961 resultados para Line voltage
Resumo:
A portable microcontrolled system is proposed to monitor conductivity, temperature and pH in on-line, in situ and remote way from a water reservoir faraway 200 m. The system comprises two modules: one for data reception (located in laboratory) and another for data acquisition/transmission (located near water reservoir). It uses a microcontroller and a transceiver to remote data transmission/reception by radio frequency. Variations of water parameters were simultaneously monitored without interruption during a period of ten hours with a relative error about 4.0 %. The developed system showed simple, stable, accurate, robust and low-cost to determine parameters of water in field.
Resumo:
Kymenlaakson Sähköverkko Oy:n 20/0,4 kV tekniikalla toteutettu sähkönjakeluverkko on monin paikoin saavuttamassa pitoaikansa loppua. Sähkönjakeluverkko sijaitsee pääasiassa haja-asutusalueilla ja on pääosin avojohtotekniikalla rakennettua. Haja-asutusalueilla 20 kV sähköverkko sisältää paljon lyhyitä 1–5 km pituisia johtohaaroja. Tässä diplomityössä selvitettiin 20/1/0,4 kV sähkönjakelujärjestelmän käyttömahdollisuuksia Kymenlaakson Sähköverkko Oy:n sähkönjakeluverkossa. Työssä vertailtiin erilaisilla verkostoratkaisuilla saatavia elinkaarikustannuksia perusparannus- ja uudisrakennuskohteissa. Tutkimuksen perusteella Kymenlaakson Sähköverkko Oy:n sähkönjakeluverkossa on potentiaalia 1000 V jakelujännitteen käytölle. Työssä perehdyttiin myös 1000 V verkostokomponenttien merkitsemiseen ja verkkoyhtiön tekemiin 1000 V verkon tarkastuksiin.
Resumo:
Työn tavoitteena oli laatia Mäntsälän Sähkö Oy:n jakeluverkon kehittämissuunnitelma vuodelle 2020. Työn laadinta aloitettiin selvittämällä verkon nykytila ja käyttövarmuus korvaustilanteissa. Tämän jälkeen työssä paikannettiin alueet, joissa korvattavuuden parantaminen tai kuormituksien kasvaminen tulevaisuudessa edellyttää mittavia investointeja jakeluverkon käyttövarmuuden takaamiseksi. Työssä tarkastellaan yksityiskohtaisemmin Järvelän alueen käyttövarmuuden kehittämistä ja Hennan alueen kuormituksen kasvuun varautumista. Järvelän alueen käyttövarmuuden parantaminen edellyttää joko uutta sähköasemainvestointia tai 110 kV johdon rakentamista. Hennan alueen kuormituksen kasvu edellyttää, alueen kuormituksista riippuen, joko yhtä tai kahta uutta sähköasemainvestointia.
Resumo:
The effects of pulp processing on softwood fiber properties strongly influence the properties of wet and dry paper webs. Pulp strength delivery studies have provided observations that much of the strength potential of long fibered pulp is lost during brown stock fiber line operations where the pulp is merely washed and transferred to the subsequent processing stages. The objective of this work was to study the intrinsic mechanisms which maycause fiber damage in the different unit operations of modern softwood brown stock processing. The work was conducted by studying the effects of industrial machinery on pulp properties with some actions of unit operations simulated in laboratory scale devices under controlled conditions. An optical imaging system was created and used to study the orientation of fibers in the internal flows during pulp fluidization in mixers and the passage of fibers through the screen openings during screening. The qualitative changes in fibers were evaluated with existing and standardized techniques. The results showed that each process stage has its characteristic effects on fiber properties: Pulp washing and mat formation in displacement washers introduced fiber deformations especially if the fibers entering the stage were intact, but it did not decrease the pulp strength properties. However, storage chests and pulp transfer after displacement washers contributed to strength deterioration. Pulp screening proved to be quite gentle, having the potential of slightly evening out fiber deformations from very deformed pulps and vice versa inflicting a marginal increase in the deformation indices if the fibers were previously intact. Pulp mixing in fluidizing industrial mixers did not have detrimental effects on pulp strength and had the potential of slightly evening out the deformations, provided that the intensity of fluidization was high enough to allow fiber orientation with the flow and that the time of mixing was short. The chemical and mechanical actions of oxygen delignification had two distinct effects on pulp properties: chemical treatment clearly reduced pulp strength with and without mechanical treatment, and the mechanical actions of process machinery introduced more conformability to pulp fibers, but did not clearly contribute to a further decrease in pulp strength. The chemical composition of fibers entering the oxygen stage was also found to affect the susceptibility of fibers to damage during oxygen delignification. Fibers with the smallest content of xylan were found to be more prone to irreversibledeformations accompanied with a lower tensile strength of the pulp. Fibers poor in glucomannan exhibited a lower fiber strength while wet after oxygen delignification as compared to the reference pulp. Pulps with the smallest lignin content on the other hand exhibited improved strength properties as compared to the references.
