos. Os indicadores globais são: FP (fator de potência), FC (fator de carga) e FD (fator de demanda). Os indicadores específicos são: FU (fator de utilização), ICA (consumo de energia por área iluminada), IE (intensidade energética) e IL (intensidade de iluminação natural). Para a aplicação deste trabalho, foi selecionada e caracterizada a iluminação pública da Cidade Universitária \"Armando de Salles Oliveira\" da Universidade de São Paulo. Sendo assim, o gestor do sistema de iluminação, a partir do índice desenvolvido neste trabalho, dispõe de condições para avaliar o uso da energia elétrica e, desta forma, elaborar e simular estratégias com o objetivo de economizá-la.
Resumo:
Evacuation route planning is a fundamental task for building engineering projects. Safety regulations are established so that all occupants are driven on time out of a building to a secure place when faced with an emergency situation. As an example, Spanish building code requires the planning of evacuation routes on large and, usually, public buildings. Engineers often plan these routes on single building projects, repeatedly assigning clusters of rooms to each emergency exit in a trial-and-error process. But problems may arise for a building complex where distribution and use changes make visual analysis cumbersome and sometimes unfeasible. This problem could be solved by using well-known spatial analysis techniques, implemented as a specialized software able to partially emulate engineer reasoning. In this paper we propose and test an easily reproducible methodology that makes use of free and open source software components for solving a case study. We ran a complete test on a building floor at the University of Alicante (Spain). This institution offers a web service (WFS) that allows retrieval of 2D geometries from any building within its campus. We demonstrate how geospatial technologies and computational geometry algorithms can be used for automating the creation and optimization of evacuation routes. In our case study, the engineers’ task is to verify that the load capacity of each emergency exit does not exceed the standards specified by Spain’s current regulations. Using Dijkstra’s algorithm, we obtain the shortest paths from every room to the most appropriate emergency exit. Once these paths are calculated, engineers can run simulations and validate, based on path statistics, different cluster configurations. Techniques and tools applied in this research would be helpful in the design and risk management phases of any complex building project.