930 resultados para Power Flow Control, Radial Distribution System, Distributed Generator (DG)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Esta dissertação tem por propósito analisar os impactos da geração distribuída sobre as correntes de curto-circuito e sobre a proteção das redes de média tensão das concessionárias de distribuição de energia elétrica usando uma abordagem paramétrica. A principal motivação deste trabalho são os recentes incentivos regulatórios que estão fomentando a geração distribuída no Brasil. Contudo, as redes de distribuição convencionais foram projetadas para serem passivas e a introdução da geração poderá causar problemas de ordem técnica que ainda precisam ser resolvidos. Tais problemas foram pesquisados e aqueles relacionados com os impactos sobre as correntes de curto-circuito foram enfatizados. As normas técnicas das concessionárias também foram investigadas porque seus requisitos, como a ligação dos transformadores de acoplamento, influem nas correntes de curto-circuito. Para se calcular as correntes de curto-circuito, desenvolveu-se uma planilha eletrônica cujos resultados foram validados com programas comerciais de análise de redes elétricas. Esta ferramenta foi utilizada para demonstrar, através de exemplos, o impacto causado pela geração distribuída sobre as correntes de curto-circuito e, posteriormente, para realizar as análises paramétricas nas quais a influência de cada variável foi avaliada. A aplicação do método paramétrico permitiu o estudo de possíveis limites para a potência de um gerador distribuído em função dos impactos admissíveis, de seu ponto de conexão, de seus parâmetros elétricos e dos parâmetros elétricos da rede.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The electric vehicle (EV) market has seen a rapid growth in the recent past. With an increase in the number of electric vehicles on road, there is an increase in the number of high capacity battery banks interfacing the grid. The battery bank of an EV, besides being the fuel tank, is also a huge energy storage unit. Presently, it is used only when the vehicle is being driven and remains idle for rest of the time, rendering it underutilized. Whereas on the other hand, there is a need of large energy storage units in the grid to filter out the fluctuations of supply and demand during a day. EVs can help bridge this gap. The EV battery bank can be used to store the excess energy from the grid to vehicle (G2V) or supply stored energy from the vehicle to grid (V2G ), when required. To let power flow happen, in both directions, a bidirectional AC-DC converter is required. This thesis concentrates on the bidirectional AC-DC converters which have a control on power flow in all four quadrants for the application of EV battery interfacing with the grid. This thesis presents a bidirectional interleaved full bridge converter topology. This helps in increasing the power processing and current handling capability of the converter which makes it suitable for the purpose of EVs. Further, the benefit of using the interleaved topology is that it increases the power density of the converter. This ensures optimization of space usage with the same power handling capacity. The proposed interleaved converter consists of two full bridges. The corresponding gate pulses of each switch, in one cell, are phase shifted by 180 degrees from those of the other cell. The proposed converter control is based on the one-cycle controller. To meet the challenge of new requirements of reactive power handling capabilities for grid connected converters, posed by the utilities, the controller is modified to make it suitable to process the reactive power. A fictitious current derived from the grid voltage is introduced in the controller, which controls the converter performance. The current references are generated using the second order generalized integrators (SOGI) and phase locked loop (PLL). A digital implementation of the proposed control ii scheme is developed and implemented using DSP hardware. The simulated and experimental results, based on the converter topology and control technique discussed here, are presented to show the performance of the proposed theory.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Thesis (Master's)--University of Washington, 2016-06

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Thesis (Master's)--University of Washington, 2016-06

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The distributions of eyes-closed resting electroencephalography (EEG) power spectra and their residuals were described and compared using classically averaged and adaptively aligned averaged spectra. Four minutes of eyes-closed resting EEG was available from 69 participants. Spectra were calculated with 0.5-Hz resolution and were analyzed at this level. It was shown that power in the individual 0.5 Hz frequency bins can be considered normally distributed when as few as three or four 2-second epochs of EEG are used in the average. A similar result holds for the residuals. Power at the peak Alpha frequency has quite different statistical behaviour to power at other frequencies and it is considered that power at peak Alpha represents a relatively individuated process that is best measured through aligned averaging. Previous analyses of contrasts in upper and lower alpha bands may be explained in terms of the variability or distribution of the peak Alpha frequency itself.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This is a study of police interviewing using an integrated approach, drawing on CA, CDA and pragmatics. The study focuses on the balance of power and control, finding that in particular the institutional status of the participants, the discursive roles assigned to them by the context, and their relative knowledge, are significant factors affecting the dynamics of the discourse. Four discursive features are identified as particularly significant, and a detailed analysis of the complex interplay of these features shows that power and control are constantly under negotiation, and are always open to challenge and resistance. Further it is shown that discursive dominance is not necessarily advantageous to participants, due to the specific goals and purposes of the police interview context. A wider consideration of the context illustrates the contribution that linguistics can make to the use of police interview data as evidence in the UK criminal justice system.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

