942 resultados para Free-Energy


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Free field and twisted parafermionic representations of twisted su(3)(k)((2)) current algebra are obtained. The corresponding twisted Sugawara energy-momentum tensor is given in terms of three (beta, gamma) pairs and two scalar fields and also in terms of twisted parafermionic currents and one scalar field. Two screening currents of the first kind are presented in terms of the free fields.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: To assess the accuracy of reporting from both a diet history and food record and identify some of the characteristics of more accurate reporters in a group of healthy adult volunteers for an energy balance study. Design: Prospective measurements in free-living people. Setting: Wollongong, Australia. Subjects: Fifteen healthy volunteers (seven male, eight female; aged 22 -59 y; body mass index (BMI) 19 - 33 kg/m(2)) from the local community in the city of Wollongong, Australia. Interventions: Measurement of energy intake via diet history interview and 7 day food records, total energy expenditure by the doubly labelled water technique over 14 days, physical activity by questionnaire, and body fat by dual-energy X-ray absorptiometry. Results: Increased misreporting of energy intake was associated with increased energy expenditure (r = 0.90, P < 0.0001, diet history; r(s)=0.79, P=0.0005, food records) but was not associated with age, sex, BMI or body fat. Range in number of recorded dinner foods correlated positively with energy expenditure (r(s)=0.63, P=0.01) and degree of misreporting (r(s)=0.71, P=0.003, diet history; r(s)=0.63, P=0.01, food records). Variation in energy intake at dinner and over the whole day identified by the food records correlated positively with energy expenditure (r=0.58, P = 0.02) and misreporting on the diet history (r=0.62, P=0.01). Conclusions: Subjects who are highly active or who have variable dietary and exercise behaviour may be less accurate in reporting dietary intake. Our findings indicate that it may be necessary to screen for these characteristics in studies where accuracy of reporting at an individual level is critical. Sponsorship: The study was supported in part by Australian Research Council funds made available through the University of Wollongong.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

in a recent publication, Eriksson et al. [1] explored the relationship between size at birth and resting metabolic rate and body composition in adulthood in a cohort of over 300 men and women. They reported an unexpected finding that people of both sexes who had a low birth weight also had a higher metabolic activity per unit muscle tissue. This conclusion was drawn from an analysis where resting metabolic rate (expressed as kcal/kg fat-free mass) in adulthood was examined relative to the birth weight of the subject. One explanation that they suggested was that the apparent increased activity of muscle tissue resulted from an increased sympathetic drive associated with low birth weight. There may be a less physiological reason for the findings of Eriksson et al. Whilst the data are not given specifically in the text, it can be seen clearly from Fig. 1 in the paper that the mean fat-free mass measured in adulthood increased, in both sexes, from the lightest birth weight group to the heaviest birth weight group when the cohort were divided into tertiles based on birth weight. The crux of the issue is that in many - indeed most - cases, expressing resting energy expenditure as kcal/kg fat-free mass does not totally adjust for fat-free mass [2 - 5], and a bias is introduced so that those who have a higher fat-free mass will tend to have a lower resting energy expenditure when expressed per kg fat-free mass. This bias found when expressing many physiological parameters relative to body size, body weight or body composition has long been known [6], and should be carefully considered by appropriate adjustment and hence analysis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Efficient intramolecular electronic energy transfer (EET) has been demonstrated for three novel bichromophoric compounds utilizing a macrocyclic spacer as the bridge between the electronic energy donor and acceptor fragments. As their free base forms, emission from the electronically excited donor is absent and the acceptor emission is reductively quenched via photoinduced oxidation of proximate amine lone pairs. As their Zn(II) complexes, excitation of the donor results in sensitization of the electronic acceptor emission.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this investigation was to assess changes in total energy expenditure (TEE), body weight (BW) and body composition following a peripheral blood stem cell transplant and following participation in a 3-month duration, moderate-intensity, mixed-type exercise programme. The doubly labelled and singly labelled water methods were used to measure TEE and total body water (TBW). Body weight and TBW were then used to calculate percentage body fat (%BF), and fat and fat-free mass (FFM). TEE and body composition measures were assessed pretransplant (PI), immediately post-transplant (PII) and 3 months post-PII (PIII). Following PII, 12 patients were divided equally into a control group (CG) or exercise intervention group (EG). While there was no change in TEE between pre- and post-transplant, BW (P

