906 resultados para Matrix converters


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this article, we propose new control charts for monitoring the mean vector and the covariance matrix of bivariate processes. The traditional tools used for this purpose are the T (2) and the |S| charts. However, these charts have two drawbacks: (1) the T (2) and the |S| statistics are not easy to compute, and (2) after a signal, they do not distinguish the variable affected by the assignable cause. As an alternative to (1), we propose the MVMAX chart, which only requires the computation of sample means and sample variances. As an alternative to (2), we propose the joint use of two charts based on the non-central chi-square statistic (NCS statistic), named as the NCS charts. Once the NCS charts signal, the user can immediately identify the out-of-control variable. In general, the synthetic MVMAX chart is faster than the NCS charts and the joint T (2) and |S| charts in signaling processes disturbances.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The capacitor-commutated converter (CCC) has frequently been used in the conception of HVDC systems connected to busbars with low short circuit level. This alternative arrangement, in substitution to the conventional ones, guarantees less sensitive operational conditions to problems related with the commutation failure in the inverters besides supplying part of the reactive energy to be compensated. Studies related with its performance in steady and transient states have been presented in several works, however its behavior as harmonic source is still little explored. This work presents preliminary studies focusing the generation of characteristic harmonics by this type of converter. Subjects related with the amplification of the harmonic magnitudes are investigated and compared considering similar arrangements of conventional static converters (LCC) and CCC schemes. It is also analyzed the harmonic generation on the dc side of the installation and its influence on the ac side harmonics. The results are obtained from simulations in the time domain in PSpice environment and they clearly illustrate the operational differences between the L CC and the CCC schemes with regard to characteristic harmonic generation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a pole placement method using both the augmented Jacobian and the corresponding system transfer function matrices. From the manipulation of these matrices a straightforward approach results to get the coefficients of a non-linear system, whose solution gives the parameters of the stabilizers that can provide a pre-specified minimum damping to the system. (C) 2001 Elsevier B.V. Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Today, the trend within the electronics industry is for the use of rapid and advanced simulation methodologies in association with synthesis toolsets. This paper presents an approach developed to support mixed-signal circuit design and analysis. The methodology proposed shows a novel approach to the problem of developing behvioural model descriptions of mixed-signal circuit topologies, by construction of a set of subsystems, that supports the automated mapping of MATLAB (R)/SINIULINK (R) models to structural VHDL-AMS descriptions. The tool developed, named (MSSV)-S-2, reads a SIMULINK (R) model file and translates it to a structural VHDL-AMS code. It also creates the file structure required to simulate the translated model in the SystemVision (TM). To validate the methodology and the developed program, the DAC08, AD7524 and AD5450 data converters were studied and initially modelled in MATLAB (R)/SIMULINK (R). The VHDL-AMS code generated automatically by (MSSV)-S-2, (MATLAB (R)/SIMULINK (R) to SystemVision (TM)), was then simulated in the SystemVision (TM). The simulation results show that the proposed approach, which is based on VHDL-AMS descriptions of the original model library elements, allows for the behavioural level simulation of complex mixed-signal circuits.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a new family of pulsewidth-modulated (PWM) converters, featuring soft commutation of the semiconductors at zero current (ZC) in the transistors and zero voltage (ZV) in the rectifiers, Besides operating at constant frequency and with reduced commutation losses, these new converters have output characteristics similar to the hard-switching-PWM counterpart, which means that there is no circulating reactive energy that would cause large conduction losses, the new family of zero-current-switching (ZCS)-PWM converters is suitable for high-power applications using insulated gate bipolar transistors (IGBT's). The advantages of the new ZCS-PWM boast converter employing IGBT's, rated at 1.6 kW and operating at 20 kHz, are presented, This new ZCS