900 resultados para Difference method for differences
Resumo:
The concentrations of the water-soluble inorganic aerosol species, ammonium (NH4+), nitrate (NO3-), chloride (Cl-), and sulfate (SO42-), were measured from September to November 2002 at a pasture site in the Amazon Basin (Rondnia, Brazil) (LBA-SMOCC). Measurements were conducted using a semi-continuous technique (Wet-annular denuder/Steam-Jet Aerosol Collector: WAD/SJAC) and three integrating filter-based methods, namely (1) a denuder-filter pack (DFP: Teflon and impregnated Whatman filters), (2) a stacked-filter unit (SFU: polycarbonate filters), and (3) a High Volume dichotomous sampler (HiVol: quartz fiber filters). Measurements covered the late dry season (biomass burning), a transition period, and the onset of the wet season (clean conditions). Analyses of the particles collected on filters were performed using ion chromatography (IC) and Particle-Induced X-ray Emission spectrometry (PIXE). Season-dependent discrepancies were observed between the WAD/SJAC system and the filter-based samplers. During the dry season, when PM2.5 (D-p <= 2.5 mu m) concentrations were similar to 100 mu g m(-3), aerosol NH4+ and SO42- measured by the filter-based samplers were on average two times higher than those determined by the WAD/SJAC. Concentrations of aerosol NO3- and Cl- measured with the HiVol during daytime, and with the DFP during day- and nighttime also exceeded those of the WAD/SJAC by a factor of two. In contrast, aerosol NO3- and Cl- measured with the SFU during the dry season were nearly two times lower than those measured by the WAD/SJAC. These differences declined markedly during the transition period and towards the cleaner conditions during the onset of the wet season (PM2.5 similar to 5 mu g m(-3)); when filter-based samplers measured on average 40-90% less than the WAD/SJAC. The differences were not due to consistent systematic biases of the analytical techniques, but were apparently a result of prevailing environmental conditions and different sampling procedures. For the transition period and wet season, the significance of our results is reduced by a low number of data points. We argue that the observed differences are mainly attributable to (a) positive and negative filter sampling artifacts, (b) presence of organic compounds and organosulfates on filter substrates, and (c) a SJAC sampling efficiency of less than 100%.
Resumo:
In this work an efficient third order non-linear finite difference scheme for solving adaptively hyperbolic systems of one-dimensional conservation laws is developed. The method is based oil applying to the solution of the differential equation an interpolating wavelet transform at each time step, generating a multilevel representation for the solution, which is thresholded and a sparse point representation is generated. The numerical fluxes obtained by a Lax-Friedrichs flux splitting are evaluated oil the sparse grid by an essentially non-oscillatory (ENO) approximation, which chooses the locally smoothest stencil among all the possibilities for each point of the sparse grid. The time evolution of the differential operator is done on this sparse representation by a total variation diminishing (TVD) Runge-Kutta method. Four classical examples of initial value problems for the Euler equations of gas dynamics are accurately solved and their sparse solutions are analyzed with respect to the threshold parameters, confirming the efficiency of the wavelet transform as an adaptive grid generation technique. (C) 2008 IMACS. Published by Elsevier B.V. All rights reserved.