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: A knowledge of energy expenditure in infancy is required for the estimation of recommended daily amounts of food energy, for designing artificial infant feeds, and as a reference standard for studies of energy metabolism in disease states. Objectives: The objectives of this study were to construct centile reference charts for total energy expenditure (TEE) in infants across the first year of life. Methods: Repeated measures of TEE using the doubly labeled water technique were made in 162 infants at 1.5, 3, 6, 9 and 12 months. In total, 322 TEE measurements were obtained. The LMS method with maximum penalized likelihood was used to construct the centile reference charts. Centiles were constructed for TEE expressed as MJ/day and also expressed relative to body weight (BW) and fat-free mass (FFM). Results: TEE increased with age and was 1.40,1.86, 2.64, 3.07 and 3.65 MJ/day at 1.5, 3, 6, 9 and 12 months, respectively. The standard deviations were 0.43, 0.47, 0.52, 0.66 and 0.88, respectively. TEE in MJ/kg increased from 0.29 to 0.36 and in MJ/day/kg FFM from 0.36 to 0.48. Conclusions: We have presented centile reference charts for TEE expressed as MJ/day and expressed relative to BW and FFM in infants across the first year of life. There was a wide variation or biological scatter in TEE values seen at all ages. We suggest that these centile charts may be used to assess and possibly quantify abnormal energy metabolism in disease states in infants.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective - To evaluate the effect of prepregnancy body mass index (BMI), energy and macronutrient intakes during pregnancy, and gestational weight gain (GWG) on the body composition of full-term appropriate-for-gestational age neonates. Study Design - This is a cross-sectional study of a systematically recruited convenience sample of mother-infant pairs. Food intake during pregnancy was assessed by food frequency questionnaire and its nutritional value by the Food Processor Plus (ESHA Research Inc, Salem, OR). Neonatal body composition was assessed both by anthropometry and air displacement plethysmography. Explanatory models for neonatal body composition were tested by multiple linear regression analysis. Results - A total of 100 mother-infant pairs were included. Prepregnancy overweight was positively associated with offspring weight, weight/length, BMI, and fat-free mass in the whole sample; in males, it was also positively associated with midarm circumference, ponderal index, and fat mass. Higher energy intake from carbohydrate was positively associated with midarm circumference and weight/length in the whole sample. Higher GWG was positively associated with weight, length, and midarm circumference in females. Conclusion - Positive adjusted associations were found between both prepregnancy BMI and energy intake from carbohydrate and offspring body size in the whole sample. Positive adjusted associations were also found between prepregnancy overweight and adiposity in males, and between GWG and body size in females.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We look for minimal chiral sets of fermions beyond the standard model that are anomaly free and, simultaneously, vectorlike particles with respect to color SU(3) and electromagnetic U(1). We then study whether the addition of such particles to the standard model particle content allows for the unification of gauge couplings at a high energy scale, above 5.0 x 10(15) GeV so as to be safely consistent with proton decay bounds. The possibility to have unification at the string scale is also considered. Inspired in grand unified theories, we also search for minimal chiral fermion sets that belong to SU(5) multiplets, restricted to representations up to dimension 50. It is shown that, in various cases, it is possible to achieve gauge unification provided that some of the extra fermions decouple at relatively high intermediate scales.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Submitted in partial fulfillment of the requirements for the degree of Doctor of Philosophy in Electrical and Computer Engineering of the Faculdade de Ciências e Tecnologia of Universidade Nova de Lisboa

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dissertation to obtain the Doctoral degree in Physics Engineering

