995 resultados para Deposition Parameters
Resumo:
Arabidopsis (Arabidopsis thaliana) leaf trichomes are single-cell structures with a well-studied development, but little is understood about their function. Developmental studies focused mainly on the early shaping stages, and little attention has been paid to the maturation stage. We focused on the EXO70H4 exocyst subunit, one of the most up-regulated genes in the mature trichome. We uncovered EXO70H4-dependent development of the secondary cell wall layer, highly autofluorescent and callose rich, deposited only in the upper part of the trichome. The boundary is formed between the apical and the basal parts of mature trichome by a callose ring that is also deposited in an EXO70H4-dependent manner. We call this structure the Ortmannian ring (OR). Both the secondary cell wall layer and the OR are absent in the exo70H4 mutants. Ecophysiological aspects of the trichome cell wall thickening include interference with antiherbivore defense and heavy metal accumulation. Ultraviolet B light induces EXO70H4 transcription in a CONSTITUTIVE PHOTOMORPHOGENIC1-dependent way, resulting in stimulation of trichome cell wall thickening and the OR biogenesis. EXO70H4-dependent trichome cell wall hardening is a unique phenomenon, which may be conserved among a variety of the land plants. Our analyses support a concept that Arabidopsis trichome is an excellent model to study molecular mechanisms of secondary cell wall deposition.
Resumo:
Tämän diplomityön tavoitteena oli sekundäärisen esiflotaation optimointi Stora Enso Sachsen GmbH:n tehtaalla. Optimoinnin muuttujana käytettiin vaahdon määrää ja optimointiparametreinä ISO-vaaleutta, saantoja sekä tuhkapitoisuutta. Lisäksi tutkittiin flotaatiosakeuden vaikutusta myös muihin tehtaan flotaatioprosesseihin. Kirjallisuusosassa tarkasteltiin flotaatiotapahtumaa, poistettavien partikkeleiden ja ilmakuplien kontaktia, vaahdon muodostumista sekä tärkeimpiä käytössä olevia siistausflotaattoreiden laiteratkaisuja. Kokeellisessa osassa tutkittiin flotaatiosakeuden pienetämisen vaikutuksia tehtaan flotaatioprosesseihin tuhkapitoisuuden, ISO-vaaleuden, valon sironta- ja valon absorpiokerrointen kannalta. Sekundäärisen esiflotaation optimonti suoritettiin muuttamalla vaahdon määrää kolmella erilaisella injektorin koolla, (8 mm, 10 mm ja 13 mm), joista keskimmäinen kasvattaa 30 % massan tilavuusvirtaa ilmapitoisuuden muodossa. Optimonnin tarkoituksena oli kasvattaa hyväksytyn massajakeen ISO-vaaleutta, sekä kasvattaa kuitu- ja kokonaissaantoa sekundäärisessä esiflotaatiossa. Flotaatiosakeuden pienentämisellä oli edullisia vaikutuksia ISO-vaaleuteen ja valon sirontakertoimeen kussakin flotaatiossa. Tuhkapitoisuus pieneni sekundäärisissä flotaatioissa enemmän sakeuden ollessa pienempi, kun taas primäärisissä flotaatiossa vaikutus oli päinvastainen. Valon absorptiokerroin parani jälkiflotaatioissa alhaisemmalla sakeudella, kun taas esiflotaatioissa vaikutus oli päinvastainen. Sekundäärisen esiflotaation optimoinnin tuloksena oli lähes 5 % parempi ISO-vaaleus hyväksytyssä massajakeessa. Kokonaissaanto parani optimoinnin myötä 5 % ja kuitusaanto 2 %. Saantojen nousu tuottaa vuosittaisia säästöjä siistauslaitoksen tuotantokapasiteetin noustessa 0,5 %. Tämän lisäksi sekundäärisessä esiflotaatiossa rejektoituvan massavirran pienentyminen tuottaa lisäsäästöjä tehtaan voimalaitoksella.