It is known that distillation tray efficiency depends on the liquid flow pattern, particularly for large diameter trays. Scale·up failures due to liquid channelling have occurred, and it is known that fitting flow control devices to trays sometirr.es improves tray efficiency. Several theoretical models which explain these observations have been published. Further progress in understanding is at present blocked by lack of experimental measurements of the pattern of liquid concentration over the tray. Flow pattern effects are expected to be significant only on commercial size trays of a large diameter and the lack of data is a result of the costs, risks and difficulty of making these measurements on full scale production columns. This work presents a new experiment which simulates distillation by water cooling. and provides a means of testing commercial size trays in the laboratory. Hot water is fed on to the tray and cooled by air forced through the perforations. The analogy between heat and mass transfer shows that the water temperature at any point is analogous to liquid concentration and the enthalpy of the air is analogous to vapour concentration. The effect of the liquid flow pattern on mass transfer is revealed by the temperature field on the tray. The experiment was implemented and evaluated in a column of 1.2 m. dia. The water temperatures were measured by thennocouples interfaced to an electronic computerised data logging system. The "best surface" through the experimental temperature measurements was obtained by the mathematical technique of B. splines, and presented in tenos of lines of constant temperature. The results revealed that in general liquid channelling is more imponant in the bubbly "mixed" regime than in the spray regime. However, it was observed that severe channelling also occurred for intense spray at incipient flood conditions. This is an unexpected result. A computer program was written to calculate point efficiency as well as tray efficiency, and the results were compared with distillation efficiencies for similar loadings. The theoretical model of Porter and Lockett for predicting distillation was modified to predict water cooling and the theoretical predictions were shown to be similar to the experimental temperature profiles. A comparison of the repeatability of the experiments with an errors analysis revealed that accurate tray efficiency measurements require temperature measurements to better than ± 0.1 °c which is achievable with conventional techniques. This was not achieved in this work, and resulted in considerable scatter in the efficiency results. Nevertheless it is concluded that the new experiment is a valuable tool for investigating the effect of the liquid flow pattern on tray mass transfer.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This thesis describes an experimental and analytic study of the effects of magnetic non-linearity and finite length on the loss and field distribution in solid iron due to a travelling mmf wave. In the first half of the thesis, a two-dimensional solution is developed which accounts for the effects of both magnetic non-linearity and eddy-current reaction; this solution is extended, in the second half, to a three-dimensional model. In the two-dimensional solution, new equations for loss and flux/pole are given; these equations contain the primary excitation, the machine parameters and factors describing the shape of the normal B-H curve. The solution applies to machines of any air-gap length. The conditions for maximum loss are defined, and generalised torque/frequency curves are obtained. A relationship between the peripheral component of magnetic field on the surface of the iron and the primary excitation is given. The effects of magnetic non-linearity and finite length are combined analytically by introducing an equivalent constant permeability into a linear three-dimensional analysis. The equivalent constant permeability is defined from the non-linear solution for the two-dimensional magnetic field at the axial centre of the machine to avoid iterative solutions. In the linear three-dimensional analysis, the primary excitation in the passive end-regions of the machine is set equal to zero and the secondary end faces are developed onto the air-gap surface. The analyses, and the assumptions on which they are based, were verified on an experimental machine which consists of a three-phase rotor and alternative solid iron stators, one with copper end rings, and one without copper end rings j the main dimensions of the two stators are identical. Measurements of torque, flux /pole, surface current density and radial power flow were obtained for both stators over a range of frequencies and excitations. Comparison of the measurements on the two stators enabled the individual effects of finite length and saturation to be identified, and the definition of constant equivalent permeability to be verified. The penetration of the peripheral flux into the stator with copper end rings was measured and compared with theoretical penetration curves. Agreement between measured and theoretical results was generally good.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Studies into gas-liquid flow patterns were carried out on commercial scale sieve trays where the ratio of froth depth to flow path length is typical of that found in practice. Experiments were conducted on a 2.44 m diameter air-water distillation simulator, in which flow patterns were investigated by direct observation, using directional flow pointers; by water cooling, to simulate mass transfer; and by height of clear liquid measurements across the tray. The flow rates used are typical of those found in practice. The approach adopted was to investigate the effect of the gas flow on the liquid flow by comparing water only flow patterns across an unperforated tray with air-water flow patterns on perforated trays. Initial gas-liquid contacting experiments on the 6.35 mm hole tray showed that, under certain conditions, the gas flow pattern beneath the test tray can have a significant effect on the tray liquid flow pattern such that gas-driven liquid circulation was