Resumo:
The maximum realizable power throughput of power electronic converters may be limited or constrained by technical or economical considerations. One solution to this problemis to connect several power converter units in parallel. The parallel connection can be used to increase the current carrying capacity of the overall system beyond the ratings of individual power converter units. Thus, it is possible to use several lower-power converter units, produced in large quantities, as building blocks to construct high-power converters in a modular manner. High-power converters realized by using parallel connection are needed for example in multimegawatt wind power generation systems. Parallel connection of power converter units is also required in emerging applications such as photovoltaic and fuel cell power conversion. The parallel operation of power converter units is not, however, problem free. This is because parallel-operating units are subject to overcurrent stresses, which are caused by unequal load current sharing or currents that flow between the units. Commonly, the term ’circulatingcurrent’ is used to describe both the unequal load current sharing and the currents flowing between the units. Circulating currents, again, are caused by component tolerances and asynchronous operation of the parallel units. Parallel-operating units are also subject to stresses caused by unequal thermal stress distribution. Both of these problemscan, nevertheless, be handled with a proper circulating current control. To design an effective circulating current control system, we need information about circulating current dynamics. The dynamics of the circulating currents can be investigated by developing appropriate mathematical models. In this dissertation, circulating current models aredeveloped for two different types of parallel two-level three-phase inverter configurations. Themodels, which are developed for an arbitrary number of parallel units, provide a framework for analyzing circulating current generation mechanisms and developing circulating current control systems. In addition to developing circulating current models, modulation of parallel inverters is considered. It is illustrated that depending on the parallel inverter configuration and the modulation method applied, common-mode circulating currents may be excited as a consequence of the differential-mode circulating current control. To prevent the common-mode circulating currents that are caused by the modulation, a dual modulator method is introduced. The dual modulator basically consists of two independently operating modulators, the outputs of which eventually constitute the switching commands of the inverter. The two independently operating modulators are referred to as primary and secondary modulators. In its intended usage, the same voltage vector is fed to the primary modulators of each parallel unit, and the inputs of the secondary modulators are obtained from the circulating current controllers. To ensure that voltage commands obtained from the circulating current controllers are realizable, it must be guaranteed that the inverter is not driven into saturation by the primary modulator. The inverter saturation can be prevented by limiting the inputs of the primary and secondary modulators. Because of this, also a limitation algorithm is proposed. The operation of both the proposed dual modulator and the limitation algorithm is verified experimentally.
Resumo:
Yleisesti sähkönjakelussa käytettyä vaihtosähköä ollaan korvaamassa tasasähköllä pienjänniteverkoissa. Vaihtojännitteeseen verrattuna tasajännitteen käyttö mahdollistaa korkeampien jännitetasojen käytön ja paremman sähkönlaadun ja sitä kautta paremman käyttövarmuuden. Sähköverkossa käytettävien muuntajien ja suuntaajien osalta tarvitaan uudenlaisia rakenteita ja kehitystä, että tasajännitejakelun käyttöönotto olisi mahdollista. Oikeiden ratkaisujen löytämiseksi on tehty jo paljon tutkimusta, mutta valmiita järjestelmiä ei vielä ole laajemmin otettu käyttöön. Tasajänniteverkot tarvitsevat myös ohjauksen, säädön ja valvonnan takia tiedonsiirto-ominaisuuksia. Tietoa on mahdollista siirtää samassa kaapelissa, jota käytetään myös sähkön siirtoon. Haasteita asettavat mm. kaapeliin kytketyminen ja tiedonsiirtokanavassa esiintyvät häiriöt. Työssä muodostetaan malli tiedonsiirtokanavasta, jonka avulla voidaan mallintaa verkon käyttäytymistä eri taajuuksilla sekä simuloida sähköverkkoon muodostettavia tiedonsiirtokanavia.
