1000 resultados para Measurement Campaign
Resumo:
Children with elevated blood pressure are at risk of being hypertensive in adulthood and of developing complications such as ventricular hypertrophy. Obesity is a cause of hypertension. Because the prevalence of obesity is increasing, some authors argue that the systematic screening for hypertension in children and adolescents is justified for early prevention and treatment. Sex, age and height all influence children's blood pressure. When elevated blood pressure is identified, complementary investigations and treatment might be necessary. However, due to the difficulties of obtaining a valid estimate of blood pressure, to the moderate tracking of blood pressure from childhood to adulthood, and the rarity of hypertension cases in childhood, the usefulness of systematic screening of hypertension during childhood is still controversial. Un enfant dont la pression artérielle est élevée a un risque accru d'être hypertendu à l'âge adulte et de présenter des complications telles que l'hypertrophie ventriculaire gauche. L'augmentation de la prévalence de l'obésité justifierait selon certains auteurs le dépistage systématique de l'hypertension dès le plus jeune âge afin d'instaurer des mesures préventives ou curatives précoces. Les normes de pression dépendent du sexe, de l'âge et de la taille de l'enfant. En cas de pression élevée, des investigations complémentaires, voire un traitement, peuvent être indiqués. Au vu des difficultés pour obtenir une mesure fiable, des incertitudes entachant la valeur pronostique d'une pression artérielle élevée et de la rareté des cas d'hypertension, il n'y a pas de consensus sur l'utilité du dépistage systématique de l'hypertension durant l'enfance.
Resumo:
Background Multiple sclerosis (MS) is a demyelinating disease of the central nervous system, which mainly affects young adults. In Finland, approximately 2500 out of 6000 MS patients have relapsing MS and are treated with disease modifying drugs (DMD): interferon- β (INF-β-1a or INF-β-1b) and glatiramer acetate (GA). Depending on the used IFN-β preparation, 2 % to 40 % of patients develop neutralizing antibodies (NAbs), which abolish the biological effects of IFN-β, leading to reduced clinical and MRI detected efficacy. According to the Finnish Current Care Guidelines and European Federation of Neurological Societis (EFNS) guidelines, it is suggested tomeasure the presence of NAbs during the first 24 months of IFN-β therapy. Aims The aim of this thesis was to measure the bioactivity of IFN-β therapy by focusing on the induction of MxA protein (myxovirus resistance protein A) and its correlation to neutralizing antibodies (NAb). A new MxA EIA assay was set up to offer an easier and rapid method for MxA protein detection in clinical practice. In addition, the tolerability and safety of GA were evaluated in patients who haddiscontinued IFN-β therapy due to side effects and lack of efficacy. Results NAbs developed towards the end of 12 months of treatment, and binding antibodies were detectable before or parallel with them. The titer of NAb correlated negatively with the amount of MxA protein and the mean values of preinjection MxA levels never returned to true baseline in NAb negative patients, but tended to drop in the NAb positive group. The test results between MxA EIA and flow cytometric analysis showed significant correlation. GA reduced the relapse rate and was a safe and well-tolerated therapy in IFN-β-intolerant MS patients. Conclusions NAbs inhibit the induction of MxA protein, which can be used as a surrogate marker of the bioactivity of IFN-β therapy. Compared to flow cytometricanalysis and NAb assay, MxA-EIA seemed to be a sensitive and more practical method in clinical use to measure the actual bioactivity of IFN-β treatment, which is of value also from a cost-effective perspective.
Resumo:
The aim of this project is to get used to another kind of programming. Since now, I used very complex programming languages to develop applications or even to program microcontrollers, but PicoCricket system is the evidence that we don’t need so complex development tools to get functional devices. PicoCricket system is the clear example of simple programming to make devices work the way we programmed it. There’s an easy but effective way to program small, devices just saying what we want them to do. We cannot do complex algorithms and mathematical operations but we can program them in a short time. Nowadays, the easier and faster we produce, the more we earn. So the tendency is to develop fast, cheap and easy, and PicoCricket system can do it.
Resumo:
The aim of our study was to present a new headspace-gas chromatography-mass spectrometry (HS-GC-MS) method applicable to the routine determination of hydrogen sulfide (H(2)S) concentrations in biological and gaseous samples. The primary analytical drawback of the GC/MS methods for H(2)S measurement discussed in the literature was the absence of a specific H(2)S internal standard required to perform quantification. Although a deuterated hydrogen sulfide (D(2)S) standard is currently available, this standard is not often used because this standard is expensive and is only available in the gas phase. As an alternative approach, D(2)S can be generated in situ by reacting deuterated chloride with sodium sulfide; however, this technique can lead to low recovery yield and potential isotopic fractionation. Therefore, N(2)O was chosen for use as an internal standard. This method allows precise measurements of H(2)S concentrations in biological and gaseous samples. Therefore, a full validation using accuracy profile based on the β-expectation tolerance interval is presented. Finally, this method was applied to quantify H(2)S in an actual case of H(2)S fatal intoxication.
