989 resultados para Double Strap Joint
Resumo:
The general formulation of double refraction or internal double reflection for any directions of incidence and arbitrary orientation of the optic axis in a uniaxial crystal is analysed in terms of Huygens' principle. Then double refraction and double reflection along the sequential interfaces in a crystal are discussed. On this basis, if the parameters of the interface are chosen appropriately, the range of angular separation between the ordinary ray and extraordinary ray can be much greater, It is useful for crystal element design. Finally, as an example, an optimum design of the Output end interface for a 2 x 2 electro-optic switch is given.
Resumo:
A planar lightwave circuit (PLC) add-drop filter is proposed and analyzed, which consists of a symmetric Mach-Zehnder interferometer (MZI) combined with double microring resonators. A critical coupling condition is derived for a better box-like drop spectrum. Comparisons of its characteristics with other schemes, such as a MZI with a single ring resonator, arepresented, and some of the issues about device design and fabrication are also discussed.
Resumo:
In order to measure the diffraction-limit wavefront, we present three types of common-path double-shearing interferometers based on the theory of double shearing. Two pairs of half-aperture or whole-aperture wedge plates are used to introduce opposite tilt to realize the double-shearing function. By comparing the fringe widths in two fields, the marginal wavefront aberration can be obtained. In the paper, we give three different configurations: half-aperture configuration, whole-field configuration and double-interferometer configuration. The half-aperture configuration has the features of high sensitivity, stabilization and easy alignment. For the whole-field configuration, the interference fringes are displayed in two whole fields. Consequently, the divergent or convergent characteristic and aberration types of a wavefront can be identified visually. The whole-field configuration can be changed to the double-interferometer configuration for continuous test. Both small and large wavefront aberrations can be measured by the double-interferometer configuration. The minimum detectable wavefront aberration (W-0)(min) comes to 0.03 lambda. Lastly, we present the experimental results for the three types of double-shearing interferometers.
Resumo:
The original scanner for tilting orthogonal double prisms is studied to test the tracking performance in intersatellite laser communications. With a reduction ratio of more than 100 times from the change rate of the angle of beam deviation to that of the tilting angle of each prism, the theoretical analysis performed, as well as the verification experiment, indicates that the scanner can meet the requirements of the scanning accuracy superior to 0.5 mu rad with the scanning range greater than 500 mu rad and can facilitate the mechanical structure design. (c) 2006 Optical Society of America.
Resumo:
We describe the rigorous results of a wide-angle laser beam scanner, obtained with the help of the vector refraction theory. Using the rigorous results, the distortion of the beam shape is discussed. The distortion to the beam varies with the different relative angles of double prisms. The scanner expands the beam in some directions while it contracts the beam in other directions. According to the conservation of energy, the distribution of the laser intensity is changed as well. (c) 2006 Society of Photo-Optical Instrumentation Engineers.
Resumo:
Because of high efficiencies, compact structure, and excellent heat dissipation, high-power fiber lasers are extremely useful for applications such as cutting, welding, precision drilling, trimming, sensing, optical transmitter, material processing, micromachining, and so on. However, the wavefront of the double clad fiber laser doped with ytterbium is still unknown. In this paper, wavefront of a fiber laser is measured and the traditional Hartmann-shack wavefront sensing method is adopted. We measured a double clad fiber laser doped with ytterbium which produces pulse wave output at infrared wavelength. The wavefront shape and contour are reconstructed and the result shows that wavefront is slightly focused and not an ideal plane wavefront. Wavefront measurement of fiber laser will be useful to improving the lasers' performance and developing the coherent technique for its applications.
Resumo:
The frame of a laser diode transmitter for intersatellite communication is concisely introduced. A simple, novel and visual method for measuring the diffraction-limited wavefront of the transmitter by a Jamin double-shearing interferometer is proposed. To verify the validity of the measurement, the far-field divergence of beam is additionally rigorously analysed in terms of the Fraunhofer diffraction. The measurement, the necessary analyses and discussion are given in detail. By directly measuring the fringe widths and quantitatively interpreting the interference fringes, the minimum detectable wavefront height (DWH) of the wavefront is only 0.2 gimel (the distance between the perfect plane wavefront and the actual wavefront at the transmitting aperture) and the corresponding divergence is only 65.84 mu rad. This indicates that the wavefront approaches the diffraction-limited condition. The results show that this interferometer is a powerful tool for testing the semiconductor laser beam's wavefront, especially the diffraction-limited wavefront.
Resumo:
Grating pairs are widely used for pulse compression and stretching. Normally, the two gratings are identical. We propose a very simple structure with double-line-density reflective gratings for pulse compression and generation of double pulses, which has the advantages of no material dispersion, compact in volume, simple in structure, etc. The use of reflective Dammann gratings fully demonstrated the principle of this structure. The output pulses are well verified by a standard frequency-resolved optical gating apparatus. This structure will be highly interesting in ultrashort pulse compression and other more practical applications of femtosecond laser pulses. (c) 2007 Optical Society of America.
