925 resultados para PUMP-NOISE


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE Coronary artery bypass grafting (CABG) using extracorporeal circulation (ECC) is still the gold standard. However, alternative techniques have been developed to avoid ECC and its potential adverse effects. These encompass minimal extracorporeal circulation (MECC) or off-pump coronary artery bypass grafting (OPCAB). However, the prevailing potential benefits when comparing MECC and OPCABG are not yet clearly established. METHODS In this retrospective study we investigated the potential benefits of MECC and OPCABG in 697 patients undergoing CABG. Of these, 555 patients had been operated with MECC and 142 off-pump. The primary endpoint was Troponin T level as an indicator for myocardial damage. RESULTS Study groups were not significantly different in general. However, patients undergoing OPCABG were significantly older (65.01 years ± 9.5 vs. 69.39 years ± 9.5; p value <0.001) with a higher Logistic EuroSCORE I (4.92% ± 6.5 vs. 5.88% ± 6.8; p value = 0.017). Operating off pump significantly reduced the need for intra-operative blood products (0.7% vs. 8.6%; p-value <0.001) and the length of stay in the intensive care unit (ICU) (2.04 days ± 2.63 vs. 2.76 days ± 2.79; p value <0.001). Regarding other blood values a significant difference could not be found in the adjusted calculations. The combined secondary endpoint, major cardiac or cerebrovascular events (MACCE), was equal in both groups as well. CONCLUSIONS Coronary artery bypass grafting using MECC or OPCABG are two comparable techniques with advantages for OPCABG regarding the reduced need for intra-operative blood products and shorter length of stay in the ICU. However serological values and combined endpoint MACCE did not differ significantly in both groups.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND To date, the use of proton pump inhibitors (PPIs) has been associated with a low risk of hypomagnesaemia and associated adverse outcomes. We hypothesised that a better risk estimate could be derived from a large cohort of outpatients admitted to a tertiary emergency department (ED). METHODS A cross-sectional study was performed in 5118 patients who had measurements of serum magnesium taken on admission to a large tertiary care ED between January 2009 and December 2010. Hypomagnesaemia was defined as a serum magnesium concentration < 0.75 mmol/l. Demographical data, serum electrolyte values, data on medication, comorbidities and outcome with regard to length of hospital stay and mortality were analysed. RESULTS Serum magnesium was normally distributed where upon 1246 patients (24%) were hypomagnesaemic. These patients had a higher prevalence of out-of-hospital PPI use and diuretic use when compared with patients with magnesium levels > 0.75 mmol/l (both p < 0.0001). In multivariable regression analyses adjusted for PPIs, diuretics, renal function and the Charlson comorbidity index score, the association between use of PPIs and risk for hypomagnesaemia remained significant (OR = 2.1; 95% CI: 1.54-2.85). While mortality was not directly related to low magnesium levels (p = 0.67), the length of hospitalisation was prolonged in these patients even after adjustment for underlying comorbid conditions (p < 0.0001). CONCLUSION Use of PPIs predisposes patients to hypomagnesaemia and such to prolonged hospitalisation irrespective of the underlying morbidity, posing a critical concern.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Some patients with a phenotypic appearance of eosinophilic oesophagitis (EoE) respond histologically to PPI, and are described as having PPI-responsive oesophageal eosinophilia (PPI-REE). It is unclear if PPI-REE is a GERD-related phenomenon, a subtype of EoE, or a completely unique entity. AIM To compare demographic, clinical and histological features of EoE and PPI-REE. METHODS Two databases were reviewed from the Walter Reed and Swiss EoE databases. Patients were stratified into two groups, EoE and PPI-REE, based on recent EoE consensus guidelines. Response to PPI was defined as achieving less than 15 eos/hpf and a 50% decrease from baseline following at least a 6-week course of treatment. RESULTS One hundred and three patients were identified (63 EoE and 40 PPI-REE; mean age 40.2 years, 75% male and 89% Caucasian). The two cohorts had similar dysphagia (97% vs. 100%, P = 0.520), food impaction (43% vs. 35%, P = 0.536), and heartburn (33% vs. 32%, P = 1.000) and a similar duration of symptoms (6.0 years vs. 5.8 years, P = 0.850). Endoscopic features were also similar between EoE and PPI-REE; rings (68% vs. 68%, P = 1.000), furrows (70% vs. 70%, P = 1.000), plaques (19% vs. 10%, P = 0.272), strictures (49% vs. 30%, P = 0.066). EoE and PPI-REE were similar in the number of proximal (39 eos/hpf vs. 38 eos/hpf, P = 0.919) and distal eosinophils (50 vs. 43 eos/hpf, P = 0.285). CONCLUSIONS EoE and PPI-responsive oesophageal eosinophilia are similar in clinical, histological and endoscopic features and therefore are indistinguishable without a PPI trial. Further studies are needed to determine why a subset of patients with oesophageal eosinophilia respond to PPI.