994 resultados para Laser range finder


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present results, obtained by means of an analytic study and a numerical simulation, about the resonant condition necessary to produce a Localized Surface Plasmonic Resonance (LSPR) effect at the surface of metal nanospheres embedded in an amorphous silicon matrix. The study is based on a Lorentz dispersive model for a-Si:H permittivity and a Drude model for the metals. Considering the absorption spectra of a-Si:H, the best choice for the metal nanoparticles appears to be aluminium, indium or magnesium. No difference has been observed when considering a-SiC:H. Finite-difference time-domain (FDTD) simulation of an Al nanosphere embedded into an amorphous silicon matrix shows an increased scattering radius and the presence of LSPR induced by the metal/semiconductor interaction under green light (560 nm) illumination. Further results include the effect of the nanoparticles shape (nano-ellipsoids) in controlling the wavelength suitable to produce LSPR. It has been shown that is possible to produce LSPR in the red part of the visible spectrum (the most critical for a-Si:H solar cells applications in terms of light absorption enhancement) with aluminium nano-ellipsoids. As an additional results we may conclude that the double Lorentz-Lorenz model for the optical functions of a-Si:H is numerically stable in 3D simulations and can be used safely in the FDTD algorithm. A further simulation study is directed to determine an optimal spatial distribution of Al nanoparticles, with variable shapes, capable to enhance light absorption in the red part of the visible spectrum, exploiting light trapping and plasmonic effects. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A exploração do meio subaquático utilizando visão computacional é ainda um processo complexo. Geralmente são utilizados sistemas de visão baseados em visão stereo, no entanto, esta abordagem apresenta limitações, é pouco precisa e é exigente em termos computacionais quando o meio de operação é o subaquático. Estas limitações surgem principalmente em dois cenários de aplicação: quando existe escassez de iluminação e em operações junto a infraestruturas subaquáticas. Consequentemente, a solução reside na utilização de fontes de informação sensorial alternativas ou complementares ao sistema de visão computacional. Neste trabalho propõe-se o desenvolvimento de um sistema de percepção subaquático que combina uma câmara e um projetor laser de um feixe em linha, onde o projetor de luz estruturada _e utilizado como fonte de informação. Em qualquer sistema de visão computacional, e ainda mais relevante em sistemas baseados em triangulação, a sua correta calibração toma um papel fulcral para a qualidade das medidas obtidas com o sistema. A calibração do sistema de visão laser foi dividida em duas etapas. A primeira etapa diz respeito à calibração da câmara, onde são definidos os parâmetros intrínsecos e os parâmetros extrínsecos relativos a este sensor. A segunda etapa define a relação entre a câmara e o laser, sendo esta etapa necessária para a obtenção de imagens tridimensionais. Assim, um dos principais desafios desta dissertação passou por resolver o problema da calibração inerente a este sistema. Desse modo, foi desenvolvida uma ferramenta que requer, pelo menos duas fotos do padrão de xadrez, com perspectivas diferentes. O método proposto foi caracterizado e validado em ambientes secos e subaquáticos. Os resultados obtidos mostram que o sistema _e preciso e os valores de profundidade obtidos apresentam um erro significativamente baixo (inferiores a 1 mm), mesmo com uma base-line (distância entre a centro óptico da câmara e o plano de incidência do laser) reduzida.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do grau de Mestre em Engenharia Biomédica

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação de Mestrado em Conservação e Restauro - Metais

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O presente trabalho visa apresentar a temática da otimização da produção de corte laser numa empresa do ramo da indústria metalomecânica, denominada Sermec Laser e situada no concelho da Maia no Distrito do Porto. Para alcançar este objetivo foi necessário conhecer o funcionamento atual do processo, como por exemplo, os seus intervenientes, as taxas de ocupação do equipamento de corte a laser e os procedimentos. Só depois de ser explorada essa vertente será possível desenvolver um plano com vista a melhorar esse processo. Este projeto espera criar um plano de melhoria que será testado e, quando for validado, será implementado. As melhorias propostas por este plano passam pelo aumento da eficiência do processo de corte a laser e a alteração de parte do layout da empresa de forma a facilitar e agilizar este mesmo processo. O objetivo final será acrescentar mais valor ao processo, reduzindo os seus desperdícios. Com esta melhoria a empresa ficará a ganhar, pois irá produzir de forma mais ajustada às suas necessidades.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thesis submitted to the Universidade Nova de Lisboa, Faculdade de Ciências e Tecnologia, for the degree of Doctor of Philosophy in Biochemistry

