995 resultados para Continuous flight envelope
Resumo:
Thirteen extracting solutions of rare-earth metallofullerenes containing La, Ce, Pr, Nd, Sm, Eu, Gd, Tb, Dy, Ho, Er, Tm and Yb respectively have been investigated by means of matrix-assisted laser desorption/ionization time-of-night, mass spectrometry. The influences of the positive-ion/negative-ion mode, laser intensity, matrix and mass discrimination to the analytical results are studied, based on which the optimal analytical conditions have been determined. The results show that the extracting solutions contain large quantities of rare-earth metallofullerenes brs;des empty fullerenes, On the basis of comparing their relative intensities, the different structure stabilities and solubilities of metallofullerenes with different rare-earth metals encapsulated into the fullerene cages, as well as some possible reasons to those differences, are discussed.
Resumo:
Laser desorption ionization time-of-flight mass spectrometry has been used to study the water-soluble multi-hydroxyl C-60 derivatives - fullerenols. The mass spectra exhibit unusual polymerization behavior of fullerenols. (C) 1997 by John Wiley & Sons, Ltd.
Resumo:
The cell organelles of the coenocytic alga Codium fragile (Sur.) Hariot aggregated rapidly and protoplasts were formed when its protoplasm was extruded out in seawater. Continuous observation showed that there were long and gelatinous threads connecting the cell organelles. The threads contracted, and thus the cell organelles aggregated into protoplasmic masses. The enzyme digestion experiments and Coomassie Brilliant Blue and Anthrone stainings showed that the long and gelatinous threads involved in the formation of the protoplasts might include protein and saccharides as structure components. Nile Red staining indicated that the protoplast primary envelope was non-lipid at first, and then lipid materials integrated into its surface gradually. The fluorescent brightener staining indicated that the cell wall did not regenerate in the newly formed protoplasts and they all disintegrated within 72 h after formation. Transmission electron microscopy of the cell wall of wild C. fragile showed electron-dense material embedded in the whole cell wall at regular intervals. The experiments indicated that C. fragile would be a suitable model alga for studying the formation of protoplasts.
Resumo:
An oxygen permeable mixed ion and electron conducting membrane (OPMIECM) was used as an oxygen transfer medium as well as a catalyst for the oxidative dehydrogenation of ethane to produce ethylene. O2- species transported through the membrane reacted with ethane to produce ethylene before it recombined to gaseous O-2, so that the deep oxidation of the products was greatly suppressed. As a result, 80% selectivity of ethylene at 84% ethane conversion was achieved, whereas 53.7% ethylene selectivity was obtained using a conventional fixed-bed reactor under the same reaction conditions with the same catalyst at 800 degreesC. A 100 h continuous operation of this process was carried out and the result indicates the feasibility for practical applications.
Laser induced photoelectron impact ionization in time-of-flight mass spectrometer 飞行时间质谱中光发射电子碰撞电离过程
Resumo:
This paper presents precise versions of some "laws" that must be satisfied by computations involving communicating parallel processes. The laws take the form of stating plausible restrictions on the histories of computations that are physically realizable. The laws are very general in that they are obeyed by parallel processes executing on a time varying number of distributed physical processors.
Resumo:
We report a 75dB, 2.8mW, 100Hz-10kHz envelope detector in a 1.5mm 2.8V CMOS technology. The envelope detector performs input-dc-insensitive voltage-to-currentconverting rectification followed by novel nanopower current-mode peak detection. The use of a subthreshold wide- linear-range transconductor (WLR OTA) allows greater than 1.7Vpp input voltage swings. We show theoretically that this optimal performance is technology-independent for the given topology and may be improved only by spending more power. A novel circuit topology is used to perform 140nW peak detection with controllable attack and release time constants. The lower limits of envelope detection are determined by the more dominant of two effects: The first effect is caused by the inability of amplified high-frequency signals to exceed the deadzone created by exponential nonlinearities in the rectifier. The second effect is due to an output current caused by thermal noise rectification. We demonstrate good agreement of experimentally measured results with theory. The envelope detector is useful in low power bionic implants for the deaf, hearing aids, and speech-recognition front ends. Extension of the envelope detector to higher- frequency applications is straightforward if power consumption is inc
Resumo:
Two kinds of process models have been used in programs that reason about change: Discrete and continuous models. We describe the design and implementation of a qualitative simulator, PEPTIDE, which uses both kinds of process models to predict the behavior of molecular energetic systems. The program uses a discrete process model to simulate both situations involving abrupt changes in quantities and the actions of small numbers of molecules. It uses a continuous process model to predict gradual changes in quantities. A novel technique, called aggregation, allows the simulator to switch between theses models through the recognition and summary of cycles. The flexibility of PEPTIDE's aggregator allows the program to detect cycles within cycles and predict the behavior of complex situations.
Resumo:
In this article, we describe an apparatus in our laboratory for investigating elementary chemical reactions using the high resolution time-of-flight Rydberg tagging method. In this apparatus, we have adopted a rotating source design so that collision energy can be changed for crossed beam studies of chemical reactions. Preliminary results on the HI photodissociation and the F atom reaction with H-2 are reported here. These results suggest that the experimental apparatus is potentially a powerful tool for investigating state-to-state dynamics of elementary chemical reactions. (c) 2005 American Institute of Physics.
Resumo:
A sample of tobacco essential oil was analyzed using gas chromatography-mass spectrometry (GUMS)and comprehensive two-dimensional gas chromatography coupled to a time-of-flight mass spectrometry (GC x GC/TOFMS), respectively. In the GUMS analysis, serially coupled columns were used. By comparing the GUMS results with GC x GC/TOFMS result,,, many more components in the essential oil could be found within the two-dimensional separation space of GC x GC. The quantitative determination of components in the essential oil was performed by GC x GC with flame ionization detection (FID), using a method of multiple internal standards calibration, (c) 2005 Elsevier B.V. All rights reserved.
Resumo:
A quantitative analysis of the individual compounds in tobacco essential oils is performed by comprehensive two-dimensional gas chromatography (GC x GC) combined with flame ionization detector (FID). A time-of-flight mass spectrometer (TOF/MS) was coupled to GC x GC for the identification of the resolved peaks. The response of a flame ionization detector to different compound classes was calibrated using multiple internal standards. In total, 172 compounds were identified with good match and 61 compounds with high probability value were reliably quantified. For comparative purposes, the essential oil sample was also quantified by one-dimensional gas chromatography-mass spectrometry (GC/MS) with multiple internal standards method. The results showed that there was close agreement between the two analysis methods when the peak purity and match quality in one-dimensional GC/MS are high enough. (c) 2005 Elsevier B.V. All rights reserved.
Resumo:
The use of matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS) for environmental analysis has been mainly focused on qualitative analysis of high-mass molecules, such as toxins, humic acid, and microorganisms. Herein,we describe a novel MALDI-TOF-MS method with a matrix of oxidized carbon nanotubes for analysis of low-mass compounds in environmental samples. A number of chemicals in the environment were qualitatively analyzed by the present method, and it was found that most of them, especially the highly polar chemicals, were measurable with high sensitivity. With the intrinsic ability to measure high-mass chemicals, this method can compensate for the current shortage of methods for environmental analysis for the measurement of highly polar or high-mass chemicals. For sample analysis, arsenic speciation in Chinese traditional medicines was qualified and diphenylolpropane in water samples was quantified. With the relatively high tolerance of the method to interfering molecules, a simple pretreatment or even no pretreatment could be employed before MS detection. Furthermore, this method can be employed in a high-throughput format.