produced. This was found to be a function of this particular air-water simulator design, and as far as is known this is the first time that this phenomenon has been observed. Consequently non-uniform gas flow effects were removed by modification of the gas distribution system. By eliminating gas circulation effects, the effect of the gas flow on the separation of liquid flow was similar to that obtained on the 1.0 mm hole tray (Hine, 1990). That is, flow separation occurred at the ends of the inlet downcomer which produced large circulating zones along the tray segments both on the non-perforated and perforated trays. The air when forced through the liquid, inhibited circulating flow such that it only occurred at high water inlet velocities. With the 6.35 mm hole tray, the growth and velocity of circulating flow was reduced at high superficial air velocities, and in the experiments to simulate distillation, liquid was in forward flow over most of the tray.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Computerised production control developments have concentrated on Manufacturing Resources Planning (MRP II) systems. The literature suggests however, that despite the massive investment in hardware, software and management education, successful implementation of such systems in manufacturing industries has proved difficult. This thesis reviews the development of production planning and control systems, in particular, investigates the causes of failures in implementing MRP/MRP II systems in industrial environments and argues that the centralised and top-down planning structure, as well as the routine operational methodology of such systems, is inherently prone to failure. The thesis reviews the control benefits of cellular manufacturing systems but concludes that in more dynamic manufacturing environments, techniques such as Kanban are inappropriate. The basic shortcomings of MRP II systems are highlighted and a new enhanced operational methodology based on distributed planning and control principles is introduced. Distributed Manufacturing Resources Planning (DMRP), was developed as a capacity sensitive production planning and control solution for cellular manufacturing environments. The system utilises cell based, independently operated MRP II systems, integrated into a plant-wide control system through a Local Area Network. The potential benefits of adopting the system in industrial environments is discussed and the results of computer simulation experiments to compare the performance of the DMRP system against the conventional MRP II systems presented. DMRP methodology is shown to offer significant potential advantages which include ease of implementation, cost effectiveness, capacity sensitivity, shorter manufacturing lead times, lower working in progress levels and improved customer service.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents an effective decision making system for leak detection based on multiple generalized linear models and clustering techniques. The training data for the proposed decision system is obtained by setting up an experimental pipeline fully operational distribution system. The system is also equipped with data logging for three variables; namely, inlet pressure, outlet pressure, and outlet flow. The experimental setup is designed such that multi-operational conditions of the distribution system, including multi pressure and multi flow can be obtained. We then statistically tested and showed that pressure and flow variables can be used as signature of leak under the designed multi-operational conditions. It is then shown that the detection of leakages based on the training and testing of the proposed multi model decision system with pre data clustering, under multi operational conditions produces better recognition rates in comparison to the training based on the single model approach. This decision system is then equipped with the estimation of confidence limits and a method is proposed for using these confidence limits for obtaining more robust leakage recognition results.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The constant necessity for new sources of renewable energy is increasingly promoting the increase of investments in this area. Among other sources, the wind power has been becoming prominent. It is important to promote the search for the improvement of the technologies involved in the topologies of the wind turbines, seeking for alternatives which enhance the gotten performance, despite the irregularity of the wind speed. This study presents a new system for speed control, in this case applied to the wind turbines - the Electromagnetic Frequency Regulator (EFR). One of the most used devices in some topologies is the mechanical gearboxes which, along with a short service life, often represent sources of noise and defects. The EFR does not need these transmission boxes, representing a technological advancement, using for that an adapted induction machine, in which the stator becomes mobile, supportive to the axis of the turbine. In the topology used in this study, the EFR also allows us to leave out the usage of the eletronic converters to establish the coupling between the generator and the electrical grid. It also the reason why it provides the possibility of obtaining the generation in alternating current, with constant voltage and frequency, where there is no electrical grid. Responsable for the mechanical speed control of the generator, the EFR can be useful in other transmission systems in which the mechanical speed control output is the objective. In addition, the EFR operates through the combination of two inputs, a mechanical and other electrical. It multiplies the possibilities of application because it is able to synergistic coupling between different arrays of energy, and, for such reasons, it enables the various sources of energy involved to be uncoupled from the network, being the synchronous generator responsible for the system connection with the electrical grid, simplifying the control strategies on the power injected in it. Experimental and simulation results are presented through this study, about a wind turbine, validating the proposal related to the efficience in the speed control of the system for different wind conditions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A