952 resultados para Cleaning procedures
Resumo:
Objective. To determine the effects of different aging methods on the degradation and flexural strength of yttria-stabilized tetragonal zirconia (Y-TZP)Methods. Sixty disc-shaped specimens (0, 12 mm; thickness, 1.6 mm) of zirconia (Vita InCeram 2000 YZ Cubes, VITA Zahnfabrik) were prepared (ISO 6872) and randomly divided into five groups, according to the aging procedures (n=10): (C) control; (M) mechanical cycling (15,000,000 cycles/3.8 Hz/200N); (T) thermal cycling (6,000 cycles/5-55 degrees C/30 s); (TM) thermomechanical cycling (1,200,000 cycles/3.8 Hz/200N with temperature range from 5 C to 55 C for 60s each); (AUT) 12h in autoclave at 134 degrees C/2 bars; and (STO) storage in distilled water (37 degrees C/400 days). After the aging procedures, the monoclinic phase percentages were evaluated by X-ray diffraction (XRD), and topographic surface analysis was performed by 3D profilometry. The specimens were then subjected to biaxial flexure testing (1 mm/min, load 100 kgf, in water). The biaxial flexural strength data (MPa) were analyzed by 1-way ANOVA and Tukey's test (alpha = 0.05). The data for monoclinic phase percentage and profilometry (Ra) were analyzed by Kruskal-Wallis and Dunn's tests.Results. ANOVA revealed that flexural strength was affected by the aging procedures (p = 0.002). The M (781.6 MPa) and TM (771.3 MPa) groups presented lower values of flexural strength than did C (955 MPa), AUT (955.8 MPa), T (960.8 MPa) and STO (910.4 MPa). The monoclinic phase percentage was significantly higher only for STO (12.22%) and AUT (29.97%) when compared with that of the control group (Kruskal-Wallis test, p = 0.004). In addition, the surface roughnesses were similar among the groups (p = 0.165).Signcance. Water storage for 400 days and autoclave aging procedures induced higher phase transformation from tetragonal to monoclinic; however, they did not affect the flexural strength of Y-TZP ceramic, which decreased only after mechanical and thermomechanical cycling. (C) 2014 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The performance analysis based on indicators is an important tool when you want to check the economic and financial situation of a company. From the information provided by the ratios and their analysis, we have a better base for a decision making In this context , this study aims to analyse the financial and economic performance of a service providing company in the cleaning area, in the period between 2011 and 2012 , based on selected financial indicators, and basically calculated from the financial statements (Balance Sheet and Income Statement) , beyond effectuated the vertical and horizontal analysis of them. For the methodological procedures it was used a descriptive case of study and combined (quantitative and qualitative). The results revealed that the economic and financial situation of the company is healthy , once the results are considered satisfactory
Resumo:
Thin films of Ga1-xMnxN have great interest in its potential for control of electron spin (spintronics), in most cases this material is synthesized by techniques that have a high degree of control the deposition parameters, such as molecular beam epitaxy (MBE) and deposition of metalorganic chemical vapor deposition (MOCVD). The sputtering technique is an alternative route to produce such materials. Here we study the film deposition Ga1-xMnxN by reactive sputtering technique and apply enhancements such as a glove box, a residual gas analyzer and temperature control system, in order to growth films epitaxially using an analysis of the preconditions of films analyzed by spectroscopic techniques and microscopic. These procedures helped to improve the technique of deposition by cleaning substrates in an inert environment, and by the analysis of trace gases and heating the substrate holder as explained in the literature. Through the applications and comparisons it can be pointed out that the technique has the advantage of its simplicity and relatively low cost compared to MBE and MOCVD, but produces polycrystalline material
Resumo:
Pós-graduação em Saúde Coletiva - FMB
Resumo:
This paper reports two clinical cases in which the application of low-level laser therapy (LLLT) enhanced the postoperative symptoms after pediatric surgical procedures. Background: The uses of novel technologies allow more comfort to the patients and ensure a rapid procedure, and LLLT application has shown a positive effect in the prevention of discomfort after invasive procedures. Case description: Low-level laser therapy protocol was applied after surgical removal of supernumerary tooth and frenectomy resulting in less swallow and pain with no need of medication intake. Conclusion: The laser application was well accepted by both children and parents and showed a clinical efficiency in the follow-up examinations beyond the satisfactory quality of wound healing. Clinical significance: The LLLT approach is an excellent adjuvant therapy resource for delivery an optimal postoperative after surgical procedures in children.
