991 resultados para Failure test


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Eighty purulent cerebrospinal fluid (CSF) samples from patients with clinical evidence of meningitis were studied using the Directigen latex agglutination (LA) kit to determine the presence of bacterial antigen in CSF. The results showed a better diagnostic performance of the LA test than bacterioscopy by Gram stain, culture and counterimmunoelectrophoresis (CIE), as far as Neisseria meningitidis groups B and C, and Haemophilus influenzae type b are concerned, and a better performance than bacterioscopy and culture considering Streptococcus pneumoniae. Comparison of the results with those of culture showed that the LA test had the highest sensitivity for the Neisseria meningitidis group C. Comparing the results with those of CIE, the highest levels of sensitivity were detected for N. meningitidis groups B and C. Regarding specificity, fair values were obtained for all organisms tested. The degree of K agreement when the LA test was compared with CIE exhibited better K indices of agreement for N. meningitidis groups B and C.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

No panorama socioeconómico atual, a contenção de despesas e o corte no financiamento de serviços secundários consumidores de recursos conduzem à reformulação de processos e métodos das instituições públicas, que procuram manter a qualidade de vida dos seus cidadãos através de programas que se mostrem mais eficientes e económicos. O crescimento sustentado das tecnologias móveis, em conjunção com o aparecimento de novos paradigmas de interação pessoa-máquina com recurso a sensores e sistemas conscientes do contexto, criaram oportunidades de negócio na área do desenvolvimento de aplicações com vertente cívica para indivíduos e empresas, sensibilizando-os para a disponibilização de serviços orientados ao cidadão. Estas oportunidades de negócio incitaram a equipa do projeto a desenvolver uma plataforma de notificação de problemas urbanos baseada no seu sistema de informação geográfico para entidades municipais. O objetivo principal desta investigação foca a idealização, conceção e implementação de uma solução completa de notificação de problemas urbanos de caráter não urgente, distinta da concorrência pela facilidade com que os cidadãos são capazes de reportar situações que condicionam o seu dia-a-dia. Para alcançar esta distinção da restante oferta, foram realizados diversos estudos para determinar características inovadoras a implementar, assim como todas as funcionalidades base expectáveis neste tipo de sistemas. Esses estudos determinaram a implementação de técnicas de demarcação manual das zonas problemáticas e reconhecimento automático do tipo de problema reportado nas imagens, ambas desenvolvidas no âmbito deste projeto. Para a correta implementação dos módulos de demarcação e reconhecimento de imagem, foram feitos levantamentos do estado da arte destas áreas, fundamentando a escolha de métodos e tecnologias a integrar no projeto. Neste contexto, serão apresentadas em detalhe as várias fases que constituíram o processo de desenvolvimento da plataforma, desde a fase de estudo e comparação de ferramentas, metodologias, e técnicas para cada um dos conceitos abordados, passando pela proposta de um modelo de resolução, até à descrição pormenorizada dos algoritmos implementados. Por último, é realizada uma avaliação de desempenho ao par algoritmo/classificador desenvolvido, através da definição de métricas que estimam o sucesso ou insucesso do classificador de objetos. A avaliação é feita com base num conjunto de imagens de teste, recolhidas manualmente em plataformas públicas de notificação de problemas, confrontando os resultados obtidos pelo algoritmo com os resultados esperados.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Diversas alterações na concentração sérica dos hormônios tiroidianos têm sido descritas em associação a doenças crônicas não-tiroidianas. Com relação às doenças hepáticas crônicas, a síndrome do T3 baixo foi descrita em pacientes cirróticos, enquanto a síndrome do T4 elevado foi encontrada em esquistossomóticos com a forma hepatoesplênica compensada. Com o intuito de verificar se as alterações relatadas na esquistossomose mansônica eram de origem "periférica" ou "central", realizamos a prova do TRH-TSH em 12 pacientes esquistossomóticos "puros" (6 hepatointestinais e 6 hepatoesplênicos compensados) e em 5 indivíduos controle. Os resultados obtidos demonstram que o eixo hipotálamo-hipofisário é normal nas formas crônicas da esquistossomose e que provavelmente as alterações previamente relatadas devem ser '"periféricas" e não " centrais".