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A thermal Energy Storage Unit (ESU) could be used to attenuate inherent temperature fluctuations of a cold finger, either from a cryocooler working or due to sudden income heat bursts. An ESU directly coupled to the cold source acts as a thermal buffer temporarily increasing its cooling capacity and providing a better thermal stability of the cold finger (“Power Booster mode”). The energy storage units presented here use an enthalpy reservoir based on the high latent heat of the liquid-vapour transition of neon in the temperature range 38 - 44 K to store up to 900 J, and that uses a 6 liters expansion volume at RT in order to work as a closed system. Experimental results in the power booster mode will be described: in this case, the liquid neon cell was directly coupled to the cold finger of the working cryocooler, its volume (12 cm3) allowing it to store 450 J at around 40 K. 10 W heat bursts were applied, leading to liquid evaporation, with quite reduced temperature changes. The liquid neon reservoir can also work as a temporary cold source to be used after stopping the cryocooler, allowing for a vibration-free environment. In this case the enthalpy reservoir implemented (24 cm3) was linked to the cryocooler cold finger through a gas gap heat switch for thermal coupling/decoupling of the cold finger. We will show that, by controlling the enthalpy reservoir’s pressure, 900 J can be stored at a constant temperature of 40 K as in a triple-point ESU.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conformally flat spacetimes with an elastic stress energy tensor having diagonal trace-free anisotropic pressure are investigated using 1+3 formalism. The 1+3 Bianchi and Jacobi identities and Einstein field equations are written for a particular case with a conformal factor dependent on only one spatial coordinate. Solutions with non null anisotropic pressure are obtained.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this study I try to explain the systemic problem of the low economic competitiveness of nuclear energy for the production of electricity by carrying out a biophysical analysis of its production process. Given the fact that neither econometric approaches nor onedimensional methods of energy analyses are effective, I introduce the concept of biophysical explanation as a quantitative analysis capable of handling the inherent ambiguity associated with the concept of energy. In particular, the quantities of energy, considered as relevant for the assessment, can only be measured and aggregated after having agreed on a pre-analytical definition of a grammar characterizing a given set of finite transformations. Using this grammar it becomes possible to provide a biophysical explanation for the low economic competitiveness of nuclear energy in the production of electricity. When comparing the various unit operations of the process of production of electricity with nuclear energy to the analogous unit operations of the process of production of fossil energy, we see that the various phases of the process are the same. The only difference is related to characteristics of the process associated with the generation of heat which are completely different in the two systems. Since the cost of production of fossil energy provides the base line of economic competitiveness of electricity, the (lack of) economic competitiveness of the production of electricity from nuclear energy can be studied, by comparing the biophysical costs associated with the different unit operations taking place in nuclear and fossil power plants when generating process heat or net electricity. In particular, the analysis focuses on fossil-fuel requirements and labor requirements for those phases that both nuclear plants and fossil energy plants have in common: (i) mining; (ii) refining/enriching; (iii) generating heat/electricity; (iv) handling the pollution/radioactive wastes. By adopting this approach, it becomes possible to explain the systemic low economic competitiveness of nuclear energy in the production of electricity, because of: (i) its dependence on oil, limiting its possible role as a carbon-free alternative; (ii) the choices made in relation to its fuel cycle, especially whether it includes reprocessing operations or not; (iii) the unavoidable uncertainty in the definition of the characteristics of its process; (iv) its large inertia (lack of flexibility) due to issues of time scale; and (v) its low power level.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Total energy expenditure (TEE) and patterns of activity were measured by means of a heart rate (HR)-monitoring method in a group of 8-10-year-old children including 13 obese children (weight, 46 +/- 10 kg; fat mass: 32 +/- 9%) and 16 nonobese children (weight, 31 +/- 5 kg; fat mass, 18 +/- 5%). Time for sleeping was not statistically different in the two groups of children (596 +/- 33 vs. 582 +/- 43 min; p = NS). Obese children spent more time doing sedentary activities (400 +/- 129 vs. 295 +/- 127 min; p < 0.05) and less time in nonsedentary activities (449 +/- 126 vs. 563 +/- 135 min; p < 0.05) than nonobese children. Time spent in moderate or vigorous activity-i.e., time spent at a HR between 50% of the maximal O2 uptake (peak VO2) and 70% peak VO2 (moderate) and at a HR > or = 70% peak VO2 (vigorous)-was not statistically different in obese and nonobese children (88 +/- 69 vs. 52 +/- 35 min and 20 +/- 21 vs. 16 +/- 13 min, respectively; p = NS). TEE was significantly higher in the obese group than in the nonobese group (9.46 +/- 1.40 vs. 7.51 +/- 1.67 MJ/day; p < 0.01). The energy expenditure for physical activity (plus thermogenesis) was significantly higher in the obese children (3.98 +/- 1.30 vs. 2.94 +/- 1.39 MJ/day; p < 0.05). The proportion of TEE daily devoted to physical activity (plus thermogenesis) was not significantly different in the two groups, as shown by the ratio between TEE and the postabsorptive metabolic rate (PMR): 1.72 +/- 0.25 obese vs 1.61 +/- 0.28 non-obese. In conclusion, in free-living conditions obese children have a higher TEE than do nonobese children, despite the greater time devoted to sedentary activities. The higher energy cost to perform weight-bearing activities as well as the higher absolute PMR of obese children help explain this apparent paradox.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The number of physical activity measures and indexes used in the human literature is large and may result in some difficulty for the average investigator to choose the most appropriate measure. Accordingly, this review is intended to provide information on the utility and limitations of the various measures. Its primary focus is the objective assessment of free-living physical activity in humans based on physiological and biomechanical methods. The physical activity measures have been classified into three categories: Measures based on energy expenditure or oxygen uptake, such as activity energy expenditure, activity-related time equivalent, physical activity level, physical activity ratio, metabolic equivalent, and a new index of potential interest, daytime physical activity level. Measures based on heart rate monitoring, such as net heart rate, physical activity ratio heart rate, physical activity level heart rate, activity-related time equivalent, and daytime physical activity level heart rate. Measures based on whole-body accelerometry (counts/U time). Quantification of the velocity and duration of displacement in outdoor conditions by satellites using the Differential Global Positioning System may constitute a surrogate for physical activity, because walking is the primary activity of man in free-living conditions. A general outline of the measures and indexes described above is presented in tabular form, along with their respective definition, usual applications, advantages, and shortcomings. A practical example is given with typical values in obese and non-obese subjects. The various factors to be considered in the selection of physical activity methods include experimental goals, sample size, budget, cultural and social/environmental factors, physical burden for the subject, and statistical factors, such as accuracy and precision. It is concluded that no single current technique is able to quantify all aspects of physical activity under free-living conditions, requiring the use of complementary methods. In the future, physical activity sensors, which are of low-cost, small-sized, and convenient for subjects, investigators, and clinicians, are needed to reliably monitor, during extended periods in free-living situations, small changes in movements and grade as well as duration and intensity of typical physical activities.