995 resultados para MAGNETIC FLUID
Resumo:
This study is aimed at evaluating the potential to detect human immunodeficiency virus (HIV) in amniotic fluid (AF) collected at delivery from 40 HIV-positive pregnant women. Thirty patients had a plasma viral load (VL) below 1,000 copies/mL at delivery. VL was positive in three AF samples. No significant association was found between the HIV-1 RNA in AF and the maternal plasma samples. There was no HIV vertical transmission detected.
Resumo:
To evaluate commercial Lionex TB together with four antigens of Mycobacterium tuberculosis (MPT-64, MT10.3, 16 kDa and 38 kDa) for IgG and IgA cerebrospinal fluid (CSF) detection in the diagnosis of tuberculosis meningitis (TBM) with CSF negative acid-fast bacilli staining, 19 cases of TBM, 64 cases of other infectious meningoencephalitis and 73 cases of other neurological disorders were tested by enzyme linked immunosorbent assay. IgA-MPT-64 and IgG Lionex showed the highest sensitivities, specificities, positive predictive value and negative predictive value (63.2%, 47.4%; 95%, 93.7%; 40%, 98% and 28.4%, 97.1%, respectively). However, while grey zone was 12.7% and 6%, respectively, lowering sensitivity but maintains high specificity (> 95%). High protein concentration in CSF was associated with antibody positivity CSF/HIV+ which did not influence the sensitivity of both tests. To our knowledge, this is the first description of IgA-MPT-64 and IgG Lionex antibodies in CSF-TBM and, although there is good specificity, adjustments are needed based on antigen composition to enhance sensitivity.
Resumo:
Due to SNR constraints, current "bright-blood" 3D coronary MRA approaches still suffer from limited spatial resolution when compared to conventional x-ray coronary angiography. Recent 2D fast spin-echo black-blood techniques maximize signal for coronary MRA at no loss in image spatial resolution. This suggests that the extension of black-blood coronary MRA with a 3D imaging technique would allow for a further signal increase, which may be traded for an improved spatial resolution. Therefore, a dual-inversion 3D fast spin-echo imaging sequence and real-time navigator technology were combined for high-resolution free-breathing black-blood coronary MRA. In-plane image resolution below 400 microm was obtained. Magn Reson Med 45:206-211, 2001.
Resumo:
BACKGROUND: Long-term therapy with natalizumab increases the risk of progressive multifocal leukoencephalopathy (PML). OBJECTIVES: We present a patient study through therapy, the diagnosis of PML (after 29 infusions), plasma exchange (PE) and development of immune reconstitution inflammatory syndrome (IRIS). METHODS: Routine diagnostics, magnetic resonance imaging (MRI), immunological status (flow cytometry, T-cell migration assays and T-cell repertoire analysis), and brain biopsy with immunohistological analysis. RESULTS: CD49d decreased after 12 months of treatment. At PML diagnosis, CD49d expression and migratory capacity of T cells was low and peripheral T-cell receptor (TCR) complexity showed severe perturbations. The distribution of peripheral monocytes changed from CCR5+ to CCR7+. After PE some changes reverted: CD49d increased and overshot earliest levels, migratory capacities of T cells recovered and peripheral TCR complexity increased. With no clinical, routine laboratory or cerebrospinal fluid (CSF) changes, MRI 2 months after PE demonstrated progressive lesion development. Brain histopathology confirmed the presence of infiltrates indicative of IRIS without clinical signs, immunologically accompanied by CCR7/CCR5 recovery of peripheral monocytes. CONCLUSION: Natalizumab-associated immunological changes accompanying PML were reversible after PE; IRIS can occur very late, remain asymptomatic and be elusive to CSF analysis. Our study may provide insights into the changes under treatment with natalizumab associated with JC virus control.
Resumo:
Iodine deficiency is an important clinical and public health problem. Its prevention begins with an adequate intake of iodine during pregnancy. International agencies recommend at least 200 microg iodine per d for pregnant women. We assessed whether iodine concentrations in the amniotic fluid of healthy pregnant women are independent of iodine intake. This cross-sectional, non-interventional study included 365 consecutive women who underwent amniocentesis to determine the fetal karyotype. The amniocentesis was performed with abdominal antisepsis using chlorhexidine. The iodine concentration was measured in urine and amniotic fluid. The study variables were the intake of iodized salt and multivitamin supplements or the prescription of a KI supplement. The mean level of urinary iodine was 139.0 (SD 94.5) microg/l and of amniotic fluid 15.81 (SD 7.09) microg/l. The women who consumed iodized salt and those who took a KI supplement had significantly higher levels of urinary iodine than those who did not (P = 0.01 and P = 0.004, respectively). The urinary iodine levels were not significantly different in the women who took a multivitamin supplement compared with those who did not take this supplement, independently of iodine concentration or multivitamin supplement. The concentrations of iodine in the amniotic fluid were similar, independent of the dietary iodine intake. Urine and amniotic fluid iodine concentrations were weakly correlated, although the amniotic fluid values were no higher in those women taking a KI supplement. KI prescription at recommended doses increases the iodine levels in the mother without influencing the iodine levels in the amniotic fluid.
