987 resultados para Efficiency Measurement


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hypoglycemia, if recurrent, may have severe consequences on cognitive and psychomotor development of neonates. Therefore, screening for hypoglycemia is a daily routine in every facility taking care of newborn infants. Point-of-care-testing (POCT) devices are interesting for neonatal use, as their handling is easy, measurements can be performed at bedside, demanded blood volume is small and results are readily available. However, such whole blood measurements are challenged by a wide variation of hematocrit in neonates and a spectrum of normal glucose concentration at the lower end of the test range. We conducted a prospective trial to check precision and accuracy of the best suitable POCT device for neonatal use from three leading companies in Europe. Of the three devices tested (Precision Xceed, Abbott; Elite XL, Bayer; Aviva Nano, Roche), Aviva Nano exhibited the best precision. None completely fulfilled the ISO-accuracy-criteria 15197: 2003 or 2011. Aviva Nano fulfilled these criteria in 92% of cases while the others were <87%. Precision Xceed reached the 95% limit of the 2003 ISO-criteria for values ≤4.2 mmol/L, but not for the higher range (71%). Although validated for adults, new POCT devices need to be specifically evaluated on newborn infants before adopting their routine use in neonatology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

During the recent period of economic crisis, many countries have introduced scrappage schemes to boost the sale and production of vehicles, particularly of vehicles designed to pollute less. In this paper, we analyze the impact of a particular scheme in Spain (Plan2000E) on vehicle prices and sales figures as well as on the reduction of polluting emissions from vehicles on the road. We considered the introduction of this scheme an exogenous policy change and because we could distinguish a control group (non-subsidized vehicles) and a treatment group (subsidized vehicles), before and after the introduction of the Plan, we were able to carry out our analysis as a quasi-natural experiment. Our study reveals that manufacturers increased vehicle prices by the same amount they were granted through the Plan (1,000 €). In terms of sales, econometric estimations revealed an increase of almost 5% as a result of the implementation of the Plan. With regard to environmental efficiency, we compared the costs (inverted quantity of money) and the benefits of the program (reductions in polluting emissions and additional fiscal revenues) and found that the Plan would only be beneficial if it boosted demand by at least 30%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It was observed in the city of Salvador, State of Bahia, the highest seroprevalence of human T cell lymphotropic virus type 1 (HTLV-I) infection in Brazil as demonstrated by national wide blood bank surveys. In this paper, we report results of an investigation of drug use and sexual behavior associated with HTLV-I infection among male and female injecting drug users (IDUs) in Salvador. A cross sectional study was conducted in the Historical District of Salvador from 1994-1996 (Projeto Brasil-Salvador) and 216 asymptomatic IDUs were selected using the snowball contact technique. Blood samples were collected for serological assays. Sera were screened for human immunodeficiency virus (HIV-1/2) and HTLV-I/II antibodies by ELISA and confirmed by Western blot. The overall prevalence of HTLV-I/II was 35.2% (76/216). The seroprevalence of HTLV-I, HTLV-II and HIV-1 was for males 22%, 11.3% and 44.1% and for females 46.2%, 10.3% and 74.4% respectively. HTLV-I was identified in 72.4% of HTLV positive IDUs. Variables which were significantly associated with HTLV-I infection among males included needle sharing practices, duration of injecting drug use, HIV-1 seropositivity and syphilis. Among women, duration of injecting drug use and syphilis were strongly associated with HTLV-I infection. Multivariate analysis did not change the direction of these associations. Sexual intercourse might play a more important role in HTLV-I infection among women than in men.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Zero correlation between measurement error and model error has been assumed in existing panel data models dealing specifically with measurement error. We extend this literature and propose a simple model where one regressor is mismeasured, allowing the measurement error to correlate with model error. Zero correlation between measurement error and model error is a special case in our model where correlated measurement error equals zero. We ask two research questions. First, we wonder if the correlated measurement error can be identified in the context of panel data. Second, we wonder if classical instrumental variables in panel data need to be adjusted when correlation between measurement error and model error cannot be ignored. Under some regularity conditions the answer is yes to both questions. We then propose a two-step estimation corresponding to the two questions. The first step estimates correlated measurement error from a reverse regression; and