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The rising usage of distributed energy resources has been creating several problems in power systems operation. Virtual Power Players arise as a solution for the management of such resources. Additionally, approaching the main network as a series of subsystems gives birth to the concepts of smart grid and micro grid. Simulation, particularly based on multi-agent technology is suitable to model all these new and evolving concepts. MASGriP (Multi-Agent Smart Grid simulation Platform) is a system that was developed to allow deep studies of the mentioned concepts. This paper focuses on a laboratorial test bed which represents a house managed by a MASGriP player. This player is able to control a real installation, responding to requests sent by the system operators and reacting to observed events depending on the context.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A hemagglutination (HA) test was standardized using formalin- and tannin-treated gander red blood cells sensitized with a total salt extract of C. cellulosae (HA-Cc) and an antigenic extract of Cysticercus longicollis (HA-Cl) vesicular fluid. A total of 61 cerebrospinal fluid (CSF) samples were assayed, 41 from patients with neurocysticercosis and 20 from a control group, which were, respectively, reactive and non-reactive to ELISA using C. cellulosae. The CSF samples from the control group did not react and 35 (85.4%) and 34 (82.9%) CSF samples from patients were reactive to the HA-Cc and HA-Cl tests, respectively. The reagents ready for use were stable up to 6 months when stored at 4°C in 50% glycerol. The present results confirm that the reagent using Cysticercus longicollis stabilized with glycerol can be used as an alternative in the immunological diagnosis of neurocysticercosis

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A survey for canine tegumentary leishmaniasis (CTL) has been carried out between 1986 and 1993 in seven endemic localities for American cutaneous leishmaniasis in the State of Rio de Janeiro. 270 dogs have been examined for their clinical aspects, the development of delayed hypersensitivity (DHS) with Immunoleish antigen and with immunofluorescent antibody research of IgG (IF). 28.2% of them had ulcer lesions and 3.3% had scars. The lesions consisted of single (39.5%) and mucocutaneous lesions (31.6%), multiple cutaneous (25.0%) and mucocutaneous lesions associated with cutaneous ulcers (4.0%). Twelve (15.8%) isolates from biopsies were analyzed by zimodeme and schizodeme and identified as L. (V.) braziliensis. The overall prevalence of canine infection that was evaluated with the skin test was of 40.5% and with IF it was of 25.5%. Both tests showed a high positive rate with relation to the animals with mucosal lesions, as in the case of human mucocutaneous leishmaniasis. The comparison of the two tests showed the skin test to have a better performance although there was no statistical difference (p>0.05) between them. The proportional sensitivity and specificity was of 84.0% and 74.0%, respectively. The Immunoleish skin test and IF are useful tools to be employed in CTL field epidemiological surveys.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A case of a 37-week pregnant woman who developed a hemorrhagic syndrome and acute renal failure after contact with Lonomia caterpillars is reported. The accident also initiated labour and the patient gave birth to an alive child. Some pathophysiological aspects of the genital bleeding and of the acute renal failure are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The persistence of agglutinins detected by MAT has created some problems to the interpretation of the results. The aim of this study was to examine the data of serology from 70 patients with serologically confirmed diagnosis of leptospirosis by during 3-13 months after being affected with leptospires in order to elucidate the interpretation of the persistence of agglutinins detected by MAT. Sixty-one patients sera (87.14%) had titers equal or greater than 800. Of these, two individuals maintained titers of 800 thirteen months after the onset. This study showed that only one sample of sera with high titers is not reliable to determine the time at which infection occurred.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to validate the 14C-urea breath test for use in diagnosis of Helicobacter pylori infection. Thirty H. pylori positive patients, based on histologic test and thirty H. pylori negative patients by histology and anti-H. pylori IgG entered the study. Fasting patients drank 5 uCi of 14C-urea in 20 ml of water. Breath samples were collected at 0, 5, 10, 15, 20 and 30 min. The difference of cpm values between the two groups was significant at all the time intervals, besides time 0 (p<0.0001). At 20 min, the test gave 100% sensitivity and specificity with a cut-off value of 562 cpm. Females were higher expirers than males (p=0.005). 