Resumo:
Strong platelet activation results in a redistribution of negatively charged phospholipids from the cytosolic to the outer leaflet of the cellular membrane. Annexin V has a high affinity to negatively charged phospholipids and can be used to identify procoagulant platelets. Formaldehyde fixation can cause factitious Annexin V binding. Our aim was to evaluate a method for fixing platelets avoiding additional Annexin V binding. We induced expression of negatively charged phospholipids on the surface of a fraction of platelets by combined activation with convulxin and thrombin in the presence of Annexin V-fluorescein isothiocyanate and calcium. Aliquots of resting and activated platelets were fixed with a low concentration, calcium-free formaldehyde solution. Both native platelets and fixed platelets were analyzed by flow cytometry immediately and after a 24-h storage at 4°C. We observed that the percentage of Annexin V positive resting platelets ranged from 1.5 to 9.3% for the native samples and from 0.4 to 12.8% for the fixed samples (P=0.706, paired t-test). The amount of Annexin V positive convulxin/thrombin activated platelets varied from 12.9 to 35.4% without fixation and from 15.3 to 36.3% after formalin fixation (P=0.450). After a 24-h storage at 4°C, Annexin V positive platelets significantly increased both in the resting and in the convulxin/thrombin activated samples of native platelets (both P<0.001), while results for formalin fixed platelets did not differ from baseline values (P=0.318 for resting fixed platelets; P=0.673 for activated fixed platelets). We conclude that platelet fixation with a low concentration, calcium-free formaldehyde solution does not alter the proportion of Annexin V positive platelets. This method can be used to investigate properties of procoagulant platelets by multicolor flow-cytometric analysis requiring fixation steps.
Resumo:
Monitoring the performance is a crucial task for elite sports during both training and competition. Velocity is the key parameter of performance in swimming, but swimming performance evaluation remains immature due to the complexities of measurements in water. The purpose of this study is to use a single inertial measurement unit (IMU) to estimate front crawl velocity. Thirty swimmers, equipped with an IMU on the sacrum, each performed four different velocity trials of 25 m in ascending order. A tethered speedometer was used as the velocity measurement reference. Deployment of biomechanical constraints of front crawl locomotion and change detection framework on acceleration signal paved the way for a drift-free integration of forward acceleration using IMU to estimate the swimmers velocity. A difference of 0.6 ± 5.4 cm · s(-1) on mean cycle velocity and an RMS difference of 11.3 cm · s(-1) in instantaneous velocity estimation were observed between IMU and the reference. The most important contribution of the study is a new practical tool for objective evaluation of swimming performance. A single body-worn IMU provides timely feedback for coaches and sport scientists without any complicated setup or restraining the swimmer's natural technique.
Resumo:
Report on the Iowa Ethics and Campaign Disclosure Board for the year ended June 30, 2009
Measurement of cell microrheology by magnetic twisting cytometry with frequency domain demodulation.
Resumo:
This paper presents a new respiratory impedance estimator to minimize the error due to breathing. Its practical reliability was evaluated in a simulation using realistic signals. These signals were generated by superposing pressure and flow records obtained in two conditions: 1) when applying forced oscillation to a resistance- inertance- elastance (RIE) mechanical model; 2) when healthy subjects breathed through the unexcited forced oscillation generator. Impedances computed (4-32 Hz) from the simulated signals with the new estimator resulted in a mean value which was scarcely biased by the added breathing (errors less than 1 percent in the mean R, I , and E ) and had a small variability (coefficients of variation of R, I, and E of 1.3, 3.5, and 9.6 percent, respectively). Our results suggest that the proposed estimator reduces the error in measurement of respiratory impedance without appreciable extracomputational cost.
Resumo:
ABSTRACT. A dual-wavelength digital holographic microscope to measure absolute volume of living cells is proposed. The optical setup allows us to reconstruct two quantitative phase contrast images at two different wavelengths from a single hologram acquisition. When adding the absorbing dye fast green FCF as a dispersive agent to the extracellular medium, cellular thickness can be univocally determined in the full field of view. In addition to the absolute cell volume, the method can be applied to derive important biophysical parameters of living cells including osmotic membrane water permeability coefficient and the integral intracellular refractive index (RI). Further, the RI of transmembrane flux can be determined giving an indication about the nature of transported solutes. The proposed method is applied to cultured human embryonic kidney cells, Chinese hamster ovary cells, human red blood cells, mouse cortical astrocytes, and neurons.
Resumo:
OBJECTIVE: The estimation of blood pressure is dependent on the accuracy of the measurement devices. We compared blood pressure readings obtained with an automated oscillometric arm-cuff device and with an automated oscillometric wrist-cuff device and then assessed the prevalence of defined blood pressure categories. METHODS: Within a population-based survey in Dar es Salaam (Tanzania), we selected all participants with a blood pressure >/= 160/95 mmHg (n=653) and a random sample of participants with blood pressure <160/95 mmHg (n=662), based on the first blood pressure reading. Blood pressure was reassessed 2 years later for 464 and 410 of the participants, respectively. In these 874 subjects, we compared the prevalence of blood pressure categories as estimated with each device. RESULTS: Overall, the wrist device gave higher blood pressure readings than the arm device (difference in systolic/diastolic blood pressure: 6.3 +/- 17.3/3.7 +/- 11.8 mmHg, P<0.001). However, the arm device tended to give lower readings than the wrist device for high blood pressure values. The prevalence of blood pressure categories differed substantially depending on which device was used, 29% and 14% for blood pressure <120/80 mmHg (arm device versus wrist device, respectively), 30% and 33% for blood pressure 120-139/80-89 mmHg, 17% and 26% for blood pressure 140-159/90-99 mmHg, 12% and 13% for blood pressure 160-179/100-109 mmHg and 13% and 14% for blood pressure >/= 180/110 mmHg. CONCLUSIONS: A large discrepancy in the estimated prevalence of blood pressure categories was observed using two different automatic measurement devices. This emphasizes that prevalence estimates based on automatic devices should be considered with caution.
Resumo:
Audit report of the Iowa Ethics and Campaign Disclosure Board for the year ended June 30, 2010