Resumo:
We present a variable time step, fully adaptive in space, hybrid method for the accurate simulation of incompressible two-phase flows in the presence of surface tension in two dimensions. The method is based on the hybrid level set/front-tracking approach proposed in [H. D. Ceniceros and A. M. Roma, J. Comput. Phys., 205, 391400, 2005]. Geometric, interfacial quantities are computed from front-tracking via the immersed-boundary setting while the signed distance (level set) function, which is evaluated fast and to machine precision, is used as a fluid indicator. The surface tension force is obtained by employing the mixed Eulerian/Lagrangian representation introduced in [S. Shin, S. I. Abdel-Khalik, V. Daru and D. Juric, J. Comput. Phys., 203, 493-516, 2005] whose success for greatly reducing parasitic currents has been demonstrated. The use of our accurate fluid indicator together with effective Lagrangian marker control enhance this parasitic current reduction by several orders of magnitude. To resolve accurately and efficiently sharp gradients and salient flow features we employ dynamic, adaptive mesh refinements. This spatial adaption is used in concert with a dynamic control of the distribution of the Lagrangian nodes along the fluid interface and a variable time step, linearly implicit time integration scheme. We present numerical examples designed to test the capabilities and performance of the proposed approach as well as three applications: the long-time evolution of a fluid interface undergoing Rayleigh-Taylor instability, an example of bubble ascending dynamics, and a drop impacting on a free interface whose dynamics we compare with both existing numerical and experimental data.
Resumo:
This work describes the development and optimization of a sequential injection method to automate the determination of paraquat by square-wave voltammetry employing a hanging mercury drop electrode. Automation by sequential injection enhanced the sampling throughput, improving the sensitivity and precision of the measurements as a consequence of the highly reproducible and efficient conditions of mass transport of the analyte toward the electrode surface. For instance, 212 analyses can be made per hour if the sample/standard solution is prepared off-line and the sequential injection system is used just to inject the solution towards the flow cell. In-line sample conditioning reduces the sampling frequency to 44 h(-1). Experiments were performed in 0.10 M NaCl, which was the carrier solution, using a frequency of 200 Hz, a pulse height of 25 mV, a potential step of 2 mV, and a flow rate of 100 mu L s(-1). For a concentration range between 0.010 and 0.25 mg L(-1), the current (i(p), mu A) read at the potential corresponding to the peak maximum fitted the following linear equation with the paraquat concentration (mg L(-1)): ip = (-20.5 +/- 0.3) Cparaquat -(0.02 +/- 0.03). The limits of detection and quantification were 2.0 and 7.0 mu g L(-1), respectively. The accuracy of the method was evaluated by recovery studies using spiked water samples that were also analyzed by molecular absorption spectrophotometry after reduction of paraquat with sodium dithionite in an alkaline medium. No evidence of statistically significant differences between the two methods was observed at the 95% confidence level.
Resumo:
Lead (Pb) poisoning is preventable but continues to be a public health problem in several countries. Measuring Pb in the surface dental enamel (SDE) using microbiopsies is a rapid, safe, and painless procedure. There are different protocols to perform these microbiopsies, but the reliability of dental enamel lead levels (DELL) determination is dependent upon biopsy depth (BD). It is established that DELL decrease from the outermost superficial layer to the inner layer of dental enamel. The aim of this study was to determine DELL obtained by two different microbiopsy techniques on SDE termed protocol I and protocol II. Two consecutive enamel layers were removed from the same subject group (n = 138) for both protocols. Protocol I consisted of a biopsied site with a diameter of 4 mm after the application of 10 l HCl for 35 s. Protocol II involved a biopsied site of 1.6 mm diameter after application of 5 l HCl for 20 s. The results demonstrated that there were no significant differences for BD and DELL between homologous teeth using protocol I. However, there was a significant difference between DELL in the first and second layers using both protocols. Further, the BD in protocol II overestimated DELL values. In conclusion, SDE analyzed by microbiopsy is a reliable biomarker in protocol I, but the chemical method to calculate BD in protocol II appeared to be inadequate for measurement of DELL. Thus, DELL could not be compared among studies that used different methodologies for SDE microbiopsies.
