982 resultados para Materia medica and therapeutics
Resumo:
Background and Objective: Dispensing medicines into compliance aids is a common practice in pharmacy contrary to manufacturers’ advice and studies have shown the appearance of light-sensitive tablets is compromised by such storage; we previously found evidence of reduced bioavailability at elevated temperature and humidity. Our objective was to examine the physicochemical stability of two generic atenolol tablets in different compliance aids and with aspirin co-storage at room temperature and at 40 °C/75% relative humidity. Methods: The physicochemical stability of atenolol tablets was evaluated after 28 days of storage and compared with controls by examining visual appearance, weight, disintegration, dissolution, friability and hardness to accepted standards and using a previously validated HPLC method for chemical assay. Results and Discussion: The response to storage was brand-dependent and not straightforward. With one make of atenolol (Alpharma), storage in compliance aids even at room temperature impacted on physical stability, reducing tablet hardness, with storage in Dosett® exerting a greater impact than storage in Medidos® (t-test P < 0·001). Co-storage at elevated temperature and humidity also impacted on the appearance of non-coated aspirin tablets (Angette™). The chemical stability of atenolol was not affected and we did not find evidence of changes to bioavailability with either make. Certainly data for one atenolol make (CP Pharmaceuticals) co-stored with aspirin (Angette™ and Nu-Seals) in both compliance aids at room temperature provided evidence of short-term stability. But medicines are dispensed into compliance aids in multi-factorial ways so our study highlights not only the lack of evidence but also a realization that evidence to support real practice may not be accomplished through research. Conclusion: Reassuring practitioners of the continued stability of medicines in compliance aids under the countless condition in which they are dispensed in practice may requires a different approach involving medical device regulators and more definitive professional guidance.
Resumo:
Background: This study was carried out as part of a European Union funded project (PharmDIS-e+), to develop and evaluate software aimed at assisting physicians with drug dosing. A drug that causes particular problems with drug dosing in primary care is digoxin because of its narrow therapeutic range and low therapeutic index. Objectives: To determine (i) accuracy of the PharmDIS-e+ software for predicting serum digoxin levels in patients who are taking this drug regularly; (ii) whether there are statistically significant differences between predicted digoxin levels and those measured by a laboratory and (iii) whether there are differences between doses prescribed by general practitioners and those suggested by the program. Methods: We needed 45 patients to have 95% Power to reject the null hypothesis that the mean serum digoxin concentration was within 10% of the mean predicted digoxin concentration. Patients were recruited from two general practices and had been taking digoxin for at least 4 months. Exclusion criteria were dementia, low adherence to digoxin and use of other medications known to interact to a clinically important extent with digoxin. Results: Forty-five patients were recruited. There was a correlation of 0·65 between measured and predicted digoxin concentrations (P < 0·001). The mean difference was 0·12 μg/L (SD 0·26; 95% CI 0·04, 0·19, P = 0·005). Forty-seven per cent of the patients were prescribed the same dose as recommended by the software, 44% were prescribed a higher dose and 9% a lower dose than recommended. Conclusion: PharmDIS-e+ software was able to predict serum digoxin levels with acceptable accuracy in most patients.
Resumo:
We review recent progress in understanding the role of sea ice, land surface, stratosphere, and aerosols in decadal-scale predictability and discuss the perspectives for improving the predictive capabilities of current Earth system models (ESMs). These constituents have received relatively little attention because their contribution to the slow climatic manifold is controversial in comparison to that of the large heat capacity of the oceans. Furthermore, their initialization as well as their representation in state-of-the-art climate models remains a challenge. Numerous extraoceanic processes that could be active over the decadal range are proposed. Potential predictability associated with the aforementioned, poorly represented, and scarcely observed constituents of the climate system has been primarily inspected through numerical simulations performed under idealized experimental settings. The impact, however, on practical decadal predictions, conducted with realistically initialized full-fledged climate models, is still largely unexploited. Enhancing initial-value predictability through an improved model initialization appears to be a viable option for land surface, sea ice, and, marginally, the stratosphere. Similarly, capturing future aerosol emission storylines might lead to an improved representation of both global and regional short-term climatic changes. In addition to these factors, a key role on the overall predictive ability of ESMs is expected to be played by an accurate representation of processes associated with specific components of the climate system. These act as “signal carriers,” transferring across the climatic phase space the information associated with the initial state and boundary forcings, and dynamically bridging different (otherwise unconnected) subsystems. Through this mechanism, Earth system components trigger low-frequency variability modes, thus extending the predictability beyond the seasonal scale.