the second step estimates usual coefficients of interest using adjusted instruments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aimed to design and validate the measurement of ankle kinetics (force, moment, and power) during consecutive gait cycles and in the field using an ambulatory system. An ambulatory system consisting of plantar pressure insole and inertial sensors (3D gyroscopes and 3D accelerometers) on foot and shank was used. To test this system, 12 patients and 10 healthy elderly subjects wore shoes embedding this system and walked many times across a gait lab including a force-plate surrounded by seven cameras considered as the reference system. Then, the participants walked two 50-meter trials where only the ambulatory system was used. Ankle force components and sagittal moment of ankle measured by ambulatory system showed correlation coefficient (R) and normalized RMS error (NRMSE) of more than 0.94 and less than 13% in comparison with the references system for both patients and healthy subjects. Transverse moment of ankle and ankle power showed R>0.85 and NRMSE<23%. These parameters also showed high repeatability (CMC>0.7). In contrast, the ankle coronal moment of ankle demonstrated high error and lower repeatability. Except for ankle coronal moment, the kinetic features obtained by the ambulatory system could distinguish the patients with ankle osteoarthritis from healthy subjects when measured in 50-meter trials. The proposed ambulatory system can be easily accessible in most clinics and could assess main ankle kinetics quantities with acceptable error and repeatability for clinical evaluations. This system is therefore suggested for field measurement in clinical applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hypoglycaemia is a major cause of neonatal morbidity and may induce long-term developmental sequelae. Clinical signs of hypoglycaemia in neonatal infants are unspecific or even absent, and therefore, precise and accurate methods for the assessment of glycaemia are needed. Glycaemia measurement in newborns has some particularities like a very low limit of normal glucose concentration compared to adults and a large range of normal haematocrit values. Many bedside point-of-care testing (POCT) systems are available, but literature about their accuracy in newborn infants is scarce and not very convincing. In this retrospective study, we identified over a 1-year study period 1,324 paired glycaemia results, one obtained at bedside with one of three different POCT systems (Elite? XL, Ascensia? Contour? and ABL 735) and the other in the central laboratory of the hospital with the hexokinase reference method. All three POCT systems tended to overestimate glycaemia values, and none of them fulfilled the ISO 15197 accuracy criteria. The Elite XL appeared to be more appropriate than Contour to detect hypoglycaemia, however with a low specificity. Contour additionally showed an important inaccuracy with increasing haematocrit. The bench analyzer ABL 735 was the most accurate of the three tested POCT systems. Both of the tested handheld glucometers have important drawbacks in their use as screening tools for hypoglycaemia in newborn infants. ABL 735 could be a valuable alternative, but the blood volume needed is more than 15 times higher than for handheld glucometers. Before daily use in the newborn population, careful clinical evaluation of each new POCT system for glucose measurement is of utmost importance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Despite the central role of quantitative PCR (qPCR) in the quantification of mRNA transcripts, most analyses of qPCR data are still delegated to the software that comes with the qPCR apparatus. This is especially true for the handling of the fluorescence baseline. This article shows that baseline estimation errors are directly reflected in the observed PCR efficiency values and are thus propagated exponentially in the estimated starting concentrations as well as 'fold-difference' results. Because of the unknown origin and kinetics of the baseline fluorescence, the fluorescence values monitored in the initial cycles of the PCR reaction cannot be used to estimate a useful baseline value. An algorithm that estimates the baseline by reconstructing the log-linear phase downward from the early plateau phase of the PCR reaction was developed and shown to lead to very reproducible PCR efficiency values. PCR efficiency values were determined per sample by fitting a regression line to a subset of data points in the log-linear phase. The variability, as well as the bias, in qPCR results was significantly reduced when the mean of these PCR efficiencies per amplicon was used in the calculation of an estimate of the starting concentration per sample.