Resumo:
This paper describes the development of a sequential injection chromatography (SIC) procedure for separation and quantification of the herbicides simazine, atrazine, and propazine exploring the low backpressure of a 2.5 cm long monolithic C(18) column. The separation of the three compounds was achieved in less than 90 s with resolution > 1.5 using a mobile phase composed by ACN/1.25 mmol/L acetate buffer (pH 4.5) at the volumetric ratio of 35:65 and flow rate of 40 mu L/s. Detection was made at 223 nm using a flow cell with 40 mm of optical path length. The LOD was 10 mu g/L for the three triazines and the quantification limits were of 30 mu g/L for simazine and propazine and 40 mu g/L for atrazine. The sampling frequency is 27 samples per hour, consuming 1.1 mL of ACN per analysis. The proposed methodology was applied to spiked water samples and no statistically significant differences were observed in comparison to a conventional HPLC-UV method. The major metabolites of atrazine and other herbicides did not interfere in the analysis, being eluted from the column either together with the unretained peak, or at retention times well-resolved from the studied compounds.
Resumo:
Objective: To evaluate the flexural strength, microleakage, and degree of conversion of a microhybrid resin polymerized with argon laser and halogen lamp. Method and Materials: For both flexural test and degree of conversion analysis, 5 bar samples of composite resin were prepared and polymerized according to ISO 4049. The halogen light-curing unit was used with 500 MW/cm(2) for 20 seconds and the argon laser with 250 mW for 10 and 20 seconds. Samples were stored in distilled water in a dark environment at 37 degrees C for 24 hours. The flexural property was quantified by a 3-point loading test. For the microleakage evaluation, 60 bovine incisors were used to prepare standardized Class 5 cavities, which were restored and polished. Specimens were stored in distilled water for 24 hours at 37 degrees C and thermocycled 500 times (6 degrees C to 60 degrees C). Specimens were then immersed in art aqueous solution of basic fuchsin for 24 hours. Longitudinal sections of each restoration were obtained and examined with a stereomicroscope for qualitative evaluation of microleakage. Fourier transform (FT)-Raman RFS 100/S spectrometer (Bruker) was used to analyze the degree of conversion. Results: ANOVA showed no statistically significant differences of flexural strength between the photoactivation types evaluated in the flexural study. Microleakage data were statistically analyzed by Mann-Whitney and Kruskal-Wallis tests. Enamel margins resulted in a statistically lower degree of leakage than dentin margins. No statistically significant difference was found among the 3 types of photocuring studied. ANOVA also showed no statistically significant difference in the degree of conversion among the studied groups. Conclusion: According to the methodology used in this research, the argon laser is a possible alternative for photocuring, providing the same quality of polymerization as the halogen lamp. None of the photocured units tested in this study completely eliminated microleakage.
Resumo:
In this present work a method for the determination of Ca, Fe, Ga, Na, Si and Zn in alumina (Al(2)O(3)) by inductively coupled plasma optical emission spectrometry (ICP OES) with axial viewing is presented. Preliminary studies revealed intense aluminum spectral interference over the majority of elements and reaction between aluminum and quartz to form aluminosilicate, reducing drastically the lifetime of the torch. To overcome these problems alumina samples (250 mg) were dissolved with 5 mL HCl + 1.5 mLH(2)SO(4) + 1.5 mL H(2)O in a microwave oven. After complete dissolution the volume was completed to 20 mL and aluminum was precipitated as Al(OH)(3) with NH(3) (by bubbling NH(3) into the solution up to a pH similar to 8, for 10 min). The use of internal standards (Fe/Be, Ga/Dy, Zn/In and Na/Sc) was essential to obtain precise and accurate results. The reliability of the proposed method was checked by analysis of alumina certified reference material (Alumina Reduction Grade-699, NIST). The found concentrations (0.037%w(-1) CaO, 0.013% w w(-1) Fe(2)O(3), 0.012%w w(-1)Ga(2)O(3), 0.49% w w(-1) Na(2)O, 0.014% w w(-1) SiO(2) and 0.013% w w(-1) ZnO) presented no statistical differences compared to the certified values at a 95% confidence level. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