Resumo:
Objective: To assess the bioequivalence of three ibuprofen formulations (Test formulation: ibuprofen (400 mg capsule) manufactured by Cardinal Health Brasil 402 Ltda. (Sorocaba, Brazil) and licensed to Boehringer Ingelheim do Brasil Quim. e Farm. Ltda. (Sao Paulo, Brazil); Reference formulation (1): ibuprofen (Advil (R); 2 x 200 mg coated tablet) from Wyeth-Whitehall Ltda. (Itapevi, Brazil); Reference formulation (2): ibuprofen (Alivium (R); 8 ml x 50 mg/ml solution) from Schering Plough S.A. (Rio de Janeiro, Brazil)) in 24 healthy volunteers of both sexes. Methods: The study was conducted using an open, randomized, three-period crossover design with at least 5-day washout interval. Plasma samples were obtained over a 24-h period. Plasma ibuprofen concentrations were analyzed by liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) with negative ion electrospray ionization using multiple reaction monitoring (MRM). The following pharmacokinetic parameters were obtained from the ibuprofen plasma concentration vs. time curves: AUC(last), AUC(trunctmax) AUC(inf) and C-max. Results: The limit of quantification for ibuprofen was 0.1 mu g x ml(-1). The geometric mean with corresponding 90% confidence interval (CI) for Test/Reference (1) percent ratios were 114.24% (90% CI = 105.67, 123.50%) for C-max, 98.97% (90% CI = 94.69, 103.44%) for AUC(last) and 99.40% (90% CI = 95.21, 103.78%) for AUCinf. The geometric mean and respective 90% confidence interval (CI) for Test/Reference (2) percent ratios were 108.38% (90% Cl = 100.195, 117.25%) for C-max, 100.79% (90% CI = 96.39, 105.40%) for AUC(last) and 101.26% (90% CI = 96.94, 105.77%) for AUC(inf); t(max) for the 400 mg Test capsule was shorter than that for the 2 x 200 mg Reference (1) tablets (p < 0.002). Conclusion: Since the 90% CI for AUC(last), AUC(inf) and C-max ratios were within the 80 - 125% interval proposed by the US FDA, it was concluded that ibuprofen formulation manufactured by Cardinal Health Brasil 402 Ltda. and licensed to Boehringer Ingelheim do Brasil Quim. e Farm. Ltda. is bioequivalent to the Advil (R) and Alivium (R) formulations with regard to both the rate and the extent of absorption.
Resumo:
Angiotensin II (Ang II) and its transmembrane AT(1) receptor were selected in order to test an innovative strategy that might allow the assessment of the agonist binding site in the receptor molecule. With the use of the 2,2,6,6-tetramethylpiperidine-1-oxyl-4-amino-4-carboxylic acid (TOAC) paramagnetic probe, a biologically active agonist (TOAC(1)-Ang II), as well as an inactive control (TOAC(4)-Ang II) analogs were mixed in solution with various synthesized AT(1) fragments. Comparative intermolecular interactions, as estimated by analyzing the EPR spectra of solutions, suggested the existence of an agonist binding site containing a sequence composed of portions of the N-terminal (13-17) and the third extracellular loop (266-278) fragments of the AT(1) molecule. Therefore, this combined EPR-TOAC approach shows promise as an alternative for use also in other applications related to specific intermolecular association processes.
Resumo:
This study evaluated the adverse effects of oral firocoxib in dogs. Six dogs (20.2 +/- 6.3 kg) were studied. Values for complete blood count (CBC), serum urea, creatinine, alanine transaminase, alanine phosphatase, -glutamyl transferase, occult blood in feces, platelet aggregation, and buccal mucosal bleeding time were measured before and 7, 14, 21, and 29 days after SID treatment with firocoxib 5.3 +/- 0.34 mg/kg (FG) or lactose 1 mg/kg (LG) for 2 8 days, in a randomized crossover study. Gastrointestinal (GI) tract endoscopy was performed before treatment began and at 29 days. Lesions were scored from grade 0 to 6. Data were analyzed using ANOVA and paired t-tests (P < 0.05). None of the dogs presented adverse clinical effects. There were no significant changes in CBC, biochemical profiles within groups, or differences between groups. Pretreatment mean SD bleeding time (LG, 70.7 +/- 32.1 sec; FG, 75.8 +/- 38.1 sec) and platelet aggregation (LG, 86.4 +/- 10.2%; FG, 85.6 +/- 9.2%) were not significantly different from readings at 29 days (LG, 95.2 +/- 25 sec; FG, 91.7 +/- 24 sec and LG, 73.2 +/- 15.1%; FG, 84 +/- 10.3%) nor the groups were different. None of the dogs had positive fecal occult blood tests, and endoscopic lesion scores were grade 0 both before treatment and at 29 days. Administration of firocoxib did not cause any adverse effects on GI, or hematological or serum biochemical variables and appears to have been well tolerated by dogs.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Objective: To assess the bioequivalence of 2 tablet formulations of phentolamine (Regitine phentolamine 40 mg tablet formulation by Novartis, Brazil, as test formulation, and Vasomax, phentolamine 40 mg tablet formulation by Schering Plough S.A., Brazil, as reference formulation). Methods: A single 40 mg oral dose of each formulation was administered to 36 male healthy volunteers. The study was conducted after screening, using an open, randomized, 2-period crossover design, a 7-day interval between doses, and wash-out period of at least 4 weeks. Plasma samples for determination of phentolarnine were obtained predose and at intervals over 720 min postdose. Plasma concentrations were quantified by reversed-phase liquid chromatography coupled to tandem mass spectrometry (LC-MS-MS) with positive ion electrospray ionization using multiple reactions monitoring (MRM) method. Precision of the method was evaluated using calibration curves and plasma quality control samples. The subjects were monitored throughout the study. Systolic and diastolic blood pressure and pulse rate measurement were taken predose and at intervals up to 720 min. Tolerance of both products was good. No serious adverse reactions were reported. The pharmacokinetic parameters calculated for both compounds included: AUC((0-720 min)), AUC((0-infinity)), C-max,C- C-max/AUC((0-720 min),) t(max), t(1/2) and k(c). Results: the maximum concentrations reached (Cmax) were compared. Regitine 40 mg formulation C-max geometric mean ratio was 108.29% (90% Cl = 98.58 - 118.96) of Vasomax 40 mg formulation. The areas under the curve (AUC((0-720 min))) were compared. Regitine 40 formulation (AUC((0-720 min)) geometric mean ratio was 102.33% (90% Cl = 97.21 - 107.72) of Vasomax 40 mg formulation. Conclusion: Since the 90% Cl for both Cmax and AUC ratio where inside the 80 to 125% interval proposed by the Food and Drug Administration, it is concluded that Regitine 40 mg tablet is bioequivalent to Vasomax for the rate and extent of absorption.