operation can reduce the average total power dissipation in the semiconductors practically by half, when compared with the hard-switching method, This new ZCS-PWM boost converter is suitable for high-power applications using Ie;BT's in power-factor correction, the principle of operation, theoretical analysis, and experimental results of the new ZCS-PWM boost converter are provided in this paper to verify the performance of this new family of converters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work proposes a methodology to generalize the Y-connections for 12- and 18-pulse autotransformers. A single mathematical expression, obtained through simple trigonometric operations, represents all the connections. The proposed methodology allows choosing any ratio between the input and the output voltages. The converters can operate either as step-up or as step-down voltage. To simplify the design of the windings, graphics are generated to calculate the turn-ratio and the polarity of each secondary winding, with respect to the primary winding. A design example, followed by digital simulations, illustrates the presented steps. Experimental results of two prototypes (12 and 18 pulses) are presented. The results also show that high power factor is an inherent characteristic of multi-pulse converters, without any active or passive power factor pre-regulators needs. (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents interactive simulation tools to support the enhancement of power electronics education considering DC to DC converters. These interactive tools make use of the benefits of Java language to provide a dynamic and interactive visualization of simulations in steady-state for idealized non-isolated DC to DC converters. Additionally, this paper discusses the features and the usage of the interactive educational tools to serve as a first design tool for the laboratory experiments in the power electronics courses. In this way, some results were confronted with a well-known simulator package and with experimental results in order to validate the developed interactive simulation tools.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Structural Health Monitoring (SHM) has diverse potential applications, and many groups work in the development of tools and techniques for monitoring structural performance. These systems use arrays of sensors and can be integrated with remote or local computers. There are several different approaches that can be used to obtain information about the existence, location and extension of faults by non destructive tests. In this paper an experimental technique is proposed for damage location based on an observability grammian matrix. The dynamic properties of the structure are identified through experimental data using the eigensystem realization algorithm (ERA). Experimental tests were carried out in a structure through varying the mass of some elements. Output signals were obtained using accelerometers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The study of algorithms for active vibration control in smart structures is an area of interest, mainly due to the demand for better performance of mechanical systems, such as aircraft and aerospace structures. Smart structures, formed using actuators and sensors, can improve the dynamic performance with the application of several kinds of controllers. This article describes the application of a technique based on linear matrix inequalities (LMI) to design an active control system. The positioning of the actuators, the design of a robust state feedback controller and the design of an observer are all achieved using LMI. The following are considered in the controller design: limited actuator input, bounded output (energy) and robustness to parametric uncertainties. Active vibration control of a flat plate is chosen as an application example. The model is identified using experimental data by an eigensystem realization algorithm (ERA) and the placement of the two piezoelectric actuators and single sensor is determined using a finite element model (FEM) and an optimization procedure. A robust controller for active damping is designed using an LMI framework, and a reduced model with observation and control spillover effects is implemented using a computer. The simulation results demonstrate the efficacy of the approach, and show that the control system increases the damping in some of the modes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Heart failure is associated with a skeletal muscle myopathy with cellular and extracellular alterations. The hypothesis of this investigation is that extracellular changes may be associated with enhanced mRNA expression and activity of matrix metalloproteinases (MMP). We examined MMP mRNA expression and MMP activity in Soleus (SOL), extensor digitorum