At the centre of this study lies the question if normative gender thinking affects the way poetry gets reviewed and how the reviews are written, this in relation to both the gender of the reviewer and the poet. The study crosses three academic fields; gender studies, poetry and journalism, and is based on the cultural studies theory of media affecting and even creating the world around it. The study is based on two types of analysis. One quantitative analysis based on the thematic criticism theory about detail studies that shows bigger patterns, this analysis focuses on how the poet and his/hers work are being treated in the reviews in areas such as how much space they´re given in the newspapers, how they are named by the reviewer and the tendency to quote the reviewed work. And one qualitative analysis based on the new criticism method of close reading, that focuses on the reviewers way of writing and how that may be connected with theories of gender differences, this both connected to the gender of the reviewers and the poets. The material chosen for this study are all the reviews that were published in the same newspapers and that reviewed two specific poetry works by two specific poets chosen with great sensibility to age and career so that their difference in gender would be the most significant difference between them. The works were chosen based on year of publishing, they were supposed to be published as newly as possible and as close to each other in time as possible. The works I ended up with were Dimman av allt (2001) and Svart som silver (2008) by Bruno K. Öijer and Silverskåp (2000) and Nu försvinner vi eller ingår (2007) by Birgitta Lillpers. The results of this study show several differences in how poetry is being judged and how poetry reviews are being written are connected with the gender of the poets and the reviewer. Lillpers got 35% less space in the newspapers and Öijers poetry got quoted a lot more which confirms that female poetry often is considered as less important than the male poetry, and that men in general tends to be judged as more professional than woman. The male reviewers tended to express themselves with greater certainty than the female reviewers who held a more professional tone in their reviews and focused more on the technical aspects of the poetry. This confirms the theory of the male words are being looked upon as the truth but contradicts the theory of women writing more based on personal experience and of women being less skilled in language techniques. In conclusion, there are differences in how poetry gets reviewed and how the reviews are written that are connected to the genders of the poet and the reviewer but these differences are complex and does not show a clear normative way of thinking about gender
Resumo:
In this paper the behavior of matter waves in suddenly terminated potential structures is investigated numerically. It is shown that there is no difference between a fully quantum mechanical treatment and a semiclassical one with regards to energy redistribution. For the quantum case it is demonstrated that there can be substantial reflection at the termination. The neglect of backscattering by the semiclassical method brings about major differences in the case of low kinetic energies. A simple phenomenological model is shown to partially explain the observed backscattering using dynamics of reduced dimensionality.
Resumo:
Animal traits differ not only in mean, but also in variation around the mean. For instance, one sire’s daughter group may be very homogeneous, while another sire’s daughters are much more heterogeneous in performance. The difference in residual variance can partially be explained by genetic differences. Models for such genetic heterogeneity of environmental variance include genetic effects for the mean and residual variance, and a correlation between the genetic effects for the mean and residual variance to measure how the residual variance might vary with the mean. The aim of this thesis was to develop a method based on double hierarchical generalized linear models for estimating genetic heteroscedasticity, and to apply it on four traits in two domestic animal species; teat count and litter size in pigs, and milk production and somatic cell count in dairy cows. The method developed is fast and has been implemented in software that is widely used in animal breeding, which makes it convenient to use. It is based on an approximation of double hierarchical generalized linear models by normal distributions. When having repeated observations on individuals or genetic groups, the estimates were found to be unbiased. For the traits studied, the estimated heritability values for the mean and the residual variance, and the genetic coefficients of variation, were found in the usual ranges reported. The genetic correlation between mean and residual variance was estimated for the pig traits only, and was found to be favorable for litter size, but unfavorable for teat count.
