995 resultados para Health Sciences, Radiology|Physics, Radiation|Biophysics, Medical


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Seventy percent of the population in Myanmar lives in rural areas. Although health workers are adequately trained, they are overburdened due to understaffing and insufficient supplies. Literature confirms that information and communication technologies can extend the reach of healthcare. In this paper, we present an SMS-based social network that aims to help health workers to interact with other medical professionals through topic-based message delivery. Topics describe interests of users and the content of message. A message is delivered by matching message content with user interests. Users describe topics as ICD- 10 codes, a comprehensive medical taxonomy. In this ICD-10 coded SMS, a set of prearranged codes provides a common language for users to send structured information that fits inside an SMS.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Two proton accelerators have been recently put in operation in Bern: an 18 MeV cyclotron and a 2 MeV RFQ linac. The commercial IBA 18/18 cyclotron, equipped with a specifically conceived 6 m long external beam line ending in a separate bunker, will provide beams for routine 18-F and other PET radioisotope production as well as for novel detector, radiation biophysics, radioprotection, radiochemistry and radiopharmacy developments. The accelerator is embedded into a complex building hosting two physics laboratories and four Good Manufacturing Practice (GMP) laboratories. This project is the result of a successful collaboration between the Inselspital, the University of Bern and private investors, aiming at the constitution of a combined medical and research centre able to provide the most cutting-edge technologies in medical imaging and cancer radiation therapy. The cyclotron is complemented by the RFQ with the primary goals of elemental analysis via Particle Induced Gamma Emission (PIGE), and the detection of potentially dangerous materials with high nitrogen content using the Gamma-Resonant Nuclear Absorption (GRNA) technique. In this context, beam instrumentation devices have been developed, in particular an innovative beam profile monitor based on doped silica fibres and a setup for emittance measurements using the pepper-pot technique. On this basis, the establishment of a proton therapy centre on the campus of the Inselspital is in the phase of advanced study.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Exposure to medium or high doses of ionizing radiation is a known risk factor for cancer in children. The extent to which low dose radiation from natural sources contributes to the risk of childhood cancer remains unclear. OBJECTIVES In a nationwide census-based cohort study, we investigated whether the incidence of childhood cancer was associated with background radiation from terrestrial gamma and cosmic rays. METHODS Children aged <16 years in the Swiss National Censuses in 1990 and 2000 were included. The follow-up period lasted until 2008 and incident cancer cases were identified from the Swiss Childhood Cancer Registry. A radiation model was used to predict dose rates from terrestrial and cosmic radiation at locations of residence. Cox regression models were used to assess associations between cancer risk and dose rates and cumulative dose since birth. RESULTS Among 2,093,660 children included at census, 1,782 incident cases of cancer were identified including 530 with leukemia, 328 with lymphoma, and 423 with a tumor of the central nervous system (CNS). Hazard ratios for each mSv increase in cumulative dose of external radiation were 1.03 (95% CI: 1.01, 1.05) for any cancer, 1.04 (1.00, 1.08) for leukemia, 1.01 (0.96, 1.05) for lymphoma, and 1.04 (1.00, 1.08) for CNS tumors. Adjustment for a range of potential confounders had little effect on the results. CONCLUSIONS Our study suggests that background radiation may contribute to the risk of cancer in children including leukemia and CNS tumors.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this research and development project was to develop a method, a design, and a prototype for gathering, managing, and presenting data about occupational injuries.^ State-of-the-art systems analysis and design methodologies were applied to the long standing problem in the field of occupational safety and health of processing workplace injuries data into information for safety and health program management as well as preliminary research about accident etiologies. The top-down planning and bottom-up implementation approach was utilized to design an occupational injury management information system. A description of a managerial control system and a comprehensive system to integrate safety and health program management was provided.^ The project showed that current management information systems (MIS) theory and methods could be applied successfully to the problems of employee injury surveillance and control program performance evaluation. The model developed in the first section was applied at The University of Texas Health Science Center at Houston (UTHSCH).^ The system in current use at the UTHSCH was described and evaluated, and a prototype was developed for the UTHSCH. The prototype incorporated procedures for collecting, storing, and retrieving records of injuries and the procedures necessary to prepare reports, analyses, and graphics for management in the Health Science Center. Examples of reports, analyses, and graphics presenting UTHSCH and computer generated data were included.^ It was concluded that a pilot test of this MIS should be implemented and evaluated at the UTHSCH and other settings. Further research and development efforts for the total safety and health management information systems, control systems, component systems, and variable selection should be pursued. Finally, integration of the safety and health program MIS into the comprehensive or executive MIS was recommended. ^