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The ba3-type cytochrome c oxidase from Thermus thermophilus is a membrane-bound protein complex that couples electron transfer to O2 to proton translocation across the membrane. To elucidate the mechanism of the redox-driven proton pumping, we investigated the kinetics of electron and proton transfer in a structural variant of the ba3 oxidase where a putative "pump site" was modified by replacement of Asp372 by Ile. In this structural variant, proton pumping was uncoupled from internal electron transfer and O2 reduction. The results from our studies show that proton uptake to the pump site (time constant ∼65 μs in the wild-type cytochrome c oxidase) was impaired in the Asp372Ile variant. Furthermore, a reaction step that in the wild-type cytochrome c oxidase is linked to simultaneous proton uptake and release with a time constant of ∼1.2 ms was slowed to ∼8.4 ms, and in Asp372Ile was only associated with proton uptake to the catalytic site. These data identify reaction steps that are associated with protonation and deprotonation of the pump site, and point to the area around Asp372 as the location of this site in the ba3 cytochrome c oxidase.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE The aim of the present study was to evaluate a dose reduction in contrast-enhanced chest computed tomography (CT) by comparing the three latest generations of Siemens CT scanners used in clinical practice. We analyzed the amount of radiation used with filtered back projection (FBP) and an iterative reconstruction (IR) algorithm to yield the same image quality. Furthermore, the influence on the radiation dose of the most recent integrated circuit detector (ICD; Stellar detector, Siemens Healthcare, Erlangen, Germany) was investigated. MATERIALS AND METHODS 136 Patients were included. Scan parameters were set to a thorax routine: SOMATOM Sensation 64 (FBP), SOMATOM Definition Flash (IR), and SOMATOM Definition Edge (ICD and IR). Tube current was set constantly to the reference level of 100 mA automated tube current modulation using reference milliamperes. Care kV was used on the Flash and Edge scanner, while tube potential was individually selected between 100 and 140 kVp by the medical technologists at the SOMATOM Sensation. Quality assessment was performed on soft-tissue kernel reconstruction. Dose was represented by the dose length product. RESULTS Dose-length product (DLP) with FBP for the average chest CT was 308 mGy*cm ± 99.6. In contrast, the DLP for the chest CT with IR algorithm was 196.8 mGy*cm ± 68.8 (P = 0.0001). Further decline in dose can be noted with IR and the ICD: DLP: 166.4 mGy*cm ± 54.5 (P = 0.033). The dose reduction compared to FBP was 36.1% with IR and 45.6% with IR/ICD. Signal-to-noise ratio (SNR) was favorable in the aorta, bone, and soft tissue for IR/ICD in combination compared to FBP (the P values ranged from 0.003 to 0.048). Overall contrast-to-noise ratio (CNR) improved with declining DLP. CONCLUSION The most recent technical developments, namely IR in combination with integrated circuit detectors, can significantly lower radiation dose in chest CT examinations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Strengthening car drivers’ intention to prevent road-traffic noise is a first step toward noise abatement through voluntary change of behavior. We analyzed predictors of this intention based on the norm activation model (i.e., personal norm, problem awareness, awareness of consequences, social norm, and value orientations). Moreover, we studied the effects of noise exposure, noise sensitivity, and noise annoyance on problem awareness. Data came from 1,002 car drivers who participated in a two-wave longitudinal survey over 4 months. Personal norm had a large prospective effect on intention, even when the previous level of intention was controlled for, and mediated the effect of all other variables on intention. Almost 60% of variance in personal norm was explained by problem awareness, social norm, and biospheric value orientation. The effects of noise sensitivity and noise exposure on problem awareness were small and mediated by noise annoyance. We propose four communication strategies for strengthening the intention to prevent road-traffic noise in car drivers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND & AIMS: Esophageal impedance measurements have been proposed to indicate the status of the esophageal mucosa, and might be used to study the roles of the impaired mucosal integrity and increased acid sensitivity in patients with heartburn. We compared baseline impedance levels among patients with heartburn who did and did not respond to proton pump inhibitor (PPI) therapy, along with the pathophysiological characteristics of functional heartburn (FH). METHODS: In a case-control study, we collected data from January to December 203 on patients with heartburn and normal findings from endoscopy who were not receiving PPI therapy