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate the effects of recent advances in magnetic resonance imaging (MRI) radiofrequency (RF) coil and parallel imaging technology on brain volume measurement consistency. MATERIALS AND METHODS: In all, 103 whole-brain MRI volumes were acquired at a clinical 3T MRI, equipped with a 12- and 32-channel head coil, using the T1-weighted protocol as employed in the Alzheimer's Disease Neuroimaging Initiative study with parallel imaging accelerations ranging from 1 to 5. An experienced reader performed qualitative ratings of the images. For quantitative analysis, differences in composite width (CW, a measure of image similarity) and boundary shift integral (BSI, a measure of whole-brain atrophy) were calculated. RESULTS: Intra- and intersession comparisons of CW and BSI measures from scans with equal acceleration demonstrated excellent scan-rescan accuracy, even at the highest acceleration applied. Pairs-of-scans acquired with different accelerations exhibited poor scan-rescan consistency only when differences in the acceleration factor were maximized. A change in the coil hardware between compared scans was found to bias the BSI measure. CONCLUSION: The most important findings are that the accelerated acquisitions appear to be compatible with the assessment of high-quality quantitative information and that for highest scan-rescan accuracy in serial scans the acquisition protocol should be kept as consistent as possible over time. J. Magn. Reson. Imaging 2012;36:1234-1240. ©2012 Wiley Periodicals, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Urinary human chorionic gonadotropin (hCG) concentration is routinely measured in all anti-doping laboratories to exclude the misuse of recombinant or urinary hCG preparations. In this study, extended validation of two commercial immunoassays for hCG measurements in urine was performed. Both tests were initially designed for hCG determination in human serum/plasma. Methods: Access (R) and Elecsys (R) 1010 are two automated immunoanalysers for central laboratories. The limits of detection and quantification, as well as intra-laboratory and inter-technique correlation, precision, and accuracy, were determined. Stability studies of hCG in urine following freezing and thawing cycles (n = 3) as well as storage conditions at room temperature, 4 degrees C and 20 degrees C, were performed. Results: Statistical evaluation of hCG concentrations in male urine samples (n = 2429) measured with the Elecsys (R) 1010 system enabled us to draw a skewed frequency histogram and establish a far outside value equal to 2.3 IU/L. This decision limit corresponds to the concentration at which a sportsman will be considered positive for hCG. Intra-assay precision for the Access (R) analyser was less than 4.0 A, whereas the inter-assay precision was closer to 4.5 % (concentrations of the official external controls contained between 5.5 and 195.0 IU/L). Intra and inter-assay precision for the Elecsys (R) 1010 analyser was slightly better. A good inter-technique correlation was obtained when measuring various urine samples (male and female). No urinary hCG loss was observed after two freeze/thaw cycles. On the other hand, time and inappropriate storage conditions, such as temperatures above 10 degrees C for more than 5 days, can deteriorate urinary hCG. Conclusions: Both analysers showed acceptable performances and are suitable for screening urine for anti-doping analyses. Each laboratory should validate and establish its own reference values because hCG concentrations measured in urine can be different from one immunoassay to another. The time delay between urine collection and analysis should be reduced as much as possible, and urine samples should be transported in optimal conditions to avoid a loss of hCG immunoreactivity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bananal is an important focus of Schistosoma mansoni in the State of São Paulo. Accordingly, programmed active search for human cases, annual coproscopic surveys and treatment of infected cases were started in 1998, aiming at producing a sharp prevalence rate drop by the year 2000. S. mansoni eggs were searched for in two Kato-Katz slides per patient. Cases were followed up according to the routine of the local Family Health Program. In 1998, 130 samples out of 3,860 showed S. mansoni eggs; in 1999, 105 out of 3,550, and in 2000, 64 out of 3,528. Prevalence rates were 3.4%, 2.9%, and 1.8%, and average egg-counts 59, 64, and 79 eggs per gram of feces respectively. Prevalence rates decreased steadily after treatment, but persistently positive cases showed no significant decrease in parasite burdens. Egg count variation depended on sex and age bracket. Persistent residual cases admittedly preclude the eradication of this infection by only searching for and treating carriers. In addition, resistance to therapy and low sensitivity of fecal examinations, can not be ignored. Moderate to heavy worm burdens, frequently associated with hepatomegaly elsewhere, produced no serious cases in Bananal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Value for Money Report – The Efficiency and Effectiveness of Long-Stay Residential Care for Adults within the Mental Health Services Executive Summary and Contents PDF 164kb Chapters 1 and 2 – Introduction and Service Objectives PDF 504kb Chapter 3 plus annexes – Service Effectiveness and Efficiency PDF 3.7mb Chapter 4 – Service Resources PDF 2.4mb Chapters 5, 6 and 7 – Future Funding and Alternative Approaches, Key Performance Indicators, Conclusions and Recommendations PDF 2.4mb Appendices 1 to 6