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper describes a study of the attitudes of elderly consumers toward dental care and oral health. Four hundred and two respondents ages 60-97 were interviewed with a 62 item questionnaire. Attitudes were measured regarding: quality of care, sufficient utilization of care, priority of oral health, patient-provider interaction, individual control over health, powerful others control of health, and chance as the locus of control over health. Analysis of variance was performed on the sample of males and females separately. Fifty-four hypotheses were tested on each sex. Race and self-concept were excellent predictors of attitude for both sexes and SES (socioeconomic status) and self-reported health were good predictors for females. There was no statistically significant relationship between the frequency with which the elderly utilize dental care and their attitudes toward the quality of care they receive. Foremost reason for non-utilization was that of no felt need. Those selecting this reason were likely to be Anglo females, wearers of dentures, in good health. Those selecting cost as the foremost reason for non-utilization were Black, in fair health, of either sex, missing some teeth, but with no dentures. Overall attitudes toward quality of dental care were positive, despite the fact that this group was exposed to dental care in its infancy. This may suggest that the elderly recognize the importance of technological advances in dentistry. Women with low income and education levels were more likely to have positive attitudes about quality of care than other females. Attitudes about interaction between patient and provider were overall negative. The sample scored high on individual control over health, and scored lower, but nonetheless positively, on feelings that persons other than themselves are most essential to maintaining health. Overall these elderly persons did not agree that they relied on chance in matters of health. Those who did choose this locus were female, with lower SES and health status. Though males scored high on internal control of health, those with lowest scores were Mexican-American or had never been married. Sex and ethnicity were the best predictors of attitude across all measures in the study.^

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This descriptive cross-sectional survey compared the perceptions of public health nursing practitioners, educators and administrators along two dimensions: the importance of community-focused functions in public health nursing and which occupational categories in public health are responsible for those functions. More than 50 percent of the mailed questionnaires that were sent to a systematic stratified nationwide sample of public health nurses were returned. In general, respondents: were female, were in their 40s, received their basic nursing education in baccalaureate programs, had either a baccalaureate or a master's degree, worked in official agencies or schools, and had approximately 14 years of experience in public health with six in their present position.^ Significant differences between practitioners, educators and administrators were found in their perceptions of both the importance of community-focused functions in public health nursing and in which occupational category they indicated as having the major responsibility to perform those functions. Educators and administrators perceived community-focused functions as more important than did practitioners. Overall the occupational category of administrator was indicated as having the major responsibility for performing community-focused functions.^

