924 resultados para Equipment Failure Analysis


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: the failure of osseointegration in oral rehabilitation has gained importance in current literature and in clinical practice. The integration of titanium dental implants in alveolar bone has been partly ascribed to the biocompatibility of the implant surface oxide layer. The aim of this investigation was to analyze the surface topography and composition of failed titanium dental implants in order to determine possible causes of failure.Methods: Twenty-one commercially pure titanium (cpTi) implants were retrieved from 16 patients (mean age of 50.33 +/- 11.81 years). Fourteen implants were retrieved before loading (early failures), six after loading (late failures), and one because of mandibular canal damage. The failure criterion was lack of osseointegration characterized as dental implant mobility. Two unused implants were used as a control group. All implant surfaces were examined by scanning electron microscopy (SEM) and energy-dispersive spectrometer x-ray (EDS) to element analysis. Evaluations were performed on several locations of the same implant.Results: SEM showed that the surface of all retrieved implants consisted of different degrees of organic residues, appearing mainly as dark stains. The surface topography presented as grooves and ridges along the machined surface similar to control group. Overall, foreign elements such as carbon, oxygen, sodium, calcium, silicon, and aluminum were detected in failed implants. The implants from control group presented no macroscopic contamination and clear signs of titanium.Conclusion: These preliminary results do not suggest any material-related cause for implant failures, although different element composition was assessed between failed implants and control implants.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The synaptonemal complex (SC) of specimens of Sos taurus taurus from the Holstein-Friesian, Piemontese, and Simmental breeds, was analysed. The analysis included quantification of the frequency of various types of abnormalities in the SC, and the frequency of calls with SC abnormalities. All animals had 29 autosomal bivalents and one sexual bivalent and the most frequently recorded abnormality was pairing failure. The number of cells with abnormalities in the Holstein-Friesian breed was 29.41%, in the Piemontese breed was 30.00% and in the Simmental breed it was 29.54%. The subspecies Bos taurus taurus had 29.63% of cells showing abnormalities with 57.33% of these abnormalities occurring in zygotene and 42.67% occurring in pachytene. Statistical analyses showed that there were no significant differences in the number of cells with SC abnormalities among the breeds studied. The frequency of cells with abnormalities, and the efect on the fertility of the Holstein-Friesian, Piemontese and Simmental breeds are discussed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective. To determine the influence of cement thickness and ceramic/cement bonding on stresses and failure of CAD/CAM crowns, using both multi-physics finite element analysis and monotonic testing.Methods. Axially symmetric FEA models were created for stress analysis of a stylized monolithic crown having resin cement thicknesses from 50 to 500 mu m under occlusal loading. Ceramic-cement interface was modeled as bonded or not-bonded (cement-dentin as bonded). Cement polymerization shrinkage was simulated as a thermal contraction. Loads necessary to reach stresses for radial cracking from the intaglio surface were calculated by FEA. Experimentally, feldspathic CAD/CAM crowns based on the FEA model were machined having different occlusal cementation spaces, etched and cemented to dentin analogs. Non-bonding of etched ceramic was achieved using a thin layer of poly(dimethylsiloxane). Crowns were loaded to failure at 5 N/s, with radial cracks detected acoustically.Results. Failure loads depended on the bonding condition and the cement thickness for both FEA and physical testing. Average fracture loads for bonded crowns were: 673.5 N at 50 mu m cement and 300.6 N at 500 mu m. FEA stresses due to polymerization shrinkage increased with the cement thickness overwhelming the protective effect of bonding, as was also seen experimentally. At 50 mu m cement thickness, bonded crowns withstood at least twice the load before failure than non-bonded crowns.Significance. Occlusal "fit" can have structural implications for CAD/CAM crowns; pre-cementation spaces around 50-100 mu m being recommended from this study. Bonding benefits were lost at thickness approaching 450-500 mu m due to polymerization shrinkage stresses. (C) 2012 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A