and underwent impedance pH testing at hospitals in Italy. Patients with negative test results were placed on an 8-week course of PPI therapy (84 patients received esomeprazole and 36 patients received pantoprazole). Patients with more than 50% symptom improvement were classified as FH/PPI responders and patients with less than 50% symptom improvement were classified as FH/PPI nonresponders. Patients with hypersensitive esophagus and healthy volunteers served as controls. In all patients and controls, we measured acid exposure time, number of refluxes, baseline impedance, and swallow-induced peristaltic wave indices. RESULTS: FH/PPI responders had higher acid exposure times, numbers of reflux events, and acid refluxes compared with FH/PPI nonresponders (P < .05). Patients with hypersensitive esophagus had mean acid exposure times and numbers of reflux events similar to those of FH/PPI responders. Baseline impedance levels were lower in FH/PPI responders and patients with hypersensitive esophagus, compared with FH/PPI nonresponders and healthy volunteers (P < .001). Swallow-induced peristaltic wave indices were similar between FH/PPI responders and patients with hypersensitive esophagus. CONCLUSIONS: Patients with FH who respond to PPI therapy have impedance pH features similar to those of patients with hypersensitive esophagus. Baseline impedance measurements might allow for identification of patients who respond to PPIs but would be classified as having FH based on conventional impedance-pH measurements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present an application and sample independent method for the automatic discrimination of noise and signal in optical coherence tomography Bscans. The proposed algorithm models the observed noise probabilistically and allows for a dynamic determination of image noise parameters and the choice of appropriate image rendering parameters. This overcomes the observer variability and the need for a priori information about the content of sample images, both of which are challenging to estimate systematically with current systems. As such, our approach has the advantage of automatically determining crucial parameters for evaluating rendered image quality in a systematic and task independent way. We tested our algorithm on data from four different biological and nonbiological samples (index finger, lemon slices, sticky tape, and detector cards) acquired with three different experimental spectral domain optical coherence tomography (OCT) measurement systems including a swept source OCT. The results are compared to parameters determined manually by four experienced OCT users. Overall, our algorithm works reliably regardless of which system and sample are used and estimates noise parameters in all cases within the confidence interval of those found by observers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We consider the problem of twenty questions with noisy answers, in which we seek to find a target by repeatedly choosing a set, asking an oracle whether the target lies in this set, and obtaining an answer corrupted by noise. Starting with a prior distribution on the target's location, we seek to minimize the expected entropy of the posterior distribution. We formulate this problem as a dynamic program and show that any policy optimizing the one-step expected reduction in entropy is also optimal over the full horizon. Two such Bayes optimal policies are presented: one generalizes the probabilistic bisection policy due to Horstein and the other asks a deterministic set of questions. We study the structural properties of the latter, and illustrate its use in a computer vision application.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION The Rondo is a single-unit cochlear implant (CI) audio processor comprising the identical components as its behind-the-ear predecessor, the Opus 2. An interchange of the Opus 2 with the Rondo leads to a shift of the microphone position toward the back of the head. This study aimed to investigate the influence of the Rondo wearing position on speech intelligibility in noise. METHODS Speech intelligibility in noise was measured in 4 spatial configurations with 12 experienced CI users using the German adaptive Oldenburg sentence test. A physical model and a numerical model were used to enable a comparison of the observations. RESULTS No statistically significant differences of the speech intelligibility were found in the situations in which the signal came from the front and the noise came from the frontal, ipsilateral, or contralateral side. The signal-to-noise ratio (SNR) was significantly better with the Opus 2 in the case with the noise presented from the back (4.4 dB, p < 0.001). The differences in the SNR were significantly worse with the Rondo processors placed further behind the ear than closer to the ear. CONCLUSION The study indicates that CI users with the receiver/stimulator implanted in positions further behind the ear are expected to have higher difficulties in noisy situations when wearing the single-unit audio processor.