613 resultados para Maxillofacial
Resumo:
The purpose of this study was to examine the reporting quality of randomised controlled trials (RCTs) published in prosthodontic and implantology journals. Thirty issues of nine journals in prosthodontics and implant dentistry were searched for RCTs, covering the years 2005-2012: The Journal of Prosthetic Dentistry, Journal of Oral Rehabilitation, The International Journal of Prosthodontics, The International Journal of Periodontics & Restorative Dentistry, Clinical Oral Implants Research, Clinical Implant Dentistry & Related Research, The International Journal of Oral & Maxillofacial Implants, Implant Dentistry and Journal of Dentistry. The reporting quality was assessed using a modified Consolidated Standards of Reporting Trials (CONSORT) statement checklist. Data were analysed using descriptive statistics followed by univariable and multivariable examination of statistical associations (α = 0·05). A total of 147 RCTs were identified with a mean CONSORT score of 69·4 (s.d. = 9·7). Significant differences were found among journals with the Journal of Oral Rehabilitation achieving the highest score (80·6, s.d. = 5·5) followed by Clinical Oral Implants Research (73·7, s.d. = 8·3). Involvement of a statistician/methodologist was significantly associated with increased CONSORT scores. Overall, the reporting quality of RCTs in major prosthodontic and implantology journals requires improvement. This is of paramount importance considering that optimal reporting of RCTs is an important prerequisite for clinical decision-making.
Resumo:
PURPOSE Digital developments have led to the opportunity to compose simulated patient models based on three-dimensional (3D) skeletal, facial, and dental imaging. The aim of this systematic review is to provide an update on the current knowledge, to report on the technical progress in the field of 3D virtual patient science, and to identify further research needs to accomplish clinical translation. MATERIALS AND METHODS Searches were performed electronically (MEDLINE and OVID) and manually up to March 2014 for studies of 3D fusion imaging to create a virtual dental patient. Inclusion criteria were limited to human studies reporting on the technical protocol for superimposition of at least two different 3D data sets and medical field of interest. RESULTS Of the 403 titles originally retrieved, 51 abstracts and, subsequently, 21 full texts were selected for review. Of the 21 full texts, 18 studies were included in the systematic review. Most of the investigations were designed as feasibility studies. Three different types of 3D data were identified for simulation: facial skeleton, extraoral soft tissue, and dentition. A total of 112 patients were investigated in the development of 3D virtual models. CONCLUSION Superimposition of data on the facial skeleton, soft tissue, and/or dentition is a feasible technique to create a virtual patient under static conditions. Three-dimensional image fusion is of interest and importance in all fields of dental medicine. Future research should focus on the real-time replication of a human head, including dynamic movements, capturing data in a single step.
Resumo:
PURPOSE To identify the influence of fixed prosthesis type on biologic and technical complication rates in the context of screw versus cement retention. Furthermore, a multivariate analysis was conducted to determine which factors, when considered together, influence the complication and failure rates of fixed implant-supported prostheses. MATERIALS AND METHODS Electronic searches of MEDLINE (PubMed), EMBASE, and the Cochrane Library were conducted. Selected inclusion and exclusion criteria were used to limit the search. Data were analyzed statistically with simple and multivariate random-effects Poisson regressions. RESULTS Seventy-three articles qualified for inclusion in the study. Screw-retained prostheses showed a tendency toward and significantly more technical complications than cemented prostheses with single crowns and fixed partial prostheses, respectively. Resin chipping and ceramic veneer chipping had high mean event rates, at 10.04 and 8.95 per 100 years, respectively, for full-arch screwed prostheses. For "all fixed prostheses" (prosthesis type not reported or not known), significantly fewer biologic and technical complications were seen with screw retention. Multivariate analysis revealed a significantly greater incidence of technical complications with cemented prostheses. Full-arch prostheses, cantilevered prostheses, and "all fixed prostheses" had significantly higher complication rates than single crowns. A significantly greater incidence of technical and biologic complications was seen with cemented prostheses. CONCLUSION Screw-retained fixed partial prostheses demonstrated a significantly higher rate of technical complications and screw-retained full-arch prostheses demonstrated a notably high rate of veneer chipping. When "all fixed prostheses" were considered, significantly higher rates of technical and biologic complications were seen for cement-retained prostheses. Multivariate Poisson regression analysis failed to show a significant difference between screw- and cement-retained prostheses with respect to the incidence of failure but demonstrated a higher rate of technical and biologic complications for cement-retained prostheses. The incidence of technical complications was more dependent upon prosthesis and retention type than prosthesis or abutment material.