Resumo:
The overall goal of the joint research project is to relate the chemical reactions involved in the formation of organo-aluminium complexes under acid conditions to their toxic effects on the physiology of aquatic organisms. Finally, this research is intended to predict toxic effects arising from acidity and aluminium under varying environmental conditions. This interim report examines the chemical modelling of ion-binding by humic substances where a computer model has been developed and is being tested using field data, and conditions required for the precipitation of aluminium in surface waters.
Resumo:
As one part of an on-going programme concerned with environmental protection as provided for under the terms of a UK/USSR Joint Environmental Protection Agreement signed in London, 21 May 1974, a seminar — ”The elaboration of the scientific basis for monitoring the quality of surface water by hydrobiological indices” was held at Valdai in Russia 12—14 July, 1976. As a continuation of this theme it was agreed that delegations of hydrobiologists from each side should carry out reciprocal visits to carry out comparative field tests on selected systems of biological surveillance in use in the respective countries. In May 1978 a team of British hydrobiologists visited the USSR, under the auspices of the Department of Environment, to carry out joint exercises on the River Dnieper and some tributaries. This paper reports the results of selected methods used by the British side when applied to the conditions found in the River Dnieper.
Resumo:
In accordance with the plan for joint Anglo-Soviet scientific and technical collaboration on environmental problems, the comparative evaluation of systems of hydrobiological analysis of the surface water quality started in 1977 at the Regional Laboratory of the Severn-Trent Water Authority in Nottingham were continued in the spring of 1978. The investigations were carried out under the auspices of the Institute of Hydrobiology of the Academy of Sciences of the Ukrainian SSR. Hydrobiological and hydrochemical samples were collected by Soviet and British specialists from the Kiev reservoir and the rivers Dnieper, Sozh, Desna and Snov. The samples were processed on the expedition ships and in the Laboratory for the Hydrobiology of Small Water Bodies of the Institute of Hydrobiology of the Academy of Sciences of the Ukrainian SSR. The possible approved methods to be adopted were evaluated from the samples using the phytoperiphyton, phytoplankton, zooplankton and zoobenthos against a background of hydrochemical characteristics. The study concludes that weather conditions complicated the work on testing the systems of biological indication of water quality and made it inadvisable to use those methods of comparison which were used when similar work was carried out in Nottingham.
Resumo:
Doubled femtosecond laser pulses in-line are needed in the collinear pump-probe technique, collinear second harmonic generation frequency-resolved optical gating (SHG FROG) and the spectral phase interferometry for direct electric-field reconstruction (SPIDER), etc. Normally, it is generated by using a Michelson's structure. In this paper, we proposed a novel structure with two-layered reflective Dammann gratings and the reflective mirrors to generate doubled femtosecond laser pulses in line without transmission optical elements. Angular dispersion and spectral spatial walk-off are both compensated. In addition, this structure can also compress the positive chirped pulse, which cannot be realized with a Michelson's structure. By adopting triangular grating and blazed gratings, the efficiency of the system would in principle be increased as the Michelson's scheme. Experiments demonstrated that this method should be an alternative approach for generation of the double compressed pulses of femtosecond laser for practical applications. (c) 2006 Elsevier GmbH. All rights reserved.
Resumo:
Ultrafast lasers ablation of Cr film was investigated by using double-pulse method. Experimental results show that there exists a temporal ablation window effect with each of the double pulses adjusted just smaller than the threshold. When the delay between the double pulses is within the order of 400 ps, the ablation of Cr film could happen. When the delay between the double pulses is beyond the order of 400 ps, the ablation of Cr film would not happen, and the reflectivity from the surface of the Cr film shows a sharp rise at the same time. The two-temperature model was developed into the form of double pulses to explain the experimental phenomena. Furthermore, microbump structures were formed on the surface of Cr film after ablation by ultrafast double pulses. Their heights exhibit an obvious drop between 1 and 10 ps double pulses delay, which is involved with the electron-phonon coupling process according to the numerical simulation. These results should be helpful for understanding the dynamic processes during ultrafast lasers ablation of metal films. (C) 2008 Elsevier B.V. All rights reserved.
Resumo:
New exact solutions of the (2 + 1)-dimensional double sine-Gordon equation are studied by introducing the modified mapping relations between the cubic nonlinear Klein-Gordon system and double sine-Gordon equation. Two arbitrary functions are included into the Jacobi elliptic function solutions. New doubly periodic wave solutions are obtained and displayed graphically by proper selections of the arbitrary functions.