920 resultados para Optic disc parameters


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Parkinson disease (PD) is associated with a clinical course of variable duration, severity, and a combination of motor and non-motor features. Recent PD research has focused primarily on etiology rather than clinical progression and long-term outcomes. For the PD patient, caregivers, and clinicians, information on expected clinical progression and long-term outcomes is of great importance. Today, it remains largely unknown what factors influence long-term clinical progression and outcomes in PD; recent data indicate that the factors that increase the risk to develop PD differ, at least partly, from those that accelerate clinical progression and lead to worse outcomes. Prospective studies will be required to identify factors that influence progression and outcome. We suggest that data for such studies is collected during routine office visits in order to guarantee high external validity of such research. We report here the results of a consensus meeting of international movement disorder experts from the Genetic Epidemiology of Parkinson's Disease (GEO-PD) consortium, who convened to define which long-term outcomes are of interest to patients, caregivers and clinicians, and what is presently known about environmental or genetic factors influencing clinical progression or long-term outcomes in PD. We propose a panel of rating scales that collects a significant amount of phenotypic information, can be performed in the routine office visit and allows international standardization. Research into the progression and long-term outcomes of PD aims at providing individual prognostic information early, adapting treatment choices, and taking specific measures to provide care optimized to the individual patient's needs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper discusses the levels of degradation of some co- and byproducts of the food chain intended for feed uses. As the first part of a research project, 'Feeding Fats Safety', financed by the sixth Framework Programme-EC, a total of 123 samples were collected from 10 European countries, corresponding to fat co- and byproducts such as animal fats, fish oils, acid oils from refining, recycled cooking oils, and other. Several composition and degradation parameters (moisture, acid value, diacylglycerols and monoacylglycerols, peroxides, secondary oxidation products, polymers of triacylglycerols, fatty acid composition, tocopherols, and tocotrienols) were evaluated. These findings led to the conclusion that some fat by- and coproducts, such as fish oils, lecithins, and acid oils, show poor, nonstandardized quality and that production processes need to be greatly improved. Conclusions are also put forward about the applicability and utility of each analytical parameter for characterization and quality control.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To meta-analyze the literature on the clinical performance of Class V restorations to assess the factors that influence retention, marginal integrity, and marginal discoloration of cervical lesions restored with composite resins, glass-ionomer-cement-based materials [glass-ionomer cement (GIC) and resin-modified glass ionomers (RMGICs)], and polyacid-modified resin composites (PMRC). MATERIALS AND METHODS: The English literature was searched (MEDLINE and SCOPUS) for prospective clinical trials on cervical restorations with an observation period of at least 18 months. The studies had to report about retention, marginal discoloration, marginal integrity, and marginal caries and include a description of the operative technique (beveling of enamel, roughening of dentin, type of isolation). Eighty-one studies involving 185 experiments for 47 adhesives matched the inclusion criteria. The statistical analysis was carried out by using the following linear mixed model: log (-log (Y /100)) = β + α log(T ) + error with β = log(λ), where β is a summary measure of the non-linear deterioration occurring in each experiment, including a random study effect. RESULTS: On average, 12.3% of the cervical restorations were lost, 27.9% exhibited marginal discoloration, and 34.6% exhibited deterioration of marginal integrity after 5 years. The calculation of the clinical index was 17.4% of failures after 5 years and 32.3% after 8 years. A higher variability was found for retention loss and marginal discoloration. Hardly any secondary caries lesions were detected, even in the experiments with a follow-up time longer than 8 years. Restorations placed using rubber-dam in teeth whose dentin was roughened showed a statistically significantly higher retention rate than those placed in teeth with unprepared dentin or without rubber-dam (p < 0.05). However, enamel beveling had no influence on any of the examined variables. Significant differences were found between pairs of adhesive systems and also between pairs of classes of adhesive systems. One-step self-etching had a significantly worse clinically index than two-step self-etching and three-step etch-and-rinse (p = 0.026 and p = 0.002, respectively). CONCLUSION: The clinical performance is significantly influenced by the type of adhesive system and/or the adhesive class to which the system belongs. Whether the dentin/enamel is roughened or not and whether rubberdam isolation is used or not also significantly influenced the clinical performance. Composite resin restorations placed with two-step self-etching and three-step etch-and-rinse adhesive systems should be preferred over onestep self-etching adhesive systems, GIC-based materials, and PMRCs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: We aimed to study the relationship between two morphological parameters recently described on MRI images in relation to lumbar spinal stenosis (LSS): the first is the sedimentation sign (SedS) and the second is the morphological grading of lumbar stenosis. MATERIALS AND METHODS: MRIs from a total of 137 patients were studied. From those, 110 were issued from a prospective database of symptomatic LSS patients, of whom 73 were