dispersão da amostra de solo é uma etapa fundamental da análise granulométrica, sendo realizada mediante o uso de dispersantes químicos e agitação mecânica. O objetivo deste trabalho foi avaliar a eficiência de mesa agitadora reciprocante de baixa rotação na dispersão mecânica de amostras de solos de diferentes classes texturais. Foram realizadas análises granulométricas em 61 amostras com quatro repetições, empregando o método da pipeta para determinação da fração argila e tamisagem para determinação das frações areia grossa, areia fina e areia total, sendo o silte determinado por diferença. Na avaliação de desempenho, os resultados obtidos com uso da mesa agitadora reciprocante (MAR) foram comparados com dados disponíveis para as mesmas amostras oriundos de relatórios do Ensaio de Proficiência IAC para Laboratórios de Análises de Solos - Prolab/IAC. Análises de acurácia foram realizadas com base nos valores dos intervalos de confiança definidos para cada fração granulométrica componente de cada amostra ensaiada. Indicadores gráficos também foram utilizados na comparação de dados, por meio de dispersão e ajuste linear. A estatística descritiva indicou preponderância de baixa variabilidade em mais de 90 % dos resultados obtidos para as amostras de texturas arenosa, média e argilosa e em 68 % dos obtidos para as amostras de textura muito argilosa, indicando boa repetibilidade dos resultados obtidos com a MAR. Média variabilidade foi mais frequentemente associada à fração silte, seguida da fração areia fina. Os resultados das análises de sensibilidade indicam acurácia de 100 % nas três frações granulométricas - areia total, silte e argila - para todas as amostras analisadas pertencentes às classes texturais muito argilosa, argilosa e média. Para as nove amostras de textura arenosa, a acurácia média foi de 85,2 %, e os maiores desvios ocorreram em relação à fração silte. Nas aproximações lineares, coeficientes de correlação igual (silte) ou superiores (areia total e argila) a 0,93, bem como diferenças menores do que 0,16 entre os coeficientes angulares das retas e o valor unitário, indicam alta correlação entre os resultados de referência (Prolab/IAC) e os obtidos nos ensaios com a MAR. Conclui-se pelo desempenho satisfatório da mesa agitadora reciprocante de baixa rotação para dispersão mecânica de amostras de solo de diferentes classes texturais para fins de análise granulométrica, permitindo recomendar o uso alternativo do equipamento quando se emprega agitação lenta. As vantagens do uso do equipamento nacional incluem o baixo custo, a possibilidade de análise simultânea de grande número de amostras e o uso de frascos comuns, de vidro ou de plástico, baratos e de fácil reposição.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The widespread falsification and/or adulteration of commercially available pharmaceutical preparations call for reliable methods of drug identification, preferably through selective and rapid sorting color tests that could be undertaken with minimum equipment remote from laboratory facilities. The present work deals with a convenient adaptation and refinement of a spot test devised by Feigl (1966) for urotropine, based on the hydrolytic cleavage of that substance in the presence of sulfuric acid, splitting out formaldehyde which is identified by its color reaction with chromotropic acid. A simple emergency kit was developed for the quick, efficient, inexpensive and easy performance of urotropine tests by semiskilled personnel even in the drugstore laboratory (or office) as well as in a mobile screening operation. It is shown that when the reagents are added according to the recommended sequence a self-heating system is generated, increasing substantially the reactions' rates and the test sensitivity as well. The identification limit found was 25 mug of urotropine, for both solid and liquid samples. The possible interference of 84 substances/materials was investigated. Interference was noted only for methylene blue, acriflavine, Ponceau Red, Bordeaux Red (these dyes are often included in urotropine dosage forms), pyramidone, dipyrone, quinine and tetracycline. A simple procedure for removing most of the interferences is described. Data for 8 commercial dosage forms and results obtained from their analysis are presented.