14C-urea breath test is highly accurate for Helicobacter pylori diagnosis. It is fast, simple and should be the non-invasive test used after treating Helicobacter pylori infection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We compared the indirect immunofluorescence assay (IFA) with Western blot (Wb) as a confirmatory method to detect antibodies anti retrovirus (HIV-1 and HTLV-I/II). Positive and negative HIV-1 and HTLV-I/II serum samples from different risk populations were studied. Sensitivity, specificity, positive, negative predictive and kappa index values were assayed, to assess the IFA efficiency versus Wb. The following cell lines were used as a source of viral antigens: H9 ( HTLV-III b); MT-2 and MT-4 (persistently infected with HTLV-I) and MO-T (persistently infected with HTLV-II). Sensitivity and specificity rates for HIV-1 were 96.80% and 98.60% respectively, while predictive positive and negative values were 99.50% and 92.00% respectively. No differences were found in HIV IFA performance between the various populations studied. As for IFA HTLV system, the sensitivity and specificity values were 97.91% and 100% respectively with positive and negative predictive values of 100% and 97.92%. Moreover, the sensitivity of the IFA for HTLV-I/II proved to be higher when the samples were tested simultaneously against both antigens (HTLV-I-MT-2 and HTLV-II-MO-T). The overall IFA efficiency for HIV-1 and HTLV-I/II-MT-2 antibody detection probed to be very satisfactory with an excellent correlation with Wb (Kappa indexes 0.93 and 0.98 respectively). These results confirmed that the IFA is a sensitive and specific alternative method for the confirmatory diagnosis of HIV-1 and HTLV-I/II infection in populations at different levels of risk to acquire the infection and suggest that IFA could be included in the serologic diagnostic algorithm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A aplicação do material compósito é neste momento bastante vasta, graças à combinação das suas características específicas, tais como, maior resistência específica e módulos específicos e melhor resistência à fadiga, quando comparados com os metais convencionais. Tais características, quando requeridas, tornam este material ideal para aplicações estruturais. Esta caminhada de sucesso iniciou desde muito cedo, quando o material compósito já era utilizado para fabrico de armas pelos mongóis e na construção civil pelos hebreus e egípcios, contudo, só a partir dos meados do século XX é que despertou interesses para aplicações mais modernas. Atualmente os materiais compósitos são utilizados em equipamentos domésticos, componentes elétricos e eletrónicos, passando por materiais desportivos, pela indústria automóvel e construção civil, até indústrias de grande exigência e visibilidade tecnológica como a aeronáutica, espacial e de defesa. Apesar das boas características apresentadas pelos materiais compósitos, no entanto, estes materiais têm tendência a perderem as suas propriedades quando submetidas a algumas operações de acabamento como a furação. A furação surge da necessidade de ligação de peças de um mesmo mecanismo. Os furos obtidos por este processo devem ser precisos e sem danos para garantir ligações de alta resistência e também precisas. A furação nos materiais compósitos é bastante complexa devido à sua heterogeneidade, anisotropia, sensibilidade ao calor e pelo facto de os reforços serem extremamente abrasivos. A operação de furação pode causar grandes danos na peça, como a delaminação a entrada, defeitos de circularidade do furo, danos de origem térmica e a delaminação à saída que se apresenta como o mais frequente e indesejável. Com base nesses pressupostos é que este trabalho foi desenvolvido de forma a tentar obter processos simples para determinação e previsão de danos em polímeros reforçados com fibras (de carbono neste caso) de forma a precavê-los. De forma a conseguir estes objetivos, foram realizados ensaios de início de delaminação segundo a proposta de Lachaud et al. e ensaios de pin-bearing segundo a proposta de Khashaba et al. Foram também examinadas extensões de danos de acordo com o modelo de Fator de delaminação ajustado apresentado por Davim et al. A partir dos ensaios, de pin-bearing, realizados foram analisadas influências do material e geometria da broca, do avanço utilizado na furação e de diferentes orientações de empilhamentos de placas na delaminação de laminados compósitos e ainda a influências dessas variáveis na força de rutura por pin-bearing. As principais conclusões tiradas daqui são que a delaminação aumenta com o aumento do avanço, o que já era esperado, as brocas em carboneto de tungsténio são as mais recomendas para a furação do material em causa e que a delaminação é superior para a placa cross-ply quando comparada com placas unidirecionais. Para a situação de ensaios de início de delaminação foram analisadas as influências da variação da espessura não cortada por baixo da broca/punção, de diferentes geometrias de brocas, da alteração de velocidade de ensaio e diferentes orientações de empilhamentos de placas na força de início de delaminação. Deste ensaio as principais conclusões são que a força de início de delaminação aumenta com o aumenta da espessura não cortada e a influência da velocidade de ensaio altera com a variação das orientações de empilhamento.