998 resultados para Egg Load


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper reports the impact on confinement and power load of the high-shape 2.5 MA ELMy H-mode scenario at JET of a change from all carbon plasma-facing components to an all metal wall. In preparation to this change, systematic studies of power load reduction and impact on confinement as a result of fuelling in combination with nitrogen seeding were carried out in JET-C and are compared with their counterpart in JET with a metallic wall. An unexpected and significant change is reported on the decrease in the pedestal confinement but is partially recovered with the injection of nitrogen.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes a fridge-freezer smart load model, which responds to external signals from the wholesale electricity market to support grid operations while switching the fridge-freezer on and off to maintain optimum operations for the owner. The key parameters of the model are the appliance dimensions, thermal mass, the fridge and freezer thermal time constants and the compressor power consumption. The model demonstrates that control strategies help to minimise load at times when the grid is under stress from high demand, and shift some load to a lower wholesale price or when there is excess renewable power. Three control strategies are proposed, based on peak shaving and valley filling, price signals and wind availability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study characterizes the domestic loads suitable to participate in the load participation scheme to make the power system more carbon and economically efficient by shifting the electricity demand profile towards periods when there is plentiful renewable in-feed.

A series of experiments have been performed on a common fridge-freezer, both completely empty and half full. The results presented are ambient temperature, temperature inside the fridge, temperature inside the drawer of the fridge, temperature inside the freezer, thermal time constants, power consumption and electric energy consumed.

The thermal time constants obtained clearly demonstrate the potential of such refrigeration load for Smart Customer Load Participation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Novel egg-laying boards were found to be effective in the biological control of the freshwater fish louse Argulus foliaceus in a 12.9 ha rainbow trout Oncorhynchus mykiss fishery which had a high prevalence and intensity of infection of juvenile parasites in the early spring of 1999. Approximately 228 000d during an extensive 14 week period of egg laying which peaked in June 1999. In contrast, only 1566 clutches were harvested in 2000, when egg laying activity showed a bi-modal distribution, peaking in May and again in July and August. iaceus on rainbow trout in consecutive years was 2.9 : 1 and 2.1 : 1. Estimates of the size of the female A. foliaceus population based on egg-laying activity in 1999 exceeded that derived from measurements of prevalence and intensity of infection, whereas in 2000, this was more in balance. A minimum temperature of 10 degree C was identified for egg laying, which occurred continuously from May to October in a broadly synchronous manner.. Copyright 2002 The Fisheries Society of the British Isles

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Grid operators and electricity retailers in Ireland manage peak demand, power system balancing and grid congestion by offering relevant incentives to consumers to reduce or shift their load. The need for active consumers in the home using smart appliances has never been greater, due to increased variable renewable generation and grid constraints. In this paper an aggregated model of a single compressor fridge-freezer population is developed. A price control strategy is examined to quantify and value demand response savings during a representative winter and summer week for Ireland in 2020. The results show an average reduction in fridge-freezer operating cost of 8.2% during winter and significantly lower during summer in Ireland. A peak reduction of at least 68% of the average winter refrigeration load is achieved consistently during the week analysed using a staggering control mode. An analysis of the current ancillary service payments confirms that these are insufficient to ensure widespread uptake by the small consumer, and new mechanisms need to be developed to make becoming an active consumer attractive. Demand response is proposed as a new ancillary service called ramping capability, as the need for this service will increase with more renewable energy penetration on the power system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There are many uncertainties in forecasting the charging and discharging capacity required by electric vehicles (EVs) often as a consequence of stochastic usage and intermittent travel. In terms of large-scale EV integration in future power networks this paper develops a capacity forecasting model which considers eight particular uncertainties in three categories. Using the model, a typical application of EVs to load levelling is presented and exemplified using a UK 2020 case study. The results presented in this paper demonstrate that the proposed model is accurate for charge and discharge prediction and a feasible basis for steady-state analysis required for large-scale EV integration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper details the theory and implementation of a composite damage model, addressing damage within a ply (intralaminar) and delamination (interlaminar), for the simulation of crushing of laminated composite structures. It includes a more accurate determination of the characteristic length to achieve mesh objectivity in capturing intralaminar damage consisting of matrix cracking and fibre failure, a load-history dependent material response, an isotropic hardening nonlinear matrix response, as well as a more physically-based interactive matrix-dominated damage mechanism. The developed damage model requires a set of material parameters obtained from a combination of standard and non-standard material characterisation tests. The fidelity of the model mitigates the need to manipulate, or "calibrate", the input data to achieve good agreement with experimental results. The intralaminar damage model was implemented as a VUMAT subroutine, and used in conjunction with an existing interlaminar damage model, in Abaqus/Explicit. This approach was validated through the simulation of the crushing of a cross-ply composite tube with a tulip-shaped trigger, loaded in uniaxial compression. Despite the complexity of the chosen geometry, excellent correlation was achieved with experimental results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Inbreeding depression is most pronounced for traits closely associated with fitness. The traditional explanation is that natural selection eliminates deleterious mutations with additive or dominant effects more effectively than recessive mutations, leading to directional dominance for traits subject to strong directional selection. Here we report the unexpected finding that, in the butterfly Bicyclus anynana, male sterility contributes disproportionately to inbreeding depression for fitness (complete sterility in about half the sons from brother-sister matings), while female fertility is insensitive to inbreeding. The contrast between the sexes for functionally equivalent traits is inconsistent with standard selection arguments, and suggests that trait-specific developmental properties and cryptic selection play crucial roles in shaping genetic architecture. There is evidence that spermatogenesis is less developmentally stable than oogenesis, though the unusually high male fertility load in B. anynana additionally suggests the operation of complex selection maintaining male sterility recessives. Analysis of the precise causes of inbreeding depression will be needed to generate a model that reliably explains variation in directional dominance and reconciles the gap between observed and expected genetic loads carried by populations. This challenging evolutionary puzzle should stimulate work on the occurrence and causes of sex differences in fertility load.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Consumption of milk and dairy products is considered one of the main routes of human exposure to Mycobacterium avium subsp. paratuberculosis (MAP). Quantitative data on MAP load in raw cows’ milk are essential starting point for exposure assessment. Our study provides this information on a regional scale, estimating the load of MAP in bulk tank milk (BTM) produced in Emilia-Romagna region (Italy). The survey was carried out on 2934 BTM samples (88.6% of the farms herein present) using two different target sequences for qPCR (f57 and IS900). Data about the performances of both qPCRs are also reported, highlighting the superior sensitivity of IS900-qPCR. Seven hundred and eighty-nine samples tested MAP-positive (apparent prevalence 26.9%) by IS900 qPCR. However, only 90 of these samples were quantifiable by qPCR. The quantifiable samples contained a median load of 32.4 MAP cells mL−1 (and maximum load of 1424 MAP cells mL−1). This study has shown that a small proportion (3.1%) of BTM samples from Emilia-Romagna region contained MAP in excess of the limit of detection (1.5 × 101 MAP cells mL−1), indicating low potential exposure for consumers if the milk subsequently undergoes pasteurization or if it is destined to typical hard cheese production.