Resumo:
PURPOSE The objective of this study was to evaluate stiffness, strength, and failure modes of monolithic crowns produced using computer-aided design/computer-assisted manufacture, which are connected to diverse titanium and zirconia abutments on an implant system with tapered, internal connections. MATERIALS AND METHODS Twenty monolithic lithium disilicate (LS2) crowns were constructed and loaded on bone level-type implants in a universal testing machine under quasistatic conditions according to DIN ISO 14801. Comparative analysis included a 2 × 2 format: prefabricated titanium abutments using proprietary bonding bases (group A) vs nonproprietary bonding bases (group B), and customized zirconia abutments using proprietary Straumann CARES (group C) vs nonproprietary Astra Atlantis (group D) material. Stiffness and strength were assessed and calculated statistically with the Wilcoxon rank sum test. Cross-sections of each tested group were inspected microscopically. RESULTS Loaded LS2 crowns, implants, and abutment screws in all tested specimens (groups A, B, C, and D) did not show any visible fractures. For an analysis of titanium abutments (groups A and B), stiffness and strength showed equally high stability. In contrast, proprietary and nonproprietary customized zirconia abutments exhibited statistically significant differences with a mean strength of 366 N (Astra) and 541 N (CARES) (P < .05); as well as a mean stiffness of 884 N/mm (Astra) and 1,751 N/mm (CARES) (P < .05), respectively. Microscopic cross-sections revealed cracks in all zirconia abutments (groups C and D) below the implant shoulder. CONCLUSION Depending on the abutment design, prefabricated titanium abutment and proprietary customized zirconia implant-abutment connections in conjunction with monolithic LS2 crowns had the best results in this laboratory investigation.
Resumo:
PURPOSE To compare time-efficiency in the production of implant crowns using a digital workflow versus the conventional pathway. MATERIALS AND METHODS This prospective clinical study used a crossover design that included 20 study participants receiving single-tooth replacements in posterior sites. Each patient received a customized titanium abutment plus a computer-aided design/computer-assisted manufacture (CAD/CAM) zirconia suprastructure (for those in the test group, using digital workflow) and a standardized titanium abutment plus a porcelain-fused-to-metal crown (for those in the control group, using a conventional pathway). The start of the implant prosthetic treatment was established as the baseline. Time-efficiency analysis was defined as the primary outcome, and was measured for every single clinical and laboratory work step in minutes. Statistical analysis was calculated with the Wilcoxon rank sum test. RESULTS All crowns could be provided within two clinical appointments, independent of the manufacturing process. The mean total production time, as the sum of clinical plus laboratory work steps, was significantly different. The mean ± standard deviation (SD) time was 185.4 ± 17.9 minutes for the digital workflow process and 223.0 ± 26.2 minutes for the conventional pathway (P = .0001). Therefore, digital processing for overall treatment was 16% faster. Detailed analysis for the clinical treatment revealed a significantly reduced mean ± SD chair time of 27.3 ± 3.4 minutes for the test group compared with 33.2 ± 4.9 minutes for the control group (P = .0001). Similar results were found for the mean laboratory work time, with a significant decrease of 158.1 ± 17.2 minutes for the test group vs 189.8 ± 25.3 minutes for the control group (P = .0001). CONCLUSION Only a few studies have investigated efficiency parameters of digital workflows compared with conventional pathways in implant dental medicine. This investigation shows that the digital workflow seems to be more time-efficient than the established conventional production pathway for fixed implant-supported crowns. Both clinical chair time and laboratory manufacturing steps could be effectively shortened with the digital process of intraoral scanning plus CAD/CAM technology.
