943 resultados para Obesity. Cardiopulmonary exercise test. uptake oxygen. incremental test
Resumo:
Objective: It was the aim of this study to evaluate whether chronic pain in athletes is related to performance, measured by the maximum oxygen consumption and production of hormones and cytokines. Methods: Fifty-five athletes with a mean age of 31.9 +/- 4.2 years engaged in regular competition and showing no symptoms of acute inflammation, particularly fever, were studied. They were divided into 2 subgroups according to the occurrence of pain. Plasma concentrations of adrenaline, noradrenaline, cortisol, prolactin, growth hormone and dopamine were measured by radioimmunoassay, and the production of the cytokines interleukin (IL)-1, IL-2, IL-4, IL-6, tumor necrosis factor-alpha, interferon-alpha and prostaglandin E-2 by whole-blood culture. Maximal oxygen consumption was determined during an incremental treadmill test. Results: There was no change in the concentration of stress hormones, but the athletes with chronic pain showed a reduction in maximum oxygen consumption (22%) and total consumption at the anaerobic threshold (25%), as well as increased cytokine production. Increases of 2.7-, 8.1-, 1.7- and 3.7-fold were observed for IL-1, IL-2, tumor necrosis factor-alpha and interferon-alpha, respectively. Conclusions: Our data show that athletes with chronic pain have enhanced production of proinflammatory cytokines and lipid mediators and reduced performance in the ergospirometric test. Copyright (c) 2008 S. Karger AG, Basel.
Resumo:
The aim of this study was 1) to validate the 0.5 body-mass exponent for maximal oxygen uptake (V. O2max) as the optimal predictor of performance in a 15 km classical-technique skiing competition among elite male cross-country skiers and 2) to evaluate the influence of distance covered on the body-mass exponent for V. O2max among elite male skiers. Twenty-four elite male skiers (age: 21.4±3.3 years [mean ± standard deviation]) completed an incremental treadmill roller-skiing test to determine their V. O2max. Performance data were collected from a 15 km classicaltechnique cross-country skiing competition performed on a 5 km course. Power-function modeling (ie, an allometric scaling approach) was used to establish the optimal body-mass exponent for V . O2max to predict the skiing performance. The optimal power-function models were found to be race speed = 8.83⋅(V . O2max m-0.53) 0.66 and lap speed = 5.89⋅(V . O2max m-(0.49+0.018lap)) 0.43e0.010age, which explained 69% and 81% of the variance in skiing speed, respectively. All the variables contributed to the models. Based on the validation results, it may be recommended that V. O2max divided by the square root of body mass (mL⋅min−1 ⋅kg−0.5) should be used when elite male skiers’ performance capability in 15 km classical-technique races is evaluated. Moreover, the body-mass exponent for V . O2max was demonstrated to be influenced by the distance covered, indicating that heavier skiers have a more pronounced positive pacing profile (ie, race speed gradually decreasing throughout the race) compared to that of lighter skiers.
Resumo:
The relation between metabolic demand and maximal oxygen consumption during exercise have been investigated in different areas of knowledge. In the health field, the determination of maximal oxygen consumption (VO2max) is considered a method to classify the level of physical fitness or the risk of cardiocirculatory diseases. The accuracy to obtain data provides a better evaluation of functional responses and allows a reduction in the error margin at the moment of risk classification, as well as, at the moment of determination of aerobic exercise work load. In Brasil, the use of respirometry associated to ergometric test became an opition in the cardiorespiratory evaluation. This equipment allows predictions concerning the oxyredutase process, making it possible to identify physiological responses to physical effort as the respiratory threshold. This thesis focused in the development of mathematical models developed by multiple regression validated by the stepwise method, aiming to predict the VO2max based on respiratory responses to physical effort. The sample was composed of a ramdom sample of 181 healthy individuals, men and women, that were randomized to two groups: regression group and cross validation group (GV). The voluntiars were submitted to a incremental treadmill test; objetiving to determinate of the second respiratory threshold (LVII) and the Peak VO2max. Using the método forward addition method 11 models of VO2max prediction in trendmill were developded. No significative differences were found between the VO2max meansured and the predicted by models when they were compared using ANOVA One-Way and the Post Hoc test of Turkey. We concluded that the developed mathematical models allow a prediction of the VO2max of healthy young individuals based on the LVII
Resumo:
The cardiopulmonary effects of desflurane and sevoflurane anesthesia were compared in cats breathing spontaneously. Heart (HR) and respiratory (RR) rates; systolic (SAP), diastolic (DAP) and mean arterial (MAP) pressures; partial pressure of end tidal carbon dioxide (PETCO(2)), arterial blood pH (pH), arterial partial pressure of oxygen (PaO(2)) and carbon dioxide (PaCO(2)); base deficit (BD), arterial oxygen saturation (SaO(2)) and bicarbonate ion concentration (HCO(3)) were measured. Anesthesia was induced with propofol (8 +/- 2.3 mg/kg IV) and maintained with desflurane (GD) or sevoflurane (GS), both at 1.3 MAC. Data were analyzed by analysis of variance (ANOVA), followed by the Tukey test (P < 0.05). Both anesthetics showed similar effects. HR and RR decreased when compared to the basal values, but remained constant during inhalant anesthesia and PETCO(2) increased with time. Both anesthetics caused acidemia and hypercapnia, but BD stayed within normal limits. Therefore, despite reducing HR and SAP (GD) when compared to the basal values, desflurane and sevoflurane provide good stability of the cardiovascular parameters during a short period of inhalant anesthesia (T20-T60). However, both volatile anesthetics cause acute respiratory acidosis in cats breathing spontaneously. (c) 2004 ESFM and AAFP. Published by Elsevier Ltd. All rights reserved.