Resumo:
Two main coal-bearing sequences developed during the Oligocene in the Tertiary Ebro Basin, the Calaf (early Oligocene) and Mequinenza (late Oligocene) coal basins. Coal deposition took place in shallow marsh-swamp-lake complexes which sometimes became closed and evolved under warm climatic conditions with fluctuating humidity. These shallow lacustrine systems are closely interrelated with the terminal parts of the distributive fluvial systems which spread from the tectonically active Ebro basin margins. Laterally extensive lignite-bearing sequences, including rather thin, lenticular autochthonous and/or hypautochthonous coal seams with high ash and sulphur contents, characterized coal deposition in the shallow lacustrine systems. Coal seam geometry, which makes them nearly subeconomic, resulted from the tectonic instability during basin margin evolution and the sometimes closed, arid conditions under which the lacustrine systems evolved. High ash and sulphur contents resulted from the inadequate isolation of peat forming environments from clastic influx and from the very low acidity and sometimes high sulphate contents of the lacustrine waters. Coal exploration in shallow lacustrine sequences similar to those described here must take into account that the spread of coal-forming environments and maxima of coal deposition are usually coincident with lake expansions and retraction or shifting of the terminal fluvial zones interrelated with the lacustrine areas.
Resumo:
The University of Barcelona is developing a pilot-scale hot wire chemical vapor deposition (HW-CVD) set up for the deposition of nano-crystalline silicon (nc-Si:H) on 10 cm × 10 cm glass substrate at high deposition rate. The system manages 12 thin wires of 0.15-0.2 mm diameter in a very dense configuration. This permits depositing very uniform films, with inhomogeneities lower than 2.5%, at high deposition rate (1.5-3 nm/s), and maintaining the substrate temperature relatively low (250 °C). The wire configuration design, based on radicals' diffusion simulation, is exposed and the predicted homogeneity is validated with optical transmission scanning measurements of the deposited samples. Different deposition series were carried out by varying the substrate temperature, the silane to hydrogen dilution and the deposition pressure. By means of Fourier transform infrared spectroscopy (FTIR), the evolution in time of the nc-Si:H vibrational modes was monitored. Particular importance has been given to the study of the material stability against post-deposition oxidation.
Resumo:
Infrared spectroscopy was used to characterize three series of a-Si:H/a-Si1-xCx:H multilayers in which their geometrical parameters were varied. The infrared active vibrational groups in their spectra and the interference fringes in their absorption-free zone were studied to analyze the interfaces and the changes that are produced in very thin layers. Our results show that hydrogen is bonded to silicon only in monohydride groups. No additional hydrogen could be detected at these interfaces. The deposition of very thin a-Si1-xCx:H layers seems to affect their porous structure, making them denser.
Resumo:
The improvement of the reliability of the contact between the osseous tissues and the implant materials has been tested by recovering the metallic implants with ceramic materials, usually calcium phosphates. In our study, the calcium phosphate recovering layers were deposited by means of a pulsed-laser deposition technique. Our aim was to to evaluate the tissue interactions established between cortical bone and titanium implants covered by five different layers, ranging from amorphous calcium phosphate to crystalline hydroxyapatite, obtained by altering the parameters of the laser ablation process. The surgical protocol of the study consisted in the simultaneous implantation of the five types of implants in both the tibial dyaphisis of three Beagle dogs, sacrificed respectively one, two and three months after the last surgical procedures. After the sacrifice, the samples were submitted to a scheduled procedure of embedding in plastic polymers without prior decalcification, in order to perform the ultrastructural studies: scanning microscopy with secondary and backscattered electrons (BS-SEM). Our observations show that both in terms of the calcified tissues appearing as a response to the presence of the different coatings and of time of recovering, the implants coated with crystalline calcium phosphate layers by laser ablation present a better result than the amorphous-calcium-phosphate-coated implants. Moreover, the constant presence of chondroid tissue, related with the mechanical induction by forces applied on the recovering area, strongly suggests that the mechanisms implied in osteointegration are related to endomembranous, rather than endochondral ossification processes
Resumo:
The improvement of the reliability of the contact between the osseous tissues and the implant materials has been tested by recovering the metallic implants with ceramic materials, usually calcium phosphates. In our study, the calcium phosphate recovering layers were deposited by means of a pulsed-laser deposition technique. Our aim was to to evaluate the tissue interactions established between cortical bone and titanium implants covered by five different layers, ranging from amorphous calcium phosphate to crystalline hydroxyapatite, obtained by altering the parameters of the laser ablation process. The surgical protocol of the study consisted in the simultaneous implantation of the five types of implants in both the tibial dyaphisis of three Beagle dogs, sacrificed respectively one, two and three months after the last surgical procedures. After the sacrifice, the samples were submitted to a scheduled procedure of embedding in plastic polymers without prior decalcification, in order to perform the ultrastructural studies: scanning microscopy with secondary and backscattered electrons (BS-SEM). Our observations show that both in terms of the calcified tissues appearing as a response to the presence of the different coatings and of time of recovering, the implants coated with crystalline calcium phosphate layers by laser ablation present a better result than the amorphous-calcium-phosphate-coated implants. Moreover, the constant presence of chondroid tissue, related with the mechanical induction by forces applied on the recovering area, strongly suggests that the mechanisms implied in osteointegration are related to endomembranous, rather than endochondral ossification processes
Resumo:
The improvement of the reliability of the contact between the osseous tissues and the implant materials has been tested by recovering the metallic implants with ceramic materials, usually calcium phosphates. In our study, the calcium phosphate recovering layers were deposited by means of a pulsed-laser deposition technique. Our aim was to to evaluate the tissue interactions established between cortical bone and titanium implants covered by five different layers, ranging from amorphous calcium phosphate to crystalline hydroxyapatite, obtained by altering the parameters of the laser ablation process. The surgical protocol of the study consisted in the simultaneous implantation of the five types of implants in both the tibial dyaphisis of three Beagle dogs, sacrificed respectively one, two and three months after the last surgical procedures. After the sacrifice, the samples were submitted to a scheduled procedure of embedding in plastic polymers without prior decalcification, in order to perform the ultrastructural studies: scanning microscopy with secondary and backscattered electrons (BS-SEM). Our observations show that both in terms of the calcified tissues appearing as a response to the presence of the different coatings and of time of recovering, the implants coated with crystalline calcium phosphate layers by laser ablation present a better result than the amorphous-calcium-phosphate-coated implants. Moreover, the constant presence of chondroid tissue, related with the mechanical induction by forces applied on the recovering area, strongly suggests that the mechanisms implied in osteointegration are related to endomembranous, rather than endochondral ossification processes
Resumo:
The very usual columnar growth of nanocrystalline silicon leads to electronic transport anisotropies. Whereas electrical measurements with coplanar electrodes only provide information about the electronic transport parallel to the substrate, it is the transverse transport which determines the collection efficiency in thin film solar cells. Hence, Schottky diodes on transparent electrodes were obtained by hot-wire CVD in order to perform external quantum efficiency and surface photovoltage studies in sandwich configuration. These measurements allowed to calculate a transverse collection length, which must correlate with the photovoltaic performance of thin film solar cells. Furthermore, the density of charge trapped at localized states in the bandgap was estimated from the voltage dependence of the depletion capacitance of these rectifying contacts.
Resumo:
Amorphous silicon n-i-p solar cells have been fabricated entirely by Hot-Wire Chemical Vapour Deposition (HW-CVD) at low process temperature < 150 °C. A textured-Ag/ZnO back reflector deposited on Corning 1737F by rf magnetron sputtering was used as the substrate. Doped layers with very good conductivity and a very less defective intrinsic a-Si:H layer were used for the cell fabrication. A double n-layer (μc-Si:H/a-Si:H) and μc-Si:H p-layer were used for the cell. In this paper, we report the characterization of these layers and the integration of these layers in a solar cell fabricated at low temperature. An initial efficiency of 4.62% has been achieved for the n-i-p cell deposited at temperatures below 150 °C over glass/Ag/ZnO textured back reflector.