Resumo:
The main objective for this study was to explore certain organization’s product line rebranding process and its impact on product line’s perceived image. The case company is a global paper, packaging and forest products company, business segment paper board. The audience explored is one of the company’s major customers, merchant in Germany. The research was performed as a descriptive case study with a purpose to provide longitudinal insight into the product line image and its eventual alteration as a result of the case company’s rebranding process. Mainly qualitative methods were used for conducting the research. The data for the empirical part was collected with a web-based survey at two different points of time; before the rebranded products entered the market and after they had been available approximately six months. The results of this study reveal that the case company has performed well in its attempt to improve product line’s brand image through rebranding. It was found that between the two brand image measurements the product brand image seems to have improved in all of the areas which according to theoretical framework of this study contribute to formation of brand image; brand associations, marketing communications and interpersonal relationships, not forgetting the original platform that initiated the change; technical quality modifications. In other words it may be concluded that as technical quality was brought to a new level, also assessments about the brand image improved respectively.
Resumo:
N-methylpyrrolidone is a powerful solvent for variety of chemical processes due to its vast chemical properties. It has been used in manufacturing processes of polymers, detergents, pharmaceuticals rubber and many more chemical substances. However, it creates large amount of residue in some of these processes which has to be dealt with. Many well known methods such as BASF in rubber producing units have tried to regenerate the solvent at the end of each run, however, there is still discarding of large amount of residue containing NMP, which over time, could cause environmental concerns. In this study, we have tried to optimize regeneration of the NMP extraction from butadiene production. It is shown that at higher temperatures NMP is separated from the residue with close to 90% efficiency, and the solvent residue proved to be the most effective with a 6: 1 ratio.
Resumo:
In recent years, the network vulnerability to natural hazards has been noticed. Moreover, operating on the limits of the network transmission capabilities have resulted in major outages during the past decade. One of the reasons for operating on these limits is that the network has become outdated. Therefore, new technical solutions are studied that could provide more reliable and more energy efficient power distributionand also a better profitability for the network owner. It is the development and price of power electronics that have made the DC distribution an attractive alternative again. In this doctoral thesis, one type of a low-voltage DC distribution system is investigated. Morespecifically, it is studied which current technological solutions, used at the customer-end, could provide better power quality for the customer when compared with the current system. To study the effect of a DC network on the customer-end power quality, a bipolar DC network model is derived. The model can also be used to identify the supply parameters when the V/kW ratio is approximately known. Although the model provides knowledge of the average behavior, it is shown that the instantaneous DC voltage ripple should be limited. The guidelines to choose an appropriate capacitance value for the capacitor located at the input DC terminals of the customer-end are given. Also the structure of the customer-end is considered. A comparison between the most common solutions is made based on their cost, energy efficiency, and reliability. In the comparison, special attention is paid to the passive filtering solutions since the filter is considered a crucial element when the lifetime expenses are determined. It is found out that the filter topology most commonly used today, namely the LC filter, does not provide economical advantage over the hybrid filter structure. Finally, some of the typical control system solutions are introduced and their shortcomings are presented. As a solution to the customer-end voltage regulation problem, an observer-based control scheme is proposed. It is shown how different control system structures affect the performance. The performance meeting the requirements is achieved by using only one output measurement, when operating in a rigid network. Similar performance can be achieved in a weak grid by DC voltage measurement. An additional improvement can be achieved when an adaptive gain scheduling-based control is introduced. As a conclusion, the final power quality is determined by a sum of various factors, and the thesis provides the guidelines for designing the system that improves the power quality experienced by the customer.
Resumo:
Background: In Finland, breast cancer (BC) is the most common cancer among women, and prostate cancer (PC) that among men. At the metastatic stage both cancers remain essentially incurable. The goals of therapy include palliation of symptoms, improvement or maintenance of quality of life (QoL), delay of disease progression, and prolongation of survival. Balancing between efficacy and toxicity is the major challenge. With increasing costs of new treatments, appropriate use of resources is paramount. When new treatment regimes are introduced into clinical practice a comprehensive assessment of clinical benefit, adverse effects and cost is necessary. Both BC and PC show a predilection to metastasize to bone. Bone metastases cause significant morbidity impairing the patients´ QoL. Diagnosis of bone metastases relies mainly on radiological methods, which however lack optimal sensitivity and specificity. New tools are needed for detection and follow-up of bone metastases. Aims: Anthracyclines and taxanes are effective chemotherapeutic agents in the treatment of metastatic breast cancer (MBC) with different mechanisms of action. Therefore, evaluation of the combination of anthracyclines with taxanes was a justifiable approach in the treatment of MBC patients. We assessed the efficacy, toxicity, cost of treatment and QoL of BC patients treated with first-line chemotherapy for metastatic disease with the combination epirubicin and docetaxel. We also evaluated the diagnostic potential of tartrate-resistant acid phosphatase 5b (TRACP 5b) and carboxyterminal telopeptides of type I collagen (ICTP) in the diagnosis of bone metastases in BC and TRACP 5b in PC patients. Results: The combination of epirubicin and docetaxel was effective in this phase II study, but required individual dose adjustment to avoid neutropenic infections, and the use of growth factors to maintain a feasible dose level. The response rate was 54 % (95 % CI 37-71) and the median overall survival (OS) was 26 months. Of the patients, 87 % were treated for infections. The treatment of adverse events required additional use of health resources mainly due to neutropenic infections, thereby raising direct treatment costs by 20 %. Despite adverse events, the global QoL was not significantly compromised during the treatment. Clinically evident acute cardiac toxicity was not observed. The combination of serum TRACP 5b and ICTP was at least equally sensitive and specific in detection of of bone metastases as commonly used total alkaline phosphatise (tALP) in BC patients. In contrast, TRACP 5b was less specific and sensitive than tALP as a marker of skeletal changes in PC patients. Conclusions: Treatment with epirubicin and docetaxel showed high efficacy in first-line chemotherapy of MBC. The relatively high incidence of neutropenic infections requiring hospitalization increased the treatment costs. Despite adverse events, the global QoL of the patients was not significantly compromised. The combination of TRACP 5b and ICTP showed similar activity as tALP in detecting bone metastases in MBC. In contrast, TRACP 5b was less specific and sensitive than tALP as a marker of skeletal changes in PC.
Resumo:
Nowadays power drives are the essential part almost of all technological processes. Improvement of efficiency and reduction of losses require development of semiconductor switches. It has a particular meaning for the constantly growing market of renewable sources, especially for wind turbines, which demand more powerful semiconductor devices for control with growth of power. Also at present semiconductor switches are the key component in energy transmission, optimization of generation and network connection. The aim of this thesis is to make a survey of contemporary semiconductor components, showing difference in structures, advantages, disadvantages and most suitable applications. There is topical information about voltage, frequency and current limits of different switches. Study tries to compare dimensions and price of different components. Main manufacturers of semiconductor components are presented with the review of devices produced by them, and a conclusion about their availability was made. IGBT is selected as a main component in this study, because nowadays it is the most attractive component for usage in power drives, especially at the low levels of medium voltage. History of development of IGBT structure, static and dynamic characteristics are considered. Thesis tells about assemblies and connection of components and problems which can appear. One of key questions about semiconductor materials and their future development was considered. For the purpose of comparison strong and weak sides of different switches, calculation of losses of IGBT and its basic competitor – IGCT is presented. This master’s thesis makes an effort to answer the question if there are at present possibilities of accurate selection of switches for electrical drives of different rates of power and looks at future possible ways of development of semiconductor market.