Resumo:
INTRODUÇÃO: a necessidade de reposição ao máximo das perdas hídricas tornou-se estabelecida e difundida nos consensos internacionais. Entretanto, permanece pouco compreendida a influência da reposição quando administrada, igualmente, durante e após o exercício sobre parâmetros cardiorrespiratórios. OBJETIVO: analisar os efeitos da reposição hidroeletrolítica na frequência cardíaca (FC), pressão arterial sistólica (PAS), pressão arterial diastólica (PAD), saturação parcial de oxigênio (SpO2) e frequência respiratória (f) de jovens durante e após um exercício de longa duração. MÉTODOS: 31 jovens (21,55 ± 1,89 anos) realizaram três visitas ao laboratório (intervalo de 48 horas entre elas), sendo na primeira aplicado um teste incremental, para determinação da carga utilizada nas visitas seguintes, e nas duas últimas, denominadas protocolo controle (PC) e protocolo experimental (PE), os sujeitos foram submetidos a 10 min de repouso supino, 90 min de exercício em esteira ergométrica (60% do VO2pico) e 60 min de repouso supino. No PC não houve hidratação e no PE houve ingestão de solução isotônica. Os parâmetros FC, PAS, PAD, SpO2 e f foram mensurados no final do repouso; nos minutos 30, 60 e 90 do exercício, com exceção da f; e nos minutos 1, 3, 5, 7, 10, 20, 30, 40, 50 e 60 pós-exercício. Foi aplicado o teste t de Student ou teste de Mann-Whitney e ANOVA para medidas repetidas ou teste de Friedman seguidos de testes post hoc, com p < 0,05. RESULTADOS: a solução hidroeletrolítica proporcionou manutenção da PAS e da PAD, e menor incremento da FC durante o exercício; e promoveu retorno mais rápido da FC e conservou PAD, SpO2, PAS (a partir do 5º min) e f (a partir do 30º min) no período de recuperação. CONCLUSÃO: o protocolo de hidratação influenciou parâmetros cardiorrespiratórios de jovens durante e após a realização de atividade física submáxima de intensidade constante e longa duração.
Resumo:
O presente estudo comparou valores de glicemia, frequência cardíaca em repouso e durante exercício, além da composição corporal entre hipertensos e normotensos. A amostra foi composta por 32 jovens do sexo masculino, com média de idade de 22,6 anos. Inicialmente, aferiu-se a pressão arterial, para divisão em dois grupos: hipertensos e normotensos. Posteriormente foram mensurados, glicemia em jejum, impedância bioelétrica, antropometria, e a frequência cardíaca no repouso, durante o teste de esforço máximo e na fase de recuperação. A análise estatística foi composta pelo teste t- Student e análise de variância para medidas repetidas two-way, entre os grupos. O valor de significância adotado foi p = 0,05. Os dados analisados mostraram que indivíduos hipertensos apresentam maiores índices metabólicos e valores hemodinâmicos do que indivíduos normotensos, sendo estes indicadores de risco cardiovascular.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Backgroud: Obesity is a major public health problem and is related to the low physical capacity when obese are compared to no-obese people, however the cause of this limitation is not completely understood. The measurement associated of physiological response to the telemetric 6MWT adds information of metabolic and respiratory system for diagnose of the functional limitation. Objective: Analyze physiological, metabolic and ventilatory responses in women with different body fat during the 6MWT. Methods: 32 women (8 non-obese, 8 Overweight, 8 Obese and 8 morbidly obese) were evaluated for anthropometry, lung function and exercise capacity. Results: Morbidly obese walked the shortest distance (400.2±38.7m), had lower VO2/Kg (12.75±3.20l/Kg/min) and lower R (0.74± 0.11) in the 6MWT compared to other groups. Analyses of metabolic (VO2 and VCO2) and respiratory (VE, VT and BF) during the test did not identify differences between groups. The evaluation of cardiac function (O2 pulse) found higher values in the OM (12.3 ± 4.9ml/bat). Conclusion: The OM had worse performance in the 6MWT compared to other groups. The physical performance may be reduced in this population related to a protocol-dependent response because the speed of 6MWT is self-adjusted allows the individual himself select the intensity of the test, making it set at a speed where there is energy saving
Resumo:
We assessed the 6-min walk distance (6MWD) and body weight x distance product (6MWw) in healthy Brazilian subjects and compared measured 6MWD with values predicted in five reference equations developed for other populations. Anthropometry, spirometry, reported physical activity, and two walk tests in a 30-m corridor were evaluated in 134 subjects (73 females, 13-84 years). Mean 6MWD and 6MWw were significantly greater in males than in females (622 ± 80 m, 46,322 ± 10,539 kg.m vs 551 ± 71 m, 36,356 ± 8,289 kg.m, P < 0.05). Four equations significantly overestimated measured 6MWD (range, 32 ± 71 to 137 ± 74 m; P < 0.001), and one significantly underestimated it (-36 ± 86 m; P < 0.001). 6MWD significantly correlated with age (r = -0.39), height (r = 0.44), body mass index (r = -0.24), and reported physical activity (r = 0.25). 6MWw significantly correlated with age (r = -0.21), height (r = 0.66) and reported physical activity (r = 0.25). The reference equation devised for walk distance was 6MWDm = 622.461 - (1.846 x Ageyears) + (61.503 x Gendermales = 1; females = 0); r2 = 0.300. In an additional group of 85 subjects prospectively studied, the difference between measured and the 6MWD predicted with the equation proposed here was not significant (-3 ± 68 m; P = 0.938). The measured 6MWD represented 99.6 ± 11.9% of the predicted value. We conclude that 6MWD and 6MWw variances were adequately explained by demographic and anthropometric attributes. This reference equation is probably most appropriate for evaluating the exercise capacity of Brazilian patients with chronic diseases.
Resumo:
Epidemiological studies have provided evidence that high consumption of tomatoes effectively reduces the risk of reactive oxygen species (ROS)-mediated diseases such as cancer. Tomatoes are rich sources of lycopene, a potent singlet oxygen-quenching carotenoid. In addition to its antioxidant properties, lycopene shows an array of biological effects including antimutagenic and anticarcinogenic activities. In the present study, the chemopreventive action of lycopene was examined on DNA damage and clastogenic or aneugenic effects of H2O2 and n-nitrosodiethylamine (DEN) in the metabolically competent human hepatoma cell line (HepG2 cells). Lycopene at concentrations of 10. 25, and 50 mu M, was tested under three protocols: before, simultaneously, and after treatment with the mutagen, using the comet and micronucleus assays. Lycopene significantly reduced the genotoxicity and mutagenicity of H2O2 in all of the conditions tested. For DEN, significant reductions of primary DNA damage (comet assay) were detected when the carotenoid (all of the doses) was added in the cell culture medium before or simultaneously with the mutagen. In the micronucleus test, the protective effect of lycopene was observed only when added prior to DEN treatment. In conclusion, our results suggest that lycopene is a suitable agent for preventing chemically-induced DNA and chromosome damage. (C) 2007 Elsevier Ltd. All rights reserved.
Resumo:
OBJETIVO: Verificar se os testes: Volume Expiratório Forçado no 1º segundo (VEF1), Teste de Caminhada de 6 minutos (TC6) e Teste de Escada (TE) se alteram proporcionalmente ao pulmão funcionante ressecado. MÉTODOS: Foram incluídos pacientes candidatos a toracotomia para ressecção pulmonar. No pré-operatório (pré) e no mínimo três meses após a cirurgia (pós), realizaram espirometria, TC6 e TE. O TE foi realizado em escada com 12,16m de altura. O tempo para subir todos os degraus o mais rápido possível foi chamado tempo de escada (tTE). Os cálculos dos valores dos testes preditos para o pós-operatório (ppo) foram realizados conforme o número de segmentos funcionantes perdidos. Os valores pré, ppo e pós foram comparados entre si para cada teste. Estatística: foi utilizada a análise de variância para medidas repetidas (ANOVA), com significância de 5%. RESULTADOS: Foram estudados 40 pacientes. A ressecção pulmonar variou desde o ganho de dois segmentos funcionantes até a perda de 9. Os valores pré, ppo e pós foram respectivamente: VEF1 -pré = 2,6±0,8L, ppo = 2,3±0,8L, pós = 2,3±0,8L (VEF1pré > VEF1ppo = VEF1pós), TC6-pré = 604±63m, ppo = 529±103m, pós = 599±74m (TC6pré = TC6pós > TC6ppo), tTE-pré = 32,9±7,6s, ppo = 37,8±12,1s, pós = 33,7±8,5s (tTEpré = tTEpós < tTEppo). CONCLUSÃO: Nas ressecções pulmonares, este grupo de pacientes perdeu função pulmonar medida através da espirometria, mas não perdeu a capacidade de exercício, medida através dos testes de escada e caminhada.