Resumo:
Bi1.5Zn1Nb1.5O7 (BZN) epitaxial thin films were grown by pulsed laser deposition on Al2O3 with a double ZnO buffer layer through domain matching epitaxy (DME) mechanism. The pole figure analysis and reciprocal space mapping revealed the single crystalline nature of the thin film. The pole figure analysis also shows a 60º twinning for the (222) oriented crystals. Sharp intense spots in the SAED pattern also indicate the high crystalline nature of BZN thin film. The Fourier filtered HRTEM images of the BZN-ZnO interface confirms the domain matched epitaxy of BZN with ZnO buffer. An electric field dependent dielectric tunability of 68% was obtained for the BZN thin films with inter digital capacitors patterned over the film.
Resumo:
Parkinson disease (PD) is associated with a clinical course of variable duration, severity, and a combination of motor and non-motor features. Recent PD research has focused primarily on etiology rather than clinical progression and long-term outcomes. For the PD patient, caregivers, and clinicians, information on expected clinical progression and long-term outcomes is of great importance. Today, it remains largely unknown what factors influence long-term clinical progression and outcomes in PD; recent data indicate that the factors that increase the risk to develop PD differ, at least partly, from those that accelerate clinical progression and lead to worse outcomes. Prospective studies will be required to identify factors that influence progression and outcome. We suggest that data for such studies is collected during routine office visits in order to guarantee high external validity of such research. We report here the results of a consensus meeting of international movement disorder experts from the Genetic Epidemiology of Parkinson's Disease (GEO-PD) consortium, who convened to define which long-term outcomes are of interest to patients, caregivers and clinicians, and what is presently known about environmental or genetic factors influencing clinical progression or long-term outcomes in PD. We propose a panel of rating scales that collects a significant amount of phenotypic information, can be performed in the routine office visit and allows international standardization. Research into the progression and long-term outcomes of PD aims at providing individual prognostic information early, adapting treatment choices, and taking specific measures to provide care optimized to the individual patient's needs.
Resumo:
This paper discusses the levels of degradation of some co- and byproducts of the food chain intended for feed uses. As the first part of a research project, 'Feeding Fats Safety', financed by the sixth Framework Programme-EC, a total of 123 samples were collected from 10 European countries, corresponding to fat co- and byproducts such as animal fats, fish oils, acid oils from refining, recycled cooking oils, and other. Several composition and degradation parameters (moisture, acid value, diacylglycerols and monoacylglycerols, peroxides, secondary oxidation products, polymers of triacylglycerols, fatty acid composition, tocopherols, and tocotrienols) were evaluated. These findings led to the conclusion that some fat by- and coproducts, such as fish oils, lecithins, and acid oils, show poor, nonstandardized quality and that production processes need to be greatly improved. Conclusions are also put forward about the applicability and utility of each analytical parameter for characterization and quality control.
Microdoping compensation of microcrystalline silicon obtained by Hot-Wire Chemical Vapour Deposition
Resumo:
Undoped hydrogenated microcrystalline silicon was obtained by hot-wire chemical vapour deposition at different silane-to-hydrogen ratios and low temperature (<300 °C). As well as technological aspects of the deposition process, we report structural, optical and electrical characterizations of the samples that were used as the active layer for preliminary p-i-n solar cells. Raman spectroscopy indicates that changing the hydrogen dilution can vary the crystalline fraction. From electrical measurements an unwanted n-type character is deduced for this undoped material. This effect could be due to a contaminant, probably oxygen, which is also observed in capacitance-voltage measurements on Schottky structures. The negative effect of contaminants on the device was dramatic and a compensated p-i-n structure was also deposited to enhance the cell performance.