Resumo:
PURPOSE The aim of this short communication was to analyze time-dependent changes of the supraimplant mucosa architecture in the esthetic zone. MATERIALS AND METHODS Five patients underwent single-tooth replacement with implant crowns in the anterior maxilla. The supraimplant soft tissue was conditioned with fixed provisional crowns. Quadrantlike digital impressions were taken with an intraoral optical scanning device at three time points: t0, immediately after removal of the provisional (baseline); t1, after 5 minutes; and t2, after 10 minutes. To analyze time-dependent mucosal changes, the corresponding digital files were superimposed for each patient, and baseline (t0) scans were compared with t1 and t2 scans, respectively. Wilcoxon rank sum tests were used for statistical calculations with a strict level of significance at P < .01. RESULTS Mean values for supraimplant soft tissue changes were statistically significantly different after 5 minutes (5.5%; standard deviation ± 0.3%) in comparison to the results after 10 minutes (21.7%; standard deviation ± 1.8%). The direction of mucosa shrinkage showed a trend toward palatal sites. CONCLUSION Based on the findings of this analysis, changes in supraimplant mucosa architecture seem to be affected only slightly during the first 5 minutes after removal of soft tissue support.
Resumo:
Technical complications in implant prosthetic cases represent a major challenge in dentistry. This case report describes minimally invasive management to recover an implant with a fractured remnant of a zirconia abutment, including provisional rehabilitation during a sequential treatment protocol in the esthetic zone. A patient was treated with a screw-retained one-piece implant-supported reconstruction made of a customized zirconia abutment with direct ceramic veneering in the maxillary right central incisor position. During the prosthetic try-in, a fracture in the apical portion of the abutment was evident. The first rescue attempt led to fracture of the retrieval instrument. Immediately, an individualized wired construction was applied to bond the existing fractured reconstruction to the neighboring teeth to maintain the peri-implant mucosal architecture. Because the implant screw canal was blocked, a customized round bur had to be manufactured and was placed in the implant axis with a specific bracket tool from the service set to protect the interior implant threads. Then, the drills of the service set were guided by the newly created access to remove the fractured remnants. The implant screw was retapped and the area rinsed with chlorhexidine solution. All remnants were removed without the need for surgical intervention. Neither the implant connection nor the bone-to-implant interface was damaged. The stepwise treatment approach with the customized round bur combined with the system-specific drills of the service set saved the blocked implant so that the patient could be successfully rehabilitated with a new implant reconstruction.
Resumo:
PURPOSE The aim of this study was to analyze the patient pool referred to a specialty clinic for implant surgery over a 3-year period. MATERIALS AND METHODS All patients receiving dental implants between 2008 and 2010 at the Department of Oral Surgery and Stomatology were included in the study. As primary outcome parameters, the patients were analyzed according to the following criteria: age, sex, systemic diseases, and indication for therapy. For the inserted implants, the type of surgical procedure, the types of implants placed, postsurgical complications, and early failures were recorded. A logistic regression analysis was performed to identify possible local and systemic risk factors for complications. As a secondary outcome, data regarding demographics and surgical procedures were compared with the findings of a historic study group (2002 to 2004). RESULTS A total of 1,568 patients (792 women and 776 men; mean age, 52.6 years) received 2,279 implants. The most frequent indication was a single-tooth gap (52.8%). Augmentative procedures were performed in 60% of the cases. Tissue-level implants (72.1%) were more frequently used than bone-level implants (27.9%). Regarding dimensions of the implants, a diameter of 4.1 mm (59.7%) and a length of 10 mm (55.0%) were most often utilized. An early failure rate of 0.6% was recorded (13 implants). Patients were older and received more implants in the maxilla, and the complexity of surgical interventions had increased when compared to the patient pool of 2002 to 2004. CONCLUSION Implant therapy performed in a surgical specialty clinic utilizing strict patient selection and evidence-based surgical protocols showed a very low early failure rate of 0.6%.