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the present study ELISA was standardized for the diagnosis of swine cysticercosis based on necropsy parameters and confirmed positive and negative control sera. Serum samples from pigs with other infections were also assayed to determine possible cross-reactions. Four antigens were assayed: from Taenia crassiceps vesicular fluid (VF-Tcra) and crude larvae extract (T-Tcra), and from Taenia solium extracts of scolex (S-Ts) and of larvae (T-Ts). A checkerboard evaluation of antigen, serum and conjugate dilutions, as well as the use of Tween-20 and skim cow milk in wash and blocking solution had a marked effect on improving ELISA performance. All the antigens showed a good performance, but VF-Tcra was the best, with 96.0% and 80.0% sensitivities for cut-offs respectively at 2sd and 3sd, and corresponding specificities of 97.5% and 100.0%. Cross-reactivity was observed only with hydatidosis and ascaridiosis. In view of the high performance observed, the ELISA test should be recommended for the diagnosis of cysticercosis in suspected swine in slaughterhouses and for the screening of cysticercosis in swine production. These results will support integrated measures of cysticercosis control throughout the chain of swine production, effectively contributing to public health.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effectiveness of specific antibiotic treatment in severe leptospirosis is still under debate. As part of a prospective study designed to evaluate renal function recovery after leptospirosis acute renal failure (ARF) (ARF was defined as Pcr > or = 1.5 mg/dL), the clinical evolutions of 16 treated patients (T) were compared to those of 18 untreated patients (nT). Treatment or non-treatment was the option of each patient's attending infectologist. The penicillin treatment was always with 6 million IU/day for 8 days. No difference was found between the two groups in terms of age, gender, number of days from onset of symptoms to hospital admission, or results of laboratory tests performed upon admission and during hospitalization, but proteinuria was higher in the treated group. There were no significant difference in the other parameters employed to evaluate patients' clinical evolution as: length of hospital stay, days of fever, days to normalization of renal function, days to total bilirubins normalized or reached 1/3 of maximum value and days to normalization of platelet counts. Dialytic treatment indication and mortality were similar between group T and nT. In conclusion, penicillin therapy did not provide better clinical outcome in patients with leptospirosis and ARF.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An epizootic outbreak of rabies occurred in 1995 in Ribeirão Preto, SP, with 58 cases of animal rabies (54 dogs, 3 cats and 1 bat) confirmed by the Pasteur Institute of São Paulo, and one human death. The need to provide care to a large number of people for the application of equine rabies immune globulin (ERIG) prevented the execution of the skin sensitivity test (SST) and often also the execution of desensitization, procedures routinely used up to that time at the Emergency Unit of the University Hospital of the Faculty of Medicine of Ribeirão Preto, University of São Paulo (EU-UHFMRP-USP), a reference hospital for the application of heterologous sera. In view of our positive experience of several years with the abolition of SST and of the use of premedication before the application of antivenom sera, we used a similar schedule for ERIG application. Of the 1489 victims of animal bites, 1054 (71%) received ERIG; no patient was submitted to SST and all received intravenously anti-histamines (anti-H1 + anti-H2) and corticosteroids before the procedure. The patients were kept under observation for 60 to 180 minutes and no adverse reaction was observed. On the basis of these results, since December 1995 ERIG application has been decentralized in Ribeirão Preto and has become the responsibility of the Emergency Unit of the University Hospital and the Central Basic Health Unit, where the same routine is used. Since then, 4216 patients have received ERIG (1818 at the Basic Health Unit and 2398 at the EU-UHFMRP), with no problems. The ideal would be the routine use of human rabies immune globulin (HRIG) in public health programs, but this is problematic, because of their high cost. However, while this does not occur, the use of SST is no longer justified at the time of application of ERIG, in view of the clinical evidence of low predictive value and low sensitivity of SST involving the application of heterologous sera. It is very important to point out that a negative SST result may lead the health team to a feeling of false safety that no adverse reaction will occur, but this is not true for the anaphylactoid reactions. The decision to use premedication, which is based on knowledge about anaphylaxis and on the pharmacology of the medication used, is left to the judgment of health professionals, who should always be prepared for eventual untoward events.