treated surgically and 37 conservatively based on symptom severity. A third group consisting of 27 subjects complaining of low back pain (LBP) served as control. Severity of stenosis was judged at disc level using the four A to D grade morphological classification. The presence of a SedS was judged at pedicle level, above or below the site of maximal stenosis. RESULTS: A positive SedS was observed in 58, 69 and 76 % of patients demonstrating B, C and D morphology, respectively, but in none with grade A morphology. The SedS was positive in 67 and 35 % of the surgically and conservatively treated patients, respectively, and in 8 % of the LBP group. C and D morphological grades were present in 97 and 35 % of patients in the surgically and conservatively treated group, respectively, and in 18 % of the LBP group. Presence of a positive SedS carried an increased risk of being submitted to surgery in the symptomatic LSS group (OR 3.5). This risk was even higher in the LSS patients demonstrating grade C or D morphology (OR 65). DISCUSSION AND CONCLUSION: One-third of surgically treated LSS patients do not present a SedS. This sign appears to be a lesser predictor of treatment modality in our setting of symptomatic LSS patients compared to the severity of stenosis judged by the morphological grade.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Clogging, measured through head loss across filters, and the filtration quality of different filters using different effluents were studied. The filters used were: 115, 130, and 200 m disc filters; 98, 115, 130, and 178 m screen filters; and a sand filter filled with a single layer of sand with an effective diameter of 0.65 mm. The filters were used with a meat industry effluent and secondary and tertiary effluents of two wastewater treatment plants. It was observed that clogging depended on the type of effluent. With the meat industry effluent, the poorest quality effluent, disc filters clogged more than the other filter types. When the wastewater treatment plant effluents were used, the disc filters showed less frequent clogging. Several physical and chemical parameters, such as total suspended solids, chemical oxygen demand, turbidity, electrical conductivity, pH, and number of particles, were analyzed in the effluents at the entry and exit points of the filters. In general, filters did not reduce the values of the main clogging parameters to a great degree. It was found that the parameter that explained the clogging, expressed as Boucher’s filterability index, was different depending on the type of effluent and filter. The best quality of filtration was achieved with a sand filter when the meat industry effluent was used. No significant differences were observed between the quality of filtration of disc and screen filters when operating with the secondary and tertiary effluents

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present work is a part of the large project with purpose to qualify the Flash memory for automotive application using a standardized test and measurement flow. High memory reliability and data retention are the most critical parameters in this application. The current work covers the functional tests and data retention test. The purpose of the data retention test is to obtain the data retention parameters of the designed memory, i.e. the maximum time of information storage at specified conditions without critical charge leakage. For this purpose the charge leakage from the cells, which results in decrease of cells threshold voltage, was measured after a long-time hightemperature treatment at several temperatures. The amount of lost charge for each temperature was used to calculate the Arrhenius constant and activation energy for the discharge process. With this data, the discharge of the cells at different temperatures during long time can be predicted and the probability of data loss after years can be calculated. The memory chips, investigated in this work, were 0.035 μm CMOS Flash memory testchips, designed for further use in the Systems-on-Chips for automotive electronics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Drosophila Decapentaplegic (Dpp) has served as a paradigm to study morphogen-dependent growth control. However, the role of a Dpp gradient in tissue growth remains highly controversial. Two fundamentally different models have been proposed: the 'temporal rule' model suggests that all cells of the wing imaginal disc divide upon a 50% increase in Dpp signalling, whereas the 'growth equalization model' suggests that Dpp is only essential for proliferation control of the central cells. Here, to discriminate between these two models, we generated and used morphotrap, a membrane-tethered anti-green fluorescent protein (GFP) nanobody, which enables immobilization of enhanced (e)GFP::Dpp on the cell surface, thereby abolishing Dpp gradient formation. We find that in the absence of Dpp spreading, wing disc patterning is lost; however, lateral cells still divide at normal rates. These data are consistent with the growth equalization model, but do not fit a global temporal rule model in the wing imaginal disc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study examined the effect of optic nerve disease, hence retinal ganglion cell loss, on non-visual functions related to melanopsin signalling. Test subjects were patients with bilateral visual loss and optic atrophy from either hereditary optic neuropathy (n = 11) or glaucoma (n = 11). We measured melatonin suppression, subjective sleepiness and cognitive functions in response to bright light exposure in the evening. We also quantified the post-illumination pupil response to a blue light stimulus. All results were compared to age-matched controls (n = 22). Both groups of patients showed similar melatonin suppression when compared to their controls. Greater melatonin suppression was intra-individually correlated to larger post-illumination pupil response in patients and controls. Only the glaucoma patients demonstrated a relative attenuation of their pupil response. In addition, they were sleepier with slower reaction times during nocturnal light exposure. In conclusion, glaucomatous, but not hereditary, optic neuropathy is associated with reduced acute light effects. At mild to moderate stages of disease, this is detected only in the pupil function and not in responses conveyed via the retinohypothalamic tract such as melatonin suppression.