Resumo:
PURPOSE To analyze the indications and frequency for three-dimensional (3D) imaging for implant treatment planning in a pool of patients referred to a specialty clinic over a 3-year period. MATERIALS AND METHODS All patients who received dental implants between 2008 and 2010 at the Department of Oral Surgery and Stomatology at the University of Bern were included in the study. The influence of age, gender, and time of treatment (2008 to 2010) on the frequency of use of two-dimensional (2D) radiographic imaging modalities alone or in combination with 3D cone beam computed tomography (CBCT) scans was analyzed. Furthermore, the influence of the indication, location, and need for bone augmentation on the frequency of use of 2D imaging modalities alone or in combination with CBCT was evaluated. RESULTS In all, 1,568 patients (792 women and 776 men) received 2,279 implants. Overall, 633 patients (40.4%) were analyzed with 2D imaging procedures alone. CBCT was performed in 935 patients (59.6%). There was a statistically significant increase in CBCT between 2008 and 2010. Patients older than 55 years received a CBCT scan in addition to 2D radiographic imaging statistically significantly more often. Additional 3D imaging was most frequently performed in the posterior maxilla, whereas 2D radiographs alone exhibited the highest frequency in the anterior mandible. The combination of 2D with CBCT was used predominantly for implant placement with simultaneous or staged guided bone regeneration or sinus elevation. CONCLUSION Based on these findings from a specialty clinic, the use of additional CBCT imaging for implant treatment planning is influenced by the indication, location, local anatomy (including the need for bone augmentation), and the age of the patient.
Resumo:
Intraoral devices for bite-force sensing have several applications in odontology and maxillofacial surgery, as bite-force measurements provide additional information to help understand the characteristics of bruxism disorders and can also be of help for the evaluation of post-surgical evolution and for comparison of alternative treatments. A new system for measuring human bite forces is proposed in this work. This system has future applications for the monitoring of bruxism events and as a complement for its conventional diagnosis. Bruxism is a pathology consisting of grinding or tight clenching of the upper and lower teeth, which leads to several problems such as lesions to the teeth, headaches, orofacial pain and important disorders of the temporomandibular joint. The prototype uses a magnetic field communication scheme similar to low-frequency radio frequency identification (RFID) technology (NFC). The reader generates a low-frequency magnetic field that is used as the information carrier and powers the sensor. The system is notable because it uses an intra-mouth passive sensor and an external interrogator, which remotely records and processes information regarding a patient?s dental activity. This permits a quantitative assessment of bite-force, without requiring intra-mouth batteries, and can provide supplementary information to polysomnographic recordings, current most adequate early diagnostic method, so as to initiate corrective actions before irreversible dental wear appears. In addition to describing the system?s operational principles and the manufacture of personalized prototypes, this report will also demonstrate the feasibility of the system and results from the first in vitro and in vivo trials.
Resumo:
La ricerca di nuove strategie per la rigenerazione ossea rappresenta un focus di interesse centrale per migliorare la gestione di casi clinici complessi nell’ambito della chirurgia orale e maxillo-facciale. Uno degli approcci più utilizzati in tale contesto si basa sull’utilizzo di molecole con proprietà osteoinduttive e molte sostanze sono state fino ad oggi sperimentate. E’ noto in letteratura che gli androgeni svolgono un ruolo chiave nella regolazione della morfogenesi ossea e nel mantenimento della sua omeostasi durante il corso della vita. Questo lavoro di tesi nasce dall’ipotesi che la somministrazione locale di tali ormoni, eventualmente combinata a materiali da innesto, possa favorire la guarigione di difetti ossei. Stando a questa premessa, sono stati valutati gli effetti dello steroide sintetico Stanozololo sulla rigenerazione ossea in diversi settings sperimentali. La tesi è strutturata secondo un percorso che segue le fasi della ricerca, attraverso sperimentazioni in vitro e in vivo; ogni capitolo può essere approcciato come uno studio a sé stante, corrispondente ad una determinata tappa dell’iter sperimentale. Sulla base di questi intenti, viene fornito inizialmente un quadro d’insieme circa gli effetti degli androgeni sull’osso. A seguire, è presentata una sperimentazione in vitro nella linea cellulare SaOS-2. Infine, è proposta un’innovativa metodologia di analisi per lo studio della rigenerazione ossea nel modello di ratto, ove viene testata la somministrazione locale di Stanozololo combinato a materiale da innesto.