Resumo:
The present study cross-sectionally investigated the influence of training status, route difficulty and upper body aerobic and anaerobic performance of climbers on the energetics of indoor rock climbing. Six elite climbers (EC) and seven recreational climbers ( RC) were submitted to the following laboratory tests: ( a) anthropometry, (b) upper body aerobic power, and ( c) upper body Wingate test. on another occasion, EC subjects climbed an easy, a moderate, and a difficult route, whereas RC subjects climbed only the easy route. The fractions of the aerobic (WAER), anaerobic alactic (W-PCR) and anaerobic lactic (W-[La(])-) systems were calculated based on oxygen uptake, the fast component of excess post-exercise oxygen uptake, and changes in net blood lactate, respectively. on the easy route, the metabolic cost was significantly lower in EC [ 40.3 ( 6.5) kJ] than in RC [60.1 ( 8.8) kJ] ( P < 0.05). The respective contributions of the WAER, WPCR, and W-[La(])- systems in EC were: easy route = 41.5 (8.1), 41.1 (11.4) and 17.4% (5.4), moderate route = 45.8 (8.4), 34.6 (7.1) and 21.9% (6.3), and difficult route = 41.9 (7.4), 35.8 (6.7) and 22.3% (7.2). The contributions of the WAER, WPCR, and W-[La(])- systems in RC subjects climbing an easy route were 39.7 (5.0), 34.0 (5.8), and 26.3% (3.8), respectively. These results indicate that the main energy systems required during indoor rock climbing are the aerobic and anaerobic alactic systems. In addition, climbing economy seems to be more important for the performance of these athletes than improved energy metabolism.
Resumo:
O objetivo do presente estudo foi desenvolver um snorquel (SNQ) de baixo custo para mensuração de parâmetros cardiorrespiratórios em natação. Para isso, a máscara do analisador de gases VO2000 (MASC) foi adaptada a um SNQ desenvolvido artesanalmente com espaço morto de 250ml. Oito participantes foram submetidos a dois testes incrementais (TI) em cicloergômetro utilizando a MASC e o SNQ. Os TI foram realizados até a exaustão voluntária e foram compostos por estágios de 3min com carga inicial e incrementos de 35W. em ambas as situações, amostras gasosas foram coletadas em intervalos de 10s para determinação dos volumes de oxigênio (VO2), gás carbônico (VCO2), ventilatório (VE) e mensuração da freqüência cardíaca (FC). A comparação dos parâmetros cardiorrespiratórios (VO2, VE, VCO2 e FC) mensurados com o SNQ e a MASC foi realizada com o teste t de Student para amostras dependentes, enquanto que o teste de correlação de Pearson e a análise gráfica de Bland e Altman foram utilizados para verificar as associações e concordância entre parâmetros. em todos os casos, o nível de significância foi de P < 0,05. A adequação das equações de correção para os valores provenientes do SNQ foi verificada pelos erros sistemáticos (bias), aleatórios (precisão) e acurácia (ac). Não foram observadas diferenças significativas entre os valores de VO2, VCO2 e FC obtidos com a MASC e SNQ. Os valores de VE mensurados com o SNQ foram significativamente superiores aos obtidos com a MASC. No entanto, todos os parâmetros apresentaram elevada concordância e coeficiente de correlação (0,88 a 0,97). Além disso, foram verificados reduzidos valores de bias (VO2 = 0,11L/min; VE = 4,11L/min; VCO2 = 0,54L/min; 8,87bpm), precisão (VO2 = 0,24L/min; VE = 11,02L/ min; VCO2 = 0,18L/min; 7,42bpm) e ac (VO2 = 0,27L/min; VE = 11,76L/min; VCO2 = 0,56L/min; 11,56bpm). Desse modo, pode-se concluir que o SNQ desenvolvido neste estudo possibilita a mensuração válida de parâmetros cardiorrespiratórios em natação.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)