Resumo:
RESUME Les améliorations méthodologiques des dernières décennies ont permis une meilleure compréhension de la motilité gastro-intestinale. Il manque toutefois une méthode qui permette de suivre la progression du chyme le long du tube gastro-intestinal. Pour permettre l'étude de la motilité de tout le tractus digestif humain, une nouvelle technique, peu invasive, a été élaborée au Département de Physiologie, en collaboration avec l'EPFL. Appelée "Magnet Tracking", la technique est basée sur la détection du champ magnétique généré par des matériaux ferromagnétiques avalés. A cet usage, une pilule magnétique, une matrice de capteurs et un logiciel ont été développés. L'objet de ce travail est de démontrer la faisabilité d'un examen de la motilité gastro-intestinale chez l'Homme par cette méthode. L'aimant est un cylindre (ø 6x7 mm, 0.2 cm3) protégé par une gaine de silicone. Le système de mesure est constitué d'une matrice de 4x4 capteurs et d'un ordinateur portable. Les capteurs fonctionnent sur l'effet Hall. Grâce à l'interface informatique, l'évolution de la position de l'aimant est suivie en temps réel à travers tout le tractus digestif. Sa position est exprimée en fonction du temps ou reproduite en 3-D sous forme d'une trajectoire. Différents programmes ont été crées pour analyser la dynamique des mouvements de l'aimant et caractériser la motilité digestive. Dix jeunes volontaires en bonne santé ont participé à l'étude. L'aimant a été avalé après une nuit de jeûne et son séjour intra digestif suivi pendant 2 jours consécutifs. Le temps moyen de mesure était de 34 heures. Chaque sujet a été examiné une fois sauf un qui a répété sept fois l'expérience. Les sujets restaient en décubitus dorsal, tranquilles et pouvaient interrompre la mesure s'ils le désiraient. Ils sont restés à jeûne le premier jour. L'évacuation de l'aimant a été contrôlée chez tous les sujets. Tous les sujets ont bien supporté l'examen. Le marqueur a pu être détecté de l'oesophage au rectum. La trajectoire ainsi constituée représente une conformation de l'anatomie digestive : une bonne superposition de celle-ci à l'anatomie est obtenue à partir des images de radiologie conventionnelle (CT-scan, lavement à la gastrografine). Les mouvements de l'aimant ont été caractérisés selon leur périodicité, leur amplitude ou leur vitesse pour chaque segment du tractus digestif. Ces informations physiologiques sont bien corrélées à celles obtenues par des méthodes établies d'étude de la motilité gastro-intestinale. Ce travail démontre la faisabilité d'un examen de la motilité gastro-intestinal chez l'Homme par la méthode de Magnet Tracking. La technique fournit les données anatomiques et permet d'analyser en temps réel la dynamique des mouvements du tube digestif. Cette méthode peu invasive ouvre d'intéressantes perspectives pour l'étude de motilité dans des conditions physiologiques et pathologiques. Des expériences visant à valider cette approche en tant que méthode clinique sont en voie de réalisation dans plusieurs centres en Suisse et à l'étranger. SUMMARY Methodological improvements realised over the last decades have permitted a better understanding of gastrointestinal motility. Nevertheless, a method allowing a continuous following of lumina' contents is still lacking. In order to study the human digestive tract motility, a new minimally invasive technique was developed at the Department of Physiology in collaboration with Swiss Federal Institute of Technology. The method is based on the detection of magnetic field generated by swallowed ferromagnetic materials. The aim of our work was to demonstrate the feasibility of this new approach to study the human gastrointestinal motility. The magnet used was a cylinder (ø6x7mm, 0.2 cm3) coated with silicon. The magnet tracking system consisted of a 4x4 matrix of sensors based on the Hall effect Signals from the sensors were digitised and sent to a laptop computer for processing and storage. Specific software was conceived to analyse in real time the progression of the magnet through the gastrointestinal tube. Ten young and healthy volunteers were enrolled in the study. After a fasting period of 12 hours, they swallowed the magnet. The pill was then tracked for two consecutive days for 34 hours on average. Each subject was studied once except one who was studied seven times. Every subject laid on his back for the entire experiment but could interrupt it at anytime. Evacuation of the magnet was controlled in all subjects. The examination was well tolerated. The pill could be followed from the esophagus to the rectum. The trajectory of the magnet represented a "mould" of the anatomy of the digestive tube: a good superimposition with radiological anatomy (gastrografin contrast and CT) was obtained. Movements of the magnet were characterized by periodicity, velocity, and amplitude of displacements for every segment of the digestive tract. The physiological information corresponded well to data from current methods of