Resumo:
Physician training has greatly benefitted from insights gained in understanding the manner in which experts search medical images for abnormalities. The aims of this study were to compare the search patterns of 30 fourth-year dental students and 15 certified oral and maxillofacial radiologists (OMRs) over panoramic images and to determine the most robust variables for future studies involving image visualization. Eye tracking was used to capture the eye movement patterns of both subject groups when examining 20 panoramic images classified as normal or abnormal. Abnormal images were further subclassified as having an obvious, intermediate, or subtle abnormality. The images were presented in random order to each participant, and data were collected on duration of the participants’ observations and total distance tracked, time to first eye fixation, and total duration and numbers of fixations on and off the area of interest (AOI). The results showed that the OMRs covered greater distances than the dental students (p<0.001) for normal images. For images of pathosis, the OMRs required less total time (p<0.001), made fewer eye fixations (p<0.01) with fewer saccades (p<0.001) than the students, and required less time before making the first fixation on the AOI (p<0.01). Furthermore, the OMRs covered less distance (p<0.001) than the dental students for obvious pathoses. For investigations of images of pathosis, time to first fixation is a robust parameter in predicting ability. For images with different levels of subtlety of pathoses, the number of fixations, total time spent, and numbers of revisits are important parameters to analyze when comparing observer groups with different levels of experience.
Resumo:
Physician training has greatly benefitted from insights gained in understanding the manner in which experts search medical images for abnormalities. The aims of this study were to compare the search patterns of 30 fourth-year dental students and 15 certified oral and maxillofacial radiologists (OMRs) over panoramic images and to determine the most robust variables for future studies involving image visualization. Eye tracking was used to capture the eye movement patterns of both subject groups when examining 20 panoramic images classified as normal or abnormal. Abnormal images were further subclassified as having an obvious, intermediate, or subtle abnormality. The images were presented in random order to each participant, and data were collected on duration of the participants’ observations and total distance tracked, time to first eye fixation, and total duration and numbers of fixations on and off the area of interest (AOI). The results showed that the OMRs covered greater distances than the dental students (p<0.001) for normal images. For images of pathosis, the OMRs required less total time (p<0.001), made fewer eye fixations (p<0.01) with fewer saccades (p<0.001) than the students, and required less time before making the first fixation on the AOI (p<0.01). Furthermore, the OMRs covered less distance (p<0.001) than the dental students for obvious pathoses. For investigations of images of pathosis, time to first fixation is a robust parameter in predicting ability. For images with different levels of subtlety of pathoses, the number of fixations, total time spent, and numbers of revisits are important parameters to analyze when comparing observer groups with different levels of experience.
Resumo:
vol. XII. Pathology of the acute respiratory diseases, and of gas gangrene following war wounds, by G.R. Callender and J.F. Coupal. 1929- vol. XIII. pt. 1. Physical reconstruction and vocational education, by A.G. Crane. pt. 2. The Army nurse corps, by Julia C. Stimson. 1927- vol. XIV. Medical aspects of gas warfare, by W.D. Bancroft, H.C. Bradley [and others] 1926.- vol. XV. Statistics, pt. 1. Army anthropology, based on observations made on draft recruits, 1917-1918, and on veterans at demobilization, 1919, by C.B. Davenport and A.G. Love. 1921. pt. 2. Medical and casualty statistics based on the medical records of the United States Army, April 1, 1917, to December 31, 1919, inclusive, by A.G. Love. 1925.