Resumo:
OBJECTIVES: To develop a method for objective assessment of fine motor timing variability in Parkinson’s disease (PD) patients, using digital spiral data gathered by a touch screen device. BACKGROUND: A retrospective analysis was conducted on data from 105 subjects including65 patients with advanced PD (group A), 15 intermediate patients experiencing motor fluctuations (group I), 15 early stage patients (group S), and 10 healthy elderly subjects (HE) were examined. The subjects were asked to perform repeated upper limb motor tasks by tracing a pre-drawn Archimedes spiral as shown on the screen of the device. The spiral tracing test was performed using an ergonomic pen stylus, using dominant hand. The test was repeated three times per test occasion and the subjects were instructed to complete it within 10 seconds. Digital spiral data including stylus position (x-ycoordinates) and timestamps (milliseconds) were collected and used in subsequent analysis. The total number of observations with the test battery were as follows: Swedish group (n=10079), Italian I group (n=822), Italian S group (n = 811), and HE (n=299). METHODS: The raw spiral data were processed with three data processing methods. To quantify motor timing variability during spiral drawing tasks Approximate Entropy (APEN) method was applied on digitized spiral data. APEN is designed to capture the amount of irregularity or complexity in time series. APEN requires determination of two parameters, namely, the window size and similarity measure. In our work and after experimentation, window size was set to 4 and similarity measure to 0.2 (20% of the standard deviation of the time series). The final score obtained by APEN was normalized by total drawing completion time and used in subsequent analysis. The score generated by this method is hence on denoted APEN. In addition, two more methods were applied on digital spiral data and their scores were used in subsequent analysis. The first method was based on Digital Wavelet Transform and Principal Component Analysis and generated a score representing spiral drawing impairment. The score generated by this method is hence on denoted WAV. The second method was based on standard deviation of frequency filtered drawing velocity. The score generated by this method is hence on denoted SDDV. Linear mixed-effects (LME) models were used to evaluate mean differences of the spiral scores of the three methods across the four subject groups. Test-retest reliability of the three scores was assessed after taking mean of the three possible correlations (Spearman’s rank coefficients) between the three test trials. Internal consistency of the methods was assessed by calculating correlations between their scores. RESULTS: When comparing mean spiral scores between the four subject groups, the APEN scores were different between HE subjects and three patient groups (P=0.626 for S group with 9.9% mean value difference, P=0.089 for I group with 30.2%, and P=0.0019 for A group with 44.1%). However, there were no significant differences in mean scores of the other two methods, except for the WAV between the HE and A groups (P<0.001). WAV and SDDV were highly and significantly correlated to each other with a coefficient of 0.69. However, APEN was not correlated to neither WAV nor SDDV with coefficients of 0.11 and 0.12, respectively. Test-retest reliability coefficients of the three scores were as follows: APEN (0.9), WAV(0.83) and SD-DV (0.55). CONCLUSIONS: The results show that the digital spiral analysis-based objective APEN measure is able to significantly differentiate the healthy subjects from patients at advanced level. In contrast to the other two methods (WAV and SDDV) that are designed to quantify dyskinesias (over-medications), this method can be useful for characterizing Off symptoms in PD. The APEN was not correlated to none of the other two methods indicating that it measures a different construct of upper limb motor function in PD patients than WAV and SDDV. The APEN also had a better test-retest reliability indicating that it is more stable and consistent over time than WAV and SDDV.
Resumo:
Syfte Syftet med studien är att analysera tillslagsprecision i fotboll och jämföra eventuella skillnader mellan juniorer och seniorer på både herr- och damsidan. Metod Totalt 30 elitspelare varav 16 herrar och 14 damer utförde tester i tillslagsprecision. De färdigheter som testades var passning och skott. Upplägget var 60 skott (30 stillaliggande och 30 halvvolley) och 80 passningar (20 stillaliggande bästa fot, 20 rullande bästa fot, 20 stillaliggande näst bästa fot och 20 rullande näst bästa fot). Testresultaten analyserades via Excel och Kinovea, där kunde medelvärden och standardavvikelser för varje testperson och testgrupp räknas ut. Resultat Resultatet visar att det endast var signifkant skillnad på ett av sex moment vad gäller tillslagsprecisionen på herrsidan. På damsidan var det ingen signifikant skillnad på något moment. Slutsatser Författarna har i denna studie identifierat en platå mellan spelare i åldrarna 16-18 år och seniorspelare vad gäller tillslagsprecision. Spelare i åldrarna 16-18 är lika bra som seniorspelare på de individuella färdigheterna passning och skott. Denna platå kan vara resultatet av för lite individuell träning, sk isolerad träning vad det gäller tillslagsprecision, på föreningsträningarna. Om föreningstränarna följer den utbildning SvFF ger dem ska endast två minuter per träning gå till varje individuell färdighet (13 st enligt SvFF). Bristen av tid för dessa färdigheter kan vara en avgörande faktor för att utvecklingen av tillslagsprecision står stilla idag.