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rapid manufacturing is an advanced manufacturing technology based on layer-by-layer manufacturing to produce a part. This paper presents experimental work carried out to investigate the effects of scan speed, layer thickness, and building direction on the following part features: dimensional error, surface roughness, and mechanical properties for DMLS with DS H20 powder and SLM with CL 20 powder (1.4404/AISI 316L). Findings were evaluated using ANOVA analysis. According to the experimental results, build direction has a significant effect on part quality, in terms of dimensional error and surface roughness. For the SLM process, the build direction has no influence on mechanical properties. Results of this research support industry estimating part quality and mechanical properties before the production of parts with additive manufacturing, using iron-based powders

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Reference intervals for many laboratory parameters determined in 24-h urine collections are either not publicly available or based on small numbers, not sex specific or not from a representative sample. METHODS: Osmolality and concentrations or enzymatic activities of sodium, potassium, chloride, glucose, creatinine, citrate, cortisol, pancreatic α-amylase, total protein, albumin, transferrin, immunoglobulin G, α1-microglobulin, α2-macroglobulin, as well as porphyrins and their precursors (δ-aminolevulinic acid and porphobilinogen) were determined in 241 24-h urine samples of a population-based cohort of asymptomatic adults (121 men and 120 women). For 16 of these 24 parameters creatinine-normalized ratios were calculated based on 24-h urine creatinine. The reference intervals for these parameters were calculated according to the CLSI C28-A3 statistical guidelines. RESULTS: By contrast to most published reference intervals, which do not stratify for sex, reference intervals of 12 of 24 laboratory parameters in 24-h urine collections and of eight of 16 parameters as creatinine-normalized ratios differed significantly between men and women. For six parameters calculated as 24-h urine excretion and four parameters calculated as creatinine-normalized ratios no reference intervals had been published before. For some parameters we found significant and relevant deviations from previously reported reference intervals, most notably for 24-h urine cortisol in women. Ten 24-h urine parameters showed weak or moderate sex-specific correlations with age. CONCLUSIONS: By applying up-to-date analytical methods and clinical chemistry analyzers to 24-h urine collections from a large population-based cohort we provide as yet the most comprehensive set of sex-specific reference intervals calculated according to CLSI guidelines for parameters determined in 24-h urine collections.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Disc herniation with posterior epidural migration is a rare and often symptomatic entity. Multiple are the natural barriers that prevent this pattern of migration. Enhanced magnetic resonance imaging is the diagnostic modality of choice in these cases. The diagnostic dilemma in this case was the contraindication to the use of contrast since the patient was known to have chronic renal failure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To demonstrate five discal cysts with detailed magnetic resonance imaging findings in nonsurgical and following postoperative microdiscectomy. MATERIALS AND METHODS: Five discal cysts in four patients who underwent magnetic resonance imaging were found through a search in our database and referral from a single orthopedic spine surgeon. Computed tomography in two cases and computed tomography discography in one case were also performed. RESULTS: Five discal cysts were present in four patients. Three patients had no history of previous lumbar surgery and the other patient presented with two discal cysts and recurrent symptoms after partial laminectomy and microdiscectomy. All were oval shaped and seated in the anterior epidural space. Four were ventrolateral, and the other one was centrally positioned in the anterior spinal canal. One showed continuity with the central disc following discography. Three were surgically removed. CONCLUSION: Magnetic resonance imaging can easily depict an epidural cyst and the diagnosis of a discal cyst should be raised when an homogeneous ventrolateral epidural cyst contiguous to a mild degenerated disc is identified.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective To develop procedures to ensure consistency of printing quality of digital images, by means of hardcopy quantitative analysis based on a standard image. Materials and Methods Characteristics of mammography DI-ML and general purpose DI-HL films were studied through the QC-Test utilizing different processing techniques in a FujiFilm®-DryPix4000 printer. A software was developed for sensitometric evaluation, generating a digital image including a gray scale and a bar pattern to evaluate contrast and spatial resolution. Results Mammography films showed maximum optical density of 4.11 and general purpose films, 3.22. The digital image was developed with a 33-step wedge scale and a high-contrast bar pattern (1 to 30 lp/cm) for spatial resolution evaluation. Conclusion Mammographic films presented higher values for maximum optical density and contrast resolution as compared with general purpose films. The utilized digital processing technique could only change the image pixels matrix values and did not affect the printing standard. The proposed digital image standard allows greater control of the relationship between pixels values and optical density obtained in the analysis of films quality and printing systems.