988 resultados para Probabilidade geometrica


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work we present a mathematical and computational modeling of electrokinetic phenomena in electrically charged porous medium. We consider the porous medium composed of three different scales (nanoscopic, microscopic and macroscopic). On the microscopic scale the domain is composed by a porous matrix and a solid phase. The pores are filled with an aqueous phase consisting of ionic solutes fully diluted, and the solid matrix consists of electrically charged particles. Initially we present the mathematical model that governs the electrical double layer in order to quantify the electric potential, electric charge density, ion adsorption and chemical adsorption in nanoscopic scale. Then, we derive the microscopic model, where the adsorption of ions due to the electric double layer and the reactions of protonation/ deprotanaç~ao and zeta potential obtained in modeling nanoscopic arise in microscopic scale through interface conditions in the problem of Stokes and Nerst-Planck equations respectively governing the movement of the aqueous solution and transport of ions. We developed the process of upscaling the problem nano/microscopic using the homogenization technique of periodic structures by deducing the macroscopic model with their respectives cell problems for effective parameters of the macroscopic equations. Considering a clayey porous medium consisting of kaolinite clay plates distributed parallel, we rewrite the macroscopic model in a one-dimensional version. Finally, using a sequential algorithm, we discretize the macroscopic model via the finite element method, along with the interactive method of Picard for the nonlinear terms. Numerical simulations on transient regime with variable pH in one-dimensional case are obtained, aiming computational modeling of the electroremediation process of clay soils contaminated

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper has two objectives: (i) conducting a literature search on the criteria of uniqueness of solution for initial value problems of ordinary differential equations. (ii) a modification of the method of Euler that seems to be able to converge to a solution of the problem, if the solution is not unique

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In general, an inverse problem corresponds to find a value of an element x in a suitable vector space, given a vector y measuring it, in some sense. When we discretize the problem, it usually boils down to solve an equation system f(x) = y, where f : U Rm ! Rn represents the step function in any domain U of the appropriate Rm. As a general rule, we arrive to an ill-posed problem. The resolution of inverse problems has been widely researched along the last decades, because many problems in science and industry consist in determining unknowns that we try to know, by observing its effects under certain indirect measures. Our general subject of this dissertation is the choice of Tykhonov´s regulaziration parameter of a poorly conditioned linear problem, as we are going to discuss on chapter 1 of this dissertation, focusing on the three most popular methods in nowadays literature of the area. Our more specific focus in this dissertation consists in the simulations reported on chapter 2, aiming to compare the performance of the three methods in the recuperation of images measured with the Radon transform, perturbed by the addition of gaussian i.i.d. noise. We choosed a difference operator as regularizer of the problem. The contribution we try to make, in this dissertation, mainly consists on the discussion of numerical simulations we execute, as is exposed in Chapter 2. We understand that the meaning of this dissertation lays much more on the questions which it raises than on saying something definitive about the subject. Partly, for beeing based on numerical experiments with no new mathematical results associated to it, partly for being about numerical experiments made with a single operator. On the other hand, we got some observations which seemed to us interesting on the simulations performed, considered the literature of the area. In special, we highlight observations we resume, at the conclusion of this work, about the different vocations of methods like GCV and L-curve and, also, about the optimal parameters tendency observed in the L-curve method of grouping themselves in a small gap, strongly correlated with the behavior of the generalized singular value decomposition curve of the involved operators, under reasonably broad regularity conditions in the images to be recovered

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We present a dependent risk model to describe the surplus of an insurance portfolio, based on the article "A ruin model with dependence between claim sizes and claim intervals"(Albrecher and Boxma [1]). An exact expression for the Laplace transform of the survival function of the surplus is derived. The results obtained are illustrated by several numerical examples and the case when we ignore the dependence structure present in the model is investigated. For the phase type claim sizes, we study by the survival probability, considering this is a class of distributions computationally tractable and more general

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The central objective of a study Non-Homogeneous Markov Chains is the concept of weak and strong ergodicity. A chain is weak ergodic if the dependence on the initial distribution vanishes with time, and it is strong ergodic if it is weak ergodic and converges in distribution. Most theoretical results on strong ergodicity assume some knowledge of the limit behavior of the stationary distributions. In this work, we collect some general results on weak and strong ergodicity for chains with space enumerable states, and also study the asymptotic behavior of the stationary distributions of a particular type of Markov Chains with finite state space, called Markov Chains with Rare Transitions

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior

Relevância:

10.00% 10.00%

Publicador:

Resumo:

FUNDAMENTOS: Acrocórdons são lesões dermatológicas comuns na população e estão associados ao diabetes mellitus, à obesidade, à resistência insulínica e à aterosclerose. A identificação precoce de pacientes com resistência insulínica pode ter papel preventivo primário. OBJETIVO: Avaliar a associação entre presença de acrocórdons cervicais ou axilares e resistência insulínica. MÉTODOS: Estudo transversal com pacientes dermatológicos adultos atendidos em hospital universitário. Casos foram definidos como portadores de mais de cinco acrocórdons cervicais e/ou axilares. A resistência insulínica foi estimada pelo índice HOMA-IR. Resultados foram ajustados pelas demais covariáveis de risco para resistência insulínica conhecidos, a partir de regressão logística múltipla. RESULTADOS: Avaliaram-se 98 casos e 103 controles, que não diferiram entre si quanto à idade ou ao gênero. Acrocórdons se associaram diretamente aos valores de HOMA-IR (Odds Ratio = 1,4), hipertrigliceridemia e índice de massa corpórea, independentemente do ajuste por diabetes mellitus, idade, fototipo, gênero, história de diabetes mellitus familiar e relação cintura/quadril. Níveis qualitativamente elevados de HOMA-IR (> 3,8) também evidenciaram associação significativa (Índice de probabilidade = 7,5). CONCLUSÕES: Presença de múltiplos acrocórdons se associou à resistência insulínica, independentemente dos demais fatores de risco.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A research project is being developed by PPGG/UFRN and PETROBRAS in the Xaréu Oil Field located in Ceará Basin, Northeastern Brazil. The objective of the research is to characterize a fractured carbonate reservoir, the Trairi Limestone, in order to drill a borehole with two horizontal legs taking advantage of the natural fracture system to enhance the oil recovery. The present master thesis is part of this research and its contribution is to estimate fault orientation from unoriented cores, using the method proposed by Hesthammer & Henden (2000). In order to orient a fault cutting a bed observed in the core, the bed should be previously oriented. As additional constraint to orient the bed, we use regional bedding orientation obtained from structure maps of Trairi Limestone. Because the number of cores drilled from the Trairi Limestone was too small, we analyzed all cores from the field. As geologic constraint, we admit that all faults were formed as result of the South America and Africa separation, in the context of a regional dextral strike-slip fault formation. In this context, secondary faults are manly T and R faults according Riedel s classification. We analyzed 236.5 m of cores. The dip of bedding varies from 0o to 8o, being the most frequent value equal to 2o. We interpret this result as evidence that the deformation process was manly ruptil. 77 faults were identified in the cores. These faults strike manly to NW and NE with dips, in general, inside the interval 700 - 900. We suggest that the horizontal legs of the borehole should be oriented to NW and NE in order to improve the probability of intercepting open fractures and faults

Relevância:

10.00% 10.00%

Publicador:

Resumo:

CONTEXTO E OBJETIVO: A falta de consenso sobre os protocolos de rastreamento e diagnóstico do diabetes gestacional, associada às dificuldades na realização do teste oral simplificado do diabete gestacional (o teste de tolerância a 100 g de glicose, considerado padrão-ouro) justificam a comparação com alternativas. O objetivo deste trabalho é comparar o teste padrão-ouro a dois testes de rastreamento: associação de glicemia de jejum e fatores de risco (GJ + FR) e o teste oral simplificado de tolerância a 50 g de glicose (TTG 50 g), com o teste de tolerância a 100 g de glicose (TTG 100 g). TIPO DE ESTUDO E LOCAL: Estudo de coorte longitudinal, prospectivo, realizado no Serviço de Ginecologia e Obstetrícia do Hospital Universitário da Universidade Federal de Mato Grosso do Sul. MÉTODOS: 341 gestantes foram submetidas aos três testes. Calcularam-se os índices de sensibilidade (S), especificidade (E), valores preditivos (VPP e VPN), razões de probabilidade (RPP e RPN) e resultados falsos (FP e FN), positivos e negativos da associação GJ + FR e do TTG 50 g em relação ao TTG 100 g. Compararam-se as médias das glicemias de uma hora pós-sobrecarga (1hPS) com 50 e 100 g. Na análise estatística, empregou-se o teste t de Student, com limite de significância de 5%. RESULTADOS: A associação GJ + FR encaminhou mais gestantes (53,9%) para a confirmação diagnóstica que o TTG 50 g (14,4%). Os dois testes foram equivalentes nos índices de S (86,4 e 76,9%), VPN (98,7 e 98,9%), RPN (0,3 e 0,27) e FN (15,4 e 23,1%). As médias das glicemias 1hPS foram semelhantes, 106,8 mg/dl para o TTG 50 g e 107,5 mg/dl para o TTG 100 g. CONCLUSÕES: Os resultados da eficiência diagnóstica associados à simplicidade, praticabilidade e custo referendaram a associação GJ + FR como o mais adequado para o rastreamento. A equivalência das glicemias de 1hPS permitiram a proposição de um novo protocolo de rastreamento e diagnóstico do diabete gestacional, com menores custo e desconforto.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O objetivo deste trabalho foi estratificar 305 idosos com 65 anos ou mais, atendidos em um Centro de Saúde Escola (Botucatu, São Paulo, Brasil), quanto à probabilidade de admissão hospitalar repetida. Os dados foram coletados por meio de um instrumento de avaliação do risco de admissão hospitalar repetida, constituído por oito indicadores de saúde: autopercepção da saúde, hospitalização, consultas médicas, diabetes, doença cardiovascular, sexo, apoio social e idade. Verificou-se que 56,4% dos entrevistados apresentaram baixa probabilidade de admissão hospitalar repetida; 26,9%, média; 10,5%, média-alta; e 6,2%, alta. Na associação dos indicadores de saúde com a probabilidade de admissão hospitalar repetida, observou-se que, para idosos classificados como sendo de riscos médio, médio-alto e alto, em relação àqueles com baixo, os riscos relativos foram significativos: saúde média ou ruim (2,31); hospitalização (2,38); mais de três consultas médicas (1,75); diabetes (2,10); doença cardiovascular (2,76); homens (1,68); e 75 anos ou mais (1,62). Constatou-se que o instrumento utilizado possibilitou a estratificação dos idosos quanto ao risco de serem hospitalizados repetidas vezes, o que pode contribuir para propostas de reorganização dos serviços de saúde.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Os sistemas de telecomunicações emitem radiofreqüência, uma radiação eletromagnética invisível. Telefones celulares transmitem microondas (450900 MHz no sistema analógico e 1,82,2 GHz no sistema digital), muito próximo à orelha do usuário. Esta energia é absorvida pela pele, orelha interna, nervo vestibulococlear e superfície do lobo temporal. OBJETIVO: Revisar a literatura sobre influência dos telefones celulares na audição e equilíbrio. FORMA DE ESTUDO: Revisão sistemática. METODOLOGIA: Foram pesquisados artigos nas bases Lilacs e Medline sobre a influência dos telefones celulares nos sistemas auditivo e vestibular, publicados de 2000 a 2005, e também materiais veiculados na Internet. RESULTADOS: Os estudos sobre radiação do telefone celular e risco de neurinoma do acústico apresentam resultados contraditórios. Alguns autores não encontram maior probabilidade de aparecimento do tumor nos usuários de celulares, enquanto outros relatam que a utilização de telefones analógicos por 10 anos ou mais aumenta o risco para o tumor. A exposição aguda às microondas emitidas pelo celular não influencia a atividade das células ciliadas externas da cóclea, in vivo e in vitro, a condução elétrica no nervo coclear, nem a fisiologia do sistema vestibular em humanos. As próteses auditivas analógicas são mais suscetíveis à interferência eletromagnética dos telefones celulares digitais. CONCLUSÃO: Não há comprovação de lesão cocleovestibular pelos telefones celulares.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O tabagismo está relacionado a 30% das mortes por câncer. É fator de risco para desenvolver carcinomas do aparelho respiratório, esôfago, estômago, pâncreas, cérvix uterina, rim e bexiga. A nicotina induz tolerância e dependência pela ação nas vias dopaminérgicas centrais, levando às sensações de prazer e recompensa mediadas pelo sistema límbico. É estimulante do sistema nervoso central (SNC), aumenta o estado de alerta e reduz o apetite. A diminuição de 50% no consumo da nicotina pode desencadear sintomas de abstinência nos indivíduos dependentes: ansiedade, irritabilidade, distúrbios do sono, aumento do apetite, alterações cognitivas e fissura pelo cigarro. O aconselhamento médico é fundamental para o sucesso no abandono do fumo. A farmacoterapia da dependência de nicotina divide-se em: primeira linha (bupropiona e terapia de reposição da nicotina), e segunda linha (clonidina e nortriptilina). A bupropiona é um antidepressivo não-tricíclico que age inibindo a recaptação de dopamina, cujas contra-indicações são: epilepsia, distúrbios alimentares, hipertensão arterial não-controlada, abstinência recente do álcool e uso de inibidores da monoaminoxidase (MAO). A terapia de reposição de nicotina pode ser feita com adesivos e gomas de mascar. Os efeitos da acupuntura no abandono do fumo ainda não estão completamente esclarecidos. As estratégias de interrupção abrupta ou redução gradual do fumo têm a mesma probabilidade de sucesso.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objetivo: Apresentar as complicações observadas com esferas de diferentes materiais na reconstrução da cavidade anoftálmica. Métodos: Foram avaliados retrospectivamente 117 portadores de cavidade anoftálmica, com tempo mínimo de seguimento de 6 meses, procurando correlacionar sexo, tipo de esfera utilizada, causa da perda do olho, diâmetro da prótese, tipo de cirurgia e a ocorrência das complicações (deiscências e expulsão da esfera). Resultados: As deiscências ocorreram principalmente com esferas de polímero vegetal. A expulsão da esfera ocorreu mais precocemente nos implantes integráveis e foi mais freqüente com as esferas não-integráveis (PMMA). A esfera de polietileno (Polipore) foi a que apresentou menos probabilidade de complicações. Conclusão: A esfera de polietileno é na atualidade a melhor alternativa para preenchimento da cavidade anoftálmica.