Resumo:
Background: Acupuncture involves puncturing the skin with thin sterile needles at defined acupuncture points. Previous studies are inconclusive regarding the effect of acupuncture on labour pain, but some studies have found a reduction in the use of pharmacological pain relief when acupuncture is administered. The appropriate dose of acupuncture treatment required to elicit a potential effect on labour pain has not been fully explored. The dose is determined by many different factors, including the number of needles used and the intensity of the stimulation. In Sweden, manual stimulation of the needles is common practice when acupuncture is used for labour pain, but electrical stimulation of the needles, which gives a higher dose, could possibly be more effective. The overall aim of this thesis was to evaluate the effectiveness of acupuncture with manual stimulation (MA) of the needles as well as acupuncture with a combination of manual and electrical stimulation (EA) in reducing labour pain, compared with standard care without any form of acupuncture (SC). Methods: The study was designed as a three-armed randomised controlled trial in which 303 nulliparous women with normal pregnancies were randomised to MA, EA, or SC. The primary outcome was labour pain, assessed using the Visual Analogue Scale (VAS). Secondary outcomes were relaxation during labour, use of obstetric pain relief, and associations between maternal characteristics and labour pain and use of epidural analgesia respectively. Also, labour and infant outcomes, recollection of labour pain, and maternal experiences, such as birth experience and experience of the midwife, were investigated two months after the birth. The sample size calculation was based on the potential to discover a difference of 15 mm on the VAS. Data were collected during labour before the interventions, the day after birth, and two months later. Besides using the VAS, information was collected by means of study specific protocol, questionnaires and medical records. Results: The mean VAS scores were 66.4 in the MA group, 68.5 in the EA group, and 69.0 in the SC group (mean differences: MA vs. SC 2.6 95% CI -1.7 to 6.9, and EA vs. SC 0.6 95% CI -3.6 to 4.8). Other methods of pain relief were used less frequently in the EA group, including epidural analgesia, MA 61.4%, EA 46%, and SC 69.9%. (EA vs. SC OR 0.4 95% CI 0.2 to 0.7). No statistically significant differences were found in the recollection of labour pain between the three groups two months after birth (mean VAS score: MA 69.3, EA 68.7 and SC 70.1). A few maternal characteristics were associated with labour pain (age, dysmenorrhea, and cervix dilatation), but none of the investigated characteristics predicted the outcome of the acupuncture treatment in MA or EA. Women in the EA group experienced acupuncture as being effective for labour pain to a higher extent than women who received MA, MA 44.4%, EA 67.1% (EA vs. MA OR 2.4 95% CI 1.2 to 4.8). Women in the EA group also spent less time in labour (mean 500 min) than those who received MA (mean 619 min) and SC (mean 615 min) (EA vs. MA HR 1.4 95% CI 1.0 to1.9, EA vs. SC HR 1.4, 95% CI 1.1 to 2.0), and had less blood loss than women receiving SC, (EA vs. SC OR 0.1 95% CI 0.3 to 0.7). The women’s assessment of the midwife as being supportive during labour (MA 77.2%, EA 83.5%, SC 80%), overall satisfaction with midwife care (MA 100%, EA 97.5%, SC 98.7%), and having an overall positive childbirth experience (MA 64.6%, EA 61.0%, SC 54.3%) did not differ statistically. No serious side effects of the acupuncture treatment were reported. Conclusion: Acupuncture, regardless of type of stimulation, did not differ from standard care without acupuncture in terms of reducing women’s experience of pain during labour, or their memory of pain and childbirth overall two months after the birth. However, other forms of obstetric pain relief were less frequent in women receiving a combination of manual and electrical stimulation, suggesting that this method could facilitate coping with labour pain.