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The CDKN1A (TP21)(2) gene encodes a 21-kD protein that is a critical downstream mediator of wild-type TP53 and an important regulator of the cell cycle. Failure in the function of this gene would be expected to result in abnormal cell proliferation and transformation. Tumor-associated mutations of the coding region of the TP21 are rare. on the other hand, some TP21 polymorphisms have been identified and characterized by single base substitutions. In the present study, we investigated the potential role of TP21 gene polymorphisms in skin, head, and neck tumorigenesis. A total of 261 samples were examined by polymerase chain reaction single-strand conformational analysis, and one mutation at codon 31 and four polymorphisms in exons 2 (codon 55) and 3 [nucleotide (nt)590] and in promoter region (nt2298) were identified. In conclusion, this investigation confirmed the rarity of mutations in this gene, arguing against a role for TP21 mutations in skin, head, and neck cancers. Also, our results show significant differences in nt2298 allele frequencies between normal individuals and skin malignant tumors (P < 0.05). The results suggest that this polymorphism affects TP21 transactivator binding and may be important during the pathogenesis of skin cancer. (C) 2003 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this work it was performed energetic and exergetic analyses of three thermal plants to assessment a cogeneration system in expansion of a sugar-alcohol factory. The initial configuration considered is constituted by a low pressure steam generator, single stage steam turbines for electricity generation and crusher, shredder and mills with mechanical driving. In the intermediary configuration, the low pressure steam generator was substituted by another which generates steam at higher pressure and higher temperature, the steam turbines for electricity generation were substituted by a multiple stages extraction-condensation turbine and the other steam turbines were maintained. The final configuration consists in the substitution of these last turbines by electrical motors. Thermodynamic analyses were performed to evaluate the equipment and the overall plants efficiencies to permit a comparison among the plants. Besides of this, some important parameters of the sugar-alcohol factories were calculated.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Heat recovery devices are important in the optimization of thermal systems, since they can be used to reduce thermal losses to the environment. The use of heat pipes in these types of equipment can provide heat recoveries of higher efficiency, since both fluid flows are external and there are less contamination risks between the hot and cold fluids. The objective of this work is to study a heat recovery unit constructed with heat pipes and mainly, to analyze the influence of the inclination of the heat pipes on the performance of the equipment. For this analysis, a heat recovery unit was constructed which possesses 48 finned heat pipes in triangular geometry, the evaporator and condenser being of the same length. This unit was tested in an air-air system simulating a heat recovery process in which heat was supplied to the hot fluid by electrical resistances. The results have shown that there exists an inclination at which the system has a better performance, but for higher inclinations there is no significant increase of the efficiency of the system. This paper also presents the influence of inclination of heat pipes on effectiveness and NTU parameters which are important in heat exchanger design.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The economical viability of three cogeneration schemes as supplying alternatives for a hypothetical industrial process has been studied. A cost appropriation method based on Valero's studies (1986) has been used. This method enables the determination of exergetic flows, the Second Law efficiency of equipment and the monetary costs of the products acquired by the industrial process (steam and electrical energy). The criterion adopted for the selection is the global cost of the supplied products to the industrial process as regarding in Brazilian conditions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A synaptonemal complex (SC) study of specimens of Nellore and Gyr breeds of Bos taurus indicus was performed with the main objective to identify and determinate the frequency of abnormalities of SC and the frequency of cells with abnormalities. All animals analyzed had 29 autosomal bivalents and one sexual bivalent. The Nellore breed had 30.00% of cells with SC abnormalities while the Gyr breed had only 11.11%. Statistical analyses showed that there were not significant differences for the number of cells with abnormalities among the breeds studied. The subspecies Bos taurus indicus had 16.92% of cells showing abnormalities, being 62.82% of these abnormalities in zygotene and 37.18% in pachytene. Some aspects regarding the frequency of cells with abnormalities and the fertility of Nellore and Gyr breeds are discussed.