939 resultados para Effects evaluation


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Mineral trioxide aggregate (MTA) and Portland cement are being used in dentistry as root-end-filling material for periapical surgery and for the sealing of communications between the root canal system and the surrounding tissues. However, genotoxicity tests for complete risk assessment of these compounds have not been conducted up to now. In the present study, the genotoxic effects of MTA and Portland cements were evaluated in peripheral lymphocytes from 10 volunteers by the alkaline single cell gel (comet) assay. The results pointed out that the single cell gel (comet) assay failed to detect the presence of DNA damage after a treatment of peripheral lymphocytes by MTA and Portland cements for concentrations up to 1000 mu g mL(-1). In summary, our results indicate that exposure to MTA or Portland cements may not be a factor that increases the level of DNA lesions in human peripheral lymphocytes as detected by single cell gel (comet) assay.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We evaluated the antimutagenic effect of Letinula edodes (Berk.) Pegler (Shiitake) on the frequency of micronuclei in mice treated with N-ethyl-N-nitrosourea (ENU) or cyclophosphamide (Cl?). Mice were orally (gavage) pretreated for 15 consecutive days with solutions of Shiitake (0.6 ml per day, gavage) prepared at three different temperatures: 4, 21 (RT), and 60 degreesC. Then, the animals were intraperitoneally injected on day 15 with CP (25 or 50 mg/kg) or ENU (50 mg/kg) and killed 24 or 48 h after treatment for evaluation of micronucleated polychromatic erythrocytes (MNPCEs) in bone marrow and micronucleated reticulocytes (MNRETs). A mixture of L. edodes lineages (LE 95/016, 96/14, 96/17, 96/22, 96/23, 97/27, and 97/28) significantly decreased the frequencies of MNPCEs and MNRETs induced by CP (25 and 50 mg/kg). When a single lineage from the mixture (LE 96/17) was tested we also found a significant reduction in the frequencies of MNPCEs and MNRETs induced by both CP or ENU (50 mg/kg). The comet assay was also performed 3 h after ENU treatment using mice pretreated with the single lineage (LE 96/17) of L. edodes. The results showed a high degree of variability with some indications of an antigenotoxic effect. Taken together, our data show that solutions from Shiitake inhibit in vivo mutagenicity of CP and ENU. (C) 2001 Elsevier B.V. B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study evaluated the effects of strain, stocking density and dietary energy level on the feathering of broiler chickens. Four trials were carried out between September 2000 and April 2002. There were 10,685 broiler chicks from the strains Ross 308, Cobb 500, Hybro PG, Hubbard, MPK, and Isa Vedette. The bids were reared at stocking densities varying between 10 and 16 birds/m² and were given diets containing different metabolizable energy levels. Broiler feathering was evaluated either by atrributing scores from 1 to 10 to feather covering along the thigh and back (visual inspection), or by determining the percentage weight of the feathers at 28 and 42 days of age. Increasing rearing densities resulted in poorer feathering, mainly if 12 or 13 birds/m² were compared with 16 birds/m². The strains showed different feathering; it was better in Cobb 500 and MPK birds, whereas Hubbard birds showed poorer feathering, mostly along the back. The energy level in the diet has also affected feathering scores. Medium energy level resulted in better feathering along the back at 28 days, and the low level, in better feathering along the thigh at 35 days of age. Finally, feather scores were better in females than in males.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To evaluate changes in mammographic density and Tc-99m-sestamibi scintimammographic uptake in postmenopausal women on hormone replacement therapy (HRT).Methods: Seventy-five postmenopausal women were prospectively studied and allocated into three groups: 50 women were randomized to either Group 1 (G1, n = 25), which received 2 mg of 17 beta-oestradiol continuously combined with 1 mg of norethisterone acetate (E-2/NETA, Kliogest (R), Medley) or Group 2 (G2), which received 2.5 mg/day of tibolone (Livial (R), Organon). The remaining 25 women, who were asymptomatic and had no desire to undergo HRT, constituted the control group (G3). Each patient was submitted to both mammography and scintimammography at baseline and after six months. Mammographic density was evaluated by using the BI-RADS classification system. The classification system of Barros et al. was used in the interpretation of scintimammography. For statistical analysis, the Chi-square test, ANOVA and Pearson's correlation were used.Results: At six months, increased mammographic density was observed in 48% of G1, 12% of G2 and 16% of G3 patients (p < 0.001). The increase in sestamibi uptake was 56% in G1, 28% in G2 and 24% in G3 (p < 0.001). Increases in both density and uptake were significantly higher in the group on E-2/NETA than among tibolone users and the controls.Conclusion: In postmenopausal women, HRT with E-2/NETA was associated with increased mammographic density and increased Tc-99m-sestamibi scintimammographic uptakes, suggesting greater mithochondrial activity in the cells of the mammary duct. This was not observed in users of 2.5 mg of tibolone, demonstrating that the effects on the breast were reduced. The same was observed in the control group. (c) 2005 Elsevier B.V.. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUÇÃO: a preservação da estrutura de esmalte após a remoção dos acessórios ortodônticos é obrigação do clínico. Portanto, procura-se um protocolo de descolagem com bases científicas. OBJETIVO: objetivou-se avaliar por microscopia eletrônica de varredura (MEV) a influência de quatro protocolos de remoção de braquetes e polimento da superfície do esmalte e propor um protocolo que minimize os danosà superfície do esmalte. MÉTODOS: doze incisivos permanentes bovinos foram divididos em quatro grupos de acordo com os instrumentos utilizados para a descolagem dos braquetes e remoção do remanescente adesivo. Os braquetes foram descolados com o alicate de descolagem reto (Ormco Corp.) nos grupos 1 e 2, e com o instrumento de descolagem Lift-Off (3M Unitek) nos grupos 3 e 4. Os remanescentes adesivos dos grupos 1 e 3 foram removidos com o alicate removedor de resina longo (Ormco Corp.) e dos grupos 2 e 4 com broca de carboneto de tungstênio (Beavers Dental) em alta-rotação. As superfícies, após cada etapa da descolagem e polimento, foram avaliadas em réplicas de resina epóxica e foram obtidas eletromicrografias com aumento de 50 e 200X. RESULTADOS: os quatro protocolos de remoção de acessórios ortodônticos e polimento ocasionaram irregularidades no esmalte. Conclusão: a remoção do braquete com o alicate de descolagem reto, seguido da remoção do remanescente adesivo com broca de carboneto de tungstênio e polimento final com pasta de pedra-pomes foi o procedimento que ocasionou menores danos ao esmalte, sendo o protocolo sugerido para a remoção dos acessórios ortodônticos.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: the aim of this study was to evaluate the progression of experimental peri-implantitis in dogs using implants with different surface coatings.Methods: Thirty-six dental implants with four different surface coatings, commercially pure titanium (cpTi), titanium plasma-sprayed (TPS), hydroxyapatite (HA), and acid-etched (AE), were placed in six mongrel dogs. Five months after implantation, peri-implantitis was induced by cotton ligatures to facilitate plaque accumulation for 60 days. After 60 days, the ligatures were removed and supragingival plaque control was initiated for 12 months. Probing depth (PD), clinical attachment level (CAL), vertical bone level (VBL), horizontal bone level (HBL), and mobility were obtained at baseline, and 20, 40, 60 (acute phase), and 425 days (chronic phase) after ligature removal.Results: PD and CAL changed around all implant surfaces after ligature placement (P < 0.0001). However, the means of PD and CAL were not statistically significant among the different surfaces (P > 0.05). The range of CAL variation, calculated between baseline and 60 days (acute phase) and between 60 and 425 days (chronic phase), decreased (P < 0.05). Bone loss increased during the entire experiment (P < 0.0001). The HA surface showed the greatest bone loss measurement (5.06 +/- 0.38 mm) and the TPS showed the smallest bone loss (4.27 +/- 0.62 mm). However, statistical significance was not assessed for different coatings (P > 0.05).Conclusions: the clinical data at the initial phase showed rapid and severe peri-implant tissue breakdown. However, removal of ligatures did not convert the acute destructive peri-implant phase to a non-aggressive lesion and the progression of peri-implantitis was observed at chronic phase. The,experimental peri-implantitis in dogs may be a useful model to evaluate the progression of peri-implantitis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Nanostructures on implant surfaces have been shown to enhance osseointegration; however, commonly used evaluation techniques are probably not sufficiently sensitive to fully determine the effects of this process. This study aimed to observe the osseointegration properties of nanostructured calcium phosphate (CaP)-coated implants, by using a combination of three-dimensional imaging and conventional histology. Titanium implants were coated with stable CaP nanoparticles using an immersion technique followed by heat treatment. Uncoated implants were used as the control. After topographical and chemical characterizations, implants were inserted into the rabbit femur. After 2 and 4 weeks, the samples were retrieved for micro-computed tomography and histomorphometric evaluation. Scanning electron microscopy evaluation indicated that the implant surface was modified at the nanoscale by CaP to obtain surface textured with rod-shaped structures. Relative to the control, the bone-to-implant contact for the CaP-coated implant was significantly higher at 4 weeks after the implant surgery. Further, corresponding 3-D images showed active bone formation surrounding the implant. 3-D quantification and 2-D histology demonstrated statistical correlation; moreover, 3-D quantification indicated a statistical decrease in bone density in the non-coated control implant group between 2 and 4 weeks after the surgery. The application of 3-D evaluation further clarified the temporal characteristics and biological reaction of implants in bone. (C) 2011 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.