Resumo:
Introdução: A dor é um importante fator de incremento da morbidade e mortalidade em pacientes submetidos a procedimentos cirúrgicos que incluem toracotomias. Diversos fatores contribuem para que esses pacientes apresentem um alto grau de dor no pós-operatório, entre os quais a secção da pele, músculos e pleura, retração dos músculos e ligamentos pelo afastador de Finochietto, irritação da pleura e nervos intercostais pelos drenos tubulares torácicos e fraturas ocasionais dos arcos costais. O aumento das taxas de morbidade e mortalidade é dado principalmente à respiração superficial decorrente da pouca mobilidade da parede torácica e conseqüente à dor e pela perda da efetividade do principal mecanismo de eliminação de secreções da árvore traqueobrônquica (tosse), resultando em atelectasias, inadequado gradiente ventilação / perfusão, hipoxemia e pneumonia. Uma vez caracterizada a necessidade de atenuação da dor como fator primordial na melhora dos índices de morbidade e mortalidade no período pós-operatório de cirurgia torácica, torna-se imperiosa uma análise das terapêuticas disponíveis na atualidade para tanto. Objetivos: Avaliar a utilização de três diferentes métodos de analgesia: 1. bloqueio peridural com morfina (BPM); 2. morfina parenteral (MP); e 3. bloqueio intercostal extrapleural contínuo com lidocaína” (BIC), em pacientes submetidos a procedimentos que incluíram toracotomias em sua execução, além de analisar o custo financeiro desses métodos. Materiais e métodos: Trata-se de um estudo prospectivo, randomizado, no qual foram analisados 79 pacientes, submetidos a toracotomias, subdivididos de forma aleatória em três grupos, de acordo com a modalidade terapêutica instituída: 25 pacientes no grupo BIC, 29 pacientes no grupo BPM e 25 pacientes no grupo MP. Cada paciente foi observado e analisado por profissionais de enfermagem previamente treinados. As variáveis analisadas foram a dor e a sedação. (quantificadas através de escores e analisadas através do método de Kruskal-Wallis com correção pelo teste de Dunn), além do custo financeiro de cada método e da necessidade de administração de opióides adicionais. Resultados: As variáveis dor e sedação foram obtidas através das seguintes medianas, respectivamente: grupos BIC (2,5 e 0); BPM (4 e 0) e MP (3,5 e 0). O custo financeiro foi de US$ 78,69 para o grupo BIC; US$ 28,61 para o grupo BPM e US$ 11,98 para o grupo MP. A necessidade adicional de opióide foi de 4,2 mg/dia para o grupo BIC; 5,7 mg/dia para o grupo BPM e 10,7 mg/dia para o grupo MP. Conclusões: A intensidade da dor foi significativamente menor no grupo BIC, quando comparado ao grupo MP. Não foram identificadas diferenças significativas de intensidade da dor quando comparados os grupos BIC versus BPM e BPM versus MP. A intensidade de sedação foi significativamente maior no grupo MP quando comparado aos grupos BIC e BPM. Não foram evidenciadas diferenças significativas quanto à sedação entre os grupos BIC e BPM. O custo financeiro do grupo MP foi sensivelmente menor quando comparado aos grupos BIC e BPM. A necessidade adicional de morfina foi significativamente maior no grupo MP, quando comparados aos grupos BIC e BPM.