Resumo:
This study evaluated the influence of finishing and polishing procedures and differ-ent fluoride solutions on superficial morphology and chemistry of the nanofilled composite resinSupreme XT (3M) through the EDX analysis and SEM evaluation. Circular specimens (n 5 30) of 10mm diameter and 2 mm thickness were prepared, with half of the sample assays finished and polishedwith Super-Snap1sandpaper. The experimental groups were divided according to the presence or ab-sence of finishing and polishing and solutions (arti ficial saliva, 0.0 5% of manipulated sodium fluoridesolution, Fluordent Re ach, Oral B, Fluorgard). Specimens were immersed in each respective solutionfor 1 min per day, during 60 days and stored in artificial saliva at 37 6 18C between immersion peri-ods. Topography and chemical analysis was qualitative. It was observed that specimens submitted tofinishing and polishing procedures had lower superficial degradation. Fluoride solutio ns promoted su-perficial alterations on specimens, being the highest degradation obtained with Fluordent Reach. Itca n be concluded that finishing and polishing procedures and the immersion media influence the su-perficial morphology of composite resin tested; the Fluordent Reach was the flu oride solution thatmo st affected the material’s surface.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The aim of this study was to assess the cleaning capacity of the Protaper system using motor-driven or manual instrumentation. Materials and Methods: Ten mandibular molars were randomly separated into 2 groups (n = 5) according to the type of instrumentation performed, as follows: Group 1 - instrumentation with rotary nickel-titanium (Ni-Ti) files using ProTaper Universal System (Dentsply/Maillefer); and, Group 2 - instrumentation with Ni-Ti hand files using ProTaper Universal (Dentsply-Maillefer). Afterwards, the teeth were sectioned transversely and submitted to histotechnical processing to obtain histological sections for microscopic evaluation. The images were analyzed by the Corel Photo-Paint X5 program (Corel Corporation) using an integration grid superimposed on the image. Results: Statistical analysis (U-Mann-Whitney - P < 0.05) demonstrated that G1 presented higher cleaning capacity when compared to G2. Conclusions: The rotary technique presented better cleaning results in the apical third of the root canal system when compared to the manual technique.
Resumo:
Rats bearing lesions in the septal area followed by lesions in the subfornical organ were submitted to various thirst-eliciting procedures. The rats with hyperdipsia induced by lesions of the septal area drank more water than either during the control period or after lesion of the subfornical organ under the same thirst-eliciting or angiotensin-liberating stimuli (polyethyleneglycol, isoproterenol, water deprivation and ligation of the inferior vena cava). The overdrinking elicited by lesions in the septal area was blocked after lesion of the subfornical organ. Neither hypovolemia, nor hypotension or water deprivation could elicit increased water intake in animals whose subfornical organ had been destroyed. Animals with lesions in the subfornical organ showed decreased water intake after cellular dehydration. The results obtained suggest that the subfornical organ acts as a more important structure than the septal area in the regulation of water intake elicited by angiotensin, with two opposite effects: a direct one facilitating water intake, and an indirect one inhibiting the septal area. The septal area has an inhibitory effect on the subfornical organ and on water intake. © 1980.
Resumo:
To compare the use of analgesia versus neonatologists' perception regarding analgesic use in painful procedures in the years 2001, 2006, and 2011. This was a prospective cohort study of all newborns admitted to four university neonatal intensive care units (NICUs) during one month in 2001, 2006, and 2011. The frequency of analgesic prescription for painful procedures was evaluated. Of the 202 neonatologists, 188 answered a questionnaire giving their opinion on the intensity of pain during lumbar puncture (LP), tracheal intubation, mechanical ventilation (MV), and postoperative period (PO) using a 10-cm visual analogic scale (VAS; pain >3cm). For LP, 12% (2001), 43% (2006), and 36% (2011) were performed using analgesia. Among the neonatologists, 40-50% reported VAS >3 for LP in all study periods. For intubation, 30% received analgesia in the study periods, and 35% (2001), 55% (2006), and 73% (2011) of the neonatologists reported VAS >3 and would prescribe analgesia for this procedure. As for MV, 45% (2001), 64% (2006), and 48% (2011) of patient-days were under analgesia; 56% (2001), 57% (2006), and 26% (2011) of neonatologists reported VAS >3 and said they would use analgesia during MV. For the first three PO days, 37% (2001), 78% (2006), and 89% (2011) of the patients received analgesia and more than 90% of neonatologists reported VAS >3 for major surgeries. Despite an increase in the medical perception of neonatal pain and in analgesic use during painful procedures, the gap between clinical practice and neonatologist perception of analgesia need did not change during the ten-year period.
Resumo:
The purpose of this study was to evaluate the impact of different disinfection solutions on flexural resistance of chemically-activated acrylic resin. Test pieces were made of clear acrylic resin using a rectangular mold and employing two techniques: wet polymerization under pressure (n = 20) and dry polymerization under pressure (n = 20). Test pieces were subdivided into four equal groups: distilled water (control), sodium bicarbonate, 1% sodium hypochlorite and effervescent ats. The 30-day cycling technique consisted of immersing the test pieces in 100 ml of solution for 10 min three times a day and placing them in closed containers containing artificial saliva at 37°C. Subsequently, the flexural resistance of samples was tested. Data were analyzed using two-way analysis of variance (ANOVA) with forces serving as the dependent variables and the polymerization technique and cleaning agents as independent variables. Post hoc multiple comparisons were performed using Tukey’s test. There was no statistically significant difference in the flexural strength between the two polymerization techniques. The greatest flexural strength was observed for the effervescent tablets group followed by the control and 1% sodium hypochlorite groups which were statistically similar. Thus, the sodium bicarbonate solution caused the lowest flexural resistance of the test pieces.