typical electrical power system is characterized by centr alization of power gene- ration. However, with the restructuring of the electric sys tem, this topology is changing with the insertion of generators in parallel with the distri bution system (distributed gene- ration) that provides several benefits to be located near to e nergy consumers. Therefore, the integration of distributed generators, especially fro m renewable sources in the Brazi- lian system has been common every year. However, this new sys tem topology may result in new challenges in the field of the power system control, ope ration, and protection. One of the main problems related to the distributed generati on is the islanding formation, witch can result in safety risk to the people and to the power g rid. Among the several islanding protection techniques, passive techniques have low implementation cost and simplicity, requiring only voltage and current measuremen ts to detect system problems. This paper proposes a protection system based on the wavelet transform with overcur- rent and under/overvoltage functions as well as infomation of fault-induced transients in order to provide a fast detection and identification of fault s in the system. The propo- sed protection scheme was evaluated through simulation and experimental studies, with performance similar to the overcurrent and under/overvolt age conventional methods, but with the additional detection of the exact moment of the fault.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The electric vehicle (EV) market has seen a rapid growth in the recent past. With an increase in the number of electric vehicles on road, there is an increase in the number of high capacity battery banks interfacing the grid. The battery bank of an EV, besides being the fuel tank, is also a huge energy storage unit. Presently, it is used only when the vehicle is being driven and remains idle for rest of the time, rendering it underutilized. Whereas on the other hand, there is a need of large energy storage units in the grid to filter out the fluctuations of supply and demand during a day. EVs can help bridge this gap. The EV battery bank can be used to store the excess energy from the grid to vehicle (G2V) or supply stored energy from the vehicle to grid (V2G ), when required. To let power flow happen, in both directions, a bidirectional AC-DC converter is required. This thesis concentrates on the bidirectional AC-DC converters which have a control on power flow in all four quadrants for the application of EV battery interfacing with the grid. This thesis presents a bidirectional interleaved full bridge converter topology. This helps in increasing the power processing and current handling capability of the converter which makes it suitable for the purpose of EVs. Further, the benefit of using the interleaved topology is that it increases the power density of the converter. This ensures optimization of space usage with the same power handling capacity. The proposed interleaved converter consists of two full bridges. The corresponding gate pulses of each switch, in one cell, are phase shifted by 180 degrees from those of the other cell. The proposed converter control is based on the one-cycle controller. To meet the challenge of new requirements of reactive power handling capabilities for grid connected converters, posed by the utilities, the controller is modified to make it suitable to process the reactive power. A fictitious current derived from the grid voltage is introduced in the controller, which controls the converter performance. The current references are generated using the second order generalized integrators (SOGI) and phase locked loop (PLL). A digital implementation of the proposed control ii scheme is developed and implemented using DSP hardware. The simulated and experimental results, based on the converter topology and control technique discussed here, are presented to show the performance of the proposed theory.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In Germany the upscaling algorithm is currently the standard approach for evaluating the PV power produced in a region. This method involves spatially interpolating the normalized power of a set of reference PV plants to estimate the power production by another set of unknown plants. As little information on the performances of this method could be found in the literature, the first goal of this thesis is to conduct an analysis of the uncertainty associated to this method. It was found that this method can lead to large errors when the set of reference plants has different characteristics or weather conditions than the set of unknown plants and when the set of reference plants is small. Based on these preliminary findings, an alternative method is proposed for calculating the aggregate power production of a set of PV plants. A probabilistic approach has been chosen by which a power production is calculated at each PV plant from corresponding weather data. The probabilistic approach consists of evaluating the power for each frequently occurring value of the parameters and estimating the most probable value by averaging these power values weighted by their frequency of occurrence. Most frequent parameter sets (e.g. module azimuth and tilt angle) and their frequency of occurrence have been assessed on the basis of a statistical analysis of parameters of approx. 35 000 PV plants. It has been found that the plant parameters are statistically dependent on the size and location of the PV plants. Accordingly, separate statistical values have been assessed for 14 classes of nominal capacity and 95 regions in Germany (two-digit zip-code areas). The performances of the upscaling and probabilistic approaches have been compared on the basis of 15 min power measurements from 715 PV plants provided by the German distribution system operator LEW Verteilnetz. It was found that the error of the probabilistic method is smaller than that of the upscaling method when the number of reference plants is sufficiently large (>100 reference plants in the case study considered in this chapter). When the number of reference plants is limited (<50 reference plants for the considered case study), it was found that the proposed approach provides a noticeable gain in accuracy with respect to the upscaling method.