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The main goal of this study was to relate physical changes in image quality measured by Modulation Transfer Function (MTF) to diagnostic accuracy.^ One Hundred and Fifty Kodak Min-R screen/film combination conventional craniocaudal mammograms obtained with the Pfizer Microfocus Mammographic system were selected from the files of the Department of Radiology, at M.D. Anderson Hospital and Tumor Institute.^ The mammograms included 88 cases with a variety of benign diagnosis and 62 cases with a variety of malignant biopsy diagnosis. The average age of the patient population was 55 years old. 70 cases presented calcifications with 30 cases having calcifications smaller than 0.5mm. 46 cases presented irregular bordered masses larger than 1 cm. 30 cases presented smooth bordered masses with 20 larger than 1 cm.^ Four separated copies of the original images were made each having a different change in the MTF using a defocusing technique whereby copies of the original were obtained by light exposure through different thicknesses (spacing) of transparent film base.^ The mammograms were randomized, and evaluated by three experienced mammographers for the degree of visibility of various anatomical breast structures and pathological lesions (masses and calicifications), subjective image quality, and mammographic interpretation.^ 3,000 separate evaluations were anayzed by several statistical techniques including Receiver Operating Characteristic curve analysis, McNemar test for differences between proportions and the Landis et al. method of agreement weighted kappa for ordinal categorical data.^ Results from the statistical analysis show: (1) There were no statistical significant differences in the diagnostic accuracy of the observers when diagnosing from mammograms with the same MTF. (2) There were no statistically significant differences in diagnostic accuracy for each observer when diagnosing from mammograms with the different MTF's used in the study. (3) There statistical significant differences in detail visibility between the copies and the originals. Detail visibility was better in the originals. (4) Feature interpretations were not significantly different between the originals and the copies. (5) Perception of image quality did not affect image interpretation.^ Continuation and improvement of this research ca be accomplished by: using a case population more sensitive to MTF changes, i.e., asymptomatic women with minimum breast cancer, more observers (including less experienced radiologists and experienced technologists) must collaborate in the study, and using a minimum of 200 benign and 200 malignant cases.^

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Measurements of the natural background radiation have been made at numerous places throughout the world. Very little work in this field has been done in developing countries. In Mexico the natural radiation to which the population is exposed has not been assessed. This dissertation represents a pioneer study in this environmental area. The radiation exposure which occupants within buildings receive as a result of naturally occurring radionuclides present in construction materials is the principal focus.^ Data were collected between August 1979 and November 1980. Continuous monitoring was done with TLDs placed on site for periods of 3 to 6 months. The instrumentation used for "real-time" measurements was a portable NaI (Tl) scintillation detector. In addition, radiometric measurements were performed on construction materials commonly used in Mexican homes.^ Based on TLD readings taken within 75 dwellings, the typical indoor exposure for a resident of the study area is 9.2 (mu)Rh('-1). The average reading of the 152 indoor scintillometer surveys was 9.5 (mu)Rh('-1), the outdoor reading 7.5 (mu)Rh('-1). Results of one-way and multi-way analyses of the exposure data to determine the effect due to building materials type, geologic subsoil, age of dwelling, and elevation are also presented. The results of 152 indoor scintillometer surveys are described. ^

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Every x-ray attenuation curve inherently contains all the information necessary to extract the complete energy spectrum of a beam. To date, attempts to obtain accurate spectral information from attenuation data have been inadequate.^ This investigation presents a mathematical pair model, grounded in physical reality by the Laplace Transformation, to describe the attenuation of a photon beam and the corresponding bremsstrahlung spectral distribution. In addition the Laplace model has been mathematically extended to include characteristic radiation in a physically meaningful way. A method to determine the fraction of characteristic radiation in any diagnostic x-ray beam was introduced for use with the extended model.^ This work has examined the reconstructive capability of the Laplace pair model for a photon beam range of from 50 kVp to 25 MV, using both theoretical and experimental methods.^ In the diagnostic region, excellent agreement between a wide variety of experimental spectra and those reconstructed with the Laplace model was obtained when the atomic composition of the attenuators was accurately known. The model successfully reproduced a 2 MV spectrum but demonstrated difficulty in accurately reconstructing orthovoltage and 6 MV spectra. The 25 MV spectrum was successfully reconstructed although poor agreement with the spectrum obtained by Levy was found.^ The analysis of errors, performed with diagnostic energy data, demonstrated the relative insensitivity of the model to typical experimental errors and confirmed that the model can be successfully used to theoretically derive accurate spectral information from experimental attenuation data. ^