longus (EDL), and diaphragm (DIA) muscles of young Wistar rat with monocrotaline-induced heart failure. Rats injected with saline served as age-matched controls. MMP2 and MMP9 mRNA contents were determined by RT-PCR and MMP activity by electrophoresis in gelatin-containing polyacrylamide gels in the presence of SDS under non-reducing conditions. Heart failure increased MMP9 mRNA expression and activity in SOL, EDL and DIA and MMP2 mRNA expression in DIA. These results suggest that MMP changes may contribute to the skeletal muscle myopathy during heart failure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: Avaliar a expressão da metaloprotease de matriz (MMP)-9 nos pterígios. MÉTODOS: Foi realizado na Faculdade de Medicina de Botucatu estudo prospectivo, aleatório, com o intuito de avaliar a expressão da metaloprotease de matriz na cápsula de Tenon normal e de pterígios primários e recidivados, usando o método da imuno-histoquímica e o sistema computadorizado de análise de imagem. Os resultados foram avaliados estatisticamente. RESULTADOS: A expressão da metaloprotease de matriz foi semelhante na cápsula de Tenon normal e nos pterígios primários e recidivados. CONCLUSÃO: A expressão da metaloprotease de matriz na cápsula de Tenon normal e nos pterígios primários ou recidivados é semelhante, o que nos leva a concluir que esta metaloprotease de matriz não esteja envolvida na gênese ou na recidiva do pterígio.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A matriz extracelular (MEC) desempenha um papel importante em lesões hepáticas crônicas e tem sido estudada em modelos de intoxicação experimental. em bovinos, no entanto, não há estudos específicos sobre a MEC hepática normal ou com lesões crônicas. Por isso, foi desenvolvido um modelo de intoxicação experimental hepático usando Senecio brasilliensis, uma planta que contém alcalóides pirrolizidínicos e causa lesão hepática dependente da dose. Cinco bezerros receberam por via oral, 0.38g/kg de folhas secas por 24 dias. Biópsias hepáticas foram obtidas a cada 15 dias durante 60 dias. Sinais clínicos de complicações digestivas surgiram da terceira semana do experimento. Um bezerro morreu aos 45 dias e os outros quatro foram avaliados até os 60 dias. As biópsias hepáticas foram processadas para microscopia óptica, imuno-histoquímica e microscopia eletrônica de transmissão. No trigésimo dia, as lesões hepáticas eram progessivas caracterizadas por vacuolização hepatocelular, necrose, apoptose, megalocitose, e fibrose centrolobular, pericelular e portal. Foram realizadas avaliações quantitativas e semi-quantitativas de componentes da MEC hepática antes e após o aparecimento das lesões. Foi realizada morfometria do colágeno total e do sistema de fibras elásticas. Colágeno total e colágenos tipos I e III aumentaram progressivamente em todos os locais do fígado. Mudanças na localização, quantidade e disposição do sistema de fibras elásticas foram também observadas. Houve um aumento significativo de células de Kupffer aos 30 dias e de células sinusoidais totais aos 45 e 60 dias. As lesões hepáticas neste experimento foram progressivas mesmo após a remoção da planta. Lesões de fibrose severa foram localizadas principalmente nos espaços porta, seguido por fibrose veno-oclusiva e pericelular. Os colágenos tipo I e tipo III foram observados no fígado normal e no fígado dos bezerros afetados, com predomínio do tipo I. Nos bezerros afetados o aumento do colágeno total e do sistema de fibras elásticas foi paralelo ao aumento no número das células sinusoidais.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Este estudo teve como objetivo avaliar a expressão das metaloproteinases 2 (MMP-2) e 9 (MMP-9) em próstatas caninas normais e com desordens proliferativas, verificando o papel dessas enzimas na remodelação da matriz extracelular (MEC) e no processo de invasão tecidual. Um total de 355 amostras prostáticas foram obtidas, sendo 36 (10,1%) normais, 46 (13,0%) com hiperplasia prostática benigna (HPB), 128 (36,1%) com atrofia inflamatória proliferativa (PIA), 74 (20,8%) com neoplasia intraepitelial prostática (PIN) e 71 (20,0%) com carcinoma prostático (CP). Houve diferença de imunomarcação citoplasmática para MMP-2 e MMP-9 entre o epitélio acinar e o estroma periacinar, quanto aos diferentes diagnósticos. Observou-se correlação entre a expressão de MMP-2 e MMP-9 em relação ao número de células marcadas no epitélio acinar e estroma periacinar, bem como para a intensidade de marcação das células estromais periacinares em próstatas caninas com PIA. Conclui-se que há variação na expressão de MMP-2 e MMP-9 em próstatas caninas de acordo com a lesão, com menor expressão em próstatas caninas normais e com HPB, e maior naquelas com PIA, PIN e CP. Ainda, o microambiente inflamatório na PIA influencia a atividade de ambas as enzimas.