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Multi-standard mobile devices are allowing users to enjoy higher data rates with ubiquitous connectivity. However, the benefits gained from multiple interfaces come at an expense—that being higher energy consumption in an era where mobile devices need to be energy compliant. One promising solution is the usage of short-range cooperative communication as an overlay for infrastructure-based networks taking advantage of its context information. However, the node discovery mechanism, which is pivotal to the bearer establishment process, still represents a major burden in terms of the total energy budget. In this paper, we propose a technology agnostic approach towards enhancing the MAC energy ratings by presenting a context-aware node discovery (CANDi) algorithm, which provides a priori knowledge towards the node discovery mechanism by allowing it to search nodes in the near vicinity at the ‘right time and at the right place’. We describe the different beacons required for establishing the cooperation, as well as the context information required, including battery level, modes, location and so on. CANDi uses the long-range network (WiMAX and WiFi) to distribute the context information about cooperative clusters (Ultra-wideband-based) in the vicinity. The searching nodes can use this context in locating the cooperative clusters/nodes, which facilitates the establishing of short-range connections. Analytical and simulation results are obtained, and the energy saving gains are further demonstrated in the laboratory using a customised testbed. CANDi saves up to 50% energy during the node discovery process, while the demonstrative testbed shows up to 75% savings in the total energy budget, thus validating the algorithm, as well as providing viable evidence to support the usage of short-range cooperative communications for energy savings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present work reports new sensors for the direct determination of Microcystin-LR (MC-LR) in environmental waters. Both selective membrane and solid contact were optimized to ensure suitable analytical features in potentiometric transduction. The sensing layer consisted of Imprinted Sol–Gel (ISG) materials capable of establishing surface interactions with MC-LR. Non-Imprinted Sol–Gel (NISG) membranes were used as negative control. The effects of an ionic lipophilic additive, time of sol–gel polymerization, time of extraction of MC-LR from the sensitive layer, and pH were also studied. The solid contact was made of carbon, aluminium, titanium, copper or nickel/chromium alloys (80 : 20 or 90 : 10). The best ISG sensor had a carbon solid contact and displayed average slopes of 211.3 mV per decade, with detection limits of 7.3 1010 M, corresponding to 0.75 mg L1 . It showed linear responses in the range of 7.7 1010 to 1.9 109 M of MC-LR (corresponding to 0.77–2.00 mg L1 ), thus including the limiting value for MC-LR in waters (1.0 mg L1 ). The potentiometric-selectivity coefficients were assessed by the matched potential method for ionic species regularly found in waters up to their limiting levels. Chloride (Cl) showed limited interference while aluminium (Al3+), ammonium (NH4 + ), magnesium (Mg2+), manganese (Mn2+), sodium (Na+ ), and sulfate (SO4 2) were unable to cause the required potential change. Spiked solutions were tested with the proposed sensor. The relative errors and standard deviation obtained confirmed the accuracy and precision of the method. It also offered the advantages of low cost, portability, easy operation and suitability for adaptation to flow methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The treatment of vascular lesions of the tongue is a very challenging procedure since the maintenance of the lingual tissue is of critical importance. Numerous treatment options have been described in literature but the Nd:YAG Laser appears to be one of the safest therapeutic options. We described a successful treatment of vascular lesions of the tongue with an excellent clinical result after only one treatment session with the Nd:YAG laser, with conservation of the lingual tissue and its functionality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: Avaliar a eficácia, a taxa de recorrência e as complicações da vaporização laser com CO2 no tratamento dos cistos da glândula de Bartholin. MÉTODOS: Estudo retrospectivo com 127 pacientes que apresentavam cistos sintomáticos da glândula de Bartholin submetidas à vaporização laser CO2 na nossa instituição de janeiro de 2005 a junho de 2011. Foram excluídas todas as pacientes com abcessos da glândula de Bartholin ou com suspeita de câncer. Todos os procedimentos foram realizados em regime ambulatorial, sob anestesia local. A coleta dos dados foi feita com base na consulta do processo clínico, tendo-se procedido à análise das características demográficas, dos parâmetros anatômicos, das complicações intra e pós-operatórias e dos dados de acompanhamento. Os dados foram armazenados e analisados no software Microsoft Excel® 2007, e os resultados foram apresentados como frequência (porcentagem) ou média±desvio padrão. As taxas de complicações, recorrência e cura foram calculadas. RESULTADOS: A idade média das pacientes foi de 37,3±9,5 anos (variando entre 18 e 61 anos). Setenta por cento(n=85) delas eram multíparas. A queixa mais frequente foi dor e 47,2% (n=60) das pacientes tinham antecedentes de tratamento médico e/ou cirúrgico por abcesso da glândula de Bartholin. A dimensão média dos cistos foi de 2,7±0,9 cm. Foram verificados três (2,4%) casos de hemorragia intraoperatória ligeira e 17 (13,4%) recorrências durante um período médio de 14,6 meses (variando entre 1 e 56 meses): dez abscessos da glândula de Bartholin e sete cistos recorrentes, que precisavam de uma nova intervenção cirúrgica. A taxa de cura após um único tratamento à laser foi de 86,6%. Dentre as cinco pacientes com doença recorrente que foram submetidas a um segundo procedimento com laser, a taxa de cura foi de 100%. CONCLUSÕES: Na presente instituição, a vaporização laser com CO2 parece ser uma opção terapêutica segura e eficaz no tratamento dos cistos da glândula de Bartholin.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

SUMMARY In Brazil, the existing reference values for T-lymphocytes subsets are based on data originated in other countries. There is no local information on normal variation for these parameters in Brazilian adults and children. We evaluated the normal variation found in blood donors from five large Brazilian cities, in different regions, and in children living in Salvador, and Rio de Janeiro. All samples were processed by flow cytometry. The results were analyzed according to region, gender, and lifestyle of blood donors. A total of 641 adults (63% males), and 280 children (58% males) were involved in the study. The absolute CD3+, and CD4+ cells count were significantly higher for females (adults and children). Higher CD4+ cell count in adults was associated with smoking, while higher CD8+ count was found among female children. Higher counts, for all T-cells subsets, were detected in blood donors from southeast / south regions while those living in the northern region had the lowest values. Individuals from midwestern and northeastern regions had an intermediate count for all these cells subsets. However, these differences did not reach statistical significance. In Brazil, gender and smoking, were the main determinants of differences in T-lymphocytes reference values.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introdução: A fasceíte plantar (FP) constitui a causa mais frequente de dor no retropé. Está recomendada uma prova terapêutica inicial conservadora. Objetivos: Caraterizar fatores demográficos e sintomáticos, terapêutica prévia e resultados de monoterapia com laser. Material e Métodos: Estudo observacional retrospetivo (12 meses). O tratamento aplicado foi laser infravermelho (AsGa 904nm; densidade de energia 20J/cm2; potência de pico 200mW). Fez-se análise estatística descritiva e comparativa (nível de significância de 0,05). Resultados: Seguiram-se 32 doentes com FP, com idade média de 54,28 anos (24–86; DP 13,95), 66% mulheres, Índice de Massa Corporal (IMC) médio de 30,18Kg/m2 (17,91-41,13; DP 5,19), 75% unilaterais, tempo médio de evolução de 6,28 meses (0,2-24; DP 6,82), 21 tinham feito previamente farmacoterapia e 12 outros tratamentos de MFR. O nível de dor inicial (END) médio foi 7,31 (5-10; DP 1,38). Dos 26 doentes tratados (6 perdas), 24 (92,3%) reportaram melhoria. O número médio de sessões foi 28,5 (11– 60; DP 14,01). O nível médio de dor final foi 0,75 (0-5; DP 2,37), com melhoria média de 89,7% (28,6%-100%; DP 0,16) do nível de dor. A intensidade de dor inicial foi maior em doentes com IMC superior (p=0,002). Não se encontraram outras relações estatisticamente significativas. Conclusões: A FP caraterizou-se por um nível de dor significativo (moderado a grave). A obesidade pareceu ser um fator de risco. A taxa de melhoria com o tratamento com laser foi muito satisfatória. A terapia com laser de baixa intensidade IV constitui uma boa opção terapêutica, a justificar avaliação suplementar por ensaios prospetivos controlados e randomizados.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertation submitted in partial fulfillment of the requirements for the Degree of Master of Science in Geospatial Technologies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Engenharia Física