studying gastrointestinal motility. This work demonstrates the feasibility of the new approach in studies of human gastrointestinal motility. The technique allows to correlate in real time the dynamics of digestive movements with the anatomical data. This minimally invasive method is ready for studies of human gastrointestinal motility under physiological as well as pathological conditions. Studies aiming at validation of this new approach as a clinically relevant tool are being realised in several centres in Switzerland and abroad. Abstract: A new minimally invasive technique allowing for anatomical mapping and motility studies along the entire human digestive system is presented. The technique is based on continuous tracking of a small magnet progressing through the digestive tract. The coordinates of the magnet are calculated from signals recorded by 16 magnetic field sensors located over the abdomen. The magnet position, orientation and trajectory are displayed in real time. Ten young healthy volunteers were followed during 34 h. The technique was well tolerated and no complication was encountered, The information obtained was 3-D con-figuration of the digestive tract and dynamics of the magnet displacement (velocity, transit time, length estimation, rhythms). In the same individual, repea-ted examination gave very reproducible results. The anatomical and physiological information obtained corresponded well to data from current methods and imaging. This simple, minimally invasive technique permits examination of the entire digestive tract and is suitable for both research and clinical studies. In combination with other methods, it may represent a useful tool for studies of Cl motility with respect to normal and pathological conditions.
Resumo:
The effects of dark-induced stress on the evolution of the soluble metabolites present in senescent soybean (Glycine max L.) nodules were analysed in vitro using (13)C- and (31)P-NMR spectroscopy. Sucrose and trehalose were the predominant soluble storage carbons. During dark-induced stress, a decline in sugars and some key glycolytic metabolites was observed. Whereas 84% of the sucrose disappeared, only one-half of the trehalose was utilised. This decline coincides with the depletion of Gln, Asn, Ala and with an accumulation of ureides, which reflect a huge reduction of the N(2) fixation. Concomitantly, phosphodiesters and compounds like P-choline, a good marker of membrane phospholipids hydrolysis and cell autophagy, accumulated in the nodules. An autophagic process was confirmed by the decrease in cell fatty acid content. In addition, a slight increase in unsaturated fatty acids (oleic and linoleic acids) was observed, probably as a response to peroxidation reactions. Electron microscopy analysis revealed that, despite membranes dismantling, most of the bacteroids seem to be structurally intact. Taken together, our results show that the carbohydrate starvation induced in soybean by dark stress triggers a profound metabolic and structural rearrangement in the infected cells of soybean nodule which is representative of symbiotic cessation.
Resumo:
BACKGROUND: Diffusion-weighted magnetic resonance imaging (MRI) is increasingly being used for assessing the treatment succes in oncology, but the real clinical value needs to evaluated by comparison with other, already established, metabolic imaging techniques. PURPOSE: To prospectively evaluate the clinical potential of diffusion-weighted MRI with apparent diffusion coefficient (ADC) mapping for gastrointestinal stromal tumor (GIST) response to targeted therapy compared with 18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT). MATERIAL AND METHODS: Eight patients (mean age, 56 ± 11 years) known to have metastatic GIST underwent 18F-FDG PET/CT and MRI (T1Gd, DWI [b = 50,300,600], ADC mapping) simultaneously, before and after change in targeted therapy. MR and PET/CT examinations were first analyzed blindly. Second, PET/CT images were co-registered with T1Gd-MR images for lesion detection. Only 18F-FDG avid lesions were considered. Maximum standardized uptake value (SUVmax) and the corresponding minimum ADCmin were measured for the six largest lesions per patient, if any, on baseline and follow-up examinations. The relationship between changes in SUVmax and ADCmin was analyzed (Spearman's correlation). RESULTS: Twenty-four metastases (12 hepatic, 12 extra-hepatic) were compared on PET/CT and MR images. SUVmax decreased from 7.7 ± 8.1 g/mL to 5.5 ± 5.4 g/mL (P = 0.20), while ADCmin increased from 1.2 ± 0.3 × 10(-3)mm(2)/s to 1.5 ± 0.3 × 10(-3)mm(2)/s (P = 0.0002). There was a significant association between changes in SUVmax and ADCmin (rho = - 0.62, P = 0.0014), but not between changes in lesions size (P = 0.40). CONCLUSION: Changes in ADCmin correlated with the response of 18F-FDG avid GIST to targeted therapy. Thus, diffusion-weighted MRI may represent a radiation-free alternative for follow-up treatment for metastatic GIST patients.
Resumo:
RATIONALE AND OBJECTIVES: Recent developments of magnetic resonance imaging enabled free-breathing coronary MRA (cMRA) using steady-state-free-precession (SSFP) for endogenous contrast. The purpose of this study was a systematic comparison of SSFP cMRA with standard T2-prepared gradient-echo and spiral cMRA. METHODS: Navigator-gated free-breathing T2-prepared SSFP-, T2-prepared gradient-echo- and T2-prepared spiral cMRA was performed in 18 healthy swine (45-68 kg body-weight). Image quality was investigated subjectively and signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and vessel sharpness were compared. RESULTS: SSFP cMRA allowed for high quality cMRA during free breathing with substantial improvements in SNR, CNR and vessel sharpness when compared with standard T2-prepared gradient-echo imaging. Spiral imaging demonstrated the highest SNR while image quality score and vessel definition was best for SSFP imaging. CONCLUSION: Navigator-gated free-breathing T2-prepared SSFP cMRA is a promising new imaging approach for high signal and high contrast imaging of the coronary arteries with improved vessel border definition.
Resumo:
In the last decade, evidence has emerged indicating that the growth of a vast majority of tumors including gliomas is sustained by a subpopulation of cancer cells with stem cell properties called cancer initiating cells. These cells are able to initiate and propagate tumors and constitute only a fraction of all tumor cells. In the present study, we showed that intracerebral injection of cultured glioma-initiating cells into nude mice produced fast growing tumors showing necrosis and gadolinium enhancement in MR images, whereas gliomas produced by injecting freshly purified glioma-initiating cells grew slowly and showed no necrosis and very little gadolinium enhancement. Using proton localized spectroscopy at 14.1 Tesla, decreasing trends of N-acetylaspartate, glutamate and glucose concentrations and an increasing trend of glycine concentration were observed near the injection site after injecting cultured glioma-initiating cells. In contrast to the spectra of tumors grown from fresh cells, those from cultured cells showed intense peaks of lipids, increased absolute concentrations of glycine and choline-containing compounds, and decreased concentrations of glutamine, taurine and total creatine, when compared with a contralateral non-tumor-bearing brain tissue. A decrease in concentrations of N-acetylaspartate and γ-aminobutyrate was found in both tumor phenotypes after solid tumor formation. Further investigation is needed to determine the cause of the dissimilarities between the tumors grown from cultured glioma-initiating cells and those from freshly purified glioma-initiating cells, both derived from human glioblastomas.
Resumo:
Background :¦In addition to opportunistic infections of the central nervous system (CNS), which are due to immunosuppression related to HIV, the latter virus, itself, can cause neuropathological abnormalities which are located mainly in the basal ganglia and are characterized by microglial giant cells, reactive astrocytosis and perivascular monocytes. This HIV encephalopathy is characterized, clinically, by psycho-motor slowing, memory loss, difficulties in complex tasks requiring executive functions, as well as motor disorders .These cognitive deficits are grouped under the acronym of HIV-associated neurocognitive disorders (HAND). In fact, HANDs are subdivided in three groups in accordance with the severity of the cognitive impairment: Asymptomatic Neurocognitive Impairment (ANI), Mild/moderate Neurocognitive Disorders (MND) and HIV Associated Dementia (HAD).¦While the incidence of HAD has significantly decreased in the era of combined antiretrobiral therapy (cART), the prevalence of milder forms of HIV-associated neurocognitive disorders HAND seem to have increased. There are many potential reasons to explain this state of facts.¦An important question is to understand how soon the brain may be affected by HIV. Since performing a biopsy in these patients is not an issue, the study of the CSF represents the best available way to look at putative biomarkers of inflammation/neurodegeneration in the CNS. Here, we wanted to examined the putative usefulness of different biomarkers as early indicators of anti-retroviral failure at the level of the CNS. We chose to study the CSF levels of:¦Amyloid-β 1-42 (Aβ42), Tau total (tTau), phosphorylated Tau (pTau), Neopterin and S100-β.¦Indeed, these molecules are representative biomarkers of the major cells of the CNS, i.e. neurons,¦macrophages/microglia and astrocytes.¦To examine how sensitive were these CSF biomarkers to indicate CNS insults caused by HIV, we proposed to take advantage of the MOST (Monotherapy Switzerland/Thailand study) study, recently published in AIDS. Thus, we collaborated with Prof. Pietro Vernazza in St-Gall. In MOST study, monotherapy (MT) consisting in ritonavir-boosted lopinavir (LPV/r) was compared to continuous conventional antiretroviral therapy including several molecules, hereafter referred as CT¦Methods :We tested 61 cerebrospinal fluid (CSF) samples from 52 patients enrolled in MOST, including 34 CSF samples of CT and 27 of MT (mean duration on MT: 47+20 weeks) in patients who maintained full VL suppression in blood (<50cps/ml). Using enzyme-linked immunosorbent assay (ELISA), we determined the CSF concentration of S100-beta (astrocytosis), neopterin (microglia, inflammation), total Tau (tTau), phosphorylated Tau (pTau), and amyloid-beta 1-42 (Abeta), the latter three markers indicating neuronal damages. The CSF samples of 37 HIV-negative patients with Alzheimer dementia (AD) served as controls. Results are expressed in pg/ml and reported as median ± interquartile range. Mann Whitney-U test was used to compare the results of a given biomarker between two groups and the Fisher test to compare frequencies.¦Results: We found a higher concentration of S100-beta (570±1132) and neopterin (2.5±2.9) in the CSF of MT versus CT (0±532, p=0.002 and 1.2±2.5, p=0.058, respectively). A cutoff of 940 pg/ml for S100-beta allowed to discriminate MT (11 above versus 16 below) from CT (1 vs 33, p=0.0003). At a lesser extent, a cutoff of 11 pg/ml for neopterin separated MT (4 above versus 23) from CT (0 vs 34, p=0.034) (Figure).¦In AD, tTau was higher (270±414) and Abeta lower (234±328) than in CT (150±153, p=0.0078, and 466±489, p=0.007, respectively). Such as for CT, Abeta was lower in AD than in MT (390±412, p=0.01). However, contrasting with CT, the levels of tTau were not different between AD and MT (199±177, p=0.11). S100b (173±214; p=0.0006) and neopterin (1.1±0.9; p=0.0014) were lower in AD than MT.¦Conclusions: Despite full VL-suppression in blood, HIV monotherapy is sufficient to trigger inflammation and, especially, astrocytosis. CSF markers of patients on CT have the same profile as reported for healthy subjects, suggesting that CT permits a good control of HIV in the brain. Finally, the levels of tTau, which are relatively similar between AD and MT patients, suggest that neurons are damaged during monotherapy.
Resumo:
Urea nitrogen, creatinine, and uric acid are relatively stable in postmortem serum and may, therefore, be used for diagnostic purposes when chronic kidney disease and end-stage renal failure are investigated as causes of death. Nevertheless, uncertainties remain in defining the best alternative to postmortem serum for the identification and assessment of significantly decreased kidney function. In this study, we investigated urea nitrogen, creatinine, and uric acid levels in postmortem serum, pericardial fluid, and vitreous humor in a series of medico-legal cases (500 autopsies) with various causes of death. No postmortem interval-related differences were observed in any of the investigated fluids for any analyzed parameter, confirming the biochemical stability of all compounds after death. Data analysis failed to reveal statistically significant differences between postmortem serum and pericardial fluid urea nitrogen, creatinine, and uric acid concentrations. Conversely, statistically significant differences were observed in all analyzed biomarkers between postmortem serum and vitreous humor levels, with lower concentrations of all markers measured in vitreous. The results of this study suggest that, in order to estimate as accurately as possible blood analyte concentrations at the time of death, pericardial fluid should be preferred to vitreous humor.
Resumo:
Methods are presented to map complex fiber architectures in tissues by imaging the 3D spectra of tissue water diffusion with MR. First, theoretical considerations show why and under what conditions diffusion contrast is positive. Using this result, spin displacement spectra that are conventionally phase-encoded can be accurately reconstructed by a Fourier transform of the measured signal's modulus. Second, studies of in vitro and in vivo samples demonstrate correspondence between the orientational maxima of the diffusion spectrum and those of the fiber orientation density at each location. In specimens with complex muscular tissue, such as the tongue, diffusion spectrum images show characteristic local heterogeneities of fiber architectures, including angular dispersion and intersection. Cerebral diffusion spectra acquired in normal human subjects resolve known white matter tracts and tract intersections. Finally, the relation between